Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.9 LAccepted-AOC 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L1 | Accepted-AOC AOC_Issued | |
| 2 | L2₹48.5 L+₹62,070 (1.30%)Rejected-Finance A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance That the bid is not L1 | |
| 3 | L3₹49.1 L+₹1.2 L (2.41%)Rejected-Finance | L3 | Rejected-Finance That the bid is not L1 | |
| 4 | L4₹53.6 L+₹5.7 L (11.9%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L4 | Rejected-Finance That the bid is not L1 |
| Sl No | Description | Qty | Unit | Lyric International L4 | SKY DECORATIONS PRIVATE LIMITED L1 | MAXCOOL REFRIGERATION CO. L2 | jhonson controls hitachi air conditioning india limited L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply & Delivery of 230V,1-Ph, 50Hz, 2Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 24000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32/R-22, Air Flow/IDU:- 800CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes.
(Make:- Daikin/Voltas/Hitachi/O General) | 60 | Nos. | 65,500 ₹39,30,000 | 62,500 ₹37,50,000 Lowest | 62,600 ₹37,56,000 | 62,700 ₹37,62,000 |
| 2.00 | Supply & Delivery of 230V,1-Ph, 50Hz, 1.5Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 18000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32/R-22, Air Flow/IDU:- 600CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes.
(Make:- Daikin/Voltas/Hitachi/O General) | 6 | Nos. | 55,000 ₹3,30,000 | 52,600 ₹3,15,600 Lowest | 52,700 ₹3,16,200 | 52,850 ₹3,17,100 |
| 3.00 | Installation, Testing & Commissioning of Indoor & Outdoor unit of the following capacity concealed type Split Air Conditioners after making hole in wall & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC.
(a) 2 Tr. | 60 | Nos. | 6,500 ₹3,90,000 | 2,500 ₹1,50,000 Lowest | 2,650 ₹1,59,000 | 2,690 ₹1,61,400 |
| 3.10 | (b) 1.5 Tr. | 6 | Nos. | 3,500 ₹21,000 | 2,500 ₹15,000 Lowest | 2,600 ₹15,600 | 2,700 ₹16,200 |
| 4.00 | Copper Refrigeration pipe line with 0.6 mm(min) & 0.7 mm (min) thick for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku/Totaline/Jobu/Nippon)
(a) Liquid Line (1/4" OD or as per manufacturer specification) | 660 | Mtrs. | 205 ₹1,35,300 Lowest | 205 ₹1,35,300 Lowest | 230 ₹1,51,800 | 260 ₹1,71,600 |
| 4.10 | (b) Suction Line (5/8" OD withor as per manufacturer specification) | 660 | Mtrs. | 450 ₹2,97,000 | 365 ₹2,40,900 Lowest | 375 ₹2,47,500 | 389 ₹2,56,740 |
| 5.00 | Supply & Fixing Pipe Insulation in liquid & suction line with 9 mm nitrile rubber tube (Accoflex/Armacell/Supreme)
(a) Liquid Line (1/4" OD with 0.6 mm thick) | 660 | Mtrs. | 30 ₹19,800 Lowest | 32 ₹21,120 | 40 ₹26,400 | 43 ₹28,380 |
| 5.10 | (b) Suction Line (5/8" OD with 0.7mm thick) | 660 | Mtrs. | 35 ₹23,100 Lowest | 39 ₹25,740 | 41 ₹27,060 | 46 ₹30,360 |
| 6.00 | Supply and fixing of 4 X 2.5 Sq mm Control Cable, inside Precision make polythene pipe, with proper dressing, for the communication of IDU and ODU, as per Direction of E.I.C.
(Make: Gloster/Havells/Ploycab/ Finolex) | 660 | RM | 140 ₹92,400 | 105 ₹69,300 Lowest | 116 ₹76,560 | 125 ₹82,500 |
| 7.00 | S&F of 50 mm PVC Drain Pipe Line (50 mm OD, HD 1 mm Thick) with Insulation , Support & Bracket and other necessary arragnement for vertical run along the building including necessary scaffolding arrangement etc as per site condition & direction of EIC | 330 | RM | 205 ₹67,650 | 135 ₹44,550 Lowest | 148 ₹48,840 | 156 ₹51,480 |
Tender Value
₹56.7 L
EMD Value
₹1.1 L
Closing Date
25 Sept 2024, 4:00 pmClosed
EE,KNHED,PW Dte
THE EXECUTIVE ENGINEER, P.W.D /KOLKATA NORTH HEALTH ELECTRICAL DIVISION
Repair renovation of the Rest-rooms of On-call Junior Doctors / Sr. Residents / PGTs, including repair renovation of toilets for their comfortable Stay (Rattirer Sathi), at Casualty Bldg. and Trauma Care Bldg. of RG Kar MCH - SITC AC Machine
2024_WBPWD_751927_1
WBPWD/EE/KNHED/e-NIQ-65/24-25
Open Tender
A/C ORG
Item Rate
7 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.1 L
17 Apr 2026
16 Sept 2024
27 Sept 2024
16 Sept 2024
25 Sept 2024
16 Sept 2024
Amount
Supply & Delivery of 230V,1-Ph, 50Hz, 2Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 24000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32/R-22, Air Flow/IDU:- 800CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/O General)
Supply & Delivery of 230V,1-Ph, 50Hz, 1.5Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 18000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32/R-22, Air Flow/IDU:- 600CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/O General)
Installation, Testing & Commissioning of Indoor & Outdoor unit of the following capacity concealed type Split Air Conditioners after making hole in wall & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC. (a) 2 Tr.
Copper Refrigeration pipe line with 0.6 mm(min) & 0.7 mm (min) thick for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku/Totaline/Jobu/Nippon) (a) Liquid Line (1/4" OD or as per manufacturer specification)
(b) Suction Line (5/8" OD withor as per manufacturer specification)
Supply & Fixing Pipe Insulation in liquid & suction line with 9 mm nitrile rubber tube (Accoflex/Armacell/Supreme) (a) Liquid Line (1/4" OD with 0.6 mm thick)
(b) Suction Line (5/8" OD with 0.7mm thick)
Supply and fixing of 4 X 2.5 Sq mm Control Cable, inside Precision make polythene pipe, with proper dressing, for the communication of IDU and ODU, as per Direction of E.I.C. (Make: Gloster/Havells/Ploycab/ Finolex)
S&F of 50 mm PVC Drain Pipe Line (50 mm OD, HD 1 mm Thick) with Insulation , Support & Bracket and other necessary arragnement for vertical run along the building including necessary scaffolding arrangement etc as per site condition & direction of EIC
S&F of 25 mm PVC Drain Pipe Line (25 mm OD, HD 1 mm Thick) with Insulation , Support & Bracket for connecting the vertical run drian pipe with outdoor unit including necessary scaffolding arrangement etc as per site condition & direction of EIC.
(Rate should be quotated including all taxes and duties and GST)
MAXCOOL REFRIGERATION CO. (BID ID -5606940)
jhonson controls hitachi air conditioning india limited (BID ID -5607328)
Lyric International (BID ID -5602484)
stage.html
html • 0.05 MB
technical_1662073.pdf
techsummary_1662073.pdf
finance_1662073.pdf
BOQ Comparative Chart
xlsx
finsummary_1662073.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.56 MB
2911.pdf
Tender Documents • 1.46 MB
BOQ_1662073.xls
BOQ • 0.24 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .