Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC | ₹4.8 L | L1 | Accepted-AOC As peer NIT |
| 2 | L2₹4.9 L+₹15,934.37 (3.34%)Rejected-Finance NULL | ₹4.9 L+₹15,934.37 (3.34%) | L2 | Rejected-Finance As per NIT |
| 3 | L3₹5.1 L+₹36,690.99 (7.69%)Rejected-Finance 0 0 0 ABABAKPUR KANPUR NAGAR UTTAR PRADESH 209203 UDYAM UP 43 0068644 | KANPUR NAGAR | UTTAR PRADESH | 209203 | ₹5.1 L+₹36,690.99 (7.69%) | L3 | Rejected-Finance As per NIT |
| 4 | L4₹5.2 L+₹41,932.56 (8.79%)Rejected-Finance | ₹5.2 L+₹41,932.56 (8.79%) | L4 | Rejected-Finance As per NIT |
Tender Value
₹5.2 L
EMD Value
₹11,100
Closing Date
24 Apr 2026, 3:00 pmClosed
Sh. Sudhir Kumar
Old Zonal MCD Office, Vishal Enclave, Rajouri Garden, West Zone, Delhi -110027.
Repairing and Improvement of Electrical Installation of various PT/CTC blocks in Ward No - 98, 99 and 100 under West Zone.
2026_MCD_275046_1
E.E(Elect.)/WZ/2026-27/NIT No.04
Open Tender
Electrical Works
Percentage
150 days
EE/Electrical-III Division West Zone.
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹11,100
4 May 2026
17 Apr 2026
24 Apr 2026
17 Apr 2026
24 Apr 2026
17 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Supply of 12" (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as required | - | Each | - | - |
| 1.002 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep | - | Each | - | - |
| 1.003 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | - | Each | - | - |
| 1.004 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm | - | metre | - | - |
| 1.005 | 3 x 4 sq. mm | - | metre | - | - |
| 1.006 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch | - | Each | - | - |
| 1.007 | 3 pin 5/6 amp socket outlet | - | Each | - | - |
| 1.008 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 18- 22 watt | - | Each | - | - |
| 1.009 | SITC of single phase monoblock pump set complete with all accessories workable on 240/515 volts, 50 Hz AC supply (a) 1 HP (0.75 KW) single phase pump set, head from 12-30 metre suction and delivery 25x25 mm. | - | Each | - | - |
| 1.01 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).
Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10%)as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000m Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 50 watt | - | Each | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
0401ConditionsandCircular.pdf
Tender Documents • 10.99 MB
0401GCC.pdf
Tender Documents • 1.74 MB
0401DNIT.pdf
Tender Documents • 2.10 MB
0401Schedule.pdf
Tender Documents • 3.38 MB
BOQ_321246.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .