Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC DALHOUSIE ROAD BYE PASS CHOWK PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹22.9 L+₹38,388 (1.70%)Rejected-Finance 451 NEAR RADHA KRISHAN MANDIR VPO MAMUN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹24.6 L+₹2.0 L (9.07%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹26.5 L+₹4.0 L (17.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹32.0 L+₹9.4 L (41.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹73,000
Closing Date
10 Dec 2020, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT
PROVISION OF NEW LPG STORE NEAR BLDG NO T-50 RATION STORE AND CERTAIN SANCTIONED WORKS UNDER AGE B/R-I OF GE (SOUTH) MAMUN
2020_MES_394131_1
GE(S)/M-50/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH MAMUN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹73,000
Yes
24 Dec 2020
10 Nov 2020
12 Dec 2020
10 Nov 2020
10 Dec 2020
28 Nov 2020
10 Nov 2020 - 16 Nov 2020
Amount
Taking down carefully existing ceiling fan/wiring, and re-fix the same after repair including testing, complete all as specified and directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Carefully demolition of existing PCC exc. 15cm thick on dispersal area by mechanical cutter to facilitate earth work for drain work etc incl. removing dabries out side Avn site as shown by Engineer- in- charge complete all as specified and directed.
Demolition of brick work / stone masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Demolition of (unreinforced) cement concrete in ground floor and pavings n. exc. 15cm thickness (below or above the ground level), complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not specifically provided for, complete all as specified and directed. Note:- Reinforcement shall be cut as required to facilitate demolition.
Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
Rough excavation over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed.
Excavation over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
Removal of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
Removal of excavated material (soil) to a distance exceeding 50 metre and not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
Returning, filling in, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
M&L for hard core of broken stone or boulders of gauge n. exc. 63 mm, deposited, spread and leveled in layers n. exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for treating the back fill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with back fill to be measured) complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litres of emulsion per metre of the perimeter wall complete all as specified and directed.
M&L for cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed.
M&L brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6 mtr mean radius built in CM (1:6) complete all as specified and directed.
M&L brick work with old size bricks, straight or curved on plan exc 6 mtr mean radius built in CM (1:4) complete all as specified and directed.
M&L brick work (Except bricks), straight or curved on plan exc 6 mtr mean radius built in CM (1:4) complete all as specified and directed.
M&L for form work to sides of flat, rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical to batter complete all as specified and directed.
M&L for form work to sides and soffits of flat, rough finished surfaces of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
M&L for form work to flat, rough finished surfaces of concrete of chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L for form work to sides of square, rectangular or polygonal, rough finished surfaces of concrete of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L for form work to soffits of flat, rough finished surfaces of concrete of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10 cm but n. exc. 20 cm wide, rough finished surfaces of concrete complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs and mass concrete complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in beams, cantilevers, bressumers, lintels, shelves complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in chajjas complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves and the like complete all as specified and directed.
M&L for 15mm thick rendering in two layers (5mm thick in CM 1:4 over 10 mm thick rendering in CM 1:6) on brick work or concrete surfaces mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, finished even and smooth without using extra cement, complete all as specified and directed. NOTE : Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L for rendering 15 mm thick in CM 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 12 mm thick in CM 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on concrete surfaces in ceiling including finishing even and smooth without using extra cement complete all as specified and directed.
M&L 15mm thick cement plaster in cement mortar 1:4 on newly laid RCC roof slab whilest the concrete still green and finished the surface even and smooth including and mixing of WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified and directed.
M&L APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning the surface of RCC roof slab to receive APP membrane. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3.6mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint, white or tinted, over and including a coat of alkali-resistant priming paint complete all as specified and directed.
M&L for preparation of new plastered surface wall by applying two coats of oil bound distamper over a coat of chalk whitening primer, complete all as specified and directed.
M&L for preparation of new plastered surface wall by applying two coats of exterior weather coat paint over and including a coat of alkali-resistant primer, complete all as specified and directed.
S&F pressed steel frame of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate including filling of PCC 1:3:6 type C-0 (using 12.5mm graded stone aggregates) in frames/hold fast blocks, complete all as specified and directed.
S&F 35mm thick 2nd class hard wood plain framed factory made, panelled shutter (two panel) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm thick veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS :1003, complete all as specified and directed.
S&F 3mm thick plain sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exc 0.50 Sqm in each pane, complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for mild steel deformed or twisted bars 6 to 8 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., omplete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290 Gde E-165, complete all as specified and directed.
S&F galvanized stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
M&L for preparation of newly or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and directed.
M&L for preparation of newly or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
S&F 300 mm long, mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S&F 150 mm long, mild steel, barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
S&F 200 mm long, aluminium anodised, barrel tower bolts, extruded section (ISI marked) and fixed complete all as specified and directed.
S&F aluminium handles cast type anodised of size 150mm long, ISI marked, complete all as specified.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate in plinth protection. Concrete shall be laid in alternate bays n.exc 3 m in length finished fair and even including provision of joints of 6 mm wide and 10 mm deep along the wall and bays filled with bitumen mastic (1:3) complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) laid in alternate panel as in floor finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) laid in alternate panel as in floor finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in floor finished the surface even and smooth without usingextra cement, complete all as specified and directed.
M&L for 125mm thick PCC 1:1.5:3 type A-1 (using 20mm graded crushed stone aggregates) as in floor finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) in sub base of floors complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base of floors complete all as specified and directed.
M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound (Grade 'A') complete all as specified and directed.
S&F box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick M S sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid seperately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100 mm long for each leaf and 10 mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 complete all as specified and directed.
S&F Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete complete all as specified and directed.
S&F 1.25mm thick mild steel, plain, black sheet, but in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in coping, bedding, haunching against the side of wall of manholes and kerbs of interlocking tiles, complete all as specified and directed.
M&L for precast cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) set in CM 1:6 as in cover slabs (for manholes etc) with plain fair faces complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; incomplete all as specified and directed.
M&L for Salt-glazed stoneware drain pipes 150mm bore laid in trenches and jointed as specified complete all as specified and directed.
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.
M&L for Extra for forming fair finished drain or channel 15 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.
M&L for 20mm bore water tubes 'medium grade' galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
S&F 20mm bore stop valve, cast copper alloy (ISI Marked), screwed down, light pressure with crutch or butterfly handle, screwed both ends, for iron pipe or for union complete all as specified and directed.
M&L False ceiling of 9.5mm thick gypsum tiles (600x600mm) laminated with PVC film on the face side & metalised polyester film on the back side with all four edges sealed with PVC film (shade either plain white or crack) fixed using T grid/Cross-T/Wall angle/level clip & suspenders of standard galvanised sections in a grid size of 600x600mm of manufacturer M/s Saint Gobain or equivalent of Armstong/Everest including taking down existing ceiling board & grid work etc of any type/pattern complete all as specified and directed. Note:- Invoice from company's authorized dealer, along with dealership certificate of genuineness from the manufacturer shall be submitted with materials by the contractor before getting the material approved from the department.
M&L for Soakage well including excavation and earth work in any type of soil, foundation in PCC 1:4:8, brick walls of honey combed and solid in CM 1:4, RCC cover slab including RCC precast manhole cover having 6mm plate embedded all around / fibre reinforced cover with angle iron frame, intercepting and screen chamber, filling with brick bats at required height etc. complete of size 1.80 Mtr dia X 3.00 Mtr deep, complete all as specified and shown on drg TD Drg No CEPZ/C-TD/013/13 sheet 1/5 to 5/5.
M&L for point wiring for one light point / fan point / bell point controlled by one switch with 1.5 Sqmm PVC insulated unsheathed copper conductor single core multistranded FRLS cable and 1.5 Sqmm PVC insulated unsheathed copper conductor single core multistranded FRLS (green colour) cable as earth lead drawn in and including connected non metallic rigid PVC conduit including CI/MS terminal box of required size including 3mm thick plastic laminated top sheet cover including cutting chases to walls and making good the disturbed surfaces to match with the existing specifications, complete all as specified and directed.
Description all as per Srl item No 86 here-in-above but one 3 pin 6 Amps socket outlet multipurpose on same board complete all as specified and directed.
S&F socket, 5 pin 6 amps, flush type, 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F Switch piano flush button, single pole, one way, 5 Amps, 230 Volts AC with polycarbonate body, complete all as specified and directed.
S&F ceiling rose, surface bakelite, 3 terminals, 230 Volts AC with polycarbonate body, complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board, single pole & neutral, 240 Volts, 200 Amp, 4 Way with IP-43 IK-09 protection, single door, complete with appropriate size bus bar neutral link earth bar and din rail single phase and including cutting chases to wall for fixing enclosure and making good the disturbed surface to match with existing specifications, complete all as required at site and directed by Engineer-in-Charge.
S&F MCB single pole, 230 Volts, 6 to 32 Amps with repturing capacity 10 KA 'C' Curve including providing thimble for outgoing cables, complete all as specified and directed.
S&F MCB single pole and neutral, 230 Volts, 6 to 32 Amps with repturing capacity 10 KA 'C' Curve including providing thimble for outgoing cables, complete all as specified and directed.
S&F LED batten fitting 20 Watt (4 feet long) with in built LED tube rod complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or complete all as specified and directed.
S&F bulk head 10 Watt LED light fitting IP-43 in engineering plastic housing with clear primatic diffuser complete with all acessories, connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm as required, complete all as specified and directed.
Supply and laying in trenches/on wall/on pole/in duct /through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 10 Sqmm 2 core size complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
M&L for 40mm bore galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings such as MS clamps of size 25mm x 4mm, nuts, bolts, washers etc, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
RD Engineers
M/S NARESH KUMAR SHARMA
Ms Dalip Kumar and Co.
M/S BHOTO AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .