SPECIAL REPAIR OF E/M INFRASTRUCTURE OF SMQ AREA OF HQ WAC AT SUBROTO PARK UNDER GE (AF) SUBROTO PARK, DELHI CANTT-10
2026_MES_751694_4
CWE/PM/N-35/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Subroto Park
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE (AF) Subroto Park
₹77,280
Yes
20 Aug 2026
20 Aug 2026
14 Sept 2026
20 Aug 2026
7 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old MS cross arms, supports, etc from four pole structure by removing nuts, bolts, etc complete all as specified and directed. | 4 | Qtl | - | - |
| 2 | Taking out old HT cables carefully after disconnecting the cable from two pole/ four pole structure for reconnecting the same in RMU /Transformer complete all as specified and directed. | 8 | Each Job | - | - |
| 3 | M&L for dismantling old four pole structure and taking down the existing transformer carefully and safely with the help of crane, chainpully, etc. & installation of the transformer on newly constructed PCC platform with roller & stopper, etc removing of old poles outside Subroto Park complete all as specified and directed.
(Note:- Two Nos. of four pole to be removed and only one number of transformer to be removed and installed on new PCC platform). | 2 | Each Job | - | - |
| 4 | Supply, installation, testing & commissioning of 11 KV outdoor type (IP54) RMU dust and vermin proof, with locking arrangement, duly powder coated, totally enclosed, free standing floor mounting type, compartment based type one side-extendable 3-way Ring Main Unit floor mounted with internal copper bus bars, consisting of 3 nos. fixed type motorised Vacuum Circuit Breaker (2 Incoming & 1 Outgoing) with additional BUS PT metering module. All live parts, bus bars,VCBs connections of RMU should be enclosed in SF6 insulated stainless steel enclosure (2 mm thick, SS304 grade) one tank to avoid multiple interconnections & sealed for life robotically welded non magnetic having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200.The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as Terminal kits suitable for 1Cx300sqmm Cable, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external bus bar .The unit shall include the following with all necessary standard fitting required at site. RMU, Breaker & VI Shall be of same make for easy maintenance.
Make of RMU: ABB, SIEMENS, SCHNEIDER INFRA. (RMU shall be manufactured by OEM itself & not by the franchise / license partner )
Each VACUUM CIRCUIT BREAKER of RMU
630A VCB module for making & breaking of fault current alongwith Earth Switch of full making capacity-1 Nos.
Motor operated 630 A Vacuum circuit breaker having spring stored mechanism.
Three position disconnector/earthing switch downstream vacuum circuit-breaker.
Three position single spring mechanism for disconnector/earthing switch
“Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings.
Short time breaking current - 21KA/ 3 sec
Making Capacity - 52.5KA | 1 | Each | - | - |
| 4.01 | Ser No 4.00 contd...
VCB must confirm operating sequence 0-0.3sec-CO-3Min-CO and suitable for 10000 mechanical operation.
Power frequency withstand voltage - 38KV
Impulse withstand voltage - 95KV
Nominal operating gas pressure - 1.4 Bar abs.
Front cover mechanism - IP2X
Electrical and mechanical interlock to keep always one incomer ON & another Incomer OFF.
Green(ON)/Red(OFF) push buttons to operated VCB.
3O/C + 1E/F Self powered numerical protection relay with Low and High set for Over current and Earth Fault.
Auxiliary relays for OTI,WTI,Bucholz -Alarm & Trip for Outgoing VCBs.
1 x Lockout relays (86) for Transformer protection scheme..
Multifunction meter.
RMU Gas Tank and cable chamber should be tested for an internal arc fault of 21kA for 1 sec with AFLR classification
Resin cast ring core protection CT on cables 100-50/1A, 5P10, 2.5 VA - 3 Nos
Resin cast ring core metering CT on cables 100-50/1A, Cl-1.0, 2.5 VA - 3 Nos
Mechanical ON/OFF/EARTH/Spring charge Indication
Cable boxes should be Arc Proof interlocked with respective Earthing Switches.
Bus Connected equipment / metering cubicle consisting of following
3 nos. Single Phase PTs - 11kV/V3/110/V3 ,Cl-1.0 ,20VA
1 nos. Single Phase Aux PTs - 11kV/230V ,500VA
Space Heater with thermostat
Terminal Blocks
Battery/Charger-Minimum 12AH Capacity, 24V DC . Input Voltage of 230VAC from Aux PT Hooter.
Note :- The quoted rate shall include PCC platform as per size of RMU & as per design submitted by the manufacturer. | - | - | - | - |
| 5 | Supply, installation, testing & commissioning of 11 KV outdoor type (IP54) RMU dust and vermin proof, with locking arrangement duly powder coated, totally enclosed, free standing floor mounting type, compartment based type one side-extendable 5-way Ring Main Unit floor mounted with internal copper bus bars, consisting of 5 nos. fixed type motorised Vacuum Circuit Breaker (3 Incoming & 2 Outgoing) with additional BUS PT metering module. All live parts, bus bars, VCBs connections of RMU should be enclosed in SF6 insulated stainless steel enclosure (2 mm thick, SS304 grade) one tank to avoid multiple interconnections & sealed for life robotically welded non magnetic having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200.The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as Terminal kits suitable for 1Cx300sqmm Cable, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external bus bar .The unit shall include the following with all necessary standard fitting required at site. RMU, Breaker & VI Shall be of same make for easy maintenance.
Make of RMU: ABB, SIEMENS, SCHNEIDER INFRA. (RMU shall be manufactured by OEM itself & not by the franchise / license partner )
Each VACUUM CIRCUIT BREAKER of RMU
630A VCB module for making & breaking of fault current alongwith Earth Switch of full making capacity-1 Nos.
Motor operated 630 A Vacuum circuit breaker having spring stored mechanism.
Three position disconnector/earthing switch downstream vacuum circuit-breaker.
Three position single spring mechanism for disconnector/earthing switch
“Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings.
Short time breaking current - 21KA/ 3 sec
Making Capacity - 52.5KA | 1 | Each | - | - |
| 5.01 | Ser No 5.00 contd...
VCB must confirm operating sequence O-0.3sec-CO-3Min-CO and suitable for 10000 mechanical operation.
Power frequency withstand voltage - 38KV
Impulse withstand voltage - 95KV
Nominal operating gas pressure - 1.4 Bar abs.
Front cover mechanism - IP2X
Electrical and mechanical interlock to keep always one incomer ON & another two Incomer OFF.
Green(ON)/Red(OFF) push buttons to operated VCB.
3O/C + 1E/F Self powered numerical protection relay with Low and High set for Over current and Earth Fault.
Auxiliary relays for OTI,WTI,Bucholz -Alarm & Trip for one Outgoing VCBs.
1 x Lockout relays (86) for Transformer protection scheme for one outgoing VCB..
Multifunction meter.
RMU Gas Tank and cable chamber should be tested for an internal arc fault of 21kA for 1 sec with AFLR classification
Resin cast ring core protection CT on cables 100-50/1A, 5P10, 2.5 VA - 3 Nos
Resin cast ring core metering CT on cables 100-50/1A, Cl-1.0, 2.5 VA - 3 Nos
Mechanical ON/OFF/EARTH/Spring charge Indication
Cable boxes should be Arc Proof interlocked with respective Earthing Switches.Bus Connected equipment / metering cubicle consisting of following
3 nos. Single Phase PTs - 11kV/V3/110/V3 ,Cl-1.0 ,20VA
1 nos. Single Phase Aux PTs - 11kV/230V ,500VA
Space Heater with thermostat
Terminal Blocks
Battery/Charger-Minimum 12AH Capacity, 24V DC . Input Voltage of 230VAC from Aux PT Hooter.
Note :- The quoted rate shall include PCC platform as per size of RMU & as per design submitted by the manufacturer. | - | - | - | - |
| 6 | Excavating in trenches in hard / dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of cable etc not exc 10 Sq mtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and directed. | 56 | Cum | - | - |
| 7 | Returning , filling in , including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed. | 38 | Cum | - | - |
| 8 | Removing excavated surplus soil to a distance upto 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. | 18 | Cum | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
SP35Tender.pdf
Tender Documents • 0.69 MB
CreditFinal.pdf
Tender Documents • 0.13 MB
BOQ_880210.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].