spectrum analyzers vector network analyzers Spectrum Analyzers Vector Network Analyzers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Description of the itemuu Spectrum analyzers Spectrum analyzers
Two port vector network analyzers(with spectrum analyser)
Two port vector network analyzers (without spectrum analyser) GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Markers Normal
delta - Trigger Free run
video
External - Display TFT Colour display with provision for three traces - Interface USB - Software for transfer of screen shot/measurement data to PC Yes - SPECTRUM ANALYZER FEATURES Frequency Range 9 kHz to 3 GHz 9 kHz to 3 GHz
9 kHz to 7 GHz
9 kHz to 13 GHz
100 kHz to 18 GHz
9 kHz to 26.5 GHz
9 kHz to 40 GHz
9 kHz to 6 GHz
NA 1/6 Aging rate of spectrum analyzer frequency: Better than 1x10-6 Year Yes - Frequency counter Resolution(minimum) (Hz) 1 - Frequency Span 100Hz to 3GHz As per GeM Catalogue. Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz Yes - Spectral purity:Harmonics @ -40dBm level <=60 dBc yes - Sweep time @span >or= 1 KHz 0.1S to 1000 s - Sweep time @span = 0 Hz 100 micro S to 20 S - Resolution Bandwidth (-3dB) 10 Hz to 3 MHz in steps - Video Bandwidth 10Hz to 1 MHz in steps - Amplitude : Max input level for protection (dBm) +30 - Amplitude : Max input level for measurement (dBm) 20 - Amplitude :level measurement uncertainity (dB) <=2 - Average noise level dis played(@300HzRBW
10 Hz VBW) <=-110dBm for 10MHz to 3 GHz - Average noise level dis played(@100HzRBW
1 Hz VBW) <=-110dBm for 10MHz to 3 GHz - Average noise level dis played(@300HzRBW
1 Hz VBW) <=-110dBm for 10MHz to 3 GHz - Measurement features C/N ratio
AM%
time domain power measurement
channel power measurement
Phase noise measurement
TOI (THIRD ORDER INTERC EPT)
OBW(occupied - 2/6 bandwidth) VECTOR NETWORK ANALYZER FEATURES Frequency Range for 2port vector network analyzer NA - Frequency Resolution (CW ON) (Hz) NA - Return Loss (dB) NA - VSWR (dB) NA - Cable Loss (dB) NA - Calibration with Precision calibration components-open
short
load should be included to achieve directivity >35 dB NA - Abilty to locate Distance-to-fault in Co- axial cables NA - Phase Range (degree) NA - Phase Resolution (deg) NA - RF output port NA - Dynamic Range NA - Nominal port power output: Hi Power/Lo- Power selectable NA - Power levels corresponding to Hi and Lo levels NA - Measurement of S11 and S21 and Smith Chart NA - Vector Voltmeter for comparision and verification of the phase of the phase- matched cables NA - Group Delay measurement NA - OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C '5 to 40 degree C & 80% RH @ 40 degree C Operating Humidity 80% RH @ 40 degree C 80% RH @ 40 degree C POWER REQUIREMENT Power requirement 230 +- 10 VAC
50Hz
Rechargeable battery 230 +- 10 VAC
Rechargeable battery chemistry of the battery lithium ion - 3/6 Voltage of rechargeable Battery 10.8 - capacity of rechargeable battery (millAh) 7500 - Suitable charger adaptor provided Yes - WARRANTY Warranty 3 1
2
3
4
5 ACCESSORIES Details of Standard accessories covered in the scope of supply 2000-1654-R Soft Carrying Case
2000-1691-R Stylus with Coiled Tether
2000-1797-R Screen Protector Film
8.4 inch (2
one installed)
633-75 Rechargeable Li- Ion Battery
40-187-R AC-DC Adapter
806-141-R Automotive Power Adapter
12 VDC
60 W
3-2000-1498 USB A/5-pin mini-B Cable
10 ft/305 cm - GENERIC Other features Features - Pre- Amplifier
Field Strength Measurement capability
AM/FM/SSB Analysis
6 dB EMI Bandwidth/QP Detection
VSWR
RL
DTF
Cable Loss
1-port Phase Measurement
Smith Chart Impedance measurement. Field- proven design Three- hour battery life
rugged
compact
lightweight
daylight viewable display. Intuitive menu-driven touchscreen user interface. Standard three-year warranty battery one-year warranty. Measurements Occupied Bandwidth
Channel Power
ACPR
C/I
Spectral Emission Mask. Dynamic Range 95 dB in 10 Hz RBW. DANL -152 dBm in 10 Hz RBW. Phase Noise - 4/6 -100 dBc/Hz max @ 10 kHz offset at 1 GHz. Save-on-Event. Cable and Antenna Analyzer 2 MHz 4 GHz. Return Loss
Distance-To- Fault. Phase
2-port Transmission Measurements. 2000 Traces and setups can be stored internally. CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest no - conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest no - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH no - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test - - Name and address of the Lab for the specification test - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashish Dey 764005
All India Radio
Jaynagar
Jeypore 1 15 5/6