Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.4 CrAccepted-AOC 201 202 2ND FLOOR FITWELL HOUSE OPP HOME TOWN LBS MARG VIKHROLI W MUMBAI 400083 | MUMBAI SUBURBAN | MAHARASHTRA | 400083 | ₹56.4 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹59.6 CrRejected-Finance C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | ₹59.6 Cr | L2 | Rejected-Finance Not lowest |
| 3 | L3₹60.3 CrRejected-Finance HOUSE NO 59 ZOO NARENGI ROAD GEETANAGAR GUWAHATI 781021 ASSAM | KAMRUP METRO | ASSAM | 781021 | ₹60.3 Cr | L3 | Rejected-Finance Not lowest |
| 4 | L4₹66.6 CrRejected-Finance CITY TOWER BUILDING ROOM NO 306 CIRCULAR ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | ₹66.6 Cr | L4 | Rejected-Finance Not lowest |
| 5 | L5₹67.9 CrRejected-Finance | ₹67.9 Cr | L5 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
13 Sept 2025, 6:00 pmClosed
Cheif Engineer Shillong
Chief Engineer Shillong Shillong Zone Spread Eagle Falls Shillong 793011
PROVN OF DEFI MD ACCN (PH-I OF TWO PHS) AT NARANGI MILITARY STATION UNDER GE GUWAHATI.
2025_MES_704312_1
89813/GUA/E8
Open Tender
Civil Works
910 days
GE GUWAGATI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
GE GUWAHATI
₹15 L
Yes
9 Oct 2025
12 Apr 2025
15 Sept 2025
21 Jul 2025
13 Sept 2025
8 Sept 2025
Amount
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE 'A' PART I (A) DESIGN & BUILD STRUCTURE
Design & Construction of a Md Accn for 24 Major and above with Servant Quarter and Baggage Room , G + Six Storey, in RCC framed structure, water proofing treatment to roof, Mosquito proofing, seismic consideration of Zone "V" including stilt Car parking and Ramp alongwith 25000 Ltrs additional RCC fighting tank on roof complete all as specified and as shown on drawings No. CESZ/NAR/2025/LP-166 Dt-11.02.25 Sheet No: 2/3 .
Design & Construction of a Md Accn for 24 JCO's with Baggage Room , G + Six Storey, in RCC framed structure, water proofing treatment to roof, Mosquito proofing, seismic consideration of Zone "V" including stilt Car parking and Ramp alongwith 25000 Ltrs additional RCC fighting tank on roof complete all as specified and as shown on drawings No. CESZ/NAR/2025/LP-166 Dt-11.02.25 Sheet No: 1/3 .
Design & Construction of a Pump House , Single Storey, in RCC framed structure, water proofing treatment to roof, seismic consideration of Zone "V" complete all as specified and as shown on drawings No. CESZ/NAR/2025/LP-166 Dt-11.02.25 Sheet No: 3/3 .
Design & Construction of a Guard Room , Single Storey, in RCC framed structure, water proofing treatment to roof, Mosquito proofing, seismic consideration of Zone "V" complete all as specified and as shown on drawings No. CESZ/NAR/2025/LP-166 Dt-11.02.25 Sheet No: 3/3 .
Design & Construction of a RCC UG Sump 14000 Gallon capacitycomplete all as specified and as directed.
Design & Construction of a RCC UG Sump 20000 Gallon capacitycomplete all as specified and as directed.
SCHEDULE A PART I (B) PREPRICED BUILDING SSR
Lumpsum price worked out by the tenderer for BUILDING & STRUCTURE WORK as listed in Schedule ‘A’ Part-I(B)
Lumpsum price worked out by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for AVIATION LIGHT as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for ROAD/PATH/CULVERTS/HARD STANDING as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for BOUNDARY WALL AND GATE as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for RETAINING WALL as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for FIRE FIGHTNING SYSTEM as listed in Schedule ‘A’ Part-XII
SCHEDULE 'A' SEC-XIII (MISCELLANEOUS ITEMS) NOTE: THIS SCHEDULE IS NOT PRE-PRICED BY MES AND THE PRE-PRICED RATE INDICATED AS "RS 0.00" UNDER COL. 5 SIGNIFIES THIS FACT ONLY.
Bringing approved earth (as approved by Garrison Engineer) from sources outside defence land including all costs such as royalty if any transportation taxes etc. for area filling / forming including raising earth spreading in layers not exc 30 cm thick each layer, watering, compaction with 8 tonne to 12 tonne power roller and finished to required size and shape etc, any high / depth from EGL. Notes:- (i) Earth required for the item shall be supplied by contractor out side MOD land of any lead at his own arrangement. (ii) All cost of procurement of earth including cost of transportation, compaction, royalties, tax etc. shall be deemed to be included in the unit rate quoted by the contractor. (iii) with reference to clause 3.6 of MES schedule Part-II on serial page no- 21 it is clarified that measurement of the above item shall be finished embankment/ traverse of filled earth after consolidation/ compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk. (iv) Total quantity/ partial of earth may not be available in Guwahati area. The contractor shall bring the earth outside area it is advised to quoted the rate considering availability of soil and its lead involved complete all as specified and as directed.
M&L for RCC Septic tank 150 users with upflow filter type designated to carry sewage and sullage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc, complete with effective depth 1.5 m and over all depth of 3 m for complete all specified and shown on drawing No CESZ/2020/STD-02 Sheet 1/2 to 2/2
M&L for Construction of Brick Masonry SOAK WELL OF SIZE 2.40 M DIA & 4.50 M DEPTH with all fittings and fixtures complete all as specified and shown on drawing No. SZ/2020/TD/45 sheet 1/2 to 2/2
Construction of Brick Masonry SOAK WELL OF SIZE 1.2 M DIA & 3.00 M DEPTH with all fittings and fixtures complete all as specified and shown on drawing No CESZ/2020/TD/45 sheet 1/2 to 2/2
M&L for LLDPE septic tank for 10 users conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, vent shaft, connection etc., complete all as specified and as directed.
S & F Steel gate 5.5 m wide, 1.40 m high:- Excavation, PCC (1:4:8) type D-2 as in foundation, M-25 RCC post, 15mm plaster in CM (1:6) MS work, painting, Three coats in white wash on RCC post etc. including returning filling and removal of surplus soil complete all as specified and shown on drawing No. CESZ/TD/2017/34.
S & F Steel gate 5.5 m wide, 2.10 m high:- Excavation, PCC (1:4:8) type D-2 as in foundation, M-25 RCC post, 15mm plaster in CM (1:6) MS work, painting, Three coats in white wash on RCC post etc., including returning filling and removal of surplus soil complete all as specified and shown on drawing No. CESZ/TD/2017/34.
Design Engineering & SITC of Compact & concealed Designed 35 KLD sewage Treatment Plant based on Johkasou technology Modular Pre Constructed systems, including operation and maintenance for a period of 5 year from date of completion of work including all consumable except power with adequate manpower to ensure no downtime of plant and provide consistent outlet parameter, the plant shall be have least energy and operating cost and no noise during operation (all as per Technical specification and Particular specification attached) complete all as specified and as directed.
M & L for pcc 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in bed for drain pipes 450 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
S & F intregral LED 4ft luminaire of CRCA / extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a 18 Watt LED with colour consistency SDCM< 5,CRI> 80 and colour temperature - 4000 to 6500K, Luminaire shall be designed to emit at least 2000 nominal lumens at a system efficacy of at-least 120 lumen/watt, power consumption should not be more than 18W (+5%). the life of fixture (including Driver): 50000 burning Hrs.@ L70B50 Lumen maintenance @ design ambient temp 50 deg C. The electronic driver used shall have a power factor >0.95 and THD < 10% suitable for an operating voltage range of 150-270V AC current Ripple<5% internal surge protection should be minimum 2.5KV, electrical insulation class should be Class I &driver should be of class B serviceability. The luminaire should be at least IP20 & IK02 rated. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have in house NABL accredited lab conduct LM79, type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for luminaire manufacturer along along with sample approval. The LED Luminaire & It's driver both should be BIS registered contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer type test certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and as directed.
Supply Installation, testing & comissioning Integral / batten LED 2ft, 10 watt 220 V, luminaire made of CRCA/extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit at least minimum 2000 system lumens at a system efficacy of at-least 120 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant.The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with sample approval. The LED Luminaire & it's driver both should be BIS registered. Contractor shall submit the following reports before supply of sample approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and as directed.
S&F LED type wall mounted light fitting suitable for LED lamp 20w, housing glass, frosted type, metalic frame complete all as specified and as directed. Make : Philips Cat No 31453, 20watt wall light or equivalent make specified in make list.
S&F LED Surface mounted Downlighter having dia of 153mm(± 3mm) & height of 60mm(± 3mm) delivering minimum system lumen output of 1500 lumens (±5%) and system wattage of 15W (±5%) & with a minimum system efficacy of 110 lm/W. The luminaire should have a color temperature of 6500°K, CRI≥80 and SDCM≤5. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing should made of pressure die-cast aluminum. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The the successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Technical bid. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire.
S & F Bldg security light fittings high-quality group control enabled integrated LED Building security Light with a minimum system lumen of 3000 lm and system wattage not exceeding 25W with a nominal system efficacy of 110 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 75K hours@L70. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The LED used in the luminaire shall be SMD type only. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with sample approval. The LED Luminaire & it's driver both should be BIS registered. contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver and including 1.2m long 32mm dia GI pipe light grade bend to shape and fixed using two nos clamps fabricated using MS Flat iron 40x5mm including necessary nut bolts and washers and making electrical connection using 1.5sqmm, 3 core multi-stranded copper conductor PVC insulated and over all PVC sheathed cable form light fitting complete all as specified and as directed
S & F Wall mounted type fans of 200 mm sweep, 03 blades aerodynamically balanced with 60 degree oscillation, working Voltage range 230 V, with service value not less than 1.2 BEE 5 star rated with brush less direct current motor(BLDC), the super efficient BLDC motor 50Hz and Noise level not more than 64 dB with 2 years warranty complete all as specified and as directed.
M & L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded FRLSH type 1100V grade 2 x 4 sqmm complete drawn in new PVC concealed conduit 20mm dia and its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor multi stranded FRLSH type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and as directed. Note: (i) 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with PVC conduit altogether shall be measured as one unit. (ii) Sub main wiring for Car charging socket shall be connected from outlet of energy meter to SPN DB of Car Charging socket of respective occupant shall be installed in Garage at ground floor Car parking of respective occupant.
M & L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded FRLSH type 1100V grade 2 x 6 sqmm complete drawn in new PVC concealed conduit 25 mm dia and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor multi stranded FRLSH type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and as directed. Note: (i) 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with PVC conduit altogether shall be measured as one unit.
M & L for perforated cable tray of size 75 x 50mm standard type C, made out of hot dip galvanised sheet having thickness not less than 1.6 mm thick fixed on wall upto 7th floor high building including necessary bracket for fixing and all accessories like bend, elbow, etc complete all as specified and as directed.
S & F Modular blanking plate modular type suitable for fixing in modular switch board, complete all as specified and as directed.
S & F power unit suitable for upto 2.0 ton Air Conditioner having push ON-OFF push button switch, motor starter type, single phase, 4 module with and including modular metal flush box with cover plates complete all as specified and as directed.
S & F modular socket 2 module, 25 Amps , including modular switch 20 Amps/25 Amps one way , 1 module with and including three module metal flush box with cover plates and the socket shall be housed in locking arrangement made of metal sheet and flushed in wall complete all as specified and as directed.
S & F Modular Telephone socket RJ 11 suitable for housing modular frame plate complete all as specified and as directed.
S & F Modular TV socket RJ 46 suitable for housing modular frame plate complete all as specified and as directed.
S & F Surge Protection Device (SPD) single phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in distribution board and making connections complete all as specified and as directed.
S & F Surge Protection Device (SPD) 4 module, 25 KA, 3Ph+N Right, T1+T2, limp 8 KA per pole, T2-60KA, complete fixed in Essential DB and making connections by using necessary thimble/washers etc of copper/brass material complete all as specified and directed.
S&F digital time switch 2 module, with Astronomical Function for switching ON/OFF lights according to sun rising/ sun setting, with combination function for creating switching programs in which the devices are switched according to astronomical time and/ or fixed preset times, having daily astronomical calculation of the sunrise/sunset times based on the entered location or location coordinates complete having 2 output 16 AMps, 250 volts, 50 HZ, Astronomical function 2x28 programs 2 channel, suitable for din rail mounting in essential DB complete all as specified and as directed.
M & L for earthing in replacement complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cm X 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I. complete all as specified and as directed.
S&F Hot water storage (Geyser) 25 Liters capacity, BEE 5 Star rated, vertical type, digital temperature display with suitable size of fasteners and including provision and connecting up of SS Braided pipe with adopter for inlet and outlet water connection, copper element corrosion resistant antiscaling magnesium anode, having adjustable knob for temperature control and inner tank material of superior glass line coating / porcelain enamel coating / Titanium Enamel coating / Nano Blue Diamond Glass Coating / Coating with single weld line tank and outer body material ABS with high pressure withstanding capacity upto 8 bar pressure, Multiple safety systems for protection against dry heating, overheating and over pressure, IPX4 waterproof technology for longer product life having heating element 2 KW and minimum two year warranty on product, minimum 3 year warranty on heating element , and 5 year warranty on tank complete all as specified and as directed.
Supply, Installation, testing and commissioning of Package type/ unitised 11KV/433V Outdoor Sub-station, 250 KVA made from GI enclosure complete as required confirming to IEC 62271-202 only and relevant IS specifications including K-10 temperature class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 PCC foundation of suitable size extending 500mm all around the outdoor enclosure and 1000mm height (above the ground level ) complete with suitable sizes of GI pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40X40X5 mm MS all along with the corner of the foundation od CSS shall be from OEMs only. Licensed System Integrators of approved OEM are not allowed to supply . Package Substation will have the following equipment :- HT Switchgear :- 11 KV 630 Amps 21 KA / 3Sec Non Extensible Ring Main Unit Compact Switchgear consisting of direct cable module & 1 No motorized Circuit Breakers Module in SF6 insulated stainless enclosure with series trips, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through IC x 95 sq. mm Aluminium XLPE cable - 1 No. Vacuum Interrupter & RMU shall be of same make to ensure life cycle optimization. Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint. Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder. SF6 Gas pressure indicator. Operating sequence of VCB must be O-0.3sec-CO-3 Mins CO - Protection CT shall be minimum 40/1A, 2.5VA, 5P10 - 3 nos. All modules of the RMU shall be suitable for cable termination of 3C x 95 Sq.mm AI XLPE Cable, incoming cable termination is included within the scope of work - 1 set.
Contd/--- TRANSFORMER: - 11/0.433KV, 250KVA, 50Hz, Off load Tap Changer switch, Three Phase, natural ester oil type transformer in corrugated tank (i) Standard IS : IS : 2026 and IS 1180 with latest amendments (2021) (ii) Losses as per 1180 level 2 and Temperature rise shall be as per IS 1180 with latest amendments (iii) Outdoor Installation (iv) Vector group : Dyn 11 (v) Rating 250 KVA (vi) Cooling System : KNAN (K for Ester oil) (vii) Winding ; Copper (viii) Magnetic Core : Prime grade of M4 or better (ix) High voltage : 11 KV - 50 Hz (x) Low Voltage : 433 V - 50Hz (xi) System highest Voltage : 12 KV at the HV side (xii) Percentage Impendence Value : As per IS 1180 (xiii) Manufacturing testing laboratory to be NABL certified with in house core cutting facility for proper control & monitoring of quality & to avoid mixing of prime core with second grade / defective core materials (xiv) Insulation Level : HV Power Frequency (KV rms) : 28 KV HV, Impulse withstand voltage (KV peak) : 75 kVp (xv) Tapping : +5% to -15% OLTC @ 2.5% (xvi) HT Termination - Cable Box (xvii) LT termination - cable box and with all accessories i.e. first filling of filtered dehydrated oil and confirming to ID & standard accessories required.
Contd/----- (ii) The APFC Panel shall have 10% extra space for future expansion. (iii) The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerance, typical GADs, etc for approval of the Garrison Engineer. (iv) The Capacitor bank shall be internet of things (IoT) enabled and communicable / intergrable with EMS. The APFC panel should have the capability for environmental monitoring where it is able to provide the real time data for the temperature and humidity inside the panel ambient. The environmental sensors shall be used with a access point, which can be used for multiple sensors, using Green Power wireless communication protocol to transfer the information on real time basis the exact and detailed temperature monitoring. All Civil works such as PCC/RCC foundation, Platform, Filling trench and pedestal etc as per CSS manufacturer's recommendation are included in scope of work. OUTDOOR ENCLOSURE Outdoor type enclosure of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable designed for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitably handling any arcing inside the compartment illumination lamp with door operated switch shall be provided for each compartment.
Supply, install, test and commission LT Feeder panel, TPN 415 Volts, 50 Hz, out door cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventilation including suitable size of cable alley aluminium bus bar suitable for carrying of current 600 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- ( For JCO block) (a) MCCB 400 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 35 KA - 1Nos (Incoming). (b) MCCB 160 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 25 KA - 3 Nos (Outgoing). (c) MCCB 16 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 18 KA - 1 Nos (Outgoing). (d) 3Ph digital multifunction meter model A, class 1, 5A with relay Vega Series - 1Nos (e) Indicating lamp 240 volts LED type - set of three.
Supply, install, test and commission LT Feeder panel, TPN 415 Volts, 50 Hz, outdoor cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventilation including suitable size of cable alley aluminium bus bar suitable for carrying of current 500 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- ( For Offrs block) (a) MCCB 315 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 35 KA - 1Nos (Incoming). (b) MCCB 250 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 25 KA - 2 Nos (Outgoing). (b) MCCB 16 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 18 KA - 1 Nos (Outgoing). (c) 3Ph digital multifunction meter model A, class 1, 5A with relay Vega Series - 1Nos (d) Indicating lamp 240 volts LED type - set of three.
Supply, install, test and commission LT Feeder panel, TPN 415 Volts, 50 Hz, outdoor cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventilation including suitable size of cable alley aluminium bus bar suitable for carrying of current 100 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- ( For stand by supply to Offrs block, JCO Block) (a) MCCB 63 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 25 KA - 1Nos (Incoming). (b) MCCB 20 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 18 KA - 4 Nos (Outgoing). (c) Supply and fix time control switches 415 V three phase for S/ light: 01 No (d) 3Ph digital multifunction meter model A, class 1, 5A with relay Vega Series - 1Nos (e) Indicating lamp 240 volts LED type - set of three.
M & L for cable PVC insulated industrial flexible FR 1100 volt grade with stranded copper conductor of size 1.5 sqmm 3 core in suitable PVC conduit complete all as specified and as directed.
M & L for Loop in Loop out box of FRP of min size 240mm x 130mm x 110mm made with IP65 Protection of thermoplastic breaker box with metric knock out for cable entry & exist , cable glands IP 66/67 for cable enrty IP 65 for conduit for cable terminal and PVC connector heavy duty 32 Amp 4 Way for cable with necessary fixing arrangement and cable gland etc complete all as specified and as directed.
S & F LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 4900 lm and system wattage not less than 35W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including with necessary brackets / pipes clamps & nuts & bolts for holding the street light fitting and three core copper flexible cable of 1.5 Sqmm as required at site. The product complying to above specs in signify, LT or Endo (Philips/Havells/Wipro/regent) complete all as directed.
Supply, install, test and commissioning of Street Light Panel of 6 KW capacity , TPN 415 Volts, 50 Hz, outdoor cubical type floor mounted, factory made, double door dust and vermin proof IP-54 protection, fabricated out of CRCA sheet duly powder coated fixed on angle iron pedestal made out of 40x40x6 mm with cable chamber for individual feeders for incoming and outgoing connections, including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the street light panel complete all as specified and directed comprising of the following :- (a) Range : 6 KW (b) Conforms to IS /IEC 60947-4-1 (c) Provided with Protection Degree IP-54 (d) Extended wide band coil (e) FRLS internal wiring (f) In-built Short-circuit Protection (g) Class H Insulation (h) Contractor Rating - 32 A TP (j) MCB Rating - 40 A TPN (k) Time Switch - Astronomical
Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 40 KW (50 KVA), 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Narangi (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB IV guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 6 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 40 KW(50 KVA) at outdoor atmospheric conditions at Narangi, (Taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including selfstarter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . (ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 40 KW(50 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.
Note: PCC foundation for DG Set shall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department (b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge (d) One set of latest Spare part catalogue with price, exploded view of parts and user's manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer's drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil.
Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 16 KW (20 KVA), 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Narangi (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB IV guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 6 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 16 KW(20 KVA) at outdoor atmospheric conditions at Narangi, (Taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . (ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 16 KW(20 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.
Note: PCC foundation for DG Set shall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department (b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge (d) One set of latest Spare part catalogue with price, exploded view of parts and user's manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer's drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil
Supply, installation, Testing and commissioning of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of Polyamide roof cable holder for flat roof : DIn 48829 form B1 closed form with bottom, filling weight 1 Kg (frost resistant concrete), sleeve from polyethylene, black . Conductor holder @ 1 meter distance along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of 2 metre vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305 part-3 Nominal size Ø 10/16 mm aluminium rod, semi hard (E-AlMgSiO5 corresponds to DIN 48801) suitable for high wind load complete with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of stand for fang fix system 16 Kg with base and clamp, nominal size 360mmx80mm made up of frost resistant concrete and tested upto 100KA lightning current complete with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of stand for fang fix system 16 Kg with base and clamp, nominal size 373mmx83.5mm made up of frost resistant concrete and tested upto 100KA lightning current complete with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of cross universal connector for T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of expansion piece with connector for equalising temperature related length changes. Necessary on conductors length over 30 meters for round conductor Rd 8/ALU along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of Connector for T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of Bridging cable from flexible CU cable of 16Sqmm with black colour coating, chlorinated India rubber mixture. Exclusively used for indoor & outdoor application to make continuity at terminals with along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of Bridging cable: From flexible CU cable of 16Sqmm with black colour coating, chlorinated India rubber mixture. Exclusively used for indoor & outdoor application to make continuity at terminals with 3198 Clamping Shoe, 8 mm (5325307) along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of 10mm dia solid, round conductor with 100 micron copper coating along with necessary accessories as recommended by OEM / Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of Connector for T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised along with necessary accessories as recommended by OEM/Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of Cross connector for earth fixing point suitable for FL 30. Installed with 2 hexagonal bolts along with necessary accessories as recommended by OEM/Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of Earth fixing point along with necessary accessories as recommended by OEM/Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of Connector for T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised along with necessary accessories as recommended by OEM/Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of 10mm dia solid round conductor with 100 micron copper coating along with necessary accessories as recommended by OEM/Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of rubber clamp suitable for 50x6mm dia Copper strip at every 3m along with necessary accessories as recommended by OEM/Manufacturer complete all as specified and as directed.
Supply, installation, Testing and commissioning of Connector for T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised along with necessary accessories as recommended by OEM/Manufacturer complete all as specified and as directed.
Design, Supply, Installation, Testing and commissioning incl comprehensive maintenance for 5 years of Roof Top Solar Power Generation Plant of capacity 30 KW (minimum 36 KWp) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications as Detail Brief Report and Technical Specification for SPV Plant complete all as specified and as directed.
Design, Supply, Erection, Testing and commissioning incl comprehensive maintenance for 5 years of Roof Top Solar Power Generation Plant of capacity 10 KW (minimum 12 KWp) at output Voltage 415 Volt, 50Hz, ON GRID Hybrid solar roof top with batteries back up for captive use as per specification & complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications as Detail Brief Report and Technical Specification for SPV Plant complete all as specified and as directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured , electric control cables (Heavy Duty) with stranded copper conductor of size 1.5 Sqmm, 2 Core, 1100 Volts grade complete all as specified and as directed.
S & F solid state electronic type aviation obstruction light fitting twin dome type having 302 Nos LED for 10 wattage system in each dome complete with cast aluminium, poly carbonate red colour with connecting & testing complete all as specified and as directed.
Supply, installation, testing and commissioning of stainless steel electric kitchen chimney 90 cm with 1500 Cum/Hr suction intelligent auto clean wall, curved glass, baffle filter, motion sensor control, oil collector tray with inbuilt LED light including aluminium flexible pipe of 150 mm dia of suitable length with suction cover, with all accessories including making/cutting hole of 150mm dia suitable for aluminium exhaust pipe and making good complete all as specified and as directed.
Design, Supply, install, testing and commissioning of electrically operated machine room less (MRL) passenger lift of capacity 8 passenger lift (544 kgs Capacity) in the lift well, 1.5 m/s speed with automatic GIEN micro stroke button control, microprocessor based controller, simplex full collective control suitable for 3 phase, 50 HZ 415 volts AC supply independent operation with AC variable voltage variable frequency (AC VVVF) control closed loop with power saving regenerative drive with suitable motor and gear unit to serve ground plus six upper floors i.e with 7 stops and 7 landings with or with out attendant suitable for synchronised operation automatic power operated centre opening sliding stainless steel door with Moon Rock finish of 16 gauge (not less than 1.5 mm) with infra-red sensors all along the height for car door with automatic rescue/ levelling device (ARD) (with + or -5 mm) with suitable dry maintenance free batteries, haul position digital indicators in car and all landing with call indicating lights etc including necessary joists and beams for mounting machine in the machine room including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following : (Size of well available is 2100 mm x 1800 mm) Type of Drive: Regenerated AC variable voltage and variable frequency drive along with converter unit.The regenerated power shall be used to charge the battery of UPS, ARD and emergency lights. Type of Machine: Gearless permanent magnet and directly coupled to horizontal traction machine. Note 1: Counter weight shall be of cast iron block.
(a) Fire man switch. (b) Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. (c) Separate Battery operated emergency light (LED ceiling fitting ), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. (This system shall be separate from ARD batteries.) (d) Integrated Roof RL 20 Stainless Steel Ring Lighting LED (e) One sleek circular PVC heavy duty fan in false ceiling. (f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with 20 mm Recess & Granite Stone. Car skirting material: Brushed stainless SUS304 (g) Non stop button /independent operation (h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protection/tripping system). (j) Front landing door of stainless steel moon rock finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. (k) Car size shall be in conformity with IS -3534-1976 and body to be stainless steel of 16 gauge moon rock finish with stainless steel hand rail 38mm hairline finish (l) Limit switches as specified in IS
(m) Mirror of 6mm thickness of suitable size. (n) Hand rail 38mm hairline finish. (o) Opening with see through glass of 8 mm thick 200 x 600 mm size in all the doors (Car/Landing doors) (p) Specification plate with complete details. (q) Continuous earthing for machine and equipments. (r) Steel Wire rope of adequate size as per relevant IS and as per manufacturer specification (s) Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete. (t) Car operating Panel 1 Full Height Dark grey brushed St Tempering glass Segmented LCD display Round flush mounted KDS96 – stylish touch panel Landing Signalization-Tempered glass Segmented LCD display Flush Mounted Tempered glass Round flush mounted KDS96- stylish touch panel (u) Main drives and control shall be of latest, high effective and low power consumption. (v) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (w) Over load and floor announcement audio and visual arrangement.
Features Common to Specifications 1. Digital Direction & Position Indicator in Car and at all landings 2. Emergency Alarm at the main landing 3. Facia Plate 4. 2 Phase Fireman Drive, Fireman’s switch at the main landing. (In case Fireman Drive is activated the elevator will come to the main landing and open the door). 5. Advanced door operation (Ensures smooth opening & closing of the doors at adjustable door speed) 6. Additional Pressure Sensing Device 7. Load Weighing Device (Audio visual over load indicator in the car for better safety) 8. Full Height Infra-Red Curtain 9. Pit Ladder 10. Emergency Light, Intercom and Alarm with Maintenance Free Rechargeable Battery operation. 11. +6% To-10% Volt. Fluctuation Withstand Capacity 12. Over speed governor (Electro-mechanical device that prevents free fall in case the elevator is travelling at speed more than 10% of the rated speed in downward direction) 13. Automatic Rescue Device (To rescue the passengers in case of emergency- this device will bring the car to the nearest floor automatically and will open the doors). 14. Steel Ropes 15. Special Car Door Lock 16. Fire Rated Doors-2 hour. 17. Automatic Brake Testing. 18. PMS MOTOR with ECO Disk Drive 19. Linear Motor Technology & Close Loop Arrangement. 20. 24x7 Connected Services. 21. Car & Landing Doors –Moon rock finish
Design, Supply, install, testing and commissioning of electrically operated machine room less (MRL) passenger lift of capacity 13 passenger lift (884 kgs Capacity) in the lift well, 1.5 m/s speed with automatic GIEN micro stroke button control, microprocessor based controller, simplex full collective control suitable for 3 phase, 50 HZ 415 volts AC supply independent operation with AC variable voltage variable frequency (AC VVVF) control closed loop with power saving regenerative drive with suitable motor and gear unit to serve ground plus six upper floors i.e with 7 stops and 7 landings with or with out attendant suitable for synchronised operation automatic power operated centre opening sliding stainless steel door with Moon rock finish of 16 gauge (not less than 1.5 mm) with infra-red sensors all along the height for car door with automatic rescue/ levelling device (ARD) (with + or -5 mm) with suitable dry maintenance free batteries, haul position digital indicators in car and all landing with call indicating lights etc including necessary joists and beams for mounting machine in the machine room including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following : (Size of well available is 2100 mm x 1800 mm) Type of Drive: Regenerated AC variable voltage and variable frequency drive along with converter unit. The regenerated power shall be used to charge the battery of UPS, ARD and emergency lights. Type of Machine: Gearless permanent magnet and directly coupled to horizontal traction machine. Note 1: Counter weight shall be of cast iron block.
(a) Fire man switch. (b) Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. (c) Separate Battery operated emergency light (LED ceiling fitting ), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. (This system shall be separate from ARD batteries.) (d) Integrated Roof RL20 Stainless Steel Ring Lighting LED (e) One sleek circular PVC heavy duty fan in false ceiling. Make for (c) and (d) : Philips/ Bajaj / Havells / Crompton Greaves. (f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with 20 mm Recess & Granite Stone. Car skirting material: Brushed stainless SUS304 (g) Non stop button /independent operation (h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protection/tripping system). (j) Front landing door of stainless steel moon rock finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. (k) Car size shall be in conformity with IS -3534-1976 and body to be stainless steel of 16 gauge moon rock finish with stainless steel hand rail 38mm hairline finish (l) Limit switches as specified in IS
(m) Mirror of 6mm thickness of suitable size. (n) Hand rail 38mm hairline finish. (o) Opening with see through glass of 8 mm thick 200 x 600 mm size in all the doors (Car/Landing doors) (p) Specification plate with complete details. (q) Continuous earthing for machine and equipments. (r) Steel Wire rope of adequate size as per relevant IS and as per manufacturer specification (s) Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete. (t) Car operating Panel 1 Full Height Dark grey brushed St Tempering glass Segmented LCD display Round flush mounted KDS96 – stylish touch panel Landing Signalization-Tempered glass Segmented LCD display Flush Mounted Tempered glass Round flush mounted KDS96- stylish touch panel (u) Main drives and control shall be of latest, high effective and low power consumption. (v) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (w) Over load and floor announcement audio and visual arrangement.
Features Common to Specifications 1. Digital Direction & Position Indicator in Car and at all landings 2. Emergency Alarm at the main landing 3. Facia Plate 4. 2 Phase Fireman Drive, Fireman’s switch at the main landing. (In case Fireman Drive is activated the elevator will come to the main landing and open the door). 5. Advanced door operation (Ensures smooth opening & closing of the doors at adjustable door speed) 6. Additional Pressure Sensing Device 7. Load Weighing Device (Audio visual over load indicator in the car for better safety) 8. Full Height Infra-Red Curtain 9. Pit Ladder 10. Emergency Light, Intercom and Alarm with Maintenance Free Rechargeable Battery operation. 11. +6% To-10% Volt. Fluctuation Withstand Capacity 12. Over speed governor (Electro-mechanical device that prevents free fall in case the elevator is travelling at speed more than 10% of the rated speed in downward direction) 13. Automatic Rescue Device (To rescue the passengers in case of emergency- this device will bring the car to the nearest floor automatically and will open the doors). 14. Steel Ropes 15. Special Car Door Lock 16. Fire Rated Doors-2 hour. 17. Automatic Brake Testing. 18. PMS MOTOR with ECO Disk Drive 19. Linear Motor Technology & Close Loop Arrangement. 20. 24x7 Connected Services. 21. Car & Landing Doors – Moon Rock Finish
M & L for earthing with galvanised steel earth plate electrode of size 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32mmx6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer complete all as specified and as directed . Note : - Length of earthwire and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately.
S & Pressure Gauge suitable for 0-14 kg pressure range with 4" dial, die cast aluminium body with white background & black marking, 1/2" Male NPT threaded connection, suitable to work in service temp. of -20 °C to 80 °C having accuracy of ± 1 % FSD assembled with ball valve, nipple, socket, etc. for pump suction & delivery lines of fire pump sets near the flow switches complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable with copper conductor, 1100 Volts grade of size 6 Sqmm 3 core, conforming to IS 7098-1: 1988, having stranded copper compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and as directed.
M & L for earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized strip of size 25 mm X 4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, galvanized iron pipe of 40 mm diameter connected to earthing test point, all as shown in electrical plate No. 5, connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a 10 mm deep CI cover hinged to CI frame on ground level, GI watering pipe, funnel complete all as specified and as directed.
M & L for PN 1.6 rated 100 mm NB Cast irom (CI) 'Y' type strainer for suction conforming to IS 907: 1984 with SS filter screen and flange drilling standard end connection conforming to IS 1538: 1993 and necessary accessories for suction side of fire pumps complete all as specified and as directed.
M & L for PN 1.6 rated 100 mm NB Cast iron (CI) Sluice Valve, conforming to IS 14846: 2000 with cast iron body & bonnet, SS spindle & stem conforming to IS 6603: 2001, cast iron stuffing box, carbon steel stud / bolt / nut & washer, Hand wheel operated and flange end connection conforming to IS 1538: 1993 with necessary accessories complete all as specified and as directed.
Supply, installation, testing and commissioning of PN 1.6 rated 100 mm NB CI swing check type reflux (non return) valve, conforming to IS 5312-1: 2004 having cast iron body, cast iron bolted cover, nitrile rubber gasket, stainless steel hinge pin & body seat ring, renewable seat with premium quality rubber flap with flange drilling standard end connection conforming to IS 1538: 1993 and necessary accessories complete all as specified and as directed.
M & L for PN 1.6 rated air vent valve having brass body, cover, adopter, disc assembly & cap, stainless steel strainer, plastic float and 25 mm screwed threaded ends suitable for maximum operating temperature 100 °C installed on all high points in the water piping system to automatically remove the trapped air with necessary accessories complete all as specified and as directed.
S & F indoor type wall-mounted lockable hose cabinet of size 600 mm (H) x 800 mm (L) x 250 mm (D) suitable to house 2 Nos. of 15 m RRL hose and 2 Nos. branch nozzles, made of 18 gauge MS sheet with double door & 3 mm thick glazed glass with water proof rubber beading, red outside and white inside with two coats of enamel paint over a coat of primer, having "HOSE CABINET NO." painted on the inner face of the glass in 50 mm size block letter, including the cost of break glass box containing the key of the cabinet complete all as specified and as directed.
S & F swinging type 30 m long First Aid Hose Reel, conforming to IS:884-1969, having 19 mm NB thermoplastic reinforced hose reel tubing, conforming to IS 12585: 1988, 25 mm NB ball valve, stop cock, terminating with gunmetal coupling & nozzle of 6 mm NB outlet with shut-off valve, conforming to IS 8090: 1976 complete with MS socket for tap-off, red colour drum, brackets (including painting) for fixing on wall with anchor fastener, bolts, nuts, etc. complete all as specified and as directed.
S & F fire hydrant single outlet oblique type landing valve, conforming to IS 5290: 1993, having 75 mm NB (3") flanged inlet as per ANSI / IS 1538 (Part IV), brass spindle controlled 63 mm NB female instantaneous outlet type, gunmetal body, cast iron hand wheel, working pressure of 10.5 kg/cm2, seat test pressure of 16 kg/cm2, body test pressure of 30 kg/cm2 gunmetal coupling, ABS plastic blank cap, carbon steel chain, twist release type lug & all accessories including fixing and flanged tapping from stand post type fire hydrant complete all as specified and as directed.
S & F non-percolating rubber reinforced lined RRL hose type- A 15 m long fire hose of 63 mm NB size, conforming to IS 636: 1988, rated for bursting pressure of 35.7 kg/cm² complete with gunmetal male & female coupling conforming to IS 903: 1993, bound and rivetted to the hose pipe with copper rivets and 1.5 mm² copper wire complete all as specified and as directed.
S & F Orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and as directed.
S & F 150 rated three-piece design 25 mm NB Cast Steel (CS) Straight pattern ball valve, CL-1 conforming to IS 9890: 1981 and tested as per BS 6755-1, having Cast iron body, Stainless steel AISI 304 ball, renewable PTFE seat & gland packing, CS fastners & lever having screwed / socket weld end connection with accessories complete all as specified and as directed.
S & F Air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete fixed on top of suitable flange hydrant line complete all as specified and as directed.
S & f Electrically operated water pressure switch Universal type with necessary mounting/connection with control wiring with conductor and mechanical connection to operate at pressure range of 0 to 10 Kg/sqcm for automation complete all as specified and as directed.
Supply, installation, testing and commissioning of FM approved and UL listed microprocessor- based, true peer-to-peer networkable, Single loop addressable Fire Alarm Control Panel (FCAP) with its own microcontroller memory, communication module, fire device loop interface cards for intelligent initiating and indicating devices and peer-to-peer networkable with other addressable fire alarm panels. conforming to UL 2572 mass notification systems & NFPA 72, with required accessories complete all as specified and as directed. The FACP shall meet the following specifications / functional requirements. (i) The FACP shall have one isolated intelligent Signaling Line Circuits (SLCs) capable of connecting up to 99 detectors and 99 modules per SLC upto 200 detector and modules. (ii) The FACP shall have a degrade mode and the loops shall work in degrade mode in case of the CPU failure. (iii) The FACP shall have 640 character LCD backlit display/ Touch Screen display, full QWETRY program keypad, LED indicators viz. power; fire alarm; supervisory; system trouble; other event; signals silenced; point disabled; CPU failure; controls active; etc. membrane switch controls viz. acknowledge; signal silence; drill; system reset; lamp test; etc (iv) The FACP shall have four access levels, flash EPROM, 240 VAC power supply, automatic battery charger, 24 V sealed lead acid batteries, sufficient for 24 hrs normal working and 30 min in alarm condition. (v) The FACP shall have manual sensitivity adjustment up to nine levels, built-in alarm; trouble; security and supervisory relays, history file with 4000-event capacity in non-volatile memory plus separate 1000-event alarm-only file, keypad operation, LCD unit to indicate fire / fault signal of individual unit, in built printer to log all incoming data, etc. (vi) The FACP shall have integrated 8 channel digital voice evacuation system controller capable of broadcasting evacuation messages on the same peer-to-peer network, fire fighter's telephone two-way communication system capable of supervising all the speaker circuits with adequate zone control and accessories etc. Note : (i) The FACP shall be serviceable by any system integrator & shall not have dependency on specific system integrator. (ii) The FACP shall have feature to "ADD", "EDIT" & "DELETE" field devices like detectors & modules without dependency on PC / Software / Special tool / dongle.
Supply, installation, testing and commissioning of FM approved and UL listed surface / semi- flush mounted Dual Action Manual Pull Station "Push In & Pull Down" including an addressable interface for the intelligent FACP having built-in bicolour LED which is visible, flashing in normal operation and latching steady red in alarm condition, captive screw terminals wire-ready for easy connection to SLC loop complete all as specified and as directed.
Supply, installation, testing and commissioning of UL listed of Horn Strobe, wired as a primary notification appliance, flashing 75 cd at 1 Hz over the strobe's entire operating voltage range, xenon flash tube and associated lens / reflector system, built-in synchronization feature keeping strobes in sync for up to 30 minutes, horn producing audible annunciation of 75 dBA at 3 m distance complete all as specified and as directed.
Supply, installation, testing and commissioning of FM approved and UL listed addressable control module to provide FACP a circuit for notification appliances (e.g. Horns, Strobes, Horn Strobes, etc.) having built-in type identification, integral LED indicators, high noise immunity, SMES screws with clamping plates for wiring ease, direct-dial entry of address, etc. complete all as specified and as directed.
M & L for low smoke zero halogen (LSZH) flame retardant fire alarm cable of size 1.5Sqmm 2 core, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and as directed.
M & L for low smoke zero halogen (LSZH) flame retardant fire alarm cable of size 2.5Sqmm 2 core (supply to hooter/strobe), conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and as directed.
Supply, installation, testing and commissioning of FM approved and UL listed (fire fighter's) addressable Telephone Jack mounted to a single-gang electrical back box with suitable interface module for two way communication with the Central Fire Fighter Telephone Console complete with accessories complete all as specified and as directed.
Supply, installation, testing and commissioning of FM approved and UL listed Fire Fighter's Telephone Handset for two way communication with the Central Fire Fighter Telephone Console complete with accessories complete all as specified and as directed.
S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, dry chemical powder (ABC), discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete with accessories complete all as specified and as directed. Note:1 No. at entry/exit of each floor.
S & F of 4.5 kg light-weight squeeze grip COշ type fire extinguisher, conforming to IS 15683: 2006, with COշ gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and as directed. Note : (i) Operating pressure: 10 to 15 bars (ii) Operating temperature : -30 °C to + 55°C (iii) Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters (iv) Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar
S & F Galvanized mild steel Fire bucket of capacity minimum 9 ltr (FILLED WITH DRY SAND) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red outside and Letter "FIRE" in black outside and handle with mounting bracket complete all as specified and as directed.
S & F Signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners of size 300 mm X 100 mm reading 'EXIT' in 12.5 mm block letters in Green and white background, properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level complete all as specified and as directed.
S & F Signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners of ) of size of 500 mm X 500 mm, indicating the "Floor Number" in bold type and at 75 mm high numerals in red and white background, posted and maintained within each stair enclosure on every floor, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level complete all as specified and as directed.
S & F Signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners of ) of 450 MM X 150 MM reading "FIRE EXTINGUISHER" in 12.5 mm block letters in White and Red background, properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level complete all as specified and as directed.
S & F Signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the "STAIRCASE" by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level complete all as specified and as directed.
Supply, installation, testing and commissioning of control consule complete all as specified and as directed.
S & F Loudspeaker cable of size 24/0.2 mm complete all as specified and as directed.
M & L for DI fittings such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs,Y junction, double branch,all socket or socket and spigot of size upto 150 mm bore complete all as specified and as directed.
Supply, laying and jointing of ductile iron pipes of 150mm bore with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-9), inner side cement lining and outer side black bitumen coating and any length, laid in trenches or fixed in floors or on walls including push on rubber (EPDM) ring with ISI marked complete all as specified and directed.
Supply, laying and jointing of ductile iron pipes of 100mm bore with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-9), inner side cement lining and outer side black bitumen coating and any length, laid in trenches or fixed in floors or on walls including push on rubber (EPDM) ring with ISI marked complete all as specified and directed.
S & F Cast Iron Air Valves of size 50 mm dia bore with single air Outlets, conforming to IS 14845 and fixing up in Cast Iron Water supply mains of size 150 mm dia complete all as specified and as directed.
S & F Foot Valve of size 100 mm (4”) dia conforming to IS 4038 complete all as specified and as directed.
S & F Butterfly valve (Slimline) of stem stainless steel of size 100 mm bore ISI mark PN 1.6 conforming to IS 13095 including nuts bolt and washers etc. complete all as specified and as directed.
S & F Butterfly valve (Slimline) of stem stainless steel of size 150 mm bore ISI mark PN 1.6 conforming to IS 13095 including nuts bolt and washers etc. complete all as specified and as directed.
S & F SCADA ready actuated electric butterfly valve for 100 NB size water supply systems, with open area installation line pressure maximum-7 Bars, Ends-wafer, Duty -on/off, 230 V AC/24 V DC, IP 67, enclosure, insulation class F, complete with travel switch and torque switch of size 100 NB (may reduce as per site). The specified butterfly valve shall be equipped with QR codes designed for geo-tagging purposes. These QR codes shall integrate with an asset management system, allowing for efficient tracking and management of the level sensor. By scanning the QR code, users should be able to access derailed information about the asset's location, usage history, maintenance schedules, and performance data . This system shall enhance the visibility and control over the assets, ensuring the are effectively monitored and maintained. Geo-tagging via QR codes should provide a streamlined solution for asset tracking, improving operational efficiency and reducing the risk of asset loss or mismanagement complete all as specified and as directed.
Supply, installation testing and commissioning open well horizontal type submersible pumpset, electric driven motor 3 Phase, insulation class B, voltage range AC 350 to 440 Volt, flater efficiency curve, 50Hz, CED coating, head 40 mtr, discharge 500 LPM, suction and delivery dia as per standard design of OEM suitable for delivery 500 LPM discharge at delivery pipe inclusive of suitable length (from submersible motor to starter) submersible cable PVC insulated and sheathed flat submersible cable with stranded copper conductor of size 3 core 10 Sqmm 1100 Volts grade including lugs and fixed in submersible pump & starter etc complete all as specified and as directed. Note: (1 W + 1 SB) at each UG Sump.
Supply, installation testing and commissioning open well horizontal type submersible pumpset, electric driven motor 3 Phase, insulation class B, voltage range AC 350 to 440 Volt, flater efficiency curve, 50Hz, CED coating, head 44 mtr, discharge 500 LPM, suction and delivery dia as per standard design of OEM suitable for delivery 500 LPM discharge at delivery pipe inclusive of suitable length (from submersible motor to starter) submersible cable PVC insulated and sheathed flat submersible cable with stranded copper conductor of size 3 core 10 Sqmm 1100 Volts grade including lugs and fixed in submersible pump & starter etc complete all as specified and as directed. Note: (1 W + 1 SB) at each UG Sump.
Supply, install, test and commission LT Feeder panel, TPN 415 Volts, 50 Hz, out door cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventilation including suitable size of cable alley aluminium bus bar suitable for carrying of current 60 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- (a) MCCB 32 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 25 KA - 1Nos (Incoming). (b) MCCB 16 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 16 KA - 2 Nos (Outgoing). (c) 3Ph digital multi function meter model A, class 1, 5A with relay Vega Series - 1 Nos (d) Indicating lamp 240 volts LED type - set of three. (e) Single phase preventor (VSP-3) - 01 Nos (f) Power capacitor of 3 Kvar capacity (3 Kvar - 01 Nos) - 01 set
Supply, installation, testing and commissioning of ultra sonic level sensor with following specifications : Rust proof, Maintenance free suitable for up to 6 meter water level depth of OHTs/ U/G sump, with dead band of less than 0.6 metre, IP67 protection, accuracy of 0.25% of F.S and 4-20mA current output, RS485 Modbus RTU communication protocol, No of wires 4 wire, Beam angle less than 7.5 degree. Capable for working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade, non-condensing at 25 degree Centigrade and humidity up to 95% with response time of less than 1 sec with 230VAC to 24VDC, 50Hz power supply. Non display type, in built temperature & voltage variation compensation, vertical type mounting on top of OHTs / Sump, suitable for measuring water / waste water in Sump / OHT, with all connections and fixing including clamp, nut-bolt etc complete all as specified and as directed. Note :The cost of wires/ cables any size/ type and length required at site as per OEM, s requirements . include all accessories required for proper functioning of the plant deemed to be included with this item.
Supply, Installation, Testing & Commissioning of Magnetic Float Operated Pivoted Level Switch (FPS) high, low or intermediate point level switching and ideal for over head tanks with inaccessible tops or bottoms complete with following Specifications :- Installation : Normally slide / Top for special applications Enclosure X Cable entry : Cast AI IP66 x PG 11 Gland MOC : SS316 Float Dia x Min SG : Ø50/Ø60 x SS (≥0.7 SG) Process Connection : Flanged or screwed Magnetic Switch Assembly : Micro switch in hermetically sealed casing (SPDT) 5A, 250VAC / 24 VDC Switching Differential : Fixed : 15 ± 5 mm Adjustable : between 40 & 300 mm depending upon float, trim length & cam positioning for SS MOC Repeatability / Accuracy : ± 1 mm / ± 2 mm Load / Insulation : Resistive / 150 M Ohm at 500 VDC (Min) Temperature Range : Standard Finish : Regular
Supply and Fixing of electromagnetic type flow meter for 100 NB size (may reduce as per site), with IP 66 protection 1.4 KV Isolation, accuracy of 0.5 MC, linearity of 0.5 % of MV, mounting in horizontal, 10 KGCm2 max pressure local indication through LCD display and RS 485 MODBUS RTU communication protocol, capable of working in ambient temperature of 0 deg C till 75 Deg C and Humidity upto 95% with Response time of less than 1 Sec working on 90-250 VA, 50 Hz with necessary flanges, nut, bolts, gasket and DI/CI specials II complete all a specified as directed. The specified electromagnetic type flow meter shall be equipped with QR codes designed for geo-tagging purposes. These QR codes shall integrate with an asset management system, allowing for efficient tracking and management of the electromagnetic type flow meter, By scanning the QR code, users should be able to access detailed information about the asset's location, usage history, maintenance schedules, and performance data. This system shall enhance the visibility and control over the assets, ensuring they are effectively monitored and maintained. Geo-tagging via QR code should provide a streamlined solution for asset tracking, improving operational efficiency and reducing the risk of asset loss or mismanagement. Specifications:- Operating temperature: 0-60 deg C Power supply: 220 V Ac, or 24 V DC Output : RS485 Modbus type Retransmission Output : 4 to 20 mA isolated Note: The flow Meter shall be provided with remote display unit that shall be installed in a MS Enclosure on the wall or Ground to prevent the electronic unit from being water logged.
S & F multistrand copper cable of size 1.5 Sqmm 2 core PVC insulated, PVC inner sheathed, flexible, armoured, overall PVC sheathed, steel braided, laid in trenches /floor or fixed on wall complete all as specified and as directed. Note: Rates include power cables to be laid as specified with GI/PVC pipe protection wherever deemed necessary.
Supply, Installation Testing & Commissioning of Indoor type PLC (Programmable Logic Controller) /RTU (Remote terminal Unit) based Automation, Protection Panel for Pump, Valve operation, energy monitoring, water flow regulation of main & pumping line, monitoring of water quality of treated water, priming arrangement of with feature of wireless Dual SIM Card based communication, suitable for control and monitoring of up to 06 Nos. Centrifugal Pumps,10 Nos. Energy Meters, 2 Nos. Motorized Butterfly Valves, 04 Nos Ultrasonic level sensor, 12 Nos. Solenoid Priming Valves (as per requirement), 12 Nos. Solenoid Air Release Valves (as per requirement), 8 Nos. pressure transmitters, 07 Nos. electromagnetic Flow Meters. The panel should be of minimum size 1200 X 950 X 300 mm front opening type, fabricated from 2.00 mm thick CRCA Sheet & mounting channel 40x40x5mm made out of Angle iron with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size. The Panel should have the following functionalities complete all as specified and directed:- (a) Water Level (Underground tanks), Flow monitoring to each OHTs (04 Nos) (b) Automatic Pump On/Off, Automatic Priming and Air Release (if required) (c) Automatic Operation of Motor Actuated Butterfly Valves (d) Automatic Toggling of Pumps (e) Auto Change Over in Case of Pump Failure (f) Pressure Gauges /Transmitters shall be installed in all piping systems to measure drop across pumping line & to play alarm for sudden droping in pressure. Also Pressure Gauges /Transmitters shall be installed both sides of circulation pumps for checking their operational performance (g) Single Phasing Prevention, phase sequence corrector (h) Online UPS with battery system of adequate capacity. (j) Manual Mode Operation (all connected sub systems at filtration plant) from the RTU/ PLC based Control Panel.
Supply, Installation, Testing & Commissioning of multifunction meters with RS485 for mounting on 1 no. pump house panel. The meter shall be of acc CI 1.0 and shall be able to record V, A, KW, KWH,PF,F. In addition, all meters shall also be able to record the (current and voltage) with all wiring cabling, cutting of cabinets, etc.
S & F Copper cable of size 1.5 Sqmm 10 Core armoured, PVC insulated with heavy duty PVC saddles 60 cm apart on wall/laying in ground complete all as specified and as directed.
M & L for construction of valves pit chamber having internal dimension 120 cm x 120 cm x 120 cm (internal height) using PCC (1:4:8) 40 mm graded crushed stone aggregate for foundation 15 cms thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 8mm thick MS top sheet cover with locking arrangement including 50 mm pad lock with double key arrangement, MS frame made out of 40 x 40 x 6 mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers finishing coal including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as specified and as directed.
Supply, Install, Test and Commissioning of LT ALUMINIUM BUS PANEL, TPN 415 Volts, 50 Hz, Indoor cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 2.00 mm thick with 1.60 mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 40x40x6 mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the LT Busbar Panel shall be provided with proper ventilation including suitable size of cable alley aluminium bus bar suitable for 26 Nos outgoing submain wiring/LT cables upto 25 Sqmm 2/3.5/4 core connected by using suitable sizes of thimbles/lugs/washers/nuts/bolts and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers, etc to the MC pedestal all as specified and directed comprising of the following: - (For Officer block of 24 Maj Accn) Incoming (a) MCCB 4 Pole, 415 Volt, 50 Hz with Microprocessor release 250 Amp with breaking capacity 16 KA – 01 No. (b) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breaker. Outgoing (a) Aluminium busbar TPN, 4 wire system, not less than 450 Amps rating and suitable for 26 Nos outgoing Submain wiring/LT cable upto 25 Sqmm 2/3.5/4 core complete.
Supply, Install, Test and Commissioning of LT ALUMINIUM BUS PANEL, TPN 415 Volts, 50 Hz, Indoor cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 2.00 mm thick with 1.60 mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 40x40x6 mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the LT Busbar Panel shall be provided with proper ventilation including suitable size of cable alley aluminium bus bar suitable for 26 Nos outgoing submain wiring/LT cables upto 25 Sqmm 2/3.5/4 core connected by using suitable sizes of thimbles/lugs/washers/nuts/bolts and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers, etc to the MC pedestal all as specified and directed comprising of the following: - (For JCO’s block of 240 JCO Accn “total 3 blocks”) Incoming (a) MCCB 4 Pole, 415 Volt, 50 Hz with Microprocessor release 250 Amp with breaking capacity 16 KA – 01 No. (b) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breaker. Outgoing (a) Aluminium busbar TPN, 4 wire system, not less than 450 Amps rating and suitable for 26 Nos outgoing Submain wiring/LT cable upto 25 Sqmm 2/3.5/4 core complete.
Supply, laying and testing of 200 mm internal dia of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI mark (with CML No.) including all fittings and jointing material for sewage line and laid in trenches as specified in IS 16098 -2013 part-II complete all as specified and directed.
Comprehensive Annual maintenance of DG set 50 KVA & 20 KVA for Third year (after completion of main project)
Comprehensive Annual maintenance of DG set 50 KVA & 20 KVA for Fourth year (after completion of main project)
Comprehensive Annual maintenance of DG set 50 KVA & 20 KVA for fifth year (after completion of main project)
Comprehensive Annual maintenance of 4 nos. of 8 passenger lift & 4 Nos of 13 Passenger Lift for third year (after completion of main project)
Comprehensive Annual maintenance of 4 nos. of 8 passenger lift & 4 Nos of 13 Passenger Lift for fourth year (after completion of main project)
Comprehensive Annual maintenance of 4 nos. of 8 passenger lift & 4 Nos of 13 Passenger Lift for fifth year (after completion of main project)
Provn of Services of Lift Technician (01 No during Day & 01 No during Night ) for Passenger Lifts at Narangi Mil Stn (Ph-I of Two PHs) complete all as specified and directed” Note : Payment Shall be made on montly / quarterly / Half yearly / Yearly basis in equal installments of amount due for that year on submission of RAR by the contractor.
Services of Lift Technician (01 No during Day & 01 No during Night) for Passenger Lifts for first year (during DLP)
Services of Lift Technician (01 No during Day & 01 No during Night) for Passenger Lifts for Second year (during DLP)
Services of Lift Technician (01 No during Day & 01 No during Night) for Passenger Lifts for Third year
Services of Lift Technician (01 No during Day & 01 No during Night) for Passenger Lifts for fourth year
Services of Lift Technician (01 No during Day & 01 No during Night) for Passenger Lifts for fifth year
Operation & Comprehensive maintenance of 35 KLD Package type STP for Third year (after completion of main project)
Operation & Comprehensive maintenance of 35 KLD Package type STP for fourth year (after completion of main project)
Operation & Comprehensive maintenance of 35 KLD Package type STP for fifth year (after completion of main project)
S K Construction (BID ID -3421115)
SHIVAM TRANSCON PRIVATE LIMITED (BID ID -3424203)
M/S ALLIED CONSTRUCTION (BID ID -3423700)
MUKUL BUILDERS LLP (BID ID -3424395)
HTE INFRA LLP (BID ID -3424275)
City Promoter and Buildwell Pvt. Ltd. (BID ID -3423792)
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED (BID ID -3424304)
Brahmaputra Commerce and Trade (BID ID -3424202)
Aalaya Engineering Project Private Limited (BID ID -3422899)
Som Projects Pvt Ltd (BID ID -3423860)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid