Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 CrAdmitted-Finance 233 PLATINUM PLAZA OPP IOCL PUMP NR JUDGES BUNGLOW CROSS ROAD BODAKDEV AHMEDABAD GUJARAT 380054 | AHMADABAD | GUJARAT | 380054 | ₹6.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.9 Cr+₹64.1 L (10.2%)Admitted-Finance | ₹6.9 Cr+₹64.1 L (10.2%) | L2 | Admitted-Finance |
| 3 | L3₹7.1 Cr+₹80.7 L (12.9%)Admitted-Finance BASEMENT NO 16 DHARMA TOWERS 88 150 NELSON MANICKAM ROAD CHOOLAIMEDU CHENNAI 600094 | CHENNAI | TAMIL NADU | 600094 | ₹7.1 Cr+₹80.7 L (12.9%) | L3 | Admitted-Finance |
| 4 | L4₹7.3 Cr+₹1.0 Cr (16.2%)Admitted-Finance | ₹7.3 Cr+₹1.0 Cr (16.2%) | L4 | Admitted-Finance |
| 5 | L5₹7.3 Cr+₹1.1 Cr (17.2%)Admitted-Finance | ₹7.3 Cr+₹1.1 Cr (17.2%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | EVERCREST PROJECTS PVT LTD. L1 | Sabari and Leon Electricals Pvt Ltd L3 | Arken Solutions Pvt. Ltd L5 | Konstelec Engineers Limited L2 | Kulaswaminee Engineerrs L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00Design, engineering, Manufacturing/procurement, fabrication, assembling, wiring, pre-dispatch inspection, testing, packing, forwarding, transportation, safe delivery to site, installation and commissioning of Standalone Indoor Type IP 44 Enclosure, 11 KV, 800 Amps, HT VCB panel with SC Breaking current of 26.3 kA(rms) for 3 seconds, as per Tender Specification and approved drawings. Power and Control Bus bars used in the Panel shall be Copper Bus Bar and bus bar sizing should be as per MELSON and BOTH Equation published in Copper Development association review Panel has to be configured in the existing SCADA. Panel shall be type tested and all the switch gear should be arc flash resistant. Bidder shall furnish valid type Test certificates already carried out on similar VCB from a reputed institute (other than bidder). All the Spares as per quantity mentioned in the Technical Specification should be supplied which includes earth truck( 1 No ), Vacuum interrupter bottle ( 12 Nos ), Trip Coil ( 8 Nos ), Closing Coil ( 8 Nos ), Auxilliary switch ( 8 nos ), Spring limit switch ( 4 Nos ), Spring Charging Motor ( 4 Nos ) , Breaker position limit switch ( 8 Nos ), VCB Draw out trolley ( 2 Nos ). Make :- ABB/L&T/Schneider Electric/Siemens/CG. Panel shall be procured from OEM or its authorized channel partner. | ||||||||
| 1.10 | Supply | 2 | Set | 20,53,956 ₹20,53,956 | 20,00,000 ₹20,00,000 Lowest | 44,40,458 ₹44,40,458 | 29,35,192 ₹29,35,192 | 26,36,676 ₹26,36,676 |
| 1.20 | Installation | 2 | Set | 76,700 ₹76,700 | 50,000 ₹50,000 | 23,600 ₹23,600 Lowest | 35,400 ₹35,400 | 30,680 ₹30,680 |
| 2.00Design, engineering, Manufacturing/procurement, pre-dispatch inspection, testing, packing, forwarding, transportation, safe delivery to site, installation and commissioning and submission of technical documents of 2.5 MVA, 11KV/0.433 V, Dyn11, ONAN, Oil Immersed Step down Transformer, Off circuit tap changer with a tapping range of +5% to -5% in steps of 2.5% on HT side and other accessories as listed in the Tender specifications. The transformer shall be suitable for bus duct termination on LV side and shall be provided with cable termination chamber on HV side. The transformer shall be as per IS 2026. Transformer should have fault capacity of 65 kA for 1 sec in the LV side. Conservator Tank should be Provided with air cell or diaphragm. OT/WTI communication should be provided with RS 485 port. Make:- CG/SIEMENS/KIRLOSKAR/VOLTAMP/ANDREWYULE/ALSTHOM. Transformer shall be procured from OEM or its authorized channel partner. | ||||||||
| 2.10 | Supply | 2 | Set | 1,03,02,136 ₹1,03,02,136 Lowest | 1,13,28,000 ₹1,13,28,000 | 1,14,79,512 ₹1,14,79,512 | 1,53,14,040 ₹1,53,14,040 | 1,31,07,204 ₹1,31,07,204 |
| 2.20 | Installation | 2 | Set | 1,77,000 ₹1,77,000 Lowest | 2,00,000 ₹2,00,000 | 1,77,000 ₹1,77,000 Lowest | 1,77,000 ₹1,77,000 Lowest | 15,64,680 ₹15,64,680 |
| 3.00Design, engineering, Manufacturing/procurement, pre-dispatch inspection, testing, packing, forwarding, transportation, safe delivery to site, installation and commissioning of 4000 Amps, 415 V, Sandwich Type Bus Duct containing 3 Phase and neutral copper bus bar for Extending power supply from Transformer LV side to the PCC as per Tender Specification and approved drawings ( Bus duct length should be as per site conditions and location of PCC Panel which will be approx 10 meters for each transformer). Bus Duct system shall be compact, low impedance type, totally enclosed and non-ventilated for protection against mechanical damage and dust accumulation. The busduct system shall be manufactured and type-tested to IEC60529 (Classification of Degree of Protection) to meet the requirement of indoor and outdoor installation. Ingress Protection should be IP55 or better. Phase sequence of Bus Bars in Bus duct shall match with the phase sequence of Transfomer and PCC Panel. Make :- L&T/ Schneider Electric/ Siemens/C&S. | ||||||||
| 3.10 | Supply | 2 | Set | 51,40,392 ₹51,40,392 | 44,00,000 ₹44,00,000 Lowest | 52,22,208 ₹52,22,208 | 46,66,954 ₹46,66,954 | 65,01,472 ₹65,01,472 |
| 3.20 | Installation | 2 | Set | 92,040 ₹92,040 Lowest | 1,50,000 ₹1,50,000 | 2,59,600 ₹2,59,600 | 1,18,000 ₹1,18,000 | 1,25,788 ₹1,25,788 |
| 4.00Supply, installation, testing and commissioning of 415V, 50Hz, 65KA /1 sec indoor switchgear with draw out type ACBs with overload, short circuit and earth fault release protections. The panel shall be totally type tested, Form IV B construction. The switchgear shall be fabricated as per latest IS and tender specifications 4000 A microprocessor based EDO 4 pole Incomer Air Circuit Breakers - 2 Nos 4000 A microprocessor based EDO 4 pole Buscoupler Air Circuit Breaker - 1 No 1250 A microprocessor based EDO 4 pole Outgoing Air Circuit Breakers - 4 Nos 800 A microprocessor based EDO 4 pole Outgoing Air Circuit Breakers - 8 Nos All feeders shall be provided with digital multi function meters to indicate voltage, current, power, energy, power factor; Analog ammeters with selector switch and On/Off/Trip Indication Lamps. Necessary CTs shall be provided on the three phases and neutral to achieve overload, short circuit and ground fault protections. Power and Control Bus bars used in the Panel shall be Copper Bus Bar and bus bar sizing should be as per MELSON and BOTH Equation published in Copper Development association review. Panel shall be type tested and all the switch gear should be arc flash resistant. Bidder shall furnish valid type Test certificates already carried out on similar Panel from a reputed institute (other than bidder). Make of LT PCC panel: OEMs-L&T / Schneider Electric / Siemens/Alstom. Make of ACB :- L&T/ SIEMENS/SCHNEIDER ELECTRIC. Panel and ACBs shall be procured from OEM or its authorized channel partner. | ||||||||
Tender Value
₹7.2 Cr
EMD Value
₹14.4 L
Closing Date
2 Sept 2024, 2:00 pmClosed
General Manager, ZC(P)
Office of General Manager, Zirconium Complex, Pazhayakayal, Tamilnadu-628152.
Supply, Erection, testing and commissioning of SPF substation equipment for augmentation of SPF at ZC (P)
2024_NFC_817422_1
NFC/ZC/2023/ ElectricalPackage-1/ SPF AGU /1
Open Tender
Electrical Works
Works
240 days
Zirconium COmplex, Pazhayakayal
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹14.4 L
Yes
22 Feb 2025
26 Jul 2024
6 Sept 2024
26 Jul 2024
2 Sept 2024
10 Aug 2024
Design, engineering, Manufacturing/procurement, fabrication, assembling, wiring, pre-dispatch inspection, testing, packing, forwarding, transportation, safe delivery to site, installation and commissioning of Standalone Indoor Type IP 44 Enclosure, 11 KV, 800 Amps, HT VCB panel with SC Breaking current of 26.3 kA(rms) for 3 seconds, as per Tender Specification and approved drawings. Power and Control Bus bars used in the Panel shall be Copper Bus Bar and bus bar sizing should be as per MELSON and BOTH Equation published in Copper Development association review Panel has to be configured in the existing SCADA. Panel shall be type tested and all the switch gear should be arc flash resistant. Bidder shall furnish valid type Test certificates already carried out on similar VCB from a reputed institute (other than bidder). All the Spares as per quantity mentioned in the Technical Specification should be supplied which includes earth truck( 1 No ), Vacuum interrupter bottle ( 12 Nos ), Trip Coil ( 8 Nos ), Closing Coil ( 8 Nos ), Auxilliary switch ( 8 nos ), Spring limit switch ( 4 Nos ), Spring Charging Motor ( 4 Nos ) , Breaker position limit switch ( 8 Nos ), VCB Draw out trolley ( 2 Nos ). Make :- ABB/L&T/Schneider Electric/Siemens/CG. Panel shall be procured from OEM or its authorized channel partner.
Supply
Installation
Design, engineering, Manufacturing/procurement, pre-dispatch inspection, testing, packing, forwarding, transportation, safe delivery to site, installation and commissioning and submission of technical documents of 2.5 MVA, 11KV/0.433 V, Dyn11, ONAN, Oil Immersed Step down Transformer, Off circuit tap changer with a tapping range of +5% to -5% in steps of 2.5% on HT side and other accessories as listed in the Tender specifications. The transformer shall be suitable for bus duct termination on LV side and shall be provided with cable termination chamber on HV side. The transformer shall be as per IS 2026. Transformer should have fault capacity of 65 kA for 1 sec in the LV side. Conservator Tank should be Provided with air cell or diaphragm. OT/WTI communication should be provided with RS 485 port. Make:- CG/SIEMENS/KIRLOSKAR/VOLTAMP/ANDREWYULE/ALSTHOM. Transformer shall be procured from OEM or its authorized channel partner.
Supply
Installation
Design, engineering, Manufacturing/procurement, pre-dispatch inspection, testing, packing, forwarding, transportation, safe delivery to site, installation and commissioning of 4000 Amps, 415 V, Sandwich Type Bus Duct containing 3 Phase and neutral copper bus bar for Extending power supply from Transformer LV side to the PCC as per Tender Specification and approved drawings ( Bus duct length should be as per site conditions and location of PCC Panel which will be approx 10 meters for each transformer). Bus Duct system shall be compact, low impedance type, totally enclosed and non-ventilated for protection against mechanical damage and dust accumulation. The busduct system shall be manufactured and type-tested to IEC60529 (Classification of Degree of Protection) to meet the requirement of indoor and outdoor installation. Ingress Protection should be IP55 or better. Phase sequence of Bus Bars in Bus duct shall match with the phase sequence of Transfomer and PCC Panel. Make :- L&T/ Schneider Electric/ Siemens/C&S.
Supply
Installation
Supply
Installation
Design, engineering, Manufacturing/procurement, fabrication, assembling, wiring, pre-dispatch inspection, testing, packing, forwarding, transportation, safe delivery to site, installation and commissioning of 105 AH Ni/Cd battery bank along with float cum boost charger to be able to supply 110V DC for closing and tripping of circuit breakers with spares as per Tender Specification and approved Drawings. Make :- EXIDE/HPL/AMCO/PRESTOLITE/AMARARAJA/UNION/LUMINOUS
Supply
Installation
Supply, laying of 11KV(E) grade XLPE insulated , extruded semi conducting Non-Metallic Screen, Copper tape Metallic Screen, PVC ST-2 extruded inner sheathed, Galvanised Steel Round wire armoured, Flame retardant low smoke (FRLS) C-2 PVC ST-2 outer sheathed cable as per IS 7098 (part-II) on wall/column/ground/Trench with all accessories Make:CCI/Universal/RPG/GEM/SPM/Finolex/KEI/Rallisons/Torrent 3C 150 Sq.mm Aluminium Cable ( Each 1000 Mts Drum )
Supply
Installation
Supply and providing indoor end terminations for following sizes of 11 KV grade XLPE insulated & PVC sheathed armoured aluminium conductor cables with RAYCHEM / 3M make heat shrinkable cable termination kits, copper crimping type lugs and other accessories as required for completion of termination in all respects. Make of Lugs: Dowells/Jainson/Braco/Hex/Comet/Connectwell 3C 150 Sq.mm Aluminium Cable
Supply
Installation
Supply and installation of heat shrinkable straight through cable joint kits of Raychem/3M make for 11KV grade 3C 150 Sq.mm Aluminium conductor XLPE insulated GI armoured Cables
Supply
Installation
Supply, laying of 11100 V Grade, Stranded ( Class 2) Compacted Sector Shaped H2/H4 Grade Aluminium Conductor as per IS : 8130-2013, Extruded XLPE Insulated ) as per IS 7098 Part-1 : 1988, Cores Laid up, PVC Type ST-2 Inner sheathed as per IS: 5831-1984, Galvanised Steel Flat Strip Armour IS : 3975-1999 and Extruded - FR-LSH PVC Type ST-2 Outer sheathed cables Conforming to IS 7098 : Part-1, on wall/column/ground/Trench with all accessories of following sizes. Make: CCI/Universal/RPG/GEM/SPM/Finolex/KEI/Rallisons/Torrent 3.5C 300 Sq.mm Aluminium Cable
Supply
Installation
Providing end terminations for following sized of 1.1 KV grade XLPE insulated and PVC sheathed armoured cables with required hard ware like heavy duty double compression cable glands, heavy duty long neck copper lugs etc complete. Make of glands/Lugs: Dowells/Jainson/Braco/Hex/Comet/Connectwell 3.5C 300 Sq.mm Aluminium Cable
Supply
Installation
Supply and fixing of following sized of earth flats for earthing by clamping on walls /Trays/Trench with all required accessories 50*6 mm GI Strip ( For LT Panels, Transformer & VCB body and for tray earthings )
Supply
Installation
Supply and fixing of following sized of earth flats for earthing by clamping on walls /Trays/Trench with all required accessories 100*10 mm GI strip ( For Main Grid forming )
Supply
Installation
Supply and fixing of following sized of earth flats for earthing by clamping on walls /Trays/Trench with all required accessories 50*10 mm CU strip ( For Transformer Neutral )
Supply
Installation
Providing pipe earthing stations with copper bonded (min 250 microns of Electrolytic Copper ) electrode (PIP type)of 3.0 Mts long and 80 mm dia including excavation and back filling with maintenance free Ground Enhancing Material (GEM), construction of masonry chamber with inside clearance of 450 x 450 mm with CI cover, earth station markers, testing, inter connecting earth tape between earthing stations and back fill material.etc. complete. Pit should be as per IS 3043 Make: Ashlok, Erico, JEF
Supply
Installation
Supply and Fixing of Copper Braid with clamp for joining all the cable armour strips and connecting to earthing terminals of HT and LT Panels
Supply
Installation
Supply and Installation of SUMIP/Reputed Make Ladder Type FRP cable Tray along with necessary hardware, accessories such as bends, tees, crosses, reducers, spilcer, clamps and fittings required for installation in existing HT and LT cable trench. 450mm x 100mm depth 4mm thickness Fiber Glass Reinforced Plastic(FRP) Tray
Supply
Installation
Supply and Installation of SUMIP/Reputed Make Ladder Type FRP cable Tray along with necessary hardware, accessories such as bends, tees, crosses, reducers, spilcer, clamps and fittings required for installation in existing HT and LT cable trench. 300mm x 100mm depth 4mm thickness Fiber Glass Reinforced Plastic(FRP) Tray
Supply
Installation
Excavation and backfilling in hard ground for laying the cables, back filling with sand for cushioning of cables,bricks for cable protection after laying the cables, consolidation, removal of excess earth, making good of surface to original finish etc complete excluding cost of bricks/Tiles/ Pipes
Supply
Installation
Supply and installation of RCC Tiles of size 500*250*50 mm made of 1:2:4 mix concrete and 8 mm steel rods 3 on each side with engraving "LT Cable"
Supply
Installation
Supply and Installation of 2.5 mm Thick 11KV grade panel front rubber mats, Category III, Class B as per IS 15652.
Supply
Installation
Supply and installation of cable route markers/Joint markers made out of cast iron of size 250*150*10mm embossed with "LT CABLE" along with 40*40*6mm MS angle of 600mm long and 200*200*300 mm concrete block
Supply
Installation
Supply and fixing of 100mm*25mm anodised aluminium cable tags engraved on black back ground with name of the load along with required hardware for fixing the labels on to the cables
Supply
Installation
Supply and installation of 300mm dia NP2 class hume pipes with required couplers for road crossing of cables
Supply
Installation
Cutting of roads (1.5m wide and 1m deep) Including removing the soling for laying hume pipes and back filling, Resoling making good the road to the original finish
Supply
Installation
Suply and installation of structural steel like channels, angles etc for fabriaction and erection of cable trays supports, light fitting supports etc and painting of the same with red oxide and 2 coats of grey enamel paint. Rate should also include the required bolts and nuts for fixing of supports Make of Structural steel: TATA, Vizag Steel, Jindal Ispat, SAIL
Supply
Installation
Relaying of dug roads with 1:2:4 PCC and providing reinforcement with 8mm rods
Supply
Installation
Konstelec Engineers Limited (BID ID -3079927)
Sabari and Leon Electricals Pvt Ltd (BID ID -3080255)
Kulaswaminee Engineerrs (BID ID -3074085)
Arken Solutions Pvt. Ltd (BID ID -3071745)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .