| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.3 LAccepted-AOC BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | 1 | Accepted-AOC Lowest Accepted Bidder | |
| 2 | 2₹21.6 L+₹56,673 (2.69%)Rejected-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | 2 | Rejected-AOC Lowest Accepted Bidder is M/S Bidawat Enterprises | |
| 3 | 3₹24.2 L+₹3.2 L (15.0%)Rejected-AOC WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | 3 | Rejected-AOC Lowest Accepted Bidder is M/S Bidawat Enterprises | |
| 4 | 4₹25.8 L+₹4.8 L (22.9%)Rejected-AOC | 4 | Rejected-AOC Lowest Accepted Bidder is M/S Bidawat Enterprises | |
| 5 | 5₹36.8 L+₹15.7 L (74.7%)Rejected-AOC | 5 | Rejected-AOC Lowest Accepted Bidder is M/S Bidawat Enterprises |
Tender Value
₹29.5 L
EMD Value
₹58,960
Closing Date
18 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Avik Saxena, CWE Bikaner
HQ CWE Bikaner, Mil Stn Bikaner, PIN-334001
Repair/replacement of LED flame proof light fitting, DBs, switches and connected work at Mil Stn Kanasar
2022_MES_570871_1
CA No CWE BKN-Token No. 66/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kanasar
As per Tender Documents
7 documents required · 7 mandatory
₹500
AGE (I) Kanasar
₹58,960
Yes
2 Mar 2023
23 Dec 2022
25 Jan 2023
23 Dec 2022
18 Jan 2023
6 Jan 2023
23 Dec 2022 - 31 Dec 2022
Amount
M&L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 400 Watt installed on wall / roof etc, Supply and fixing, testing Flame Proof LED High Bay light fitting sunflower type of 120 Watt, CMRI certified well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry ( for two entries for cable 3/4" x 2 Nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed. Make : Shyam/Sudhir or equivalent.
M&L for taking down of old Flame proof MH/HPMV High bay/Bulk head lights of capacity 250 Watt installed on wall / roof etc, Supply and fixing, testing Flame Proof LED High Bay light fitting sunflower type of 100 Watt, CMRI certified well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group , IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed. Make : Shyam/Sudhir or equivalent.
M&L for taking down of old Flame proof MH/HPMV High bay/Bulk head lights of capacity 200 Watt installed on wall / roof etc, Supply & fixing, testing Flame Proof LED High Bay light fitting sunflower type of 90 Watt, CMRI certified well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut/bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K independent potted IP 67 SMPS based Driver efficiency more than 85% along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed. Make : Shyam/Sudhir or equivalent.
M&L for taking down of old Flame proof MH/HPMV High bay/Bulk head light of capacity 150 Watt installed on wall / roof etc, Supply & fixing, testing Flame Proof LED Bulk head light fitting of 70 Watt/ 75 Watt, CMRI certified fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529 : 2001, gas group : IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 65 protection and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 Nos) with cable glands and PVC cover to be fixed / mount on horizontal wall with the help of nut / bolt / metal column structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A", Earthing 01 Nos inside 1 outside The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K independent potted IP 67 SMPS based Driver, efficiency more than 85% along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10ºC to 45ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified and directed. Make :- Shyam/Sudhir or equivalent
M&L for taking down of old Flame proof MH / HPMV High bay/Bulk head lights of capacity 70 Watt installed on wall / roof etc, Supply & fixing, testing Flame Proof LED Bulk head light fitting of 45 Watt/ 50 Watt, CMRI certified fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group : IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 65 protection certified by CIMFR Dhanbad and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 Nos) with cable glands and PVC cover to be fixed / mount on horizontal wall with the help of nut / bolt / metal column structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A", Earthing 01 Nos inside 1 outside The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K independent potted IP 67 SMPS based Driver, efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10ºC to 45ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified and directed. Make :- Shyam/Sudhir or equivalent
M&L for taking down of Flame proof 4 feet tube light fitting of capacity 36 W/ 40 W installed on wall / roof etc and opening the fitting cover / bottom by removing of nut / bolts / screws etc, making necessary modification / bypass arrangement for fitting of LED 20 Watt T8 retrofit lamp including replacement of old fluorescent lamp holder / bipin holder G13 push type by new G13 push holder on both side, Supply & fixing, testing new 4 feet LED 20 Watt lamp, T8 retrofit, two pin on both side, including driver length 4 feet operating voltage range 220-240 V, AC, frequency 50 Hz, CRI> 80%, inbuilt surge protection and SMPS based driver ,CCT 6500 K, frosted glass having as per IS-16102-1 (2012) with latest amendments and input voltage, P.F should be more than 0.9 with total harmonic distortion (THD) less than 10%, cool white colour . LED lamp should be suitable for ambient temperature from -10 ºC to 45 º and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report. After modification /replacement, re fixing the same Flame proof tube light fitting on original place and position etc complete all as specified & as directed.
M&L for taking down of Flame proof Bulk head light fitting of capacity 24 Watts installed on wall / roof etc and opening the fitting cover / bottom by removing of nut / bolts / screws etc, making necessary modification for fitting of LED bulb of capacity 12 Watts including replacement of B22 type bulb holder by new one batten bulb holder, Supply & fixing, testing old lamp by new LED lamp of capacity 12 Watts, base B22, including driver operating voltage range 140 V-270 V, AC, frequency 50 Hz, CRI> 80%, inbuilt surge protection and SMPS based driver, CCT 6500K, frosted glass as per IS-16102-1 (2012) with latest amendments and input voltage. P.F should be more than 0.9 with total harmonic distortions (THD) less than 10%, cool white colour. LED lamp should be suitable for ambient temperature from -10 ºC to 45 ºC and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report. After modification / replacement, re-fixing the same Flame proof Bulk head fitting on original place and position etc complete all as specified & as directed.
M&L for taking down of Flame proof 2 feet / 2.5 feet tube light fitting of capacity 36 Watts installed on wall / roof and opening the fitting cover / bottom by removing of nut / bolts/screws, making necessary modification for fitting of LED PL-L light of capacity 18 Watt including replacement of old fluorescent PL light type light holder by new 2G11 type holder, Supply & fixing, testing new LED PL-L lamp of capacity 18 Watts base 2G11, four pin, length 419 mm, width 44 mm, height 29 mm, operating voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, inbuilt surge protection and SMPS based driver , CCT 6500K , frosted glass as per IS-16102-1 (2012), light colour warm white 6500K, frosted glass as per IS-16102-1 (2012) with latest amendments and input voltage P.F should be more than 0.9 with total harmonic distoration (THD) less than 10%, cool white colour and LED lamps hould be suitable for ambient temperature from -10ºC to 45ºC and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report. After modification/ replacement, re-fixing the same Flame proof tube light fitting on original place and position etc complete all as specified & as directed.
Supply & fixing in replacement and testing Flame Proof LED light fitting 1x40 Watt including LED lamp/ tube complete, CMRI certified suitable for fixation on wall/roof with LED tube light fixtures driver, holders, connector etc, as per IS / IEC 60079-1: 2014 and 60529 : 2001, gas group :, IIA & IIIB, Zone 1 & 2, Tempclass T5/T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed/hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed. Make : Shyam/Sudhir or equivalent.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
S&F in replacement of switch Flame proof rotary type with termination box in LM6, 16 A, double pole with termination chamber 250 Volts, ISI marked, complete all as specified and as directed.
S&F in replacement of ELCB/RCCB capacity 63 Amp, 100mA three phase having charastics IEC 61008-1 Im-1000A, LNC-10000 A 4 Pole having single Knob for on off test switch, complete all as specified and directed. Make : L&T Model No. BGB 406310 / ABB / Havells or equivalent in makes.
Supply and laying, testing and commissioning in replacement LT copper cable 1.1 KV Grade 2.5 Sqmm 3 core steel wire armoured PVC insulated copper cable conforming to IS-7098, CM/L 566489 laid in duct /tray /wall /ceiling with the help of steel clamps including cable glands with rubber cover etc complete all as specified & as directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, rupturing capacity 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 16 Amps, SPN, 240 Volts, rupturing capacity 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
M&L for Earthing to Transformer / GOD switch / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m including dismantling & taking out old existing unserviceable earthing complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
S&F in replacement flame proof switch Knob made of Ceramic / plastic to be fixed on Flame proof MCB DB box for operating the MCB ON/OFF complete all as specified and directed.
Supply, installation, testing and commissioning factory LT feeder pillar box (KIOSK), outdoor type (cubical type), floor mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars suitable capacity in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-65 and made out of CRCA sheet of 3mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 40mmx40mmx5mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland inlcuding taking down old unserviceable LT panel complete and also comprising of the following :- (Description of serial item No. 18.00 contd....)
Supply, installation, testing and commissioning factory LT feeder pillar box (KIOSK), outdoor type (cubical type), floor mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars suitable capacity in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-65 and made out of CRCA sheet of 3mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys},, dange notice board in front and rear sidesand MS angle iron frame work (made out of 40mmx40mmx5mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland inlcuding taking down old unserviceable LT panel complete and also comprising of the following :- (Description of serial item No. 20.00 contd....)
Supply, installation, testing and commissioning factory LT feeder pillar box (KIOSK), outdoor type (cubical type), floor mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars suitable capacity in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-65 and made out of CRCA sheet of 3mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys},, dange notice board in front and rear sidesand MS angle iron frame work (made out of 40mmx40mmx5mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland inlcuding taking down old unserviceable LT panel complete and also comprising of the following :- (Description of serial item No. 22.00 contd....)
M/s Rohit Construction Co.
B.K. ROY & SONS
Gupta Suppliers
M/s Chopra Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .