DIRECTOR TMC
Office of Engineering services, Second Floor,Khanolkar Shodhika , ACTREC Kharghar Node, Navi Mumbai - 410210
TMC/ACTREC/ENGG/CB-430/ET-51/CT SCAN-HWCC/2022
2022_TMC_706228_1
Turnkey work for CT Scan Machine
Open Tender
Civil Works
Turn-key
180 days
ACTREC-Kharghar
As per tender terms and conditions
2 documents required · 2 mandatory
₹0
₹1.5 L
Yes
ACTREC, KHARGHAR
7 Oct 2022
11 Aug 2022
2 Sept 2022
11 Aug 2022
1 Sept 2022
11 Aug 2022
11 Aug 2022 - 12 Aug 2022
18 Aug 2022
Amount
CIVIL & INTERIOR WORKS
Dismantling brick masonry with plaster including lintel and Patti beams etc. of any thickness and at any level, location, height etc. including all type of scaffolding and staging, cleaning of debris, stacking at specified location and disposed out of ACTREC premises complete as directed and instructed.
Dismantling Wooden Partition of any thickness and at any level, location, height etc. including all type of scaffolding and staging, cleaning of debris, stacking at specified location and disposing out of ACTREC premises complete as directed and instructed.
Chipping the existing cement plastering upto ceiling level with scafolding, disposing the debries out of ACTREC premises complete as directed and instructed.
Removal of existing floor and skirting tile with bedding material to reach the bare slab, cleaning the space, shifting and stacking debris at specified location and disposing the debries out of ACTREC premises complete as directed and instructed.
Removal of existing false ceiling at any level, location, height etc. including all type of scaffolding and staging, cleaning the space, shifting and stacking debris at specified location and disposing the debries out of ACTREC premises complete as directed and instructed.
Dismantling of Doors and Windows and handing over the usable material to concerned authorities, and unservicale material shall be disposing the debries out of ACTREC premises complete as directed and instructed.
Provding and fixing Temoprary barricading in poisiton Dry wall system with GI framing and fising 12mm thick Gyspum board and sealing joints at flooring and ceiling with tempraru ply door shutter with frame before commencement of turnkey work and removing the same after completion of work etc comple as directed and instructed.
Removing existing fixtures and fittings and keeping is safe custody like signages, handrailin, corner guards, light fixtures and installing the same in its original conditions and replacing the same if damaged during the removing and refixing as per site conditons complete as directed and instructed.
CIVIL WORK
Providing and constructing Brick Masonry in cement mortor 1:4 (1 cement 4 Coarse sand), including RCC Patti beam of 100mm thick at every 1.2m c/c in the cement concrete mix M15 and including racking out joints, curing, independent legged scaffolding, all complete as per specification ect complete. For 4 1/2" Brick work (upto full ceiling height )
Providing and constructing Brick Masonry in cement mortor 1:4 (1 cement 4 Coarse sand), including RCC Patti beam of 100mm thick at every 1.2m c/c in the cement concrete mix M15 and including racking out joints, curing, independent legged scaffolding, all complete as per specification ect complete. For 9" Brick work
Providing and applying minimum 12mm thick Cement Plaster single coat with rough finish in cement mortor in ratio 1:4 to the internal surfaces of concrete, masonry work including kambs, sills, grooves, pattas, wattas rounding of corners ect all complete as per specifications and including racking out joints, hacking concrete, providing and fixing chicken mesh to junctions of concrete and brickwork, at any level, location, height ect. including all type of scaffolding and staging, cleaning of debris, stacking at specified location and disposed off. all complete as directed and instructed.
Providing and applying mini 2 mm POP Punning on walls and columns in proper line and level etc. with scafolding complete as directed and instructed.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface before commencemet of putty/paint work complete as directed and instructed.
Providing & Applying Luster paint two or more coats of primer & thereafter two coats of paint to the required colour scheme and as per manufacturers instructions / specifications to the walls, beams, columns, ceilings, partitions doors etc. including thoroughly scrapping the existing surface with sand papers, removing old paint, filling up crevices and levelling with waterproof putty / plaster of paris of necessary to obtain smooth surface etc. complete job including removal of stains, painting spots on floors,aluminium window frame & glass etc as to the entire satisfaction of engineer in charge
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete as directed Size of Tile 600x600 mm
Providing and fixing 18 mm thick and 230mm wide Granite door jamb any shade, colour from locally available and complete as per directions of Engineer-in-charge.
Supplying and injecting Anti Termite Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes, chemical and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration complete as directed and instructed.
Providing and laying in position cement concrete of specified grade M-15 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including the cost of centering , shuttering and removal of form work, Curing for All work as directed and instructed
Providing and laying in position cement concrete of specified grade M-25 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) including the cost of centering , shuttering and removal of form work, Curing for All work as directed by Engineer-in-charge.
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. Thermo - Mechanically Treated bars of grade Fe-500D or more complete as directed and instructed
Strucutral steel fabrication work in hollow / builtup section/MS plates / Chequred plate, cutting, weilidng, making good joints with coat of metal primer & 2 coat of enamel paint complte as directed and instructed.
Providing and injecting approved Epoxy injection grout in concrete/RCC work of approved make in proportion recommended by the manufacturer into area of concrete/masonry and at the gaps formed by the structural steel members with the existing RCC members by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions and instructions
Providing and fixing ISI marked 35MM Thick flush door shutters confirming to IS : 2202 (Part-I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters & 1mm thk. laminate on both faces of shutters with 6mm TW lipping all around with SS butt hinges and necessary screws etc. complete including seasoned Mirandi wood frames of approved section fixed with iron hold fasts and wooden moulding all around all hardware included i.e. Handles, Tower bolt, locks, Door closer stopper etc with or withiut vision panel with 5mm thick clear glass fising with tw beedaing around complete as directed and insttructed.
Providing and fixing Anodised Aluminum Hinged / Sliding Door or fixed / Sliding Window with 5.5mm floated glass and 12mm thick pre laminated board with standard build up extruded aluminum sections and anodised transpareent, minimum anodic coating grade and all hardware included i.e. Handles, Tower bolt, locks, Door closer / floor spring, stopper etc complete as per directions and instructions
Providing and fixing flush door shutters commercial type, core of block board construction with frame of 1st class hard wood & comm. Ply & 1mm thk. laminate on both faces of shutters with 6mm TW lipping all around with SS butt hinges and necessary screws etc. complete including seasoned Mirandi wood frames of approved section fixed with iron hold fasts and wooden moulding all around all hardware included i.e. Handles, Tower bolt, locks, Door closer stopper etc 1500 x 2400 (with 2mm lead sheet lining shutter & frame complete)
Providing and fixing flush door shutters commercial type, core of block board construction with frame of 1st class hard wood & comm. Ply & 1mm thk. laminate on both faces of shutters with 6mm TW lipping all around with SS butt hinges and necessary screws etc. complete including seasoned Mirandi wood frames of approved section fixed with iron hold fasts and wooden moulding all around all hardware included i.e. Handles, Tower bolt, locks, Door closer stopper etc 900 x 2400 (with 2mm lead sheet lining shutter & frame complete)
Providing and fixing flush door shutters commercial type, core of block board construction with frame of 1st class hard wood & comm. Ply & 1mm thk. laminate on both faces of shutters with 6mm TW lipping all around with SS butt hinges and necessary screws etc. complete including seasoned Mirandi wood frames of approved section fixed with iron hold fasts and wooden moulding all around all hardware included i.e. Handles, Tower bolt, locks, Door closer stopper etc 1200 x 900mm (lead lined Window frame only)
P/f Trap door in ACP with 4mm thick sheet on with 25x25 mm aluminium section for framing and supporting with necessarry MS toe rods etc complete as directed and instructed.
Providing the Fire rated steel doors of approved make with following specification .Steel door shutter of 45mm thick fully flush, double skin door shell with seamless welding joint all around manufactured from 0.8mm thick G.I. sheet with reinforcement of steel C channel all around the edges of shutter for additional protection. Internal reinforcements all construction of the door is specially designed honeycomb infill with reinforcement all around. construction of the door is specially designed honeycomb infill with reinforcement all around. Door frame is produced from 1.2mm G.I. sheet formed to single rebate profile of size 100mm x 57mm (+/- 0.3mm) with a maximum bending radius of 1.2mm. The door frame will be attached to the brick or block walls using Anchors not welded to the frame (First fix). The door frame and shutter should be powder coated. Inclusive of Door Fixtures D handle, Door closer, Lock, etc. The agney shall submitt Ceritificate and approved vendor from Fire Dept Govy of Maharashtra.
FURNITURE
Providing & fixing counter top 750mm wide and 750mm high Counter top should be 18 mm thick plywood with 3mm thick veneer sheet-with veneer polish /6 mm waterproof MDF sheet- with PU paint of approved colour with rounded corners and bull nose / half round chamfer at the front edge; over 18mm thick ply and all the inside surfaces of ply board to be covered with matching shade laminate and edge covered with teakwood edge banding/PU Paint. All wooden banding and veneer surfaces to be finished with PU paint/ Veneer Polish. The under-structure shall be made of Solid wood with matching 1mm laminate. Key Board Tray on heavy duty telescopic channels; Foot rest and CPU stand etc. accessories included. All joinery to be done with SS screws.
Providing & fixing counter top 600mm wide and 750mm high Counter top including full nosing and sides should be 18 mm thick plywood with 3mm thick veneer sheet-with veneer polish /6 mm waterproof MDF sheet- with PU paint of approved colour with rounded corners and bull nose / half round chamfer at the front edge; over 18mm thick ply and all the inside surfaces of ply board to be covered with matching shade laminate and edge covered with teakwood edge banding/PU Paint. All wooden banding and veneer surfaces to be finished with PU paint/ Veneer Polish. The under-structure shall be made of Solid wood with matching 1mm laminate. Key Board Tray on heavy duty telescopic channels; Foot rest and CPU stand etc. accessories included. All joinery to be done with SS screws.
Providing and fixing in position Movable Pedestal units shall be made out of 18 mm thick plywood covered with 1.0 mm thick laminate on outside and 0.8mm thick matching laminate on inside including drawers of table. The drawers should be mounted on the heavy duty telescopic channels. Out of total 3 drawers one unit should be used for filing and two drawers shall be utility box drawers. The size of pedestal unit shall be 450 mm W x 450 mm D x 680 mm H. The fascia of these drawers shall be made out of 18 mm thick Ply covered both side with 1mm laminate with edge bending; with locking arrangement of 6 levers inbuilt branded lock system with key in duplicate. The drawer unit is provided with central locking system, where in the three drawers are locked with one key.
Providing and fixing in position 600mm deep wooden Cupboards / wardrobes of required size made of 19mm thick BWP board of approved make on top, bottom, sides, partitions, shelves, shutters. 12 mm thick BWP ply in drawer unit and 6mm thick BWP ply of approved make at back of cupboard / wardrobe as per drawing. 1.0 mm thick laminate of approved make and shade on shutters & exposed sides of cabinets wherever required and 0.8 mm thick laminate shall be fixed on all unexposed inner faces of cabinet. Back side of cabinet shall be finished 1mm thick laminate finish, wooden lipping, suitable locking arrangement, all types of screws , fasteners, hinges / piano hinges, wooden screws, adhesives, polishing / painting of lipping, telescopic drawer channels, magnetic catchers, tower bolts, door handles/ knobs and all other types of necessary fittings etc. complete as per design, drawing and site condition as directed by the Engineer-In-Charge
Providing and fixing of low height storage cabinate having 400mm. depth of is to finished with1.0mm th. laminates as per design of approved shadea and the inner surface is finished with laminate of 1mm thick with as per design The work should be completed according to drawing and design including all labour and materials. made out of 19mm th. commercial ply the exposed surface shall be finished of laminate as per design and draiwng complete as directed and instructed.
Designing and SITC of custom virtual skylights – photographic illusions of real sky views with low-profile LED lighting system to provide daylight quality light and translucent, high-resolution, photographic reproductions on durable, lightweight acrylic/fabric panels that convey the color, scale, and perspective of actual skies. Samples graphis shall be got approved before procuement complete as directed and instructed.
WOODEN PANELLING : Providing and fixing of wooden paneling and column cladding where ever mentioned in the layout and on the columns with 12 mm thick ply and 1 mm laminate finish (glass fixing) (water proof ply) with base frame of min 25mm x 25mm section.
WALL PAPER: Providing and fixing of internal graphics premium quality wallpaper of approved design and sizes
Supply and fixing of SS Name boards sizes (16"X4") with strut and all accessories
5mm thick mirror of with ply bancking & framing
CEILING/GRID CEILING
Providing and fixing Metal false ceiling at all height including providing and fixing of frame workmade of special sections, power pressed from M.S. sheets and galvanized with zinc coating of120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, in luding fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long drywall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of drywall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistat board
Providing & fixing 12mmm thick Hylux fals ceiling in drops and stips with GI framing fising in prositon. Finishieng including wastage etc including two coat of painting complete as directed and instructed.
FLOORING
Providing and fixing of approved make and shade Anti Static Vinyl flooring of 2mm thick 100% recycled PVC flexible, homogeneous conductive calendared compacted floor covering, minimum weight 3120 g/m2 in minimum sheet of size 2mtrs. x 20 mtrs. approved pattern & colour combination with PUR Protect or equivalent surface treatment having wear minimum resistance of = 4.0mm3 as per EN 660.2 and wear group Group P as per EN-649 and should have a minimum residual indentation of <0.03mm confirming to EN-433. The laid flooring should have non- directional design, colour dyed as a raw mixture to ensure even colour throughout the thickness and its surface should be densely compacted for improving wear and ease of maintenance with Anti-bacterial and Fungicidal properties. The laid flooring shall confirms the fire rating B1 class as per EN 13501-1. The floor finish should terminate at the room perimeter passing over a concealed cove former and continuing up the wall for 100mm. The joints in the flooring should be sealed by using a PVC welding bar of matching colour to be supplied by the manufacturer, using a hot air gun for fusion of welding bar with flooring and provide necessary cowin at required places.
Supply , installation , commissioning of 50 mm radius pvc coving between wall panel to floor and wall to wall joints/ Aluminium powder coated D sections for outer corners
Providing and fixing Vitrified floor 600x600x8.5 mm th. glossy/matt finished vitrified tile flooring of approved shade laid on a minimum bedof 20mm th. cement mortar 1:3 finished with flush in all respects pointing matching with tile colour & pigment complete. As directed and instructed.
WALL TILES
Providing and fixing Wall Dado Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete as directed by Engineer-in-charge. Size of Tile 600x600 mm / 600x300/600x450mm
PLUMBING WORK WORK
P/f CPVC Pipe line including chaing wall, fising in positon with clamps, with specials includinf gate valve making good connection to exisitng pipe line, pressure testing complete as directed and instructed.
15mm dia pipe
20mm dia pipe
50mm dia for drain pipe
Providing & supplying SS 304 gade custome made Scrub sink with wall mouting arragnement with water supply and drain connection as per site conditons with elbow action (heavy duty 1st quaity) tap with splash guard and perforated tray complete as directed and instructed. Approx overall size is 1.20 m x 0.60m wide deep enough to wash hand - elbow.
MEDICAL GAS PIPELINE SYSTEM
Supply, Installation, Testing, Commissioing of Medical Gas Isolation valves, bare on line, NFPA 99 compliant, High tensile bronze/ brass 4 bolt bronze body double seal union ball type with TFE/ Viton seal 400 psig isolation valves with K type pipe stubs-Medical Grade Copper pipe for fixing in the Floor Local Zone Valve box,Area Valve Boxes, Bare for wards.
15mm OD Tube
Supply Installation Testing & Commissioning of Gas Outlets Surface Mounted with Matching Adapter. The Outlet shall be NFPA99 standard
Oxygen
SUCTION AND OXYGEN THERAPY PRODUCT
Supply, Installation, Testing, Commissioing of Oxygen flow meters with humidifier bottle BPC complying with ISO 15002:2008 range of 0-15 LPM, 3-5 psig humidifier setting and all other hardware, tube etc as per instruction and as directed by OIC-ES
Supply, Installation, Testing, Commissioing of ward Vacuum Unit complying with ISO100793 :2000 consisting of 0-760 mbar vaccum regulator, vaccum filter & 1000 ml vacuum collection jar made from polycarbonate/ polysulphone material with all other hardware, tubes etc as per instruction and as directed by OIC-ES.
Supply, Installation, Testing, Commissioing of as per NFPA 99 Level 6020 Medical Grade Gas distribution piping manufactured from phophorpus deoxidized non arsenical copper to BS EN 1412:1996 grade CW024A manufactured to metric outside diameters having mechanical properties in accordance with BS EN 13348:2008-R250 half hard for sizes up to 54 mm or BSEN 133348:2008-R290 fro larger sizes in ready made built up trenches as per applicable standard, open execution on internal / external walls, in vertical shafts, above false ceilings as also inside removable trunking, in walls by chasing cutting compelete with factory made fittings such as tee/ elbow/ crossover/ wall sleeves etc., complete with vertical & horizontal supports and termination at both ends, colour coded painting etc.
Copper Pipe - 12 OD X 0.7 mm thick
Copper Pipe - 15 OD X 0.9 mm thick
ELECTRICAL WORKS
CIRCUIT CUM POINT WIRING (SUPPLY, INSTALLATION, TESTING AND COMMISSIONING
Wiring for the following light points with 1.5 sq.mm PVC insulated FRLS copper conductor 1100 volts grade stranded flexible wires of approved make in concealed or surface mounted 25 mm dia 2 mm thick PVC FRLS conduit including fixing of 6 amps single pole rocker operated flush mounted switch of approved quality colour make & design in 1.6 mm thick GI box and earthing of fixtures & the outlet box with 1.5 sq.mm PVC insulated FRLS copper conductor stranded flexible wire.
Primary point with switch ( from switch board to first point - cost of switch & board included)
Secondary point without switch ( from light point to light point - cost of switch & board NOT included)
Wiring for 250 volts single phase and neutral 6 Amps switched socket outlet with 2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in concealed or surface mounted 25 mm dia 2.0mm thick PVC FRLS conduit including providing and fixing of 6 Amps 3 pin switch socket outlet of aprpoved make and design in 1.6 mm thick GI box with grid plate and earthing of third pin of the socket with 2.5 Sq. mm PVC insulated copper conductor stranded flexible FRLS wire , complete in all respect.
Primary point for 6 amps switched socket outlet
Same as item no. 3 above but secondary point looped with primary point
Wiring for 250 volts single phase and neutral a set of 16 Amps 5pin socket outlet and 1 No 16 Amps switch with 4 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in concealed or surface mounted 25 mm dia 2.0mm thick PVC FRLS conduit including providing and fixing of 16 Amps 5pin socket outlet and 1 No 16 Amps switch of approved make and design in 1.6 mm thick GI box with grid plates and earthing the third pin of each socket outlet with 4 Sq mm PVC insulated copper conductor stranded flexible FRLS wire , complete in all respect.
Primary point for 16 amps switched socket outlet
Same as item no. 4 above but secondary point looped with primary point
Providing and fixing of emergency control switch with push button
Providing and fixing of control switch with on/off pattern
Providing and fixing of following PVC insulated copper conductor 1100 volt grade stranded flexible FRLS wire in conduit including providing and fixing of conduits concealed or surface mounted making connections complete.
3 Nos. 1.5 sq.m PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in 25 mm dia PVC conduit.
3 Nos. 2.5 sq.m PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in 25 mm dia PVC conduit.
3 Nos. 4 sq.mm PVC insulated copper conductor 1100 volts grade stranded FRLS wires in 25 mm dia PVC conduit.
3 Nos.6 sq.mm PVC insulated copper conductor 1100 volts grade stranded FRLS wires in 25 mm dia PVC conduit.
CABLES, MAINS AND SUB MAINS
Supply, Laying, Testing and Commissioning of following 1100V XLPE A2XFY (XLPE insulated Armoured Aluminium) / YFY (Armoured Copper) / YY (Unarmored/Flexible Copper) cables laid over MS supports / Cable racks / in excavated Trench / fixing of walls including clamping the cable to the support in all approved manner as all complete required (Note : Inclusive of supply of Anchor Fasteners, straight through joints and necessary 1.5mm thick GI Flat, clamps shall be included in the laying cost).
3.5C 240 Sq.mm A2XFY-XLPE for PANEL etc
4C 10 Sq.mm flexible cu cable
1C 95 sq.mm. flexible cu cable
1C 70 sq.mm. flexible cu cable
4C 16 sq.mm. flexible cu cable
Supply, Erection, Termination of PVC insulated armoured / unarmoured cables up to 1100V grade and connection of leads including the supply of Aluminum/COPPER cable lugs but including cutting stripping of cable insulation, providing double compression type glands, terminals, and armour earthing ,crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number ferrules, etc.with Gland hood to be provided at the cable end entering to the Main panel and including all labour and materials complete and as per specifications of this tender and directions of Engineer-in-charge. End Termination of Cable using jointing kits & accessories as recommended by cable/ kit manufacturer.
240 sq. mm. (Ring Type)- Cu
120 sq. mm. (Ring Type)- Cu
70 sq. mm (Ring Type) - Cu
50 sq. mm (Ring Type) - Cu
4C 16 Sq.mm (Pin type)- Cu
4C 10 Sq.mm (Pin type)- Cu
Providing and fixing of the following size medium class GI pipe sleeves.
40 mm. dia.
50 mm. dia.
CABLE TRAYS, RACEWAY & JUNCTION BOXES:
Supply and fixing of Hot deep - galvanized perforated type GI cable trays of the following sizes as per specification.
300 mm x 40 x 40 x 2 mm thick
150 mm x 25 x 25 x 2 mm thick
MAIN LT PANEL FOR EQUIPEMENT, UPS & HVAC
MAIN LT PANEL FOR EQUIPMENT & HVAC SYSTEM: (location at UPS ROOM)
Supply, Installation, Testing & Commissioning, cubicle type compartmentalized board made out of 2mm thick CRCA sheet, totally enclosed, IP 42, floor mounted with channel base frame, dust and vermin proof, indoor, suitable for operation on 415 V, 50Hz AC supply with extensible busbars on both sides including control wiring with 2.5 sq mm size wires/cable, interconnection, duly powder coated painting, earthing, labelling etc. Including supply & installation of following switchgears, metering instruments and accessories as per specifications. Incoming AS PER SLD :Metering & Indication AS PER SLD: Outgoing AS PER SLD
FINAL DISTRIBUTION BOARDS Supply, installation, testing and commissioning of the following seven segment FDB's fabricated out of 1.6 mm thick, CRCA sheet steel in dust and vermin proof, double door construction, powder coated with approved shade and segregate phases. Approved covers with padlocking arrangement, recessed in wall or surface mounted final distribution boards of the following description:
12 Way TPN DB, 12 Nos. 10/16/20 Amps SP, 2 nos. 32Amp DP MCB, as outgoing with 3 Nos. 40 amps DP RCCB’s of 30 mA leakage current and 1 No. 63 Amps 4 pole MCB isolator as incomer with separate neutral link. For each phase.(All MCB shall be c curve)
Supply, installation, testing and commissioning of VTPN DB with 63 Amps 4 pole MCCB as incomer (25 KA) breaking capacity in 1.6 mm thick MS enclosure of approved make design and painted with approved paint shade, and 4 no's outgoing of 40 Amp 4P MCB
Supply, installation, testing and commissioning of 160 Amps 4 pole MCCB with operating handle (25 KA) breaking capacity in 1.6 mm thick MS enclosure of approved make design and painted with approved paint shade.
Supply and fixing in position 1000 mm wide Insulation matting of 1100 volts grade as per electricity rules (exact length mats to be worked out as per site requirement).
EARTHING INSTALLATION (FOR DISTRIBUTION SYSTEMS, UPS SYSTEM, EPABX & MEDICAL EQUIPMENT ETC.)
8 SWG GI wire
Supply, Installation, Testing and Commissioning of Advance Maintenance Free earthing environment friendly Chemical Earthing system consisting of 3 mtr length, 80 mm dia pipe earth electrode made of steel circular rods, molecularly bonded copper on outer surface (minimum copper bonding thickness 250 microns) with terminals to connect conductor with 1bag (25Kgs) of environment friendly back fill compound with DMC Pit Cover. Earthing value should suitable for X-ray system and Grid earthing value should be achieved less than 1.5 Ohm, if it is not achieved then corrective action will be taken by contractor. All test certificate of Earthing rod and chemical should be submitted. Earthing marking is in the scope of Vendor. No earth pit shall be fixed within 2.5M of a wall of foundation. The location of the earth electrode will be such where the soil has reasonable chance of remaining moist. Effort shall be made to locate them in grass lawns or near flowerbeds or water taps. The distance between two earthing pits/stations shall be at least 3.0 meters as per specification and drawing.
Providing, laying, testing and commissioning of following 1100 volts grade PVC insulated sheathed copper conductor unarmoured cable including copper thimbles, fixing hardware as required. Single core 50 sq.mm Green colour cable
Providing and fixing of Earth Bus Box - 300 mm long, 50mm wide x 6mm Copper Earth Bus in an Earth Box complete in all respects with Nut Bolts, insulators etc.
Supply, laying, testing and commissioning of GI pipe under road / paved area crossing etc. including excavation back filling ramming and making good. 50 mm dia pipe.
SUPPLY & INSTALLATION OF LIGHTING FIXUTRES
Supply, storing, handling, installation & commissioning of following lighting fixtures with all fixing accessories etc. as required.The System efficiacy of fixure shall be not less than 100 Lumen/watt and Glare (UGR) not more than 19 for LED Panels & 22 for other light fixtures.
Supply, storing, handling, installation & commissioning of Recessed mounted 15W LED down lighter with die cast aluminium housing with inbuilt controller and robust consction complete as required.Engineer-in-charge make, Cat No: DN194B LED15S-6500 PSU WH S1 or equivalient
Supply, storing, handling, installation & commissioning of Recessed mounted 30W 2'X2' LED PANEL made up of CRCA housing with bottom frame having system lumen o/p 3000lm & 30W having glare rating strictly <19 suitable for indoor applications maintaining system life of 50K burning hrs & THD<10, PF>0.95 simillar to Engineer-in-charge RC380B LED30S 6500 L60W60 PSU OC.
Supply, storing, handling, installation & commissioning of Self contained single sided Radiation Warning Light/ exit sign for wall / ceiling / pendant cantilever mounting with LED tube for non maintained battery backup emergency lighting for 3 hours duration, Prolite make or approved equal in quality and design.
TELEPHONE/DATA SYSTEM
CONDUITING WIRING AND CABLING FOR TELEPHONE/DATA SYSTEM
Supply, installation, testing and commissioning of flush mounted outlets wired to T 568 A or B with British style faceplace. The plastic shall be high impact, flame-retardant, UL rate thermoplastic. Dust cover/ blank shall be provided to protect unused faceplate openings. Termination caps and plastic over should be provided to protect jack wiring. Quoted price shall be inclusive of 1.6 mm thick GI Boxes.
Single outlet faceplate with RJ-45 jack for Cat-6A Cable
Duplex outlet faceplate with RJ-45 jack for Cat-6A Cable
Supply, fixing, cable termination, testing and commissioning of passive components etc. as required.
3 meter patch cord
Wiring for Following telephone junction with 0.5 mm PVC insulated tinned copper conductor cables of in existing conduits / trays / raceways.
Supply and fixing in position RJ - 11 Telephone points i/c wall recessed
GI box for LAN of approved make.
Supply, installation, testing and commissioning of following Category 6 IDC patch panel prepackaged with wiring block with legs insert labels, label holders, jumper troughs, metal back panel, duct assembly, screws, washers and an instruction sheet for termination of incoming pairs. Quoted price shall include suitable lockable enclosure etc. as required.
12 port jack panel for Cat-6A Cable
Supplying and laying of Cat 6A cable and Providing and fixing in position the following 2.0mm thick PVC FRLS Conduit concealed or exposed as called for including all accessories i.e. bends, junction boxes with cover plates of approved make and design. 25mm dia conduit
Supply, Installation, Testing and Commissioning of door access control system with fingerprint and RFID entry control system as per manufacturar's specification and accessories. all complete
AIR CONDITIONING
AC EQUIPMENT
SPLIT UNITS (non Inverter Type)
Supply, Installation, testing and commissioning of Air-cooled Hi-wall air conditioners each comprising an outdoor unit consisting of compressor, air cooled condenser, condenser fan along with Cooling thermostats etc. with outer casing and indoor fan coil unit consisting of centrifugal fans, fan motor, DX cooling coil, outer casing, filter, control and power panel with remote etc. entire cabling and wiring from indoor to outdoor, insulation and with full charge of refrigerant gas and oil, supports, canvas connection etc. complete as per drawings. The indoor and outdoor units shall be with structural steel supports, angles, rods etc, MCB, etc from main panel to the unit. The refrigerant used shall CFC Free R-410 A. all split units shall be BEE 3 stare rated. Note:- outdoor stand/fabricated stand should be considered no additional cost given for the same.
1.0TR Hi wall type
1.5TR Hi-Wall Type
2.0TR Hi-Wall Type
SITC of Refrigerant Flow System as per specification.
All refrigerant piping shall be of copper, complete with supports between indoor & outdoor units duly insulated with 13mm Nitrile rubber insulation with GC cloth.RMT indicated is for set of piping between indoor and outdoor machine, individual piping will not be measured. All Exposed Cable should be laid in ladder/perforated type tray
1/4,1/2 or equivalent to the unit
1/4,5/8 or equivalent to the unit
SITC Control cables between indoor and outdoor unit All Exposed Cable should be laid in ladder/perforated type tray.
SITC PVC drain pipe having pressure holding of 6kg/cm2 Drain piping complete with all accessories with 6mm Nitrile Rubber Insulation.
DIA. 25MM
Design, Supply, fabrication and installation of G.S.S ducting:(Factory fabricated duct shoul be provided).
Design, Supply, fabrication and installation of G.S.S. ducting with volume control dampers on every branch if there is, powder coated supply/return air diffusers with required hardware’s, supports, wooden frame and painting on ducts, MS parts etc with acoustic insulation 19 mm(supply)/13 mm(return) nitrile rubber insulation as per the SMACNA Standard, approved drawings and instructions of Engineer-in-charge with the following gauges. Note:- All exposed duct insulation should be with AL cladding.
24 gauge G.S.S. Rectangular duct with necessary insulation and metallic foil.
Supply & fixing of Volume control dampers at collars supply / exhaust for above units made out of 18 guage GI. frame & 20 guage GI blades at the supply & return air ducts.
SITC of Extruded aluminium powder coated diffuser with volume control damper with all necessary supports as per directed and as instructed by OIC-ES
SITC of Extruded aluminium powder coated diffuser/ Grill without volume control damper with all necessary supports as per directed and as instructed by OIC-ES
Dismantling of existing Duct,damper,diffuser, grill, fire hydrant pipe and reinstallation of fire hydrant pipe etc as per instructed and as directed by OIC-ES
FIRE DETECTION AND ALARM SYSTEM
Supply fixing and drawing of 2C x 1.5 sq mm FRLS grade PVC insulated stranded copper conductor wires drawn in 2mm thick 20 mm dia PVC FRLS conduit with all accessories and GI boxes in recess/surface including cutting wall and making good the same as required.
Supply, testing, installing and commissioning of the following fire detection and alarm accessories complete with connection etc. as required including the system's interlink connections with the Fire alarm panel at the reception :
Adressable Photoelecric Smoke detector
Supply fixing and drawing of 2C x 1.5 sq mm FRLS grade PVC insulated stranded copper conductor wires drawn in 2mm thick 20 mm dia PVC FRLS conduit with all accessories and GI boxes on surface as required, for connecting with existing Fire Panel
Supplying and fixing of 5KG capacity of ABC Type fire extinguisher
Vaishnavdevi Furnishers
ADARSH INFRAINTERIO PVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .