Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹32.7 L+₹3.0 L (10.1%)Rejected-Finance H NO 13149 STREET NO 3 SHIV COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹35.2 L+₹5.5 L (18.6%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹35.5 L+₹5.9 L (19.8%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹37.3 L+₹7.7 L (25.9%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹38.1 L
EMD Value
₹76,200
Closing Date
9 Aug 2023, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin 152116
Special repair to P-320 of 222 Fd Wksp Coy EME and other sanctioned work at mil stn Abohar.
2023_MES_608686_1
GE ABH-36/23-24
Open Tender
Civil Works
Item Rate
180 days
ABOHAR MIL STN
AS PER NIT
7 documents required · 7 mandatory
₹500
GE ABOHAR
₹76,200
Yes
24 Oct 2023
12 Jul 2023
11 Aug 2023
12 Jul 2023
9 Aug 2023
26 Jul 2023
Amount
Demolition of brick work built in cement mortar complete all as specified and directed by Engineer - in - Charge.
M&L for Brick work using old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
All as above item 02 but except bricks all as specified .
M & L for brick work in half brick thick wall using bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster/dado on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified .
M & L 5mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
M & L rendering 15mm thick on fair faces or other than fair faces of brick work in CM 1:6 finished even & smooth without using extra cement all as specified .
M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces, in cement mortar (1:4), in two layers of 10+5mm thick with using water proofing compound as per manufacturer's instructions, surfaces finished even and smooth without using extra cementcomplete all as specified.
Shotcreting 25mm thick in RCC coloumn, beams and slabs etc in layers with approved design mix concrete having the specified charateristic compressive strength (with ordinary portland cement coarse sand and graded stone aggregate of 6 mm maximum size in proportion as per design criterial) in the cost of centering and shuttering at edges and corners etc as per direction of Engineer-in-Charge incl chipping of unsound/weak concrete material 50mm average thickness from slabs, beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surfaces and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc incl removal of rust by applying approved rust removal chemical & coating with Dr fixit epoxy zinc primer @ 6 sqm/ltr at DFT of 100 microns as per specification disposal of debries for all lead and lifts complete all as specified and directed by Engineer-in-Charge. Note:- Hard drawn steel wire fabric shall be measured and paid separately.
S&F Hard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia or fixing with reverts plugs or galvanised steel staples supplied and fixed complete to wood or steel members all as specified & directed by Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
M & L applying three coat of white wash on newly plastered or unplastered ceiling surfaces including preperation of surfaces, complete all as specified.
M&L for preparation of old decorated, plastered or pointed surfaces of ceiling and applying two coat of white wash complete all as specified and directed by Engineer-in-Charge.
M & L Preparation of newly plastered wall surfaces and applying three coats of white wash including preparation complete all as specified and directed by Engineer -in -charge .
M & L two coat of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces all as specified and directed by Engineer - in - Charge .
Taking down rolling shutters and refixing to its original position after cleaning all parts, starightening sliding rails, changing damaged strips, bottom rail, helical as required, greasing, oiling, servicing for smooth functioning of all parts completed all as directed for the following sizes :- (a) Exceeding 4.00m x 5.00 m but not exceeding 6.50 x 6.50m
S&F steel rolling shutters 1.25 mm thickness of laths,with bearing,as specified including to cover,anchoring rod,hasp and staple and one shop coat of primer,erected in position as incdicated,complete, push pull or manual operated type, complete all as specified and directed
S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed .
S&F Ball bearing for rolling shutters complete all as specified and directed .
Dismentling Asbestos Cement sheets including ridges in roof coverings
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified bottom coat fixed to steel purlins with galvanised self driver self taping corrosion shield screws 5.50mm dia of required length and as per manufacture specification.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,if bent to a curve (of any radius) fixed with self tapping screws as specified, complete all as specified and directed.
S&F 2 mm Fibre glass reinforced translucent plain sheeting with two plain side lap fixed with coach screw and washer in roof, wall etc.complete all as specified and directed
S&F 0.56 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) after plastering is complete all as specified and directed by GE/ Engineer-in-charge.
S & F Rolled section, MS plate, angles, 'C' Section etc confirming to GDE Fe 410-S as in hip and jack rafter, purlins,ladder etc where connected to common rafters and running rails fixed with other connecting plates.
S&F Mild steel flat iron for wind ties for roof including securing bolts, necessary drilling, bolting or riveting etc and similar work conforming to Fe-210 Gde E-165 complete all as specified and directed.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.40mm and fixed etc., complete all as specified
S & F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane all as specified .
M & L providing two coats of synthetic enamel paint over new steel surfaces and a coat of red oxide primer on including preparation of surface of any description exceeding 10 cm width or girth complete all as specified and directed by Engineer -in -charge.
M&L for preperation of old steel surface and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer -in -charge.
Taking down CI/AC/PVC soil waste and vent pipe any radius including all fittings complete.
S & F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed to wall complete all as specified .
S&F for 110mm bore PVC (SWR) bends any radious provided with access door (Pressure not less than 6kg/cm2) complete all as specified and as directed by Engineer-in-Charge.
Excavation trenches n exc 1.50 wide and n exc 1.50 m depth for foundation etc in any type of soil complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers n exc 25 mm thick soil.
Removing excavated material n exc 250 m and deposited where directed at a level not exc 1.50 m above the starting point.
M&L Providing plain cement concrete Type D-2, 1:5:10 (40 mm graded stone aggregate as in foundation, filling and mass concrete).
M&L for Brick work using fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer -in -charge.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes grade St-240 complete all as specified and as shown on drawing.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-415 -W (Gde -e -250) quality -B complete all as specified and directed.
S & F exc 12mm dia & n. exc 20mm dia exc 30mm long MS screw bolt machine made with hexagonal or Square head at one end and screwed the other,screwed end fixed with washer complete
M& L PCC 1:2:4 type B1, using 20 mm graded agg.as in bed blocks ,coping, hold fast blocks etc. and including form work complete all as specified and directed by Engineer -in -charge.
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil.
Excavating over areas, exc 1.5 m deep but n exc 3.0 m and getting out in any type of soil.
Excavating over areas, exc 3.0 m deep but n exc 4.5 m and getting out in any type of soil.
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level
M&L for PCC (1:5:10) type E2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified .
M&L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in foundation and mass concrete etc complete all as specified and as directed.
M & L Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:6
Lobour only for Brick work built in CM (1:4) with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius with Reusing the old bricks obtained from item no 2 .
M & L for Loose filling with Broken stone Broken or boulders (aggregates of gauge 40 to 80 mm) in soakage pits, soakage wells
M & L for Reinforced cement concrete (nominal mix) in 1:2:4 type B-1 (using 20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M & L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but not exc. 10cm wide
M&L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in benching/ channels of manholes etc complete all as specified and as directed.
M&L for Flush pointing on brick wall in CM 1:4 complete all as specified and directed.
Supply only integral waterproofing compound
M&L for RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in precast manhole covers slab as specified and as directed.
S&F mild steel deformed bars 6 to 8 mm dia and over, cut to length, bent to shape, required , including cranking , bending spirally or hoping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engr in Charge.
M & L Concrete bed to drain pipes for dia 150mm 1:4:8 type D-2 (using 40 mm graded crused stone aggregate) including forming cradles;
M & L Concrete bed to drain pipes for dia 200mm 1:4:8 type D-2 (using 40 mm graded crused stone aggregate) including forming cradles;
S & F for 150mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars
S & F for 200mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars
S&F Cast iron work, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters,sewage line grating and similar articles.
Taking down carefully point wiring complete including fixture and fittings from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. and making good to disturbed area all as specified
Point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories including PVC rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switchs, sockets, fan regulator etc covered with 3 mm thick plastic laminated Hylem top cover sheet of required color fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed for the following all as specified for one light point/Fan point/Exhaust/bell point controlled by one way switch
All as per item no. 68 here-in-before but one 5 pin socket out let 5 amps on the same board with other switches
All as per item no. 68 here-in-before but One 5 pin, 5A switch socket outlet point on independent board
All as per item no. 68 here-in-before but with 2.5 sqmm cable for 1No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified
All as per item no. 68 here-in-before but with 4.0 sqmm cable for 1No 16 amps socket outlet point on independent board including 4.0 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified
supply and fixing in replacement of LED complete fitting including batten, T8 retro LED polycarbonate 1 x 20 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accesssories and following specifications, including taking down old unserviceable light fitting any type complete all as specified and directed by Engr-In-charge:- Crompton Cat Pt No. LDSLRP20-CDL or equavalent of make: Havells/Philips
Supply and fixing in replacement of LED tube light fiting 1x10W, (appx 2 feet long) environment friendly including electric ocnnection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose tolight fitting, complete fitting with all accessrries and following spcifications including taking down old unserviceable light fitting any type complete all as specified and directed by Engr-In-charge Cat Pt No. Crompton LDLL10-CDL or equavalent of make: Havells/Philips
Supply and fixing complete set of 1x10 watt LED retrofit type bulkhead fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down old Unserviceable light fitting any type as specified.
Supply and fixing in replacement energy efficient LED street light fitting of 25W pressuire die cast aluminium housing/body heat resistant clear toughened glass, better optics for uniform distribution street/road way luminaire with driver including electric connection complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type complete all as specified and directed by Engr-In-charge. Havells Cat Pt No. ENDURASUNDOWNSL25WLED 765 PASYBOPCIHD of Make: Crompton/Philips
Supply and fixing LED bulb 1x9 Watt lamp having luminous efficancy, BEE rated LED Lamps and warranty 2 year all as per specified
Supply and fix PVC Angle Lamp holder polycarbonate type with back plate suitable for LED blub up to 9 watt complete all as specified
S&F Piano type switch single pole 1 way 5/6 amps 230 volt AC supply complete all as specified
S&F socket two in one 6/5 Pin 5 Amps 230 volt AC supply complete all as specified
S&F Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified
S&F socket two in one 6/5 Pin 15/16 Amps 230 volt AC supply complete all as specified
M&L ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / PVC / polycarbonate isolated body all as specified
Supply and fix LED type Flood light fitting 200 watt pressure dia cast aluminum housing LED street light luminaries with IP 66 including GI pipe/channel and clamps,nuts,bolts etc with all accessories complete all as specified and as directed. Make Havells Model JETA VALOURFL200WLED757MODWBLTG or equvalent in Make; CG/PhilipsCG/Bajaj
S&F sheet metal enclosure for DB's SPN 230 volts 12 way with 200 amps rated bus bar neautral link, earth bar double door complete all as specified
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified
Supply and fixing amp rating 415V, 10KA 'C' curve miniature circuit breaker (MCB) of TPN 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified
S & F in sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 4 ways s all as specified and directed by Engg-in-Charge.
M&L for submain wiring comprising single core ,4 Runs of 10 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits and conduit fittings/existing concealed PVC conduit and conduit fittings not less than 25 mm dia complete, including provision of 2x10 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main all as specified. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Description all as per item No 90 here in before but ,2 Runs of 6 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
Supply and fixing MCCB TPN ( 4 pole) 160 Amps 415 Volts Adj thermal and magnetic setting of braking capacity 36 KA (Adjustable Thermal and Adjustable Magnetic Release Setting) complete taking down old unserviceable one and making necessary connections as existing and cleaning the terminals with CTC solutions complete all as specified and directed. Make :Havells/LegrandSchneider/HPL/Standard
Supply and fixing MCCB TPN ( 4 pole) 100 Amps 415 Volts of braking capacity 36 KA (Adjustable Thermal and Adjustable Magnetic Release Setting) complete taking down old unserviceable one and making necessary connections as existing and cleaning the terminals with CTC solutions complete all as specified and directed. Make :Havells/LegrandSchneider/HPL/Standard
S&F sheet metal enclouser TPN DB having facility to fix MCCB incomer upto 125Amps and MCBs in outgoing, TPN 8 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as specified.
M&L for 50mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal GL connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers and earth strip protected by 15 mm dia GI pipe medium grade and connected to main distribution board panel/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion including taking down old Unserviceable earthing any type all as specified
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3½ core complete all as specified.
Boring of holes under road, pavement, hard standing by trenchless technology usingn ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
S&F un-reinforced precast concrete cable cover class LV, type I, flat, size 250 mm x 150 mmx40mm laid flat length of cover across the length of cable a complete all as specified and directed by Engr-In-Charge.
M/s Verma Construction Company
RANDHIR AND COMPANY
CHILLANA CONSTRUCTION COMPANY
M/s GURFATEH BUILDERS
LM CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .