| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC L1 and reasonable | |
| 2 | L2₹14.0 L+₹1.5 L (12.0%)Rejected-AOC 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L2 | Rejected-AOC L2 |
Tender Value
₹13.4 L
EMD Value
₹26,720
Closing Date
13 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(U) E/M Meerut Cantt
GE(U) E/M Meerut Cantt
TENDER FOR ITEM RATE CONTRACT FOR CERTAIN SANCTIONED WORKS UNDER GE(U) E/M MEERUT CANTT
2021_MES_482900_2
8363
Open Tender
Miscellaneous Works
Item Rate
90 days
Meerut Cantt
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(U) E/M Meerut Cantt
₹26,720
Yes
11 Jan 2022
24 Nov 2021
15 Dec 2021
24 Nov 2021
13 Dec 2021
1 Dec 2021
90 days
Amount
S&F Energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium housing with polycarbonate or flat glass optical cover, system power euqal to or not less than 48 watt to achieve B1 class road illumination as per IS: 1944 and as per national lighting code each LED >1 watt and <3 watt , Luminous of efficiency of LED >= 135 Lumens/Watt, ,CRI >70, CCT > 5000K to 6500 K with LED life span at 70% of light output >50000 hours (L70) with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 65 or better , driver and luminaire shall comply LM-79/IS:16106 including 32mm nominal bore light grade GI pipe brackets made out of 1.5m long GI pipe, bent to shape, and fixed to poles/ walls with 2 Nos MS mild steel FI brackets of 40x6mm, comprising 4 Nos MS hexagonal head bolts of 12mm dia, 75mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and making connections with PVC copper wire 1.5 Sqmm 3 core etc.e complete all as specified and directed.
Supplying, installatiing, testing and commissioning of 9 metre high hot dip galvanised with singlepiece dip galvanising 65 micron (dft) Octagonal shaped made out of 3mm thick, high tensile steel plates ( yield strength min 355 N/mm2 and tensile strength 490-630N/mm2 ), 70mm (min) at top and 175mm (min) at bottom across face suitable for wind loading for Meerut compring Galvanised base plate 275mmx275mmx16mm (min) , Galvanised 4 Nos 24mm dia 750mm long bolts (EN 8 grade) with 4mm thick anchor plate including necessary excavation, earthwork, PCC 1:2:4 type B1 of size 400mmx400mm 800mm deep complete all as specified and directed by Engineer-in-Charge.
S&F 40 mm nominal bore GI pipe brackets made out of light grade pipe of required length not less than 1.20 M consisting adapter to suit the opening of street light on one end alongwith integrated fabricated adaptor round cup type with 4 Nos studs on outer side to fix the bracket on top of existing steel tubular pole four way with necessary MS clamps with one coat of red oxide and two coats of aluminium paint upon fabricated adopter including nuts, bolts and washers complete all as specified .
S&F Energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium housing with polycarbonate or flat glass optical cover, system power euqal to or not less than 90 watt to achieve B1 class road illumination as per IS: 1944 and as per national lighting code each LED >1 watt and <3 watt , Luminous of efficiency of LED >= 135 Lumens/Watt, ,CRI >70, CCT > 5000K to 6500 K with LED life span at 70% of light output >50000 hours (L70) with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 65 or better , driver and luminaire shall comply LM-79/IS:16106 including 32mm nominal bore light grade GI pipe brackets made out of 1.5m long GI pipe, bent to shape, and fixed to poles/ walls with 2 Nos MS mild steel FI brackets of 40x6mm, comprising 4 Nos MS hexagonal head bolts of 12mm dia, 75mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and making connections with PVC copper wire 1.5 Sqmm 3 core etc.e complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations, laying of pipe and cables etc or for shafts, well cess pits, manholes,pier holes not exceeding 10 sqm on plan ,.including dressing/trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
Returning ,filling in , including spreading , levelling , watering and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour river sand for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . ( Note: Punned thickness shall be measured for the purpose of payment)
M&L laying fly ash old size bricks , straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Supplying and laying or fixing or passing through pipe, including testing and commissioning 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall pvc sheathed 16 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
S&F 3 core , stranded copper conductor cable 2.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade including 20 mm external dia. Rigid non metallic PVC conduit including tees, bends, elbows, reducers, bell mouth tube ends and flat iron clamp 25x3mm suitable for steel tublar LT pole with nuts and bolts and washers fixed at a distance not less than 2.5 Meter centre to centre from junction box to street light fitings complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, checknuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:3:6 type C1 earth pit and Precast RCC cover 40 mm thick duly reinforced with 6 mm dia @100mm c/c TMT bars ,with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any dahage to existing cables of anytype shall be made good by the Bidder without any extra cost to department.
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 25 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 16 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying and fixing 40mm nominal bore Galvanised mild steel pipe /tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified (Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately)
S&F FRP junction box out door type ,of size 250x250x150mm, light weight suitable for pole mounting incl flat iron clamp 40mmx4mm, nut, bolt, washers including bus bar 4 polex 40 Amp and one MCB SP 2Amp, 10 KA and GI nuts and bolts and necessary connector for loop out cable connection and suitable size glands all as specified.
M&L PVC (SWR) gully trap 125/110mm setting with solvent cement all as specified.
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron / Mild steel base plate, CI finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work in soft/ loose soil , PCC 1:3:6 type C2 in foundation and around poles and PCC 1:2:4 type B1 as in plinth block duly finished even and smooth without using extra cement, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting exposed surafces steel tubular poles with two coats of aluminium paint over one coat of red oxide primer and and black bituminous paint on steel surafces embedded in concrete and providing 300 mm wide bands (5 bands/ straps with fluorescent synthetic enamel paint in alternate colour of black and white from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and shown in drg No.TD/EM/1and directed.
Supplying and fixing automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise/ sun set by setting date, time and degree of longitude and latitude without separate light sensors and prewired with suitable size of copper conductor single core PVC insulated and sheathed caable and all mechanism fitted into panel, outdoor type , pole mounted with FI 25x4mm clamps , nuts, bolts and washers dully painted, connecting and testing factory made , epoxy powder coated, Single Phase street light panel, digital 24 hrs, suitable for 6KW (max) complete with 32 Amps TP Contactor, and 40 Amps SPN MCBs and fixed on pole/ wall/ feeder pillar complete all as specified and directed.
Demolition Brickwork or stone boulder masonry/PCC block masonry , built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified.
M&L Brick work with old size fly ash bricks., straight or curved on plan exc 6 m mean radius , built in CM 1:6, complete all as specified and directed.
M&L broken stone hardcore of gauge n exc. 63 mm , deposited , spread and levelled in layer n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
M&L for Cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete
M&L for Damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete 1:2:4 type B0 using 12.5 mm graded stoe aggregate all as specied.
M&L for Providing, cement concrete in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates,
M&L for Reinforced concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
M&L for Reinforced concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
M&L for Reinforced concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter to give rough finish surface of concretecomplete all as specified
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. to give rough finish surface of concretecomplete all as specified
M&L forFormwork to sides of pillars, posts, struts, piers, columns and stanchions to give rough finish surface of concretecomplete all as specified
M&L for Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. to give rough finish surface of concretecomplete all as specified
M&L High strength (TMT) Deformed Mild steel bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips
M&L TMT steel deformed bars up to and including 10 mm dia. in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips complete all as specified.
M&L Plain cement concrete 1:2:4 type B1 , using 20 mm graded crushed stone aggregate, 25 mm thick as in sub floor complete all as specified.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces , in cement and sand mortar 1:6 finished even and smooth without using extra cement complete all as specified.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces , in cement and sand mortar 1:4 finished even and smooth without using extra cement complete all as specified.
M&L prepration of newly plastered surfaces of walls and applying two coats of exterior emulsion paint ( Apex or weather coat) , white or tinted including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
M&L preparation of newly plastered surfaces of walls by brooming down and applying two coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
M&L Non Skid ceramic plain coloured tiles 7 to 8mm thick ( square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. over and including 15 mm thick screeding in CM 1:6 complete all as specified ( screed bed shall not be measured and paid separately).
M&L glazed ceramic coloured tiles, 300mmx200mmx7mm thick , on vertical surfaces such as dados , skirting and risers to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
S&F steel water tubing 20 mm bore with screwed and socket joints, medium grade, galvanised (including short lengths) with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. fixed to walls or ceiling or laid in floors complete all as specified .
S&F steel water tubing 15 mm bore with screwed and socket joints, medium grade, galvanised (including short lengths) with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. fixed to walls or ceiling or laid in floors complete all as specified .
S&F white Low level flushing cistern valveless syphonic action type complete with all fittings all as specified complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts 450mm long all as specified .
S&F 110 mm bore PVC (SWR) pipes single socketed ISI marked IS-13592 , type 'B in any length with rubber ring joints/ solvent ( conforming to IS-14182) cementing joints laid in trenches or in floors complete all as specified.
S&F 75 mm bore PVC (SWR) pipes single socketed ISI marked IS-13592 , type 'B in any length with rubber ring joints/ solvent ( conforming to IS-14182) cementing joints laid in trenches or in floors complete all as specified.
S&F PVC (SWR) junction single, ( Single T ) equal or unequal 75 mm bore (ISI marked) with access door complete all as specified.
S&F PVC (SWR) bends any radius 75mm bore with oval access door complete all as specified.
S&F in repairs fancy type Chromium plated Stop valves, cast copper alloy, long shank, and cup ( concealed type ) screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified.
S&F Pillar taps, cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified.
S&F Fancy type Bib taps, CP, cast copper alloy with crutch or butterfly handle , screwed down , scrwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified and directed.
S&F grating 100mm dia of PTMT (Minimumm weight 25 gram) all as specified and directed.
S&F PVC (SWR) vent cpwl 75mm bore all as specified and directed,
Cutting into existing manholes for connecting 150 mm internal dia new drains, making good to pipe and rendering ,cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished , and reforming benching complete all as specified.
S&F vitreous China EWC wash down water closet pan ( padestal pattern Water Closet white) with seat cover and flushing cistern with twin flush Model No S1013106/S1013108 of make Cera or equivalent including connection to drain pipe complete all as specified.
S&F vitreous china wash basin (WHB) , white , flat back , size 630mm x 450mm including mild steel/ CI brackets, waste fittings , brass Chromium plated 32 mm mm dia for glazed basins etc. with long screw shanks and fly nuts , flange end embedded in red lead cement , 32 mm dia LDPE pipe of required length, including cutting for and pinning in ends of brackets complete all as specified .
S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed, 150 mm length of bolt, ISI marked complete all as specified.
S&F mild steel sliding door bolts, bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nutss , four on bolt plate and two on staple plate and fixed, 250 mm long ( ISI marked) complete all as specified.
S&F butt Hinges, medium weight, cold rolled mild steel, 100 mm size complete all as specified.
S&F Aluminium handles, cast type anodised 'D' shaped , 125mm long ISI marked all as specified.
S&F Rotational moulded poly-ethylene water storage tanks ( cylinderical vertical with closed top ) , 500 litres capacity,ISI marked) ,hoisted and fixed in position complete all as specified.
S&F Gunmetal , globe or gate valves, with iron wheel head, screwed both ends for 20 mm bore dia. iron pipe and fixed complete all as specified.
S&F Stop valves, cast copper alloy, screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified
S&F Ball brass valves, high pressure, with polyethylene float and flynut complete , screwed for 20 mm bore dia. pipe or brass ferrule complete all as specified.
M&L Reinforced Cement concrete in cement concrete mix 1:2:4 type B1 slabs supported on walls, beams and columns , in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
M&L Plain cement concrete type C1 (1:3:6), using 20 mm graded crushed stone aggregate,50 mm thick , as in plinth protection finished even and smooth with using extra cement including providing joints filled with mastic filling complete all as specified.
M&L 150 mm bore Salt - glazed stone ware drain pipes, grade Alaid and jointed including testing all as specified..
M&L Plain cement Concrete ( 1:4:8) type D2 bed to 100 mm bore drain pipes including packing under , and haunching against the sides of pipes after they are laid and tested ;in complete all as specified.
M&L precast cement concrete 1:2:4 type B1 as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified.
Use and waste of formwork to flat soffits of suspended deck slabs, floor slabs, landings and similar work; not exceeding 200 mm thick ( Horizontal or sloping) surfaces finished rough as specified.
S&F powder coated aluminium anodized double/single leaf side hung shutter with frame using aluminium extruded section of size 63.5mmx38.10mm, for side rail 85mmx44.45mm for top rail all as specified and directed.
S&F factory made steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified.
S&F 3 mm thick (nominal) Sheet glass , ordinary quality , in squares, not exceeding 0.50 sqm each pane fixed with oil putty at any height complete all as specified.
M&L preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide Zinc chrome primer complete all as specified.
S&F 3 core , stranded copper conductor cable 2.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade complete all as specified and directed.
Shikha Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .