Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹11.9 L+₹45,063 (3.92%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹13.2 L+₹1.8 L (15.3%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹14.7 L+₹3.3 L (28.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹15.1 L+₹3.6 L (31.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹23.9 L
EMD Value
₹43,800
Closing Date
11 Oct 2023, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur
REWIRING OF MD/OTM ACCN AND CONNECTED WORKS AT 7 AFH KANPUR CANTT
2023_MES_618944_1
GE(AF)/CHK/BR/T-29 OF 2023-24 8872/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
7 AFH Kanpur Cantt
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(AF)B/R Chakeri, Kanpur
₹43,800
Yes
24 Nov 2023
15 Sept 2023
18 Oct 2023
15 Sept 2023
11 Oct 2023
29 Sept 2023
Amount
Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose , pendant holder, fitting and fixtures , MCB DB’s , MCB, Main switches, call bell etc and making good to disturbed surface to wall ,floor etc to match with existing surface either by using same colour distemper or white colour wash as required complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated and unsheathed copper stranded conductor cable of size 1.5 Sq mm , 1100 V drawn in and including PVC casing and capping complete including cast iron/pressed steel terminal box 1.6 mm thick of required size Bakelite sheet 3mm thick for mounting switch , socket, brass screws and washer including PVC insulated and unsheathed solid copper wire of size 1.5 Sq mm will be used as continuous earth wire for the following :- Note:- Wiring shall be done using proper colour coding.
One light /fan point controlled by one, one way switch
One 5/6 Amp socket on the same board with other switch
One 5/6 Amp socket on independent board.
One bell point controlled by one, one way bell push button.
All as per item No 2.00 for One 3 pin 15 Amp socket on independent board with 2.5 sqmm PVC insulated unsheathed copper stranded conductor and earth wire with 2.5 Sqmm
Ditto all as per item No. 2 here-in-before but concealled wiring drawn in and including non metallic PVC conduit 20 mm dia medium grade for the following :-
One light fan point controlled by one way switch.
One 3 pin 5 Amp socket on the same board
One 3 pin 5 Amp socket on independent board.
One bell point controlled by one push bottom switch.
All as per item No 4.00 for One 3 pin 15 Amp socket on independent board with 2.5 sqmm PVC insulated unsheathed copper stranded conductor and earth wire with 2.5 Sqmm
S & F switch piano type 240 V, 5 Amp , SP one way flush type complete all as specified and directed.
S & F bell push 240 V, 5 Amp, SP one way flush type complete all as specified.
S & F socket out let combination multipurpose 3 pin 5 amp, 240 volt and with 2 pin 5 amp out let also flush type (non shuttered) complete all as specified and as directed.
S&F switch socket outlet combination 3 Pin 15 amp, 3 Pin 5 amp out let also flush type (non shuttered) complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin 5 amps all as specified and directed
S&F ceiling rose surface backelite 65 x 20 mm three terminal complete all as specified and directed
S&F for lamp holder metal cased body of brass with back plate complete with and including 5 Watt LED lamp all as specified and directed .
S&F sheet metal enclosure for MCB DB TPN double door, 4 way complete with 200 Amps rated bus bar complete all as specified and directed.
S&F sheet metal enclosures for MCCB distribution board TPN, 4 way double door type including MCCB 4 Pole, 100 Amps, 16 KA fixed type as incomer with 200 amp rated bus bar complete all as specified and directed.
S&F sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed.
All as per item No. 15 here-in-before but for SPN 4 way 240 Volt.
S&F Isolator TPN , 63 Amp 4 pole, 415 Volt complete all as specified and directed.
S&F Isolator SPN , 63 Amp , 240 Volt complete all as specified and directed.
S&F MCB SP upto 32 Amp ,240 Volt complete all as specified and directed.
S&F MCCB 4 Pole 16KA 100 Amps fixed type complete all as specified and directed.
S&F Isolator SPN , 20 to 40 Amp , 240 Volt complete all as specified and directed.
S & F bell electric , 240 Volt , single pole complete all as specified and directed.
S & F fan regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete all as specified and directed.
M& L for earthing complete with galvanized steel earth plate electrode of size 60cm x60 cm x6.0 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthing test point all as specified or indicated including testing on completion including PCC pit in (1:3:6) type C-2 using 40 mm graded stone aggregate and RCC (1:2:4) type B-1 using 20 mm graded stone aggregate for cover slab reinforced with 6mm dia MS bars @ 150mm, 40mm thick with two Nos fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 20mm dia light grade GI pipe for earth wire protection etc. complete all as specified and directed.
M&L for sub main wiring with two runs of single core 4 Sqmm (cross sectional area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and including PVC rigid conduit 20 mm dia with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 4.0 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring commplete all as specified and directed. Note. Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run unit.
All as per item No. 25.00 here in before but 6 Sqmm, 2 single core with PVC FRLS insulated, unsheathed stranded copper conduct cable of size 6 Sqmm as earth lead complete all as specified and directed.
M & L for sub main wiring with three runs of single core 6 Sqmm (nominal area) PVC insulated and unsherthed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and including PVC casing N capping with all necessary fittings and accessories and 02xrun of PVC insulated and unsheathed single core calbe multi stranded with copper conductor of size 6 Sqmm as continouos nuetral and earth wire ( green in colour) respectively, run through PVC casing N capping and connected to the terminal and common earth dolly all as specified and directed.
S & F in repair bulk head fitting of any type with LED bulk fitting wiht 9 watt LED complete connection with copper wire 23/0076 two core from ceiling rose to bulk head fitting complete all as specified and directed Make C& S Model No CG801B6WLED or equivalent model of Philips/ Wipro/ C &S
S & F in repair bed light fitting with LED type surface mounted decorative bed light fitting 10 Watt LED complete with all accessories such as LED driver, LED bulb/rod and LED batten with cover etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting complete all as specified and directed. Make Crompton Greaves Cat Part No LCL-10-CDL or equivalent of C&S/Philips/Wipro
S & F in repair fluorescent tube light fitting complete energy efficient T-8 LED batten and integrated type signle tube 20 Watt, 4 ft long white complete with LED rod, LED driver and LED batten etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting complete all as specified and directed. Make Cormpton Greaves Cat Part No DMLN1LT8-16 and LTT8-20 or equivalent of C&S/Philips/Wipro/Havells as approved by GE in writting.
S & F in repair of existing unserviceable recessed mounted lumanaire with energey efficient 36 Watt LED type including making connection to ceiling rose with copper flexible wire of size 23/0076 complete all as specified and directed. Make Crompton Greaves model No. LCTLS-36-CDL or equilavent model of Philips/Wipro/ Havells/C&S
S & F in repair of modular switch 1 way 6 Amp, 1 module, 240 V flush type complete all as specified and directed.
S & F in repair of modular switch 1 way 16 Amp, 1 module, 240 V flush type complete all as specified and directed.
S & F in repair of modular bell push, flush type, 6 Amp, 1 module, 240 V complete all as specified and directed.
S & F in repair of modular socket, 6A-2/3 pin combined, 2 module, 240 V complete all as specified and directed
S & F in repair of modular socket, 6Amp / 16Amp-2/3 pin combined, 2 module, 240 V complete all as specified and directed.
S & F in repair of modular fan step regulator, 120 W, 2 module, 240 V complete all as specified and directed.
S & F in repair of modular white cover plate with frame, 3 module, complete all as specified and directed.
S & F in repair of modular white cover plate with frame, 4 module, complete all as specified and directed.
S & F in repair of modular white cover plate with frame, 6 module, complete all as specified and directed.
S & F in repair of modular white cover plate with frame, 8 module, complete all as specified and directed.
S & F in repair of modular white cover plate with frame, 12 module, complete all as specified and directed.
S & F in repair of modular metal flush box, 3 module, complete all as specified and directed.
S & F in repair of modular metal flush box, 4 module, complete all as specified and directed.
S & F in repair of modular metal flush box, 6 module, complete all as specified and directed.
S & F in repair of modular metal flush box, 8 module, complete all as specified and directed.
S & F in repair of modular metal flush box, 12 module, complete all as specified and directed.
S&F in repair of electronic ballast for 28 Watt tube light complete all as specified and directed. Make- Bajaj/Crompton/ Philips
S&F in repair Isolator TPN , 100 Amp, 4 pole Isolator, 415 Volt complete all as specified and directed .
S&F in repair of electronic ballast for 2x 36 Watt ceiling light complete all as specified and directed. Make- Bajaj/Crompton/ Philips
S&F in repair LED integrated pattern T5, indoor decoratie aluminium extruted LED fitting 36 watt, 4 feet complete including connection form ceiling rose to T5 LED light fitting with three core PVC flexible wire all as specified and directed Make- Crompton Greaves, C&S, Philips
S&F in repair flexible wire 23/0076 copper conductor from ceiling rose to fitting/fixture complete all as specified and directed.
Taking down carefully storage type water heater (Geysers) 50/35/25 ltr capacity any make by disconnecting electrically and mechanically from all existing lines, opening of bottom and top for inspection; complete including base plate, heating element and copper tank etc, cleaning carefully and reassembling after necessary repair/replacement as specified here-in-after and replacement of old unserviceable nut/bolts and fixing in the same position complete all as specified and directed. (Note :- Parts required for replacement shall be measured and paid separately as "supply only" in respective items)
M&L for minor repair of copper/steel inner tank of Geysers 25/35/50 Ltrs capacity by brazing/gas welding process of length not exceeding 10 cm complete all as specified and directed.
Supply only glass wool for insulation of Geysers any capacity of any make complete all as directed by the Engr-in-Charge.
Supply only inner tank of Geysers 25 Ltr capacity; factory manufactured as approved complete all as specified and directed.
All as per item No. 56 here-in-above but for 35/50 Ltr capacity.
Supply only heating element 1500 watts push type with gasket ISI marked all as specified and directed Make- Theeta/ Bajaj/ Racold
All as per item No. 58 here-in-above but for 2000 watts
Supply only thermostatic switch suitable for Gysers of any make/ type with temperature range adjustable type 25 to 80 degree centigrade superior quality 20 Amps 220 Volts AC complete all as specified and directed. Make- Theetha/ Bajaj/ Racold
S&F non return valve, cast copper alloy ISI marked horizontal/vertical position suitable for any make any type Geysers complete all as specified and directed.
Supply only indicator lamp 220 Volt AC supply rectangular/ circular type as per sample superior quality with neon type lamp of red indicator complete all as specified and directed.
S & F in repair PVC insulated and sheathed copper conductor flexible cable of size 2.5 Sqmm for electrical connection complete all as specified and directed.
Supply and fixing repair pressure release valve as per existing shape and size with inlet coupling ISI marked complete all as specified and directed.
S & F repair bottom split cover for terminal box as per existing shape & size complete all as specified and directed.
S & F repair indoor assebmly suitable for 25 Ltrs capacity Geysers of any type made out of brass with inlet and outlet and fixing plate complete including gasket,nut bolts etc as required and as directed by Engr-in-Charge.
All as per item No. 66 above but for 50/35 Ltr capacity
S & F in repair PVC connection of 450 mm long & 15 mm dia with brass nut at both end suitable for Geysers complete all as specified and directed
S & F in repair chromium plated copper pipe connection 450 mm long & 15 mm dia suitable for Geysers complete all as specified and directed
S & F in repair Bib taps suitable for 15 mm dia of pipe fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and directed
S & F in repair Stop valves, 15 mm dia of pipe fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe fixed complete all as specified and directed.
S & F in repair 15 mm dia GI tubing 'Medium grade' with all fitting fixed to walls and ceilings or laid in floors complete all as specified and directed.
Supply and fixing in repair MCB SP 20 to 32 amps 240 V 10 KA complete all as specified and directed.
S & F in S & F in repair Metal clad SPN enclosure with a two pin and earth plug and socket with one single pole MCB SP 20 Amp,240V complete all as specified and directed. Make -
S & F in repair Metal clad TPN enclosure with a two pin and earth plug and socket with one single pole MCB TP 32 Amp,240V complete all as specified and directed.
M &L for servicing of solar water heater of capacity 100/200/300 Ltrs by taking down from roof of the building ,diconnecting all electric and water connections ,opening tank side covers and base plate, heating element and copper tank etc , checking of serviceability of all parts through well experienced technician, carry out cleaning and descaling of tank and copper tube using proper cleaning agents, cleaning of solar panel , checking of connections for smooth functioning and reassembling after necessary repair/replacement as specified here-in-after including fixing in the same position complete all as specified and directed. (Note :- replacement of old unserviceable part shall be measured and paid separately as supply only) under repeated item of Sch 'A'.
Repair to un-serviceable solar panel for Solar water heater of capacity 100/200/300 Ltrs by opening the panel assembly, find out the defect on circuit,connectins and terminals and carry out repair through well experienced technician , re-assembling and refixing at site and testing all as specified and directed
Supply only heating element 2000 watts push type with gasket ISI marked for solar water heater as per sample all as specified and directed. Make- Theetha/Bajaj/Racold
Supply only thermostatic switch suitable for solar water heater of any make/ type with temperature range adjustable type 25 to 80 degree centigrade superior quality 20 Amps 220 Volts AC Supply complete all as specified and directed.
S & F in repair sub main wiring with three runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and including PVC casing and Caping with all necessary fittings and accessories and 02xrun of PVC insulated and unsheathed single core cable multi stranded with copper conductor of size 6 Sqmm as continuous nuetral and earth wire (green in colour ) respectively, run through PVC casing and capping and connected to the terminal and common earth dolly complete all as specified and directed. (Note. Four run of cable and one run of PVC casing and capping and one run of earth continuity wire shall be measured as one run unit)
S & F in repair hot water GI pipe of 15 mm dia medium grade including all fitting insulated with 50 mm thick rock wool of density 48 Kg/Cum and covered with 26 SWG aluminium sheet cladding complete all as specified and directed.
All as per item No 81 above but for size 20 mm bore
S & F in repair sub main wiring with PVC insulated unsheathed copper conductor cable of 2x 2.5 sq mm + 1x 2.5 sqmm earth wire drawn in and including PVC conduit for solar water heater complete all as specified and directed.
S & F in repair round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connection up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED smart bright street light fitting 45 Watt of IP66 protection with 70 % energy efficient finless design complete including testing complete wlong with connection with copper wire 1.5 Sqmm three core along with suitable bracket nut bolts washers complete all as specified and directed.
santosh electronics
S B ENTERPRISES
LARSEN AIR CONDITIONING & REFRIGERATION
M/S PASHUPATI TRADERS
SAKSHAM SUPPLIERS BUILDERS
Preetpowercontrol
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .