| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹19.8 L+₹1.6 L (8.60%)Rejected-Finance MANDI PILIBANGA HANUMANGARH RAJ | HANUMANGARH | RAJASTHAN | 335063 | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹21.3 L+₹3.1 L (17.1%)Rejected-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 | AJMER | RAJASTHAN | 305001 | L3 | Rejected-Finance HIGHEST | |
| 4 | L4₹22.7 L+₹4.5 L (24.6%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L4 | Rejected-Finance HIGHEST |
Tender Value
₹23.5 L
EMD Value
₹47,080
Closing Date
17 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI T C SHISHODIYA, DCWE(C)
MULTAN LINE ARMY AREA JODHPUR
RENDERING SERVICES FOR OPERATION AND MAINT OF 33KV MRS AND COMPLAINT CELL AND ALLIED ITEMS AT MRS AT ARMY AREA BANAR
2020_MES_385641_2
CWE (A) JODH/BNR-82 OF 2020-21
Open Tender
Civil Works
Item Rate
330 days
GE Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Banar
₹47,080
Yes
17 Feb 2021
1 Dec 2020
18 Dec 2020
1 Dec 2020
17 Dec 2020
3 Dec 2020
60 days
Amount
Rendering Services for operation of main receiving station (33/11KV) Sub Station at ABOD area under GE Banar contineously round the clock three shift per day, 01 Nos skilled operator in each shift (each shift of 08 hours contineous duration ) for effeciently maintaining the following as under etc complete all as specified and directed by Engineer-in Charge. Note : Power factor at 33 KV main incoming to be maintained above 0.95, any penalty on account of power factor in billing will be recovered from contractor dues. Power transformer , 33/11 KV, 2000 KVA & 3150 KVA, outdoor type - 2 No.HT VCB, 33 KV outdoor type incl indoor type C & R panels- 2 No.Sub Station Transformer 33/.433 KV,63 KVA - 1 No,Battery Bank and battery charger - 3 Set.Capacitor bank 11 KV - 2 Set, checking of Two pole /four pole structure of GODs and Drop out fuses 33 KV and 11 KV Cleaning of the complete electric installation daily (inside and out side) incl maintaing garden Maintaining log sheet hourly basis for incoming and out going supply very neatly. Maintaining shut down/break down records register Replacement of blown up fuses as and when requird, Promptly attending and rectification of faults/break down of HT/LT lines/cables inside MRS. Note : Refer Srl No 03 on Page No 104.
Rendering services for operation of Sub station (11/0.433KV) at Msl Regt area under GE Banar contineously round the clock in three shift per day , 01 Nos of skilled operator in each shift (each shift of 08 hours continous duration) efficiently complete all as specified and as dircted by Engineer-in -Charge. Maintaining and operation of the following: Sub Station transformer , 11/0.433 KV, 400 KVA indoor type - 1 No. HT VCB, 11 KV indoor type- 1 No.LT Panel and APFC Panel indoor type-2 No.DG Set 100 KVA- 1 No, DG Set 25 KVA - 1 No.Battery Bank and battery charger - 1 SetDistribution Panel and Timer Panel of the area- 13 Nos Cleaning of the complete electric installation daily (inside and out side) incl maintaing garden Maintaining log sheet daily basis for incoming and out going supply very neatly Maintaining shut down/break down records register. Replacement of blown up HT/LT fuses as and when requird. Note : Refer Srl No 03 on Page No 104
Rendering services of services effeciently for elect supply complaint cell in one shift of 08 hrs for 01 Nos skilled electrician in each shift attending/rectification all kind of external/internal HT/LT electrical supply complaints to the satisfaction of user pthe area pertaining AOR unde GE Banar and all as directed by Engineer-in-Charge. Note : Refer Srl No 03 on Page No 104
(B) Supply of Material Supply Only the tin coated copper wire of current carrying capacity 10Amp to 60Amp rating suitable for replacing the burnt fuse wore at MRS
Supply Only the female contact suitable for vertically operated airbreak switch of 200 Amp rating with nut bolts and all as directed.
Supply Only the male contact suitable for vertically operated airbreak switch of 200 Amp rating with nut bolts and all as directed.
Supply Only the flexible jumper with GI guiding frame suitable for vertically operated airbreak switch of 200 Amp rating with nut bolts and all as directed.
M&L For replacing the loose/rusted/deteriorated ACSR jumpers at MRS 2/4 pole structure of suitable size/type of ACSR conductor with suitable insulaton materials and all as specified and directed.
Supply only the mild steel fully threaded bolts with nut and with one No of washer of various sizes in llength and dia and all as specified and directed by Engr-in-Charge.
SARASWATI ELECTRIC STORE
M/S JAGDAMBA ENTERPRISES
Shri Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .