Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹28.7 L+₹83,106.40 (2.98%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹31.0 L+₹3.1 L (11.0%)Rejected-Finance 15 BAGHE ISLAM NEAR NH BY PASS BRIDGE LAL NAGAR CHANAPORA SRINAGAR JAMMU KASHMIR 190015 | SRINAGAR | JAMMU AND KASHMIR | 190015 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹32.6 L+₹4.7 L (16.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹34.2 L+₹6.3 L (22.6%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
31 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/O 56 APO PIN 913970
REPAIR AND MAINT OF EXTERNAL ELECTRIC NETWORK INCLUDING LT OH LINES UG CABLES CABLE JOINTS LT POLES INSULATOR STAY ASSY ETC AND CONNECTED WORKS AT OLD AIR FIELD UNDER GE 970 EWS
2022_MES_566782_1
GE 970 EWS-55/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 970 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹86,000
Yes
6 Mar 2023
2 Dec 2022
2 Jan 2023
2 Dec 2022
31 Dec 2022
17 Dec 2022
Amount
Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr in wide and not exc. 1.5m in depth for taking out / laying of under ground cable in trenches or cable ducts complete all as specified & directed.
Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr in wide, exceeding 1.5 m depth and not exc. 3.0 m in depth for taking out / laying of under ground cable in trenches or cable ducts complete all as specified & directed
Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables complete all as specified & directed
Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified & directed
M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I complete all as specified & directed. Note : punned thickness shall be measured for payment purpose
Supply and lay brick of conventional size 230x110x75mm locally available as protection of cable in trenches complete all as specified & directed.
Laying only of serviceable bricks of any size and type recovered during taking out of old cable, over newly laid or re-laid cables complete all as specified & directed.
M&L for 50mm dia GI pipe medium grade for cable protection and sealing both ends including taking out old pipe complete all as specified & directed
M&L for 80mm dia GI pipe medium grade for cable protection and sealing both ends including taking out old pipe complete all as specified and directed.
M&L for 40mm dia GI pipe medium grade for cable protection and sealing both ends including taking out old pipe complete all as specified and directed.
Taking down old unserviceable LT UG cable from any description (tranches, walls, ceilings.,etc) from various locations, including any length, supply and laying under ground LT cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 16 Sq mm, 4 core, with aluminium conductor with suitable size aluminium cable lugs and jointed in any description complete all as specified and directed. NOTE:- 1. Excavation , concrete cable protection bicks, pipe, PCC work for crossing/hard standing and sand for cushioning will be measured and paid separately. 2. Cost of aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), gable gland, new nut bolt and washers of required size shall be deemed to be included in the unit rate quoted by the tenderer.
All as per item Sl No 11 above but of size 16 sqmm 2 core
All as per item Sl No 11 above but of size 25 sqmm 4 core
All as per item Sl No 11 above but of size 35 sqmm 3.5 core
All as per item Sl No 11 above but of size 50 sqmm 3.5 core
All as per item Sl No 11 above but of size 70 sqmm 3.5 core
All as per item Sl No 11 above but of size 95 sqmm 3.5 core
All as per item Sl No 11 above but of size 120 sqmm 3.5 core
All as per item Sl No 11 above but of size 185 sqmm 3.5 core
All as per item Sl No 11 above but of size 150 sqmm 3.5 core
All as per item Sl No 11 above but of size 10 sqmm 4 core
All as per item Sl No 11 above but of size 10 sqmm 2 core
M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 35 to 50 sqmm x 3.5 core cables including testing and commissioining complete all as specified & directed Make : Densons / 3M / Raychem
All as per item Sl No 23 above but of size 70 to 150 sqmm x 3.5 core, as per the size of existing UG cable complete all as specified & directed. Make : Densons / 3M / Raychem
All as per item Sl No 23 above but of size 185 to 300 sqmm x 3.5 core, as per the size of existing UG cable complete all as specified & directed. Make : Densons / 3M / Raychem
Material & labour in repairs ACSR conductor any size from poles including stringing on LT poles complete including aluminium binding wires, jumpering, bindings at insulators etc complete all as specified and dirceted.
BLANK
BLANK
BLANK
Supply & fixing in repair 400 A 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable over load and short circuit with micro processor release setting including necessary cable lugs & wire etc complete all as specified and directed
Supply & fixing in repair 250 A 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable over load and short circuit with micro processor release setting including necessary cable lugs & wire etc complete all as specified and directed
Supply & fixing in repair 200 A 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable over load and short circuit with micro processor release setting including necessary cable lugs & wire etc complete all as specified and directed
Supply & fixing in repair 160 A 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable over load and short circuit with micro processor release setting including necessary cable lugs & wire etc complete all as specified and directed
Supply & fixing in repair 125 A 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable over load and short circuit with micro processor release setting including necessary cable lugs & wire etc complete all as specified and directed
Supply & fixing in repair 63 A 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable over load and short circuit with micro processor release setting including necessary cable lugs & wire etc complete all as specified and directed
M&L in repair for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel, complete all as specified and testing on completion.
Disconnecting the windings of loose overhead conductors of LT lines from insulators and restringing the same for proper sag and rewinding incl aluminium winding wires, tapes etc and jumpering for any type of conductor complete of single run conductor complete all as specified & directed. Note: Triming of tree branches around the pole upto 3 mtr is deemed to be included in the rates quoted.
Taking out old unserviceable steel tubular/RCC poles 9 mtr long and supply and erection of steel tublar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle acomplete all as specified & directed
Supply and fixing in replacement of insulator pin type porccelain viterious, white brown or green insulator including one galvanised mild steel spindle, two galvinised washers and one GI nut 100 mm hight and 65 mm dia for 1100 Volt grade complete all as specified and directed.
Supply and fixing in replacement of insulator shackle type porccelain viterious, white brown or green insulator including one galvanised mild steel strap, washers, insulator bolts, washers and nuts for working preasure 100 mm hight and 65 mm dia for 1100 Volt 115 mm dia, section of strap (31 x5) mm dia of bolt 14mm complete all as specified and directed.
Supply and fixing PVC line spacer (Separator) of superior quality of 4 way spiral type for three phase over head conductor complete all as specified and directed
Supply and fixing PVC line spacer (Separator) of superior quality of 6 way spiral type for three phase over head conductor complete all as specified and directed
Supply and fixing PVC line spacer (Separator) of superior quality of 2 way spiral type for street light over head conductor complete all as specified and directed
M & L for Painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia all complete all as specified & directed
Supply and fixing in repair on load change over switch in sheet metal enclosure of capacity 4P 250 Amps front / side operate type, complete all as specified and directed.
Supply and fixing in repair on load change over switch in sheet metal enclosure of capacity 4P 400 Amps front / side operate type, complete all as specified and directed.
Supply and fixing in repair on load change over switch in sheet metal enclosure of capacity 4P 200 Amps front / side operate type, complete all as specified and directed.
Supply and fixing in repar LED floor light fitting of 150 watts with driver inside a pressure die cast alumnium housing with toughened front glass cover, IP65 degree of protection complete all as specified and directed. MAKE:-Bajaj cat No. BJFL 150W LED I / Havells /Wipro / Crompton Greaves.
All as per item No. 48 here-in-before but of 200 watts ---ditto--- MAKE:-Bajaj cat No. BJFL 200W LED I / Havells/Wipro/Crompton Greaves.
All as per item No. 48 here-in-before but of 240 watts ---ditto--- MAKE:-Bajaj cat No. BJFL 240W LED WH MB / Havells/Wipro/Crompton Greaves.
Supply and fixing in repair LED street light fitting 45 watts with high efficency long life LEDs in built replaceble electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection complete all as specified and directed. MAKE:- Bajaj cat No. ENXT P 54L WH CR PC SD/ Havells/ Wipro/ Crompton Greaves
All as per item No. 51 here-in-before but of 60 watt ---ditto--- MAKE:- Bajaj cat No. ENXT P 72L WH CR PC SD or latest upgarded equivalent modle in Havells/Wipro/Crompton Greaves
All as per item No. 51 here-in-before but of 70 watt ---ditto--- MAKE:- Bajaj cat No. ENXT P 84L WH CR PC SD / Havells/ Wipro/Crompton Greaves
All as per item No. 51 here-in-before but of 90 watt ---ditto--- MAKE:- Bajaj cat No. BRTFG 90W LED CR / Havells/ Wipro/ Crompton Greaves
All as per item No. 51 here-in-before but of 120 watts ---ditto--- MAKE:- Bajaj cat No. BRTFG 120W LED CR /Havells/Wipro / Crompton Greaves
Supply and fixing in repair LED post top light fitting made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection 40 watts with high efficiency long life LEDs In-built replaceable electronic driver ccomplete all as specified and directed. MAKE:- Bajaj cat No. BGCL 40W LED WH / Havells /Wipro / Crompton Greaves
Supply and fixing in repair integral LED aviation obstruction light luminaire comprising of yello painted LM6 aluminium alloy housing polycarbonate encloser complete all as specified and directed. MAKE:-Bajaj/Crompton Greaves/Havells/Wipro.
Taking down of high mast light, hot dip galvanised mast 15/16 M high and luminairies carriage duly opening of nut & bolt at bottom with the help of Hydra/Crane for repair/replacement of old UNSV winch and steel wire ropes (as per existing) complete with ratchet, limit switches etc as per standard engineering practice to avoid falling of carrirer during raising of lowering and re-installation, testing at site and comissioning after satisfactorily repair complete all as specified and directed.
Material & labour in replacement of GI pipe bracket made out of galvanised iron tubing 32/40mm bore (dia), light grade, 1.20 M long bent to shape as per specified for fixing street light fitting including suitable size of clamps and applying two coats of aluminium paint over a coat of aluminium primer complete all as specified and directed.
Material & lalbour in replacement of cable junction box/ distribution board IP 65 with metric knockouts for cable entry of size 10 to 25 Sqmm x 2 core including fastening clamp with LT pole, box size : 333 x 233 x 120 mm (or nearest higher size) hinged cover with locking arrangements including with terminals TPN strip, with 01 No. MCB SP 6A complete all as specified and directed.
Supply and fix in repair mild steel cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete including painting with 2 coats of alumunium paint over a coat of red oxide primer after preparation of surfaces complete all as specified and directed.
Material & labour in repairs for sub main wiring using FR insulated unsheathed, multistrand copper conductor FR-LS PVC cable 2 runs of size 2.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing, drawn through rigid PVC conduit 20 mm dia with clamps for fixed on pole for connection from junction box to light fitting/switch complete all as specified and directed. NOTE:- Two runs of cable for phase / neutral and one run of cable for earth including conduits shall be measured and paid as one unit length.
Material & labour for PCC 1:4:8 type D2 using 40mm stone aggregate for pole foundation complete all as specified and directed.
Material & labour for PCC 1:3:6 type C-1 using 20mm stone aggregate for coping of poles etc complete all as specified and directed.
Material & labour in repairs of lead acid bty 12 Volt 180 AH for UPS system complete all as specified and directed. MAKE:- (Exide express /AMMRON/LUMINOUS/MICROTEK
Material & labour in repairs danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT 20 x 15 cm size complete all as specified and directed.
All as per item No.68 here in before but for HT 25 x 20cm size ---ditto---
Material & labour in repair HT/LT MS cable route indicator 5" to 6" dia fixed with two Nos of nut, bolt and washers and provision of PCC 1:4:8 type D-2 using 40mm grade stone aggregate of not less than 0.02 cum in each at base buried under the ground including necessary earth work complete all as specified and directed.
Material & labour in repairs copper strip 20 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed.
Material & labour in repairs copper strip 32 x 6mm buried in groundcomplete all as specified and directed.
Material & labour in repairs Galvanised iron strip 32x6 mm buried in ground complete all as specified and directed.
Suuply & fixing in repairs aluminium cable lugs let (Ring) heavy duty / bottle neck type for the following size of cable including cutting the existing burnt out /UNSV/damaged lugs from existing cable by taking out loop / looses cable from the position including cutting the damaged portion and preparation work and connecting to any description complete all as specified and directed:-
16 Sqmm Cable
25 Sqmm Cable
35 Sqmm Cable
50 Sqmm Cable
70 Sqmm Cable
95 Sqmm Cable
120 Sqmm Cable
150 Sqmm Cable
185 Sqmm Cable
240 Sqmm Cable
300 Sqmm Cable
Material and labour in repairs for stay assembly complete with all section such as stay plate, stay clamps, stay brackets with 20mm dia stay rod complete all as shown in electrical plate No 1 of SSR Part-I complete all as specified and directed NOTE : Loop insulator, excavation and concrete work will be measured and paid separtely.
Material and labour as in repairs for stay strand size 7/3.15 mm complete all as specified and directed
Material and labour as in repairs loop type insulator vitreous porcelian white, brown or green of size 65x90 mm overall dimension and 16mm clearance of hole complete all as specified and directed
M/S M.Y Enterprises
M/S Manzoor and Co
M/S Sultan Enterprises
FG CONSTRUCTION
M/S Noor Mohammad Shalla
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .