Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.4 CrAccepted-AOC | ₹9.4 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹10.9 Cr+₹1.6 Cr (16.6%)Rejected-Finance | ₹10.9 Cr+₹1.6 Cr (16.6%) | L-2 | Rejected-Finance Being not L-1 |
| 3 | L-3₹11.0 Cr+₹1.6 Cr (16.9%)Rejected-Finance | ₹11.0 Cr+₹1.6 Cr (16.9%) | L-3 | Rejected-Finance Being not L-1 |
| 4 | L-4₹11.3 Cr+₹1.9 Cr (20.8%)Rejected-Finance 14 KISHANGARH WEST IDGAH AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | ₹11.3 Cr+₹1.9 Cr (20.8%) | L-4 | Rejected-Finance Being not L-1 |
| 5 | L-5₹11.5 Cr+₹2.1 Cr (22.9%)Rejected-Finance | ₹11.5 Cr+₹2.1 Cr (22.9%) | L-5 | Rejected-Finance Being not L-1 |
Tender Value
₹9.9 Cr
EMD Value
₹8.2 L
Closing Date
13 Sept 2023, 6:00 pmClosed
HQ,Chief Engineer Lucknow Zone 17, Cariappa Road
HQ,Chief Engineer Lucknow Zone 17, Cariappa Road Cantt,Lucknow-02
CONSTRUCTION OF KLP FOR 252 PARA AD BTY AT AGRA.
2023_MES_609955_1
CELZ/AGR/T-15 OF 2022-23
Open Tender
Civil Works
Lump-sum
540 days
GE (E) Agra
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE (East) Agra
₹8.2 L
Yes
14 Oct 2023
20 Jul 2023
15 Sept 2023
20 Jul 2023
13 Sept 2023
7 Sept 2023
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Road & Hard Standing )
Total amount of Sch 'A' Part VI (Area Drainage)
Total amount of Sch 'A' Part VII (Sewage Disposal)
Total amount of Sch 'A' Part VIII (External Water Supply )
Total amount of Sch 'A' Part IX (External Electrification )
Total amount of Sch 'A' Part X (Lightening Arrester)
Total amount of Sch 'A' Part XI (DEMOLATION AND DIMANTLING )
Sch 'A' Part - XIII (Miscellaneous Items for B/R & E/M Works) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
INTERNAL WATER SUPPLY S&F Two way angle cock angle valves, 15mm, cast copper alloy,fancy type CP, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed.
S&F CP health faucet with 1.5 m long chord , 15mm including fixing of brackets complete fixing arrangement complete
INTERNAL ELECTRIFICATION M&L for Point wiring complete for One light/Fan/Exhaust Fan/Bell point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Ditto all as item No. 13.03 above but except pressed GI concealed terminal boxes & top cover 3 mm thick plastic laminated sheets for modular box .
M&L for Point wiring complete for One light point controlled by two way switches with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Ditto all as item No. 13.05 but except pressed GI concealed terminal boxes & top cover 3 mm thick plastic laminated sheets for modular box .
M&L for point wiring complete with PVC insulated and unsheathed, FRLSH cable 2.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia medium grade PVC conduit concealed in wall and PVC conduit in roof/floor slab, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories and all as specified. Note :-one circuit controlled by one point only.
Ditto all as item No. 13.07 but except pressed GI concealed terminal boxes & top cover 3 mm thick plastic laminated sheets for modular box.
M&L for point wiring complete with PVC insulated and unsheathed, FRLSH cable 2.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia medium grade PVC conduit concealed in wall and PVC conduit in roof/floor slab, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories and all as specified. Note :-one circuit controlled by maximum 4 point only.
Ditto all as item No. 13.09 but except pressed GI concealed terminal boxes & top cover 3 mm thick plastic laminated sheets for modular box .
Supply and fixing Switch flush type 5/6 Amps single pole two way complete all as specified and dierected.
Supply and fixing modular metal flush box for 8 module complete all as specified and dierected.
Supply and fixing LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification complete all as specified and directed.
Supply and fixing LED light fitting 1 x 16 watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connection up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification.complete all as specified and directed.
S&F LED Building security light fitting 25 Watt with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <20 W (24W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
Supply and fixing LED Luminaire 600 mm x 600 mm 36 watts 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof/ ceiling/surface mounting type including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specifed and directed.
S&F LED Lamp 10 Watt retrofit type complete all as specified and directed .
Supply and fixing Ceiling fan 1200 mm sweep BLDC single phase 230V AC and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long for connection complete all as specified and directed
Supply and fixing Ceiling fan 1400 mm sweep BLDC single phase 230V AC and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long for connectioncomplete all as specified and directed.
Supply and fixing Exhaust Fan heavy duty mettalic body, resistant to colour change 300 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed.
Supply and fixing Exhaust Fan heavy duty mettalic body, resistant to colour change 450 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed.
Supply and fixing Flame Proof Exhaust Fan heavy duty mettalic body, resistant to colour change 300 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed.
S&F VTPN DB 4 way double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete without MCCB and with enclosure blank plates for unused way suitable for 4 way all as specified and directed .
S&F MCB FP,415 V 10 KA 'B' curve and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
S&F MCB SPN 32 to 40 Amps 'B" series,,10 KA 240 Volts ,AC complete all as specified and directed.
S&F MCB single pole 6- 32 Amp rating 'B' Series,10 KA 240 Volts,AC 50 Hz ,ISI marked all as specified and directed .
M&L for Submain wiring with two single core 4 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 20 mm dia concealed in wall surface / ceiling for sub main connection including 4 sqmm PVC insulated multistranded unsheathed FRLSH copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Submain wiring with four single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit medium grade not less than 25 mm dia concealed in wall surface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor FRLSH used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Four single core 6 sqmm copper conductor, one run PVC conduit and two run of 6 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Submain wiring with two single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit medium grade not less than 25 mm dia concealed in wall surface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed FRLSH copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Two single core 6 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. below ground level connecting to galvanised earth lead wire 4.0 mm dia as earth lead upto 7.5 meters long connected by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe medium grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 3mm fixing with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR Part-I and connection all as specified and testing on completion. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt,20/ 40mm dia, medium grade, GI pipe as protection to GI wire 4.0 mm as main earthing lead from earth electrode to main TPN MCCBs DB/MCB DB/ test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing and testing complete all as specified and dircted. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Earthing wire beyond 7.5m shall be measured and paid separately.
ROAD PATH & CULVERT S&F dual directional reflective cat eye of impact resistant plastic 100 x 80 x 15 mm ultra violet resistant yellow colour having micro prismatic/cube corner reflectors suitable for fixing with 2 steel zinc plated 12x120 mm nails+epoxy/bitumen adhesive complete all as specified and directed.
M&L for painting lines,dashes,arrows,letters etc. on roads pavements with colour as directed by Engr-in-charge exc 10 cm wide and 2.5mm thick with hot thermostatic road marking materials with mechanical markers incl necessary preparation complete all as specified and directed.
SEWAGE DISPOSAL RCC Septic tank for 25 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as speci-fied and shown on drawings No. TD-750 Sheet 1/2 & 2/2.
RCC Septic tank for 50 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as speci-fied and shown on drawings No. TD-750 Sheet 1/2 & 2/2.
RCC Septic tank for 150 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as speci-fied and shown on drawings No. TD-750 Sheet 1/2 & 2/2.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth complete all as speci-fied and shown on drawings No. TD-576 Sheet 1/2 & 2/2.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 M dia X 3.0 M effective depth complete all as speci-fied and shown on drawings No. TD-576 Sheet 1/2 & 2/2.
EXTERNAL WATER SUPPLY M&L for 100 mm bore centrifugally cast (spun) ductile iron pressure pipes for water mains with socket & spigot ends suitable for tyton joint conforming to IS 8329/2000 and length for classification of K7 suitable for tyton joint complete all as specified and directed.
S&F Sluice valve 100mm bore both ends flanged class PN 1.0 with brass spindle and 01 No hand wheel including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size necessary including testing complete all as specified and directed.
S&F Sluice valve 80mm bore both ends flanged class PN 1.0 with brass spindle and 01 No hand wheel including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size necessary including testing complete all as specified and directed.
Construction of brick masonary valve pit chamber of size 900mm x 900 mm x 900mm (internal dimensions ), 100mm thick PCC 1:4:8 type D2 (40 mm graded stone aggregate) as in lean concrete foundation, fly ash brick work built in CM 1:6 including necessary excavation and earth work, PCC work in the foundation and top of the wall, 15 mm thick plaster on internal surfaces with CM 1:6, finished even smooth using extra cement and 15mm thick in CM 1:4 externally finished fair and even including Mild steel cover 3 mm thick with 2 Nos MS hinges, welded to and including angle iron 40mmx40mmx6mm frame with lifting hook including locking arrangements and MS hold fast and handle made out of 25x6 mm flat iron with lock and key of 65 mm pad lock (pad lock brass 6 levers with key in duplicate), duly painting the steel surfaces with two coats of synthetic enamel paint over one coat of Red oxide primer complete all as specified shown on drawing and as directed.
Construction of brick masonary valve pit chamber of size 600mm x 600 mm x 600mm (internal dimensions ), 100mm thick PCC 1:4:8 type D2 (40 mm graded stone aggregate) as in lean concrete foundation, fly ash brick work built in CM 1:6 including necessary excavation and earth work, PCC work in the foundation and top of the wall, 15 mm thick plaster on internal surfaces with CM 1:6, finished even smooth using extra cement and 15mm thick in CM 1:4 externally finished fair and even including Mild steel cover 3 mm thick with 2 Nos MS hinges, welded to and including angle iron 40mmx40mmx6mm frame with lifting hook including locking arrangements and MS hold fast and handle made out of 25x6 mm flat iron with lock and key of 65 mm pad lock (pad lock brass 6 levers with key in duplicate), duly painting the steel surfaces with two coats of synthetic enamel paint over one coat of Red oxide primer complete all as specified shown on drawing and as directed.
Taking up/down existing 80mm bore GI pipe lines/water mains of any description and in position including fittings, accessories and fixtures etc except control valves existing in between pipe line, by taking out and opening any type of joints complete all as specified and directed .
DI/Cast iron fitting like bends (any type. radius and angle). tapers any type (straight. bend, increasing, decreasing or double socket etc), tee pieces. single branch, 'Y’juncdon, double branch, cross (all sockets or socket & spigot/flanged ) collars, caps and plugs for spigot sockcted pipes upto 150mm bore any type complete.
Taking up/down existing Sluice valve of 80mm bore complete all as specified and directed .
Taking up/down existing Gate valve 50/40mm bore complete all as specified and directed.
Taking up/down existing Gate valve 25 mm bore complete all as specified and directed.
EXTERNAL ELECTRIFICATION M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 80mm /100mm bore HDPE of any description below/under existing road surfaces / floors at a level not less than 0.60 mtr etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed by Engineer-in-Charge. Note : (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt.
Supply and laying 11 KV (Earthed) , cross sectional area 120 Sqmm 3 Core, aluminium conductor, screened, XLPE insulated , armoured shielded and PVC sheathed cables ISI marked, IS 7098 (Part-II) amended upto date triple entruded, complete all as specified and directed. Note- Excavation and Earth work shall be measured and paid under respective Schedule.
Disconnecting carefully and shifting of existing transformer upto 100 KVA to new location using special T&P and making connections means electrically and mechanically to make it functional complete all as directed.
Supply installation, commissioning and testing of transformer ( Energy efficient, EEL-2, Level-2) copper wound step down 200 KVA out door type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed air naturally cooled (ONAN Type), with external cooling tubes/radiators, Double wound core type copper wound having no load voltage ratio 11 KV/415 Volts corresponding to principal tapping,delta connected primary side (HV Side) and star connected on secondary side (LV Side) in accordance with vector symbol DYN 11 (Vector group-4) with neutral brought out on LV side and having tapping on HV side for constant out put so as to altervary secondary voltage from ± 2 ½ %, ± 5% and ± 7 ½ % in step to be changed by mean of manual off load tap changing arrangements complete confirming to IS-1180 Pt-I 2014 with latest ammendment at time of installation) all as specified. The transformer shall be complete with following fittings and acessories cosisting as per details mentioned in Annexure- A to BOQ. NOTE :- (i) Annexure- A to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all puroose. (ii) Drawing should be approved by GE before placing the order. (iii) Transformer shall be platformed mounted as per TD drawing No TD-699 sheet 1/1 complete and rates quoted against this item shall be deemed to include for this provision . (iv) The contractor shall arrange factory visit as detailed by accepting officer to check the above system. (v) Transformer should be 5 star rated and internal losses not more than 1% allowed.
Supply,installation,testing & commissioning of RMU consisting of Load break switch-03 nos and 01 no Vacuum Circuit Breakers with control,12 KV, 50Hz, lightening impulse 75KV peak (outdoor type) with IP 54 protection SF 6 insulated compact switch gear equipped with vacuum circuit breaker devoloped according to international standered ICE 62271-200 intensive to environmental conditions in compact verson with stainless steel tank and comprising, 630 amps LOAD BREAK SWITCH anc VACUUM CIRCUIT BREAKER 630 Amps with protective relays alongwith compact battery, cable termination from the front of side/back side, breaking capacity min 20/21 KA/3 sec enclosed in metallised cast resin/stainless steel enclosure, complete all as specified and tested as per latest IEC rules 62271-200. (Design and Specification of Unit comprising LBS and circuit breaker with relay such as earth fault over load and short ckt capacty adjusted upto 10 to 100 amps along with metering and interlocking arrangement shall be directed by engineer in charge) with foundation base as recommended by manufacturere complete with all accessories for the following as per details mentioned in Annexure- B to BOQ.
Supply, installation, testing and commissioning of SF 6 CIRCUIT BREAKER 400 Amps ( Out door ), 12 kV, 50 Hz, lightning impulse 75 KV peak ( outdoor type ) with IP 54 protection SF 6 insulated compact switch gear equipped according to international standered ICE 62271-200 intensive to environmental conditions in compact verson with stainless steel tank and comprising, 400 amps LOAD BREAK SWITCH and protective relays for adjustable relay to protect transformer upto 200 to 615 KVA alongwith compact battery , cable termination from the front of side/back side, breaking capacity min 20/21 kA/3 sec enclseod in metallised cast resin/stainless steel enclosure, complete all as specified and tested as per latest IEC rules 62271-200 including supply of control circuit 230 Volt with suitable size of copper wire complete all as specified and directed.
S&F Cable route/path indicator made out of 40 x 40 x 4 mm angle iron, 1 mtr long and plate of size 100 x 150 x 6 mm welded only on one side end having embosed on plate as "cable LT" including PCC of size 30 cm x 30 xm x 30 cm duly embedded the angle iron including excavation/earth work complete all as directed.
Supply, installation, testing and commissioning outdoor type cubical panel board suitable for 3 phases, 4 wire, for 415 volts, 50 Hz , 415 volts, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns provided with suitable gasket to make it dust / vermin proof & general construction comprising of the following complete with all accessories as per details mentioned in Annexure- C to BOQ.
Supply, installation, testing and commissioning outdoor type cubical panel board suitable for 3 phases, 4 wire, for 415 volts, 50 Hz , 415 volts, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns provided with suitable gasket to make it dust / vermin proof & general construction comprising of the following complete with all accessories as per details mentioned in Annexure- D to BOQ.
Supply, installation, testing and commissioning outdoor type cubical panel board suitable for 3 phases, 4 wire, for 415 volts, 50 Hz , 415 volts, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns provided with suitable gasket to make it dust / vermin proof & general construction comprising of the following complete with all accessories as per details mentioned in Annexure- E to BOQ.
Supply and laying in trenches/pipe/on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS:7098 ( Pt I) with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed
Supply and laying in trenches/pipe/on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS:7098 ( Pt I) with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed
Supply and laying in trenches/pipe/on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS:7098 ( Pt I) with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed
Supply and laying in trenches/pipe/on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS:7098 ( Pt I) with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed
Supply and laying in trenches/pipe/on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS:7098 ( Pt I) with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed
Supply and laying in trenches/pipe/on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS:7098 ( Pt I) with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed
Supply and laying in trenches/pipe/on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS:7098 ( Pt I) with stranded aluminium conductor of size 400 sq mm 3.5 core complete all as specified and directed
Supply and fixing copper busbar chamber of capacity 200 Amps, 4 pole, 50 Hz, 415 volts, on wall /pole/panel with proper lugs having 4 Nos of copper bus bars complete all as specified and directed.
Supplying and fixing MCCB 160 Amps with sheet metal enclosure, 4 pole, 415 Volts, AC supply, having breaking capacity Icu =Ics = 100% ,25 KA with thermal and Magnetic release complete all as directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burned directly in ground ( earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel wire 4mm dia as earth lead Earth plate to pole test point including 15 mm GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 50 mm thick cover in 1:2:4 TYPE B-1 reinforced with 8mm dia CTD bars @8mm e/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burned directly in ground ( earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel Strip of size 32 x 6 mm as earth lead Earth plate to bldg test point including 40mm GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 50 mm thick cover in 1:2:4 TYPE B-1 reinforced with 8mm dia CTD bars @8mm e/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 .
Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31, 8.5 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply and Fix sheet moulding compound(SMC) junction box for and including three phase and neutral bus bar and MCB SPN 06 Amps, 250 Volts 50 Hz, 15 KA for control of sreet lights mounted on ploe with the provisions of cable entry and exit Make Sintex/hensel cat part No KF8350/ Siemens/L&T product code NO GSJB-2817 of size 280mmX170mmX130mm all as directed.
Supply and fixing 60 Watts street light LED fitting, new generation energy saving, environmental friendly long life, versatile pressure die cast aluminium, IP66 with 10KV surge protection road way,luminaire with high power LED as light source with warranty option of 5 years and suitable driversetc connecting with 4.0 sqmm multi strandard aluminium conductor PVC insulated twin core weather proof cable from fitting to junction box ( Appx 7.0 RM )and fixing to pole complete all as specified and directed.
HIGH MAST LIGHTING SYSTEM :-(i) Raising & lowering type 12.5 meter High Mast lighting system complete mast shall be in two section ,hot dip galvanised, inside and outside in single dip, suitable for wind velocity as per IS 875 part 3. There shall be only one longitudinal seem weld section and no circumferential weld. It shall also include accessories for high mast including head frame, 2-post suspension system with steel wire rope 6 mm dia (7/19 construction) double drum winch, Galvanised lantern carriage arrangement suitable for upto 8 luminaries symetrically,lighting finial & integral power tool for raising and lowering operation of the high mast. (i) Supply of foundation bolts manufactured from special steel alloy with nuts,washer,anchor plate & templates. (iv) Construction of suitable shallow foundation with 'M20' grade concrete for job the high mast considering the safe soil bearing capacity at site as 10T/sqmtr at 2 mtr depth including all materials & labour complete all as manufacturer specification/recommendation. (v) Errection of the high mast with the help of suitable equipment and including wiring of luminaries including flexible cable from control panel to lighting carriage all as per manufacturer specification complete. (vi) Supply and installation and commissioning of automatic control panel for switch 'ON'/'OFF' high mast light and raising/lowering of high mast. Control panel consisting of Astro type timer (having facility for operating partial load for full night and the balance load for part night to derive energy savings) and incoming/outgoing MCCBs, and contactors of suitable capacity including provision for by-pass arrangement. (vii) Wiring of luminaries with 2.5 sqmm multi core copper ERP insulated PCP sheathed (viii) Lightening arrestor with lightening conductor to be provided as per manufacturer specification. (ix) Twin dome Aviation obstruction light with suitable lamp to be provided as per manufacturer specification. (x) Testing & commissioning of High Mast System. Note :- (i) Earthing of high mast shall be measured and paid separately.
S & F of street light switch using timer for automatic switching of street light based on LUX level of natural light , The sensor along with suitable power contactor MCB support terminal shell be housed in enclosure made out of anti rust/ shock proof/ termite proof of Hensal Make/ confirming to IP66 suitable for 5 KW load single phase complet all as directed.
Supply and fixing on pole/wall flood light IP-66 LED light fitting of capacity 100 watt, 240 volt single phase 50 Hz consisting of aluminium pressure die cast housing with high purity PC freshnel diffuser with glass silicon gaskets complete assembly with LED accessories toughened prewired upto terminal block confirming to IS 10322 part 5/sec 1 : 1967 with inbuilt integrated electronic LED driver voltage surge protection not less than 3 KV, 2/3stage isolated driver, the LED lumen output colour temperature consisting complaint to LM 11000 K stranded system lumens of LED luminaries high lumen out put minimum 130 lm/watts , with suitable bracket, clamp, nut bolt washer, porcelean connecter, twin core pvc insulated aluminium cable 4.0 Sqmm , sheathed from fitting to junction box compete all as directed.
Supply and fix cable jointing kit suitable for 16 Sqmm to 35 Sqmm LT cable 1100 Volts grade for Indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of the following sizes complete all as directed
Supply and fix cable jointing kit suitable for 50 Sqmm to 95 Sqmm LT cable 1100 Volts grade for Indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of the following sizes complete all as directed
Supply and fix cable jointing kit suitable for 120 Sqmm to 240 Sqmm LT cable 1100 Volts grade for Indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of the following sizes complete all as directed
Supply and fix cable jointing kit suitable for 400 sqmm LT cable 1100 Volts grade for Indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of the following sizes complete all as directed
Dismantling of HT UG cable any size/type upto 120 sqmm complete all as directed
Dismantling of LT UG cable any size/type complete all as directed
Taking down unsv HT GOD complete all as directed.
Taking down unsv lightning Arrester complete all as directed.
Dismantling service wire/cable upto 16 sqmm size complete all as directed.
Taking down old street light fittings with bracket complete from pole any type/size complete all as directed..
Taking down old electric panel any type/size complete all as directed..
Air conditioning M&L for drilling suitable dia horiSupply and installing and testing and commissioning of hi wall split units indoor/outdoor AC of 1.5 TR capacity 230V,50 HZ SP complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating (2022) and EER 3.2.of capacity including provision of necessary clamps , wall mounting bracket, power and gas lines , gas charging,bolts,nuts for fixing of indoor/outdoor units making holes in the existing stone or brick wall and making good the distributed surfaces complete all as specified.NOTE: Rate quoted shall be inclusive of provision of PVC pipe protection ,drain pipe,contro cable with three core flexible 2.5 sqmm PVC insulated with multi stranded copper conductor, copper tubing for suction/discharge and additional gas charging if required other than factory charged gas including mounting outdoor on MS angle iron powder coated bracket of suitable size complete all as specified and directed.
Supplying,installing,testing and commissioning of automatic voltage stabilizer,Intellegent time delay system,High & low voltage cut-off-Unique cut-off system with latest IC technology built in thermal overload protection of 4KVA capacity, for an input voltage of 100V to 290V complete all as specified and directed.
Refrigeration, Water cooler & deep freezer Supply and Fix refrigerator electric driven (Single Phase), Capacity 210 ltr (not less than 195 Ltrs) ,BEE 5 Star Rated complete all as specified and directed.
Supply and Fix refrigerator electric driven (Single Phase), Capacity 310 ltr (not less than 290 Ltrs) ,BEE 5 Star Rated Complete all as specified and directed.
Supply and Fix Deep freezer glass top, single door, electric driven (Single Phase), Capacity 320 ltr ,BEE 5 Star Rated Complete all as specified and directed.
Supply and fix water cooler electric driven (single phase), BEE 5 Star Rated, having approx storage capacity of 80 litre fully stainless steel and nominal cooling capacity of 40 Litres per hour Complete all as specified and directed.
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).Plastic/PVC Body Complete all as specified and directed.
Supplying,installing,testing and commissioning of automatic voltage stabilizer,Intellegent time delay system,High & low voltage cut-off-Unique cut-off system with latest IC technology built in thermal overload protection of 1 KVA capacity, for an input voltage of 170V to 250V with accuracy of ± 2.5% all as specified and directed
Solar Water Heater Supply, installation , commissioning and testing at roof top of building 'Solar water heating system (Flat PlateCollector)' based on indirect type with electric backup heater as per manufacturer's recommednations of capacity 100 Ltr per day (at Temp 60 degree centigrade to 80 degree centigrade including suitable flat plate collectors having insulation of rock wool/mineral wool 50mm thickness bottom and 25mm thickness on sides with toughened tempered glass of 4mm thick and clading with aluminium sheet 26 SWG hot water storage tank of capacity 100 ltrs and of 20 guage thickness stainless steel plate (having insulation of rock wool ) mineral wool 100 mm thick & cladding with aluminium sheet 24 SWG) including staging for collector with necessary PCC work complete with electric power backup 3 KW capacity including all necessary electrical and water supply connection connection with GI tubing duly insulated Nitrile rubber 19 mm upto 7.5 mtr with control device and connection with water storage PVC tank on roof etc. complete all as specified & as directed.
S&F rotational moulded polyethylene water storage tank of 250 ltrs (Cylinderical vertical with closed top) hoisted and fixed in position with Ball brass valves, high pressure, with polythene float and flynut using MS Frame work duly supported with PCC blocks complete all as specified and directed
Akrati Technimont Limited
VEE SONS BUILDERS PVT LTD
JASPAL SINGH & CONST
M/S. JAI PRAKASH GUPTA
YAUK ENGINEERS
NITYA NAND AND SONS CONTRACTORS PVT LTD
M/S JAWAHAR LAL SHARMA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .