DIRECTOR ICAR NISA
NAMKUM RANCHI
SUPPLY AND INSTALLATION OF 18.0 HP AND 24.0 HP VRF AC (HEATING AND COOLING)
2026_DARE_898490_1
Admin.III/215/VRF AC/2025-26
Open Tender
Electrical Goods/Equipment
Supply
ICAR NISA NAMKUM RANCHI
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹80,000
2 Mar 2026
13 Feb 2026
25 Feb 2026
13 Feb 2026
24 Feb 2026
13 Feb 2026
OUTDOOR UNIT Variable Refrigerant Flow (VRF) air-cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Compressor(s) with R410A refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 52°C ambient temperature without tripping. The unit shall be suitable to work on 400V ± 10%, 3 Phase, 50Hz AC power supply. Make- Toshiba/Mitsubishi heavy duty/O-General/Carrier
Capacity - 18 HP (Heating + Cooling)
INDOOR UNIT- TYPE VRF indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%,50Hz,single phase AC supply, complete as required. 4-Way Cassette Ac Units (VRF)
Capacity - 2.56 TR
Wireless Remote
Y- joints (Multikits)
Refrigerant 'Y' Joint required for distribution of refrigerant in copper piping
COPPER PIPING Supply, installation, testing and commissioning of High Pressure Interconnecting Refrigerant pipe work for VRF System with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications, all piping inside the room shall be properly supported on GI Hangers and PVC sleeves shall be provided wherever pipe is crossing the wall. Food Grade Nitrogen is to be used while making brazing joints.
28.58 mm OD 19 mm thick insulation (Hard)
25.1 mm OD 19 mm thick insulation (Hard)
22.2 mm OD 19 mm thick insulation (Hard)
19.1 mm OD 19 mm thick insulation (Hard)
15.9 mm OD 19 mm thick insulation (Soft)
12.7 mm OD 13 mm thick insulation (Soft)
Communication cable Supply, installation, testing, termination and commissioning of control cum transimission wiring between indoor unit and outdoor unit in PVC Conduits. (1.5 SQ MM ) .
Supply, installation, testing, termination and commissioning of control cum transimission wiring between indoor unit and out door unit in PVC Conduits. (1.5 SQ MM ) .
Refrigerant Gas (Eco-friendly)
Refrigerant Gas Charging (R 410 A) as per liquid line length in line with Standard
Drain Pipe Supply, Installation, testing and commissioning of Hard CPVC Drain Pipe (Chlorinated polyvinyl chloride), Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 9 mm thick tubular nitrile insulation.
25 mm dia.
32 mm dia.
Item Wise BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
OUTDOOR UNIT Variable Refrigerant Flow (VRF) air-cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Compressor(s) with R410A refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 52°C ambient temperature without tripping. The unit shall be suitable to work on 400V ± 10%, 3 Phase, 50Hz AC power supply. Make- Toshiba/Mitsubishi heavy duty/O-General/Carrier
Capacity - 24 HP (Heating + Cooling)
INDOOR UNIT- TYPE VRF indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%,50Hz,single phase AC supply, complete as required. 4-Way Cassette Ac Units (VRF)
Capacity - 2.02TR
Wireless Remote
Y- joints (Multikits)
Refrigerant 'Y'Joint required for distribution of refrigerant in copper piping
COPPER PIPING Supply, installation, testing and commissioning of High Pressure Interconnecting Refrigerant pipe work for VRF System with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications, all piping inside the room shall be properly supported on GI Hangers and PVC sleeves shall be provided wherever pipe is crossing the wall. Food Grade Nitrogen is to be used while making brazing joints.
28.58 mm OD 19 mm thick insulation (Hard)
25.1 mm OD 19 mm thick insulation (Hard)
22.2 mm OD 19 mm thick insulation (Hard)
19.1 mm OD 19 mm thick insulation (Hard))
15.9 mm OD 19 mm thick insulation (Soft)
12.7 mm OD 13 mm thick insulation (Soft)
Communication cable Supply, installation, testing, termination and commissioning of control cum transimission wiring between indoor unit and outdoor unit in PVC Conduits. (1.5 SQ MM ) .
Supply, installation, testing, termination and commissioning of control cum transimission wiring between indoor unit and out door unit in PVC Conduits. (1.5 SQ MM ) .
Refrigerant Gas (Eco-friendly)
Refrigerant Gas Charging (R 410 A) as per liquid line length in line with Standard
Drain Pipe Supply, Installation, testing and commissioning of Hard CPVC Drain Pipe (Chlorinated polyvinyl chloride), Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 9 mm thick tubular nitrile insulation.
25 mm dia.
32 mm dia.
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
VRF2418.pdf
Tender Documents • 0.53 MB
BOQ_944404.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .