Loading…
Loading…
Tender Value
₹7.8 L
EMD Value
₹15,506
Closing Date
17 Sept 2026, 11:00 am2d left
DC(ELECT) FTR HQ BSF KASHMIR
FTR HQ BSF KASHMIR
As per BOQ
2026_BSF_925460_1
05/DC(E)/STC/KMR/2026-27
Open Tender
Electrical Works
Item Rate
45 days
STC KASHMIR
As per NIT
15 documents required · 15 mandatory
₹0
₹15,506
Yes
9 Sept 2026
9 Sept 2026
18 Sept 2026
9 Sept 2026
17 Sept 2026
9 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 100 A,30KA,FPMCCB | 2 | Each | - | - |
| 1.1 | 250 A,36KA,FPMCCB | 1 | Each | - | - |
| 1.2 | 400 A,50KA,FPMCCB | 2 | Each | - | - |
| 1.3 | 200 A,36KA,FPMCCB | 8 | Each | - | - |
| 2 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm (57mm) | 2 | Each | - | - |
| 3 | Providing and applying two or more coats of synthetic enamel paint of approved brand and manufacturer and of required shade on metal surfaces of electrical equipment (panels,Bus duct, Transformer etc.). The work includes the preparation of the surface by thoroughly cleaning oil, grease, dirt, and removing rust or scale using wire brushing or emery paper, complete as per standard specifications and the direction of the Engineer-in-Charge." | 86.86 | SQMM | - | - |
| 4 | Dehydration of transformer oil in the existing transformer at site , moisture removal from transformer oil,and maintain the viscosity of oil. Necessary pump and barrel driving execution of work shall be part of contractor if oil drain out necessary. Transformer oil dehydration is based on use of synthetic adsorbents ,additionally allows moisture to diffuse out of the paper into the oil. and submit the test report of transformers after conducting of its dielectric strength, viscosity, thermal conductivity, chemical stability ,BDV value etc as required. | 2,900 | LTR | - | - |
| 5 | Supplying and fixing joint box of size 450 X 450 X 250 MM having 250 Amps rating, 4 strips, long aluminum busbars mounted on suitable no of porcelain/SMC insulators, complete with all accessories making connections as required | 1 | Job | - | - |
| 6 | Supplying and replacement of complete Silica Gel approved make and required capacity for oil-filled electrical transformer. indicating-type (orange) silica gel with standered complies with IS: 3401-1992 complete as per standard specifications and direction of the Engineer-in-Charge." | 2 | Job | - | - |
| 7 | Comprehensive overhauling, servicing, and routine testing of 11 kV Indoor Vacuum Circuit Breaker (VCB) panel. The scope of work includes racking out the breaker, thorough cleaning using vacuum cleaners and CRC/contact cleaners, checking and lubricating the mechanical operating and tripping mechanism, tightening of all power and control electrical connections, and checking pole discrepancy and replacement of parts to ensure safety and optimal performance. The item includes electrical testing: Measurement of Insulation Resistance (Megger), Contact Resistance Measurement (CRM),Testing tripping and closing mechanisms complete as per standard specifications and the direction of the Engineer-in-Charge. | 4 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
BOQ_972523.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .