Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹5.4 L (4.76%)Admitted-Finance B2 16 SHREE BHAGAWATI NAGAR SUTARWADI ROAD PASHAN PUNE 411 021 | PUNE | MAHARASHTRA | 411021 | ₹1.2 Cr+₹5.4 L (4.76%) | L2 | Admitted-Finance |
| 3 | L3₹1.2 Cr+₹6.3 L (5.60%)Admitted-Finance | ₹1.2 Cr+₹6.3 L (5.60%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SREE LAKSHMI CONSTRUCTIONS L1 | Hi-Tech Infrastructure L3 | Maharashtra Enterprises L2 |
|---|---|---|---|---|---|---|
| 1.00SUBHEAD-I :EARTH WORK & EXCAVATION | ||||||
| 1.00Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | ||||||
| 1.00 | a) All kinds of soil | 229 | Cum | 180 ₹41,220 | 160 ₹36,640 Lowest | 300 ₹68,700 |
| 1.00 | b) Ordinary rock | 46 | Cum | 390 ₹17,940 Lowest | 420 ₹19,320 | 400 ₹18,400 |
| 1.00 | Supplying & Stacking Good Earth brought from outside MoD land | 119 | Cum | 590 ₹70,210 Lowest | 610 ₹72,590 | 900 ₹1,07,100 |
| 1.00 | Filling Available Excavated Earth (Excluding Rock) in trenches,Plinth sides of foundatios etc,in layers not exceeding 20cm in depth consolidating each diposited layer by ramming and watering,lead upto 50meter and lead upto 1.5meter | 160 | Cum | 80 ₹12,800 Lowest | 140 ₹22,400 | 250 ₹40,000 |
| 2.00SUBHEAD-II :ANTI TERMITE TREATMENT | ||||||
| 2.00 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1%concentration | 264 | Sqm | 200 ₹52,800 | 210 ₹55,440 | 150 ₹39,600 Lowest |
| 2.00 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration | 141 | RM | 85 ₹11,985 | 110 ₹15,510 | 35 ₹4,935 Lowest |
| 2.00 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% | 74 | Litres | 200 ₹14,800 | 210 ₹15,540 | 35 ₹2,590 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹2.3 L
Closing Date
13 Jul 2020, 2:00 pmClosed
V Ravisundara Kumar
CCE RnD Estates Chandrayangutta Hyderabad - 05
ADDITIONS/ ALTERATIONS TO CCE (RnD) ESTATES OFFICE AT HYDERABAD
2020_DRDO_565093_1
CCERnDEST/ENQ/CIV/HYD/03/20-21
Limited
Civil Works
Item Rate
365 days
Chandrayangutta
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Yes
CCE RnD Estates
₹2.3 L
Yes
10 Aug 2020
15 Jun 2020
14 Jul 2020
15 Jun 2020
13 Jul 2020
15 Jun 2020
Amount
SUBHEAD-I :EARTH WORK & EXCAVATION
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
a) All kinds of soil
b) Ordinary rock
Supplying & Stacking Good Earth brought from outside MoD land
Filling Available Excavated Earth (Excluding Rock) in trenches,Plinth sides of foundatios etc,in layers not exceeding 20cm in depth consolidating each diposited layer by ramming and watering,lead upto 50meter and lead upto 1.5meter
SUBHEAD-II :ANTI TERMITE TREATMENT
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1%concentration
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
SUBHEAD - III : PLAIN AND REINFORCED CEMENT CONCRETE WORK
Providing and laying in position Cement Concrete of specified grade including the cost of centering and shuttering - All work up to plinth level :
a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
b) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
Making Plinth Protection 50mm thick of Cement Concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Providing and laying in position machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
a)All works upto plinth level.
b)All works above plinth level upto floor V level.
Add / Deduct for using extra cement in the items of design mix over and above the specified cement content therein.
Supplying fabricating and fixing in position Reinforcement Steel for RCC work at all levels and locations including the cost of steel, straightening, cutting , bending , binding and placing in position etc.,as per drawings and specifications including the cost of binding wire labour etc., complete for reinforced concrete.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and Shuttering including strutting, propping etc and removal of form for :
a) Foundations, footings, bases of columns, etc. for mass concrete.
b) Columns, Pillars, Piers, Abutments, Posts and Struts.
c) Lintels, beams, plinth beams, girders, bressumers and cantilevers.
d) Suspended floors, roofs, landings, balconies and access platform.
e) Weather shade, Chajjas, corbels etc., including edges.
f) Stairs, (excluding landings) except spiral-staircases
g) Edges of slabs and breaks in floors and walls under 20 cm wide
SUBHEAD-IV : STONE & BRICK MASONRY
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand).
Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.
Cement mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :1:6 (1 cement : 4 coarse sand) : With Modular bricks
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level. Cement mortar 1:6 (1 cement :6 coarse sand) wit providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
SUBHEAD-V : JOINERY
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface with including screws etc. complect, as directed by Engineer-in-charge:
(Profile C) Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing 35mm thick Flush Door Shutters, with commercial ply with teak veneering on the both sides of approved make, core of block board construction with frame of first class hard wood including providing and fixing internal lipping with second class teak wood battens 25mm minimum depth on all edges of shutter, including ISI marked Stainless Steel butt hinges with necessary screws etc.,complete all as per drawings and as directed.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
i) 100mm long, 10mm dia
iii) 200mm long, 10mm dia
Al. Rubber Cleats :
i) 50mm size
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
i)Twin rubber stopper of approved make
Aluminum Aldrop 300mm long with 16mm dia rod of approved make
Providing and fixing of Godrej ELCO6, 6 level Mortice lock cum door handle with zinc alloy body with necessary screws etc., all complete as per direction of Engineer- in-charge. (Make Godrej or equivalent.)
Providing and fixing Heavy Duty aluminium alloy door closer extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.make-Godrej or equivalent.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856,complete as per direction of Engineer-in-charge.
Supplying, fabricating and fixing of M.S. Grills to windows & ventilators frames using MS flats, square rods all as per design etc., complete with a shop coat of primer.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
a) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) for fixed portion
b) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
i) Powder coated aluminium (minimum thickness of powder coating 50 micron
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
SUBHEAD-VI : FLOORING
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.
a) 40mm thick with 20mm nominal size stone aggregate
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.
a) 40mm thick with 20mm nominal size stone aggregate
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying double charged Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete..
Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles of size 300x400mm conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Granite stone flooring with 18 mm thick granite stone, as per sample of marble approved by Engineer-in-charge, over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with Rajnagar plain
Extra for pre finished nosing to treads of steps of granite stone.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-incharge and finished smooth.
a) Granite Stone of approved shade
Providing and laying 20mm thick porcelain paver tile of M/s Eurocon or approved equivalent make in floor at portico with water absorptions less than 3.5 % and flexural strength not less than 30 N/Sqm, in all colours and shades , laid over cement mortar 1:4 screed bed including pointing with white cement and matching pigments etc. complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
a) Granite of any colour and shade , Area of slab upto 0.50 sqm
SUBHEAD-VII : PLASTERING & SURFACE TREATMENT
6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.
12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge including Water proofing Compound.
White washing with lime to give an even shade New work (three or more coats) :complete all as directed by Engineer - in - Charge.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shadeNew work (two or more coats) over and including water thinnable priming coat with cement primer :complete all as directed by Engineer - in - Charge.
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm as directed by Engineer - in - Charge.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
SUBHEAD-VIII : FALSE CEILING
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction,
including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with including all neccssary fittings liks fastners,screw,nuts,bolts,tee rod ect complectly :(Make : Gproc , L Strong , Armstrong)
a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS Certification marks)(Make : Gproc , L Strong , Armstrong)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
SUBHEAD - IX : ROOF WORK
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge . With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying concrete on slabs and floors with P.C.C 1:2:4 (1 cement : 2 Coarse sand : 4 Aggregate 8 mm down) unserviceable material upto a lead of 500 m,Including necessary shuttering all complete as directed by Engineer-in-charge.
Providing and laying in situ seven course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
SUBHEAD- X: STRUCTURAL STEEL WORK
Providing and fixing stainless steel (Grade 304) Railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Structural steel work riveted, grantry,girders, gutter, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing bolts including nuts and washers complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing 2mm thick polycarbonate roof sheet, excluding the cost of purlins, rafters and trusses and inside of approved colour including cutting to size and shape wherever required all complete as directed by Engineer-in-charge.
SUBHEAD- XI: MISCELLANEOUS
RAIN WATER PIPE
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
a) Single socketed pipes of 150mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
a) Coupler
ii) 150mm Bend 87.5°
iii) 150mm Shoe (Plain)
Demolishing thatch roofing including bitumin mats, concrete works or brick bats. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. In cement mortar.
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge with nominal concrete 1:3:6 or richer mix(i/c equivalent design mix).
Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metrea leas as per direction of Engineer-in-charge with nominal concrete 1:3:6 or richer mix(i/c equivalent design mix).
Removing mortar from bricks and cleaning bricks including stacking within a leas of 50 m (stacks of cleaned bricks shall be measure) from brick work in cement mortar.
Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metrea leas as per direction of Engineer-in-charge in cement mortor
Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measurede) in cement mortar.
Dismantling doors, windows and clerestory windws (steel or wood) shutter including chowkats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3.0 Sqm and below.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead . For thickness of tiles 10mm to 25mm.
Dismantling C.I , GI or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead of 100mm dia pipe.
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer-in-charge.
Dismantling asbestos roofing sheets including ridges, hips, valleys and gutters etc and stacking the material within 50 metres
Dismantling GI pipes (external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge 15mm to 40mm
Credit Items
Credit for Asbestos sheet obtained from item no. 11.020 above
ii) Credit for Aluminium doors and windows obtained from item no.Item No 11.015
Credit for reinforcement steel items obtained from item no. 11.011 above
Credit for structural steel items obtained from item no. 11.016 above
Credit for CI, GI items obtained from item no. 11.018 above
Credit for GI pipes obtained from item no. 11.021 above
vii) Credit for CFL light fixtures of size 250mmx1200mm
viii) Credit for CFL Circular light fixtures of size 150mm Dia
ix) Credit of Copper wiring
SUBHEAD-XII : SANITARY SERVICES
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. Brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps of M/s jaquar make or of approved equivalent make as directed by engineer in charge (Basin - Hindware, Cat. no : Zen 10049 size 630x450mm & Pillar cock make - Jaquar, Cat. no: CON-021KN )
W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
a)W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing brass bib cock of approved quality :15 mm nominal bore of Make - Jaquar, Cat. no: CON-047KN. or such equivalent of Hindware & Paryware.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm
Providing and fixing CP brass Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms of Make - Jaquar, Cat. no: ALD-769L250x190. or such equivalent of Hindware & Paryware.
Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge
a) With granite stone of area less than 0.50 sqm.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing hand cleanser dispensers of 500ml with pink colour includung wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, (Make - KimberlyClark, Cat. no:01014. or equivalent )
Providing and fixing toilet paper holder:C.P. brass. (of Make - Jaquar, Cat. no: AHS-1553 or such equivalent of Hindware & Paryware.)
Providing and fixing towel ringSquare with Round Flange from wall face with concealed fittings arrangement of approved quality and colour. (Jaquar make cat. No. ACN-1121N or equivalent. )
Providing and fixing brass stop cock of approved quality : (Jaquar make cat. No.CON-053KN or equivalent. )
a) 15 mm nominal bore
Supply and fixing of 1.00 mts long easy flex tube with end nuts and hook and Health Faucet all complete. Hook to be fixed with CP brass with suitable counter sunk screws, all of approved make etc., complete Health Faucet (ABS Body) with 1m long easy flex tube in chromo finish and wall hooks Model No. ALD-CHR-585 of M/s Jaquar make or equivalent
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
a) 100 mm diameter S.W. pipe
b) 150 mm diameter S.W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
a) 100 mm diameter S.W. pipe
b) 150 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
a) 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
a) Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
SUBHEAD-XIII : WATER SUPPLY SERVICES
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
a) 15 mm nominal outer dia Pipes
c) 25 mm nominal outer dia Pipes
d) 32 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm dia nominal bore
32 mm dia nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
500 Litres Capacity
1000 Litres Capacity
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
SUBHEAD XIV : INTERNAL ELECTRIFICATION
Point Wiring for Light/ Fan/ exhaust fan with 2runs of 1100V grade 1.5 Sq.mm & 1 run of 1.5 Sq.mm FRLS , PVC insulated Copper wires, run in 25 mm dia 2 mm thick PVC conduits concealed in wall / on wall / concealed in ceiling / on surface conforming to IS 732 including all accessories such as junction boxes, conduit bends elbows and ceiling rose, anodised GI Switch box with modular switch and the box covered with front plate.
a) One light point controlled by one 6A switch
b) Two light point controlled by one 6A switch
c) One Light point controlled by two 6A switch.
e) One Exhaust fan point controlled by one 6A switch.
d) Supply and fixing of 6A, 5Pin Socket outlet with 6A switch in Lighting switch boards. (Dependent)
Supply and wiring for 6A Socket outlet with 2runs of 2.5sq.mm FRLS insulated multistranded copper wire and 1run of 1.5 sq.mm multistranded copper earth wire in and including heavy guage 25mm dia FRLS PVC conduit concealed in wall after necessary chase cutting with finishing/ceiling/below work stations along with required accessories, supply and fixing of 6A 5pin socket with 6A modular switch in anodised GI box and front plate complete with fixing accessories etc as required. (Independent)
Supply and wiring similar to item above but for Ceiling Fan point including GI box and controled by one 6A switch, 100W Step type Electronic regulator with Concealed MS fan hook box.
Supply and wiring similar to item above but for wall mounted Fan point including GI box and controled by one 6A switch,
Supply, Installation, Testing & Commissioning of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, low loss, ortho cyclically wound open construction copper ballast, ignitor & power factor improvement capacitor or Electronics Ballast etc are prewired up to the terminal block & mounted on a removable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting. with Lamp Control Gear & Fixing Accessories. All fixtures shall be white colour & supplied with white lamps. All the light fixtures will be finally approved by Architect / Consultant/ Department. Architect / Consultant / Department reserves the right to reject the fittings suggested by the contractor.
a) 36W LED light fixtures recess fitting ; (BZRSQL Gzi WH )
b) 36W LED light fixtures surface mounting : (BZSSQL 36W LED WH)
c) 18W LED light fixtures (BPSLR WH SQ)
d) 18 WLED light fixtures (BGSLO SLEU SURFACE 18 WATT WHRD)
e)20W LED light fixtures ;( BCLAB 20W )
Supply and fixing of 1400 mm sweep ceiling fan with standrad down rod , all accessories electrical connections including fixing materials required (without regulator)
Supply, Installation & Testing of following 900 RPM , 305 sweep exhaust fan suitable for single phase, 240V, AC supply complete with motor, MS louvers, mounting brackets, all accessories etc complete. 305 sweep
Supply and fixing of wall mounted 400mm Sweep Fan including fixing hardwares,
Supply and Wiring with the following size 1100V grade FRLS PVC insulated multistrand Copper conductor wires in suitable size 2 mm thick PVC conduit concealed in wall / on wall / concealed in ceiling / on ceiling including junction boxes, bends, elbows including with suitable lugs for connections
a) 2 runs of 2.5Sq.mm with 1run of 1.5 Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
b) 2 runs of 4Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
c) 3 runs of 6Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
SUB HEAD XV : AIR CONDITIONING
Supply, erection testing and commissioning of 1.5 TR inverter Air Conditioners with evaporating and condensing unit with MS stand and flexible copper cable of 3C x 4 Sqmm etc., complete. Make : Voltas/Carrier/Blue Star/ Daikin
supply, Erection,testing and commissioning of Drain piping with PVC pipe 25mm dia as per the specifications.
Supply, Installation, Testing and commissioning of following size hard copper piping for Condenser units with insulation of 6mm thick Nitrile Rubber pre formed sections including supporting fixtures and accessories etc., complete.
SUB HEAD XVI : POWER WIRING
Supply and fixing of modular type single phase 16A 6pin shuttered type Socket with switch with front plate and anodized GI box including all fixing accessories.
Supply, Installation, Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing/surface in wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB shall conform to IS :12640. All MCBs shall be 'C' Curve. DBs shall be provided along with required wire adopter boxes around the DB as required and dummys for spare ways in the DB (No claim shall be allowed for the same).
a) 6Way TPNMCBDB with 63A, 100mA 4Pole RCBO as incomer and 18 nos16A-25A SPMCBs as outgoings.
Supply, fixing, Testing and Comissioning of factory made 25A, 1Ph Metalclad socket with 25A SPMCB in MS box including all fixing accessories ( from RPDB) for AC Points
Supply and Wiring with the following size 1100V grade FRLS insulated multistranded Copper conductor wires in & including suitable size heavy guage FRLS PVC ISI mark conduit concealed in wall after necessary chase cutting with finishing/ Surface in wall / Ceiling including all accessories such as junction boxes, bends, elbows including and terminated with suitable lugs.
a) 2 runs of 4 Sq.mm wires with 1 run of 2.5 Sq.mm in 25mm dia FRLS PVC Conduit (for 16A Sockets)
b) 2 runs of 6 Sq.mm wires with 1 run of 4 Sq.mm in 25mm dia FRLS PVC Conduit (for 25A Sockets)
c) 4 runs of 10 Sq.mm wires with 2 runs of 6 Sq.mm in 32mm dia FRLS PVC Conduit.
Supply, Installation, Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing/surface in wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB shall conform to IS :12640. All MCBs shall be 'C' Curve. DBs shall be provided along with required wire adopter boxes around the DB as required and dummys for spare ways in the DB (No claim shall be allowed for the same).
a) 6Way TPNMCBDB with 63A, 100mA 4Pole RCBO as incomer and 18 nos16A-25A SPMCBs as outgoings. (PDBs)
MV Panel
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2.5mm thick CRCA sheet for main frame and 2mm thick partitions after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only.
MV Cable
Supply, laying, Testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 15mtr. interval and also at the turnings. The cable shall conform to IS 7098/Part II.
a) 3.5C X 120 Sq.mm
b) 3.5C X 50 Sq.mm
LT Cable Terminations
Providing Indoor ordinary end terminations for the cable specified below with compression type steel gland, Bi-metallic lugs using crimping tool,Insulation tape,Identification tags etc.,including end termination and Earthing of Gland.
a) 3.5C X 120 Sq.mm
b) 3.5C X 50 Sq.mm
Cable Tray
Supply and installation of cable tray of ladder type for armored cables or perforated GI cable tray for PVC conduits of the following sizes with all necessary supports and accessories etc., complete.
450x62.5mm Ladder Type Cable Tray
Earthing
Providing maintenance free Earth station with consisting of 40mm dia pipe standard length(as per equipment supplier)electrode capsule,filled with earth enhancing compound ,sealed at both ends and brazed lead for connection at one end.suitable for direct installation at side ,at a depth of 2.5mts.Earth enhancement compound up to a depth of 2mts around the electrode capsule ,brick chambers and CI cover complete.
Earthing with G.I. earth pipe 2.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Supply and laying of following size strips including all necessary inter connections between earth station and equipment. supports for strips as applicable .
a) 25 X 5mm Aluminium strip with DMC Insulated Supports
SUB HEAD XVII ; LAN / TELEPHONE
Supply and laying of 25mm dia. 2mm thick FRLS PVC conduit concealed in wall/ ceiling/floor including all accessories such as junction boxes, conduit bends, etc completed as required for Telephones etc
Supply and fixing of Telephone outlet (RJ11) with anodised GI box of with front plate and telephone socket
Supply and laying of 2 pair 0.5mm dia PVC insulated Copper conductor Telephone wire conforming to DOT specifications.
Supply and installation of 10 pair Telephone distribution box with back mount frame, krone connector, powder coated metal body with lock and key arrangement.
Supply and laying of following size 0.5mm dia Jelly filled copper conductor armoured Cables in ground at 600mm below ground level including excavation, and refilling of earth, laying of cables, providing protection with sand and bricks on top and sides and Telephone cable route markers at every 50mtrs interval complete as required and as directed by Engr-in-charge. The rate shall include cable end terminations also using kits cable glands cable lugs etc as required complete.The cable shall be as per the DOT specifications. (a.10 Pair)
SUBHEAD-XVIII : ROADS & STORM WATER DRAINS
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.
Maharashtra Enterprises
Hi-Tech Infrastructure
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Annexure_I.pdf
Additional Documents • 0.24 MB
Approved_Makes.pdf
Additional Documents • 0.32 MB
Tender_Enquiry.pdf
Tender Documents • 0.55 MB
BOQ_593129.xls
BOQ • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .