Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.1 LQualified Make: surya
Model: SURYA PROP PODDAR SONS GURUDWARA COMPLEX SEVOKE ROAD SEVOKE ROAD SILIGURI WEST BENGAL 734001 | JALPAIGURI | WEST BENGAL | 734001 | Make: surya
Model: SURYA | L1 | Qualified MSE, Category: General |
Tender Value
Refer Docs
EMD Value
₹13,656
Closing Date
18 Sept 2018, 4:00 pmClosed
Fluorescent lamps (Fluorescent tubular lamps)
Lamp starter (Ignitors - Starting device) for HPSV Lamps
Metal Halide lamps)
Light Emitting Diode LED Fixture- LED tube light
Lamp Ballast for HPSV Lamps
Lamp Ballast for HPSV Lamps Fluorescent Lamps (Fluorescent Tubular Lamps) ( 300 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Flourescent tubular lamps conforming to IS: 2418:1977 (Part1
2
3 and 4) with latest amendments Yes * ISI Marked Yes * If ISI market 'Yes' declare CM/L No 7083873 * Star rating level 3 Star 3 Star
5 Star Rated Wattage (in Watts) 36W 18W HL
36W HL
18W
36W Rated Colour 6500 K * Rated Luminous flux with colour rating 2425 for 36W with 6500 K 1250 for 18W HL with 6500 K
3100 fpor 36W HL with 6500 K
1015 for 18W with 6500 K
1/18 2425 for 36W with 6500 K CONSTRUCTIONAL Cap designation G-13 * Method of starting With starter * Cathode type Pre heated * Rated life of lamp Minimum 5000 hours * "The lamp dimensions shall he as speciiied on the individual lamp data sheet in IS : 2418 ( Part II )-1977 with latest amendments" Yes * Marking on the lamps as per IS:2418 :1977 (Part 1) with amendments and marking requirements as per energy star requirements Yes * WARRANTY Guaranteed period of replacement 1 year * REPORTS AND CERTIFICATION Flourescent tubular lamps shall pass and comply with all the acceptance test requirements as per Cl 6 1 2 of 2418 1977 (Part1) with latest amendments And seller shall furnish test reports on demand by buyer/consingee Yes * Flourescent tubular lamps shall pass and comply with all the routine test requirements as per Cl 6 1 3 of : 2418:1977 (Part1) with latest amendments And seller shall furnish test reports on demand by buyer/consingee Yes * For Energy Star Level Flourescent tubular lamps shall comply with Gazeettee notification No. S.0.178(E) dated 16th January
2009
S.0.179(E) dated 16th January
Yes * 2/18 No.2/11(5)/03-BEE.-1 dated 6th July
Amdt.
No.2/11(5)/03-BEE-1 dated 5th January
2010 Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to IS specifications as appliacable. Test reports shall furnish on demand by buyer/consignee Yes * Test Report Number CGCEL-0012 * Test Report Date 0/09/2017 * Name of Lab Crompton Greaves Consumer Electrical limited * Address of Lab vill-kural tal padra baroda * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mayur Gupta 444109
OFFICE OF THE CHIEF ENGINEER O&M
MSPGCL
THERMAL POWER STATION
PARASDEEP
Vidyut Nagar
Paras Dist. Akola Maharashtra- 444 109 300 15 Lamp Starter (Ignitors - Starting Device) For HPSV Lamps
Metal Halide Lamps) ( 500 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformity to Indian Standard As per IS:12449 Part 1 - 1988 and Part 2 - 1988 latest * ISI Marked Yes Yes 3/18 ISI marked if ''YES" declare BIS Licence number
If ''NO'' write NA NA * The lamp type for which the starting device (Ignitors) is suitable for Discharge Lamps (HPSV Lamps/Metal halide Lamps) * The lamp wattage for which the starting device (Ignitors) is suitable 400 W 400 W Starting devices (Ignitors) for discharge lamps for use on ac supplies up to 1000 V
50 Hz
which produces starting pulse not greater than 5 KV Yes * Starting device (Ignitors) shall pass the type test requirements as per Cl 7 (1) of IS:12449 Part 2 1988 latest Yes * CERTIFICATION Availability of Type Test Report from Central Government/NABL/ILAC accredited lab to prove conformity to specification Yes * All the test reports shall furnish to the buyer/consignee on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mayur Gupta 444109
Paras Dist. Akola Maharashtra- 444 109 500 15 Light Emitting Diode LED Fixture- LED Tube Light ( 200 ) Technical Specifications 4/18 * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Led tube light power rating corresponding Min Luminious flux 22 Watt/2200 lumen 22 Watt/2200 lumen Colour Temperature (K) 6500 2700
4000
5700
6500 Warranty for free replacement (Years) 2 years 2 years
3 years CONSTRUCTIONAL Type of Tube Light Cap G-13 Bi-pin * Ingress Protection in IP IP 20 * Lamp Shell material Polycarbonate Polycarbonate
Glass LED Fixture With Al back
front with polycarbonate/Acrylic diffuser more than 85%efficiency of lig With * Light Source SMD LED Chip * LED Make EDISSION
ORIENT * Length of tube light (Nominal) (in mm) 1220 * FUNCTIONAL LED lamp efficacy (Lm/W) 100 * Colour Rendering Inde (CRI) >/= 80 * Total Harmonics (%) </= 15% * LED Tubelight Life of 25000 hours predicted as per TM21 Report on Data obtained as per test conducted for 6000 hours as per LM80 Yes * Temperature Cycling test and supply voltage switching test (1) product shall be subjected to minus 10 degree C for 1 hour then switch to 50 degree C for 1 hour in total 5 cycles (2)30 sec ON and 30 sec Off At the end of test as per (1) and (2) no visual damage shall be Yes * 5/18 observed and light should alight for more than 15 min after the test Beam Angle (Degree) >/= 120 degree * Operating Voltage range (Volt) 100-300 * Driver Efficiency (%) more than 85% * Surge Voltage withstand (KV) 2.5 KV * LED Chip Efficacy (Lm/W) 130 * Rated Voltage for Performance and life (Volt) 220-240 * Lumen Maintenance at 25 deg;C after 6000 hrs (%) 80% * LED Chip Wattage (Individual) (Watt) 0
25 * Power Factor >/= 0.9 * CERTIFICATIONS BIS Registration certificate under (CRS) number and date 4514/475KMSYSKA * Certificare for Luminaire photometric data as per LM79 Yes * Certificate No and Date of Luminaire photometric data as per LM 79 report 2.2.2015 * Compulsory Registration and CRS of BIS for safety to IS 16102-I Yes * EMC Test Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mayur Gupta 444109
Paras Dist. Akola Maharashtra- 444 109 200 15 6/18 Lamp Ballast For HPSV Lamps ( 50 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Ballast for HPSV lamps (Excluding Tubular Flourescent Lamps) conforming to IS: 15882:2009 and all the ballasts specified in the standard shall meet the requirements of IS: 15885(Part-1):2011 latest and IS: 15885(Pa rt-2/Section-9): 2011 latest Yes * ISI Marked No Yes
No ISI marked if yes declare CM/L Number If 'No' write NA - * Ballast Wattage (in Watts) 400 W 400 W Operating Voltage 220 Volt -240 Volt * Supply frequency (in Hz) 50 Hz +/-5% * CONSTRUCTIONAL Ballast constructional requirements as per IS:15885 (Part 1) shall apply Yes * Winding material Copper wound * Supply current: At rated voltage
the supply current shall not differ by more than 10 percent from the value marked on the ballast when the latter is operated with a reference lamp Yes * Current wave form shall be as per Cl 9 of IS:15882:2009 latst Yes * Magnetic screening: The ballast shall be effectively screened against the influence of adjacent ferro- Yes * 7/18 magnetic materials as pe Cl 10 of IS:15882:2009 latest Ballast setting: Power delivered at rated voltage as per Cl. 15.1 of IS:15882:2009 latest (Not Less than 95% and not more than 105% of the reference ballast when operated at the objective lamp voltage as given in IS:9974(Part2) Yes * Short Circuit current between 92% and 106% of rated voltage as per Cl. 15.2 of IS:15882:2009 latest Yes * Open circuit voltage between 92% and 106% of its rated voltage as per Cl. 15.3 of IS:15882:2009 latest Yes * Insulation resistance as per Cl. 11 of IS:15885 Part 1 : 2011 latest >/=2 M Ohm * Electric strength as per Cl. 12 of IS:15885 Part 1 : 2011 latest Yes * Rated Maximum operating temperature of ballast (Tw) (Ref. Cl. B.9.2 of IS:15885 part 1:2011 latest) 105 deg C * Ballast shall pass the thermal endurance test for winding of ballast as per Cl.13 of IS:15885 Part 1 :2011 latest Yes * Ballast shall pass High voltage test 5 KV for 5 Seconds Yes * Watt Loss 38 Watts maximum for 400 W Ballast * Cold resistance at 20 deg. C (Tolerance: t+5%
10%) - must declare t+5% * Circuit power factor >/=0.85 * WARRANTY Guaranteed period of 1 Year * 8/18 replacement CERTIFICATION Marking: Apart from IS requirement each ballast shall be marked with serial number of ballast
Watt Loss
Tw details Yes * Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to IS specifications as appliacable Yes * Test Report Number - * Test Report Date - * Name of Test Lab - * Address of Test Lab - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mayur Gupta 444109
Paras Dist. Akola Maharashtra- 444 109 50 15 Lamp Ballast For HPSV Lamps ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Ballast for HPSV lamps (Excluding Tubular Flourescent Lamps) conforming to IS: 15882:2009 and all the ballasts specified in the standard shall meet the requirements of IS: 15885(Part-1):2011 latest and IS: 15885(Pa rt-2/Section-9): 2011 Yes * 9/18 latest ISI Marked Yes Yes
No ISI marked if yes declare CM/L Number If 'No' write NA - * Ballast Wattage (in Watts) 150 W 150 W Operating Voltage 220 Volt -240 Volt * Supply frequency (in Hz) 50 Hz +/-5% * CONSTRUCTIONAL Ballast constructional requirements as per IS:15885 (Part 1) shall apply Yes * Winding material Copper wound * Supply current: At rated voltage
the supply current shall not differ by more than 10 percent from the value marked on the ballast when the latter is operated with a reference lamp Yes * Current wave form shall be as per Cl 9 of IS:15882:2009 latst Yes * Magnetic screening: The ballast shall be effectively screened against the influence of adjacent ferro- magnetic materials as pe Cl 10 of IS:15882:2009 latest Yes * Ballast setting: Power delivered at rated voltage as per Cl. 15.1 of IS:15882:2009 latest (Not Less than 95% and not more than 105% of the reference ballast when operated at the objective lamp voltage as given in IS:9974(Part2) Yes * Short Circuit current between 92% and 106% of rated voltage as per Cl. 15.2 of IS:15882:2009 latest Yes * 10/18 Open circuit voltage between 92% and 106% of its rated voltage as per Cl. 15.3 of IS:15882:2009 latest Yes * Insulation resistance as per Cl. 11 of IS:15885 Part 1 : 2011 latest >/=2 M Ohm * Electric strength as per Cl. 12 of IS:15885 Part 1 : 2011 latest Yes * Rated Maximum operating temperature of ballast (Tw) (Ref. Cl. B.9.2 of IS:15885 part 1:2011 latest) 105 deg C * Ballast shall pass the thermal endurance test for winding of ballast as per Cl.13 of IS:15885 Part 1 :2011 latest Yes * Ballast shall pass High voltage test 5 KV for 5 Seconds Yes * Watt Loss 19 Watts maximum for 150 W Ballast * Cold resistance at 20 deg. C (Tolerance: t+5%
10%) - must declare Tolerance : t+ 5%
10% * Circuit power factor >/=0.85 * WARRANTY Guaranteed period of replacement 1 Year * CERTIFICATION Marking: Apart from IS requirement each ballast shall be marked with serial number of ballast
Tw details Yes * Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to IS specifications as appliacable Yes * Test Report Number - * Test Report Date - * 11/18 Name of Test Lab - * Address of Test Lab - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mayur Gupta 444109
Paras Dist. Akola Maharashtra- 444 109 100 15 Lamp Ballast For HPSV Lamps ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Ballast for HPSV lamps (Excluding Tubular Flourescent Lamps) conforming to IS: 15882:2009 and all the ballasts specified in the standard shall meet the requirements of IS: 15885(Part-1):2011 latest and IS: 15885(Pa rt-2/Section-9): 2011 latest Yes * ISI Marked Yes Yes ISI marked if yes declare CM/L Number If 'No' write NA - * Ballast Wattage (in Watts) 70 W 70 W Operating Voltage 220 Volt -240 Volt * Supply frequency (in Hz) 50 Hz +/-5% * CONSTRUCTIONAL Ballast constructional requirements as per IS:15885 (Part 1) shall apply Yes * Winding material Copper wound * 12/18 Supply current: At rated voltage
the supply current shall not differ by more than 10 percent from the value marked on the ballast when the latter is operated with a reference lamp Yes * Current wave form shall be as per Cl 9 of IS:15882:2009 latst Yes * Magnetic screening: The ballast shall be effectively screened against the influence of adjacent ferro- magnetic materials as pe Cl 10 of IS:15882:2009 latest Yes * Ballast setting: Power delivered at rated voltage as per Cl. 15.1 of IS:15882:2009 latest (Not Less than 95% and not more than 105% of the reference ballast when operated at the objective lamp voltage as given in IS:9974(Part2) Yes * Short Circuit current between 92% and 106% of rated voltage as per Cl. 15.2 of IS:15882:2009 latest Yes * Open circuit voltage between 92% and 106% of its rated voltage as per Cl. 15.3 of IS:15882:2009 latest Yes * Insulation resistance as per Cl. 11 of IS:15885 Part 1 : 2011 latest >/=2 M Ohm * Electric strength as per Cl. 12 of IS:15885 Part 1 : 2011 latest Yes * Rated Maximum operating temperature of ballast (Tw) (Ref. Cl. B.9.2 of IS:15885 part 1:2011 latest) 105 deg C * 13/18 Ballast shall pass the thermal endurance test for winding of ballast as per Cl.13 of IS:15885 Part 1 :2011 latest Yes * Ballast shall pass High voltage test 5 KV for 5 Seconds Yes * Watt Loss 15 Watts maximum for 70 W Ballast * Cold resistance at 20 deg. C (Tolerance: t+5%
10%) - must declare +5% * Circuit power factor >/=0.85 * WARRANTY Guaranteed period of replacement 1 Year * CERTIFICATION Marking: Apart from IS requirement each ballast shall be marked with serial number of ballast
Paras Dist. Akola Maharashtra- 444 109 100 15 Lamp Ballast For HPSV Lamps ( 75 ) 14/18 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Ballast for HPSV lamps (Excluding Tubular Flourescent Lamps) conforming to IS: 15882:2009 and all the ballasts specified in the standard shall meet the requirements of IS: 15885(Part-1):2011 latest and IS: 15885(Pa rt-2/Section-9): 2011 latest Yes * ISI Marked Yes Yes ISI marked if yes declare CM/L Number If 'No' write NA - * Ballast Wattage (in Watts) 150 W 150 W Operating Voltage 220 Volt -240 Volt * Supply frequency (in Hz) 50 Hz +/-5% * CONSTRUCTIONAL Ballast constructional requirements as per IS:15885 (Part 1) shall apply Yes * Winding material Copper wound * Supply current: At rated voltage
the supply current shall not differ by more than 10 percent from the value marked on the ballast when the latter is operated with a reference lamp Yes * Current wave form shall be as per Cl 9 of IS:15882:2009 latst Yes * Magnetic screening: The ballast shall be effectively screened against the influence of adjacent ferro- magnetic materials as pe Cl 10 of Yes * 15/18 IS:15882:2009 latest Ballast setting: Power delivered at rated voltage as per Cl. 15.1 of IS:15882:2009 latest (Not Less than 95% and not more than 105% of the reference ballast when operated at the objective lamp voltage as given in IS:9974(Part2) Yes * Short Circuit current between 92% and 106% of rated voltage as per Cl. 15.2 of IS:15882:2009 latest Yes * Open circuit voltage between 92% and 106% of its rated voltage as per Cl. 15.3 of IS:15882:2009 latest Yes * Insulation resistance as per Cl. 11 of IS:15885 Part 1 : 2011 latest >/=2 M Ohm * Electric strength as per Cl. 12 of IS:15885 Part 1 : 2011 latest Yes * Rated Maximum operating temperature of ballast (Tw) (Ref. Cl. B.9.2 of IS:15885 part 1:2011 latest) 105 deg C * Ballast shall pass the thermal endurance test for winding of ballast as per Cl.13 of IS:15885 Part 1 :2011 latest Yes * Ballast shall pass High voltage test 5 KV for 5 Seconds Yes * Watt Loss 19 Watts maximum for 150 W Ballast * Cold resistance at 20 deg. C (Tolerance: t+5%
10%) - must declare 5 * Circuit power factor >/=0.85 * WARRANTY Guaranteed period of replacement 1 Year * 16/18 CERTIFICATION Marking: Apart from IS requirement each ballast shall be marked with serial number of ballast
Paras Dist. Akola Maharashtra- 444 109 75 15
581708
GEM/2018/B/82505
Fluorescent lamps (Fluorescent tubular lamps),Lamp starter (Ignitors - Starting device) for HPSV
15 days
Maharashtra; Akola
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Fluorescent lamps (Fluorescent tubular lamps) | - | - | - |
| Lamp starter (Ignitors - Starting device) for HPSV Lamps | - | - | - |
| Metal Halide lamps) | - | - | - |
| Light Emitting Diode LED Fixture- LED tube light | - | - | - |
| Lamp Ballast for HPSV Lamps | - | - | - |
| Lamp Ballast for HPSV Lamps Fluorescent Lamps (Fluorescent Tubular Lamps) ( 300 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Flourescent tubular lamps conforming to IS: 2418:1977 (Part1 | - | - | - |
| 2 | - | - | - |
| 3 and 4) with latest amendments Yes * ISI Marked Yes * If ISI market 'Yes' declare CM/L No 7083873 * Star rating level 3 Star 3 Star | - | - | - |
| 5 Star Rated Wattage (in Watts) 36W 18W HL | - | - | - |
| 36W HL | - | - | - |
| 18W | - | - | - |
| 36W Rated Colour 6500 K * Rated Luminous flux with colour rating 2425 for 36W with 6500 K 1250 for 18W HL with 6500 K | - | - | - |
| 3100 fpor 36W HL with 6500 K | - | - | - |
| 1015 for 18W with 6500 K | - | - | - |
| 1/18 2425 for 36W with 6500 K CONSTRUCTIONAL Cap designation G-13 * Method of starting With starter * Cathode type Pre heated * Rated life of lamp Minimum 5000 hours * "The lamp dimensions shall he as speciiied on the individual lamp data sheet in IS : 2418 ( Part II )-1977 with latest amendments" Yes * Marking on the lamps as per IS:2418 :1977 (Part 1) with amendments and marking requirements as per energy star requirements Yes * WARRANTY Guaranteed period of replacement 1 year * REPORTS AND CERTIFICATION Flourescent tubular lamps shall pass and comply with all the acceptance test requirements as per Cl 6 1 2 of 2418 1977 (Part1) with latest amendments And seller shall furnish test reports on demand by buyer/consingee Yes * Flourescent tubular lamps shall pass and comply with all the routine test requirements as per Cl 6 1 3 of : 2418:1977 (Part1) with latest amendments And seller shall furnish test reports on demand by buyer/consingee Yes * For Energy Star Level Flourescent tubular lamps shall comply with Gazeettee notification No. S.0.178(E) dated 16th January | - | - | - |
| 2009 | - | - | - |
| S.0.179(E) dated 16th January | - | - | - |
| Yes * 2/18 No.2/11(5)/03-BEE.-1 dated 6th July | - | - | - |
| Amdt. | - | - | - |
| No.2/11(5)/03-BEE-1 dated 5th January | - | - | - |
| 2010 Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to IS specifications as appliacable. Test reports shall furnish on demand by buyer/consignee Yes * Test Report Number CGCEL-0012 * Test Report Date 0/09/2017 * Name of Lab Crompton Greaves Consumer Electrical limited * Address of Lab vill-kural tal padra baroda * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mayur Gupta 444109 | - | - | - |
| OFFICE OF THE CHIEF ENGINEER O&M | - | - | - |
| MSPGCL | - | - | - |
| THERMAL POWER STATION | - | - | - |
| PARASDEEP | - | - | - |
| Vidyut Nagar | - | - | - |
| Paras Dist. Akola Maharashtra- 444 109 300 15 Lamp Starter (Ignitors - Starting Device) For HPSV Lamps | - | - | - |
| Metal Halide Lamps) ( 500 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformity to Indian Standard As per IS:12449 Part 1 - 1988 and Part 2 - 1988 latest * ISI Marked Yes Yes 3/18 ISI marked if ''YES" declare BIS Licence number | - | - | - |
| If ''NO'' write NA NA * The lamp type for which the starting device (Ignitors) is suitable for Discharge Lamps (HPSV Lamps/Metal halide Lamps) * The lamp wattage for which the starting device (Ignitors) is suitable 400 W 400 W Starting devices (Ignitors) for discharge lamps for use on ac supplies up to 1000 V | - | - | - |
| 50 Hz | - | - | - |
| which produces starting pulse not greater than 5 KV Yes * Starting device (Ignitors) shall pass the type test requirements as per Cl 7 (1) of IS:12449 Part 2 1988 latest Yes * CERTIFICATION Availability of Type Test Report from Central Government/NABL/ILAC accredited lab to prove conformity to specification Yes * All the test reports shall furnish to the buyer/consignee on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mayur Gupta 444109 | - | - | - |
| Paras Dist. Akola Maharashtra- 444 109 500 15 Light Emitting Diode LED Fixture- LED Tube Light ( 200 ) Technical Specifications 4/18 * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Led tube light power rating corresponding Min Luminious flux 22 Watt/2200 lumen 22 Watt/2200 lumen Colour Temperature (K) 6500 2700 | - | - | - |
| 4000 | - | - | - |
| 5700 | - | - | - |
| 6500 Warranty for free replacement (Years) 2 years 2 years | - | - | - |
| 3 years CONSTRUCTIONAL Type of Tube Light Cap G-13 Bi-pin * Ingress Protection in IP IP 20 * Lamp Shell material Polycarbonate Polycarbonate | - | - | - |
| Glass LED Fixture With Al back | - | - | - |
| front with polycarbonate/Acrylic diffuser more than 85%efficiency of lig With * Light Source SMD LED Chip * LED Make EDISSION | - | - | - |
| ORIENT * Length of tube light (Nominal) (in mm) 1220 * FUNCTIONAL LED lamp efficacy (Lm/W) 100 * Colour Rendering Inde (CRI) >/= 80 * Total Harmonics (%) </= 15% * LED Tubelight Life of 25000 hours predicted as per TM21 Report on Data obtained as per test conducted for 6000 hours as per LM80 Yes * Temperature Cycling test and supply voltage switching test (1) product shall be subjected to minus 10 degree C for 1 hour then switch to 50 degree C for 1 hour in total 5 cycles (2)30 sec ON and 30 sec Off At the end of test as per (1) and (2) no visual damage shall be Yes * 5/18 observed and light should alight for more than 15 min after the test Beam Angle (Degree) >/= 120 degree * Operating Voltage range (Volt) 100-300 * Driver Efficiency (%) more than 85% * Surge Voltage withstand (KV) 2.5 KV * LED Chip Efficacy (Lm/W) 130 * Rated Voltage for Performance and life (Volt) 220-240 * Lumen Maintenance at 25 deg;C after 6000 hrs (%) 80% * LED Chip Wattage (Individual) (Watt) 0 | - | - | - |
| 25 * Power Factor >/= 0.9 * CERTIFICATIONS BIS Registration certificate under (CRS) number and date 4514/475KMSYSKA * Certificare for Luminaire photometric data as per LM79 Yes * Certificate No and Date of Luminaire photometric data as per LM 79 report 2.2.2015 * Compulsory Registration and CRS of BIS for safety to IS 16102-I Yes * EMC Test Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mayur Gupta 444109 | - | - | - |
| Paras Dist. Akola Maharashtra- 444 109 200 15 6/18 Lamp Ballast For HPSV Lamps ( 50 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Ballast for HPSV lamps (Excluding Tubular Flourescent Lamps) conforming to IS: 15882:2009 and all the ballasts specified in the standard shall meet the requirements of IS: 15885(Part-1):2011 latest and IS: 15885(Pa rt-2/Section-9): 2011 latest Yes * ISI Marked No Yes | - | - | - |
| No ISI marked if yes declare CM/L Number If 'No' write NA - * Ballast Wattage (in Watts) 400 W 400 W Operating Voltage 220 Volt -240 Volt * Supply frequency (in Hz) 50 Hz +/-5% * CONSTRUCTIONAL Ballast constructional requirements as per IS:15885 (Part 1) shall apply Yes * Winding material Copper wound * Supply current: At rated voltage | - | - | - |
| the supply current shall not differ by more than 10 percent from the value marked on the ballast when the latter is operated with a reference lamp Yes * Current wave form shall be as per Cl 9 of IS:15882:2009 latst Yes * Magnetic screening: The ballast shall be effectively screened against the influence of adjacent ferro- Yes * 7/18 magnetic materials as pe Cl 10 of IS:15882:2009 latest Ballast setting: Power delivered at rated voltage as per Cl. 15.1 of IS:15882:2009 latest (Not Less than 95% and not more than 105% of the reference ballast when operated at the objective lamp voltage as given in IS:9974(Part2) Yes * Short Circuit current between 92% and 106% of rated voltage as per Cl. 15.2 of IS:15882:2009 latest Yes * Open circuit voltage between 92% and 106% of its rated voltage as per Cl. 15.3 of IS:15882:2009 latest Yes * Insulation resistance as per Cl. 11 of IS:15885 Part 1 : 2011 latest >/=2 M Ohm * Electric strength as per Cl. 12 of IS:15885 Part 1 : 2011 latest Yes * Rated Maximum operating temperature of ballast (Tw) (Ref. Cl. B.9.2 of IS:15885 part 1:2011 latest) 105 deg C * Ballast shall pass the thermal endurance test for winding of ballast as per Cl.13 of IS:15885 Part 1 :2011 latest Yes * Ballast shall pass High voltage test 5 KV for 5 Seconds Yes * Watt Loss 38 Watts maximum for 400 W Ballast * Cold resistance at 20 deg. C (Tolerance: t+5% | - | - | - |
| 10%) - must declare t+5% * Circuit power factor >/=0.85 * WARRANTY Guaranteed period of 1 Year * 8/18 replacement CERTIFICATION Marking: Apart from IS requirement each ballast shall be marked with serial number of ballast | - | - | - |
| Watt Loss | - | - | - |
| Tw details Yes * Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to IS specifications as appliacable Yes * Test Report Number - * Test Report Date - * Name of Test Lab - * Address of Test Lab - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mayur Gupta 444109 | - | - | - |
| Paras Dist. Akola Maharashtra- 444 109 50 15 Lamp Ballast For HPSV Lamps ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Ballast for HPSV lamps (Excluding Tubular Flourescent Lamps) conforming to IS: 15882:2009 and all the ballasts specified in the standard shall meet the requirements of IS: 15885(Part-1):2011 latest and IS: 15885(Pa rt-2/Section-9): 2011 Yes * 9/18 latest ISI Marked Yes Yes | - | - | - |
| No ISI marked if yes declare CM/L Number If 'No' write NA - * Ballast Wattage (in Watts) 150 W 150 W Operating Voltage 220 Volt -240 Volt * Supply frequency (in Hz) 50 Hz +/-5% * CONSTRUCTIONAL Ballast constructional requirements as per IS:15885 (Part 1) shall apply Yes * Winding material Copper wound * Supply current: At rated voltage | - | - | - |
| the supply current shall not differ by more than 10 percent from the value marked on the ballast when the latter is operated with a reference lamp Yes * Current wave form shall be as per Cl 9 of IS:15882:2009 latst Yes * Magnetic screening: The ballast shall be effectively screened against the influence of adjacent ferro- magnetic materials as pe Cl 10 of IS:15882:2009 latest Yes * Ballast setting: Power delivered at rated voltage as per Cl. 15.1 of IS:15882:2009 latest (Not Less than 95% and not more than 105% of the reference ballast when operated at the objective lamp voltage as given in IS:9974(Part2) Yes * Short Circuit current between 92% and 106% of rated voltage as per Cl. 15.2 of IS:15882:2009 latest Yes * 10/18 Open circuit voltage between 92% and 106% of its rated voltage as per Cl. 15.3 of IS:15882:2009 latest Yes * Insulation resistance as per Cl. 11 of IS:15885 Part 1 : 2011 latest >/=2 M Ohm * Electric strength as per Cl. 12 of IS:15885 Part 1 : 2011 latest Yes * Rated Maximum operating temperature of ballast (Tw) (Ref. Cl. B.9.2 of IS:15885 part 1:2011 latest) 105 deg C * Ballast shall pass the thermal endurance test for winding of ballast as per Cl.13 of IS:15885 Part 1 :2011 latest Yes * Ballast shall pass High voltage test 5 KV for 5 Seconds Yes * Watt Loss 19 Watts maximum for 150 W Ballast * Cold resistance at 20 deg. C (Tolerance: t+5% | - | - | - |
| 10%) - must declare Tolerance : t+ 5% | - | - | - |
| 10% * Circuit power factor >/=0.85 * WARRANTY Guaranteed period of replacement 1 Year * CERTIFICATION Marking: Apart from IS requirement each ballast shall be marked with serial number of ballast | - | - | - |
| Tw details Yes * Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to IS specifications as appliacable Yes * Test Report Number - * Test Report Date - * 11/18 Name of Test Lab - * Address of Test Lab - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mayur Gupta 444109 | - | - | - |
| Paras Dist. Akola Maharashtra- 444 109 100 15 Lamp Ballast For HPSV Lamps ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Ballast for HPSV lamps (Excluding Tubular Flourescent Lamps) conforming to IS: 15882:2009 and all the ballasts specified in the standard shall meet the requirements of IS: 15885(Part-1):2011 latest and IS: 15885(Pa rt-2/Section-9): 2011 latest Yes * ISI Marked Yes Yes ISI marked if yes declare CM/L Number If 'No' write NA - * Ballast Wattage (in Watts) 70 W 70 W Operating Voltage 220 Volt -240 Volt * Supply frequency (in Hz) 50 Hz +/-5% * CONSTRUCTIONAL Ballast constructional requirements as per IS:15885 (Part 1) shall apply Yes * Winding material Copper wound * 12/18 Supply current: At rated voltage | - | - | - |
| the supply current shall not differ by more than 10 percent from the value marked on the ballast when the latter is operated with a reference lamp Yes * Current wave form shall be as per Cl 9 of IS:15882:2009 latst Yes * Magnetic screening: The ballast shall be effectively screened against the influence of adjacent ferro- magnetic materials as pe Cl 10 of IS:15882:2009 latest Yes * Ballast setting: Power delivered at rated voltage as per Cl. 15.1 of IS:15882:2009 latest (Not Less than 95% and not more than 105% of the reference ballast when operated at the objective lamp voltage as given in IS:9974(Part2) Yes * Short Circuit current between 92% and 106% of rated voltage as per Cl. 15.2 of IS:15882:2009 latest Yes * Open circuit voltage between 92% and 106% of its rated voltage as per Cl. 15.3 of IS:15882:2009 latest Yes * Insulation resistance as per Cl. 11 of IS:15885 Part 1 : 2011 latest >/=2 M Ohm * Electric strength as per Cl. 12 of IS:15885 Part 1 : 2011 latest Yes * Rated Maximum operating temperature of ballast (Tw) (Ref. Cl. B.9.2 of IS:15885 part 1:2011 latest) 105 deg C * 13/18 Ballast shall pass the thermal endurance test for winding of ballast as per Cl.13 of IS:15885 Part 1 :2011 latest Yes * Ballast shall pass High voltage test 5 KV for 5 Seconds Yes * Watt Loss 15 Watts maximum for 70 W Ballast * Cold resistance at 20 deg. C (Tolerance: t+5% | - | - | - |
| 10%) - must declare +5% * Circuit power factor >/=0.85 * WARRANTY Guaranteed period of replacement 1 Year * CERTIFICATION Marking: Apart from IS requirement each ballast shall be marked with serial number of ballast | - | - | - |
| Paras Dist. Akola Maharashtra- 444 109 100 15 Lamp Ballast For HPSV Lamps ( 75 ) 14/18 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Ballast for HPSV lamps (Excluding Tubular Flourescent Lamps) conforming to IS: 15882:2009 and all the ballasts specified in the standard shall meet the requirements of IS: 15885(Part-1):2011 latest and IS: 15885(Pa rt-2/Section-9): 2011 latest Yes * ISI Marked Yes Yes ISI marked if yes declare CM/L Number If 'No' write NA - * Ballast Wattage (in Watts) 150 W 150 W Operating Voltage 220 Volt -240 Volt * Supply frequency (in Hz) 50 Hz +/-5% * CONSTRUCTIONAL Ballast constructional requirements as per IS:15885 (Part 1) shall apply Yes * Winding material Copper wound * Supply current: At rated voltage | - | - | - |
| the supply current shall not differ by more than 10 percent from the value marked on the ballast when the latter is operated with a reference lamp Yes * Current wave form shall be as per Cl 9 of IS:15882:2009 latst Yes * Magnetic screening: The ballast shall be effectively screened against the influence of adjacent ferro- magnetic materials as pe Cl 10 of Yes * 15/18 IS:15882:2009 latest Ballast setting: Power delivered at rated voltage as per Cl. 15.1 of IS:15882:2009 latest (Not Less than 95% and not more than 105% of the reference ballast when operated at the objective lamp voltage as given in IS:9974(Part2) Yes * Short Circuit current between 92% and 106% of rated voltage as per Cl. 15.2 of IS:15882:2009 latest Yes * Open circuit voltage between 92% and 106% of its rated voltage as per Cl. 15.3 of IS:15882:2009 latest Yes * Insulation resistance as per Cl. 11 of IS:15885 Part 1 : 2011 latest >/=2 M Ohm * Electric strength as per Cl. 12 of IS:15885 Part 1 : 2011 latest Yes * Rated Maximum operating temperature of ballast (Tw) (Ref. Cl. B.9.2 of IS:15885 part 1:2011 latest) 105 deg C * Ballast shall pass the thermal endurance test for winding of ballast as per Cl.13 of IS:15885 Part 1 :2011 latest Yes * Ballast shall pass High voltage test 5 KV for 5 Seconds Yes * Watt Loss 19 Watts maximum for 150 W Ballast * Cold resistance at 20 deg. C (Tolerance: t+5% | - | - | - |
| 10%) - must declare 5 * Circuit power factor >/=0.85 * WARRANTY Guaranteed period of replacement 1 Year * 16/18 CERTIFICATION Marking: Apart from IS requirement each ballast shall be marked with serial number of ballast | - | - | - |
| Paras Dist. Akola Maharashtra- 444 109 75 15 | - | - | - |
₹13,656
18 Sept 2018
7 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_581708.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .