Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-Finance | L1 | Accepted-Finance BEING L1 | |
| 2 | L2₹1.2 L+₹1,467.90 (1.22%)Accepted-Finance | L2 | Accepted-Finance NOT BEING L1 | |
| 3 | L3₹1.3 L+₹6,145 (5.12%)Accepted-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L3 | Accepted-Finance NOT BEING L1 |
Tender Value
Refer Docs
Closing Date
28 Mar 2022, 6:00 pmClosed
MENUGA MANJUNATH
GE (North) Udhampur JNE Complex, T Morh Udhampur-182101
JOB ORDER FOR REPAIR AND MAINT OF STP AT 31 RR UNDER GE (NORTH) UDHAMPUR
2022_MES_513930_1
3016/Q/18/E3
Open Tender
Miscellaneous Works
Works
90 days
UDHAMPUR
As per tender documents
4 documents required · 4 mandatory
₹0
Exempted
16 Apr 2022
16 Mar 2022
29 Mar 2022
16 Mar 2022
28 Mar 2022
16 Mar 2022
Amount
Excavation in trenches in any type of soil and exc 1.5 M deep and not exceeding 1.5 mtr wide for laying of under ground cable, electric pole and getting out complete all as directed.
Returning filling in including spreading leveling watering and well ramming 25cm in thickness in any type of soil
Removing excavated material and exc 50 mtr and depositing where directed at a level and exc 1.5 mtr above the starting point.
M&L for dry sand cushioning to under ground cables provided with a layer of sand 8cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed.
Supply and lay brick class B covering as mechanical protection to cable with well burnt all as specified.
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 16 sqmm 4 core in trenches / floor / pole / GI pipe complete including cutting of bituminous road / chasing to any surface and making good to the disturbed surface to match the existing.
Disconnecting the defective / burnt electric induction motor & dismantling from the foundation, shifting to workshop opening checking for defects Varnishing, drying, greasing, insulating the terminals connections etc. incl carrying out minor repair (winding will be paid separately).
Rewinding the electric induction motor of capacity 1HP suitable to run on 415V AC, 50 Hz supply with copper enameled copper wire of suitable gauge / size including proper insulation and making connection to the terminal plate complete.
Rewinding the Non clog submersible motor of capacity 1HP suitable to run on 415V, AC, 50Hz supply with copper enameled copper wire of suitable gauge/size including proper insulating and making connection to the terminal plate complete.
Disconnecting the Non clog submersible pump and dismantling from the foundation, shifting to workshop opening, checking for defects parts, greasing, bearing etc incl carrying out minor repair.
Disconnecting the sullage water pump and dismantling from the foundation, shifting to workshop for opening, checking for defects parts, greasing, bearing, etc incl carrying out minor repair
Disconnecting the air compressor and motor dismantling from the foundation, shifting to workshop, opening checking for defects parts, greasing, oiling , bearing etc incl carrying out minor repair.
Replacement of complete worn out LT panel wiring after disconnecting all electrical connection from the motors and making connection testing and commissioning with new parts are as under:-
(i) TPN 16 to 32 Amp.
(ii) TPN 40 to 100 Amp.
(iii) 3 Pole Power Auxiliary / Contactors Type MNX-0, rating 25 Amp.
(iv) Three phase Indicator - Red, Yellow & Blue.
(v) Three three phase Timer Switch.
(vi) Auxiliary Contact - 10A (01 NO + 1NC).
(vii) Three phase rotary switch.
S&F PVC insulated and PVC round sheathed, co conductor (flexible) industrial cable of size 4 sqmm, 3 core 1100 Volts.
S & F High density polyethylene pipes (HDPE) of size 50mm dia fixed complete in floors etc.
M&L for cement concrete in foundations of pipe B1 1:2:4 20mm graded aggregate, smooth finishing without using extra cement complete all as specified and directed
M&L for tasting of treated water collected from STP by authorized lab as per required parameter i.e. PH, TSS, BOD, COD, Oil & Greases etc. Submitting by certificated / reports as approved by Engr-in-Charge.
S&F carbon and sand filter rubber gasket (as per site required) complete with connection and commissioning.
PARGAL CONSTRUCTION CO
M/S M P Construction Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .