| 1 | L1₹18.9 LAccepted-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | ₹18.9 L Quoted ₹19.5 L | L1 | Accepted-AOC Lowest AND Reasonable |
| 2 | L2₹21.5 L+₹2.0 L (10.0%)Rejected-Finance | ₹21.5 L+₹2.0 L (10.0%) | L2 | Rejected-Finance Not Lowest |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
20 Apr 2022, 6:00 pmClosed
CWE JAIPUR
HQ CWE Jaipur, Kalyan Marg, Jaipur
REPAIR AND MAINT OF CENTRAL AC PLANT AHU, AIR WASHERS CONNECTING COOLING TOWERS COMPRESSORS AND CONNECTED ITEMS AT HQ SWC BLDG AT JAIPUR MIL STN
2022_MES_515324_1
CWE/JPR/82140/E8
Open Tender
Miscellaneous Works
Item Rate
365 days
GE JAIPUR
enlisted with MES in Class D and above and category C(i)
7 documents required · 7 mandatory
₹500
Yes
GE Jaipur
₹64,000
Yes
1 Aug 2022
25 Mar 2022
23 Apr 2022
25 Mar 2022
20 Apr 2022
7 Apr 2022
Amount
M&L for comprehensive periodical maintenance, repair & servicing of Screw type compressor unit, Shell & Tube type Condenser unit of Central Air Conditioning Plant. Make: Voltas of capacity 200TR as per manufacturer instructions by authorised dealer of company including descaling of machine and connected water pipe line using suitable chemical, greasing & lubrication of moving parts, leakage repair including brazing work, nitrogen testing etc. and replacing the defective or unserviceable spare parts in repairs as below for 200 TR Voltas Screw Chillers of Central AC Plant as directed by Engr-in-Charge. Note:- (i) Spare parts shall be measured and paid for separately under respective item. (ii) Cost of Labour of connecting item Nos 1.01 to 1.20 are shall deemed to be included in quoted rate of this item.
Supply only DUAL PLT of voltas or equivalent etc complete all as specified and directed.
Supply only PRV of voltas or equivalent etc complete all as specified and directed.
Supply only FILTER DRIER SHELL 48-2-20W, 7/8" of voltas or equivalent etc complete all as specified and directed.
Supply only FILTER DRIER DML83s (023Z5058), 3/8" of voltas or equivalent etc complete all as specified and directed.
Supply only EXPANSION VALVE ETS400B (034G3501) of voltas or equivalent etc complete all as specified and directed.
Supply only SOLID DC 48 CORE (023U4381) of voltas or equivalent etc complete all as specified and directed.
Supply only SOL VALVE 7/8" EVR15s (032F1225) of voltas or equivalent etc complete all as specified and directed.
Supply only LIQ.SOL VLV EVR25, 1-3/8" CONN '032L2208 of voltas or equivalent etc complete all as specified and directed.
Supply only Oil filter RC2-410/470/510/550/580/620 of voltas or equivalent etc complete all as specified and directed.
Supply only DRIVER EEXV of voltas or equivalent etc complete all as specified and directed.
Supply only 16 SENSOR INPUT MODULE (SI 16-AO4) of voltas or equivalent etc complete all as specified and directed.
Supply only TEMP SENSOR of voltas or equivalent etc complete all as specified and directed.
Supply only PRESSURE SENSOR of voltas or equivalent etc complete all as specified and directed.
Supply only CHILLER PLC CONTROLLER of voltas or equivalent etc complete all as specified and directed.
Supply only N.C Type (SV1) RC2 of voltas or equivalent etc complete all as specified and directed.
Supply only Solenoid coil 12W 220V RC2 of voltas or equivalent etc complete all as specified and directed.
Supply only Oil level switch RC2 of voltas or equivalent etc complete all as specified and directed.
Supply only discharge temp sensor, 2m RC2, 4405-229 of voltas or equivalent etc complete all as specified and directed.
Supply only R-134a Refrigerant of voltas or equivalent etc complete all as specified and directed.
Supply only Lub oil for Frame 4 compressor for topping up of voltas or equivalent etc complete all as specified and directed.
M&L for complete overhauling of Cooling Tower of 250TR Central AC Plant by dismantling PVC Honeycomb fills, cooling fan, sprinklers, draining out of water, removing algae, silt, cleaning complete cooling tower body by removing scale, dust, dirt, cleaning existing external surface and servicing of mechanical components including repair / replacement of bottom tray of cooling tower, including replacement of gear box bearing, gear oil, mechanical coupling and overhauling of the complete transmission system of cooling tower and re-assembling all the dismantled components to its original position, testing complete to the entire satisfaction of Engr-in-Chage and replacement of following unserviceable parts in repair as directed by Engr-in-Charge. Note:- (i) Spare parts shall be measured and paid for separately under respective item. (ii) Cost of Labour of connecting item Nos 2.01 to 2.04 are shall deemed to be included in quoted rate of this item.
Supply only PVC fills (Big size) in columns of size 60 x 30 x 15 cm or next higher size as per existing specification and requirement etc complete all as specified and directed.
Supply only PVC fills (small size) in columns of size 60 x 15 x 15 cm or next higher as per existing specification and requirement etc complete all as specified and directed.
Supply only roller bearing / Pedestal bearings for fan motor as per sample of Make SKF No. 6213 as per existing make and model etc complete all as specified and directed.
Supply only Fan Motor belt B-118 as per existing make and model etc complete all as specified and directed.
S&F in repairs Ultrasonic Modular Plate (3kg/hr) parts of Ultrasonic Humidifier as per existing make and model etc complete all as specified and directed.
S&F in repairs Ultrasonic Humidifier 4” Fan as per existing make and model etc complete all as specified and directed.
M&L for complete overhauling of Hot Water generator of Make Rapid Coolby unscrewing and draining out water to detect leakages, welding wherever necessary, removing burnt heater , cleaning, removing silt etc from bottom level of tank, putting insulation sleeves to bare conductors and re-assembling all the dismantled components and testing complete to the entire satisfaction of Engr-in-Charge and replacing the following unserviceable parts in repair as required. Note:- (i) Spare parts shall be measured and paid for separately under respective item. (ii) Cost of Labour of connecting item Nos 4.01 to 4.16 are shall deemed to be included in quoted rate of this item.
Supply only Heater Rod 25KW, suitable 3 PH, 415V AC of make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Heater Plate make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Heater Gasket make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Thermostate and control switch ON/OFF assy control auto and manual parameters. make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Level Switch make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Contactor (25-45 Amps) make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Indicating Light - RYB & Amber make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Push Button - RYB & Black make Rapid cool or equivalent etc complete all as specified and directed.
Supply only On /Off Switch make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Step controller Display make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Step controller Card make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Power Supply (12-24V) make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Sensor wire make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Relay (8-14 pin) make Rapid cool or equivalent etc complete all as specified and directed.
Supply only Relay 8 pin (LY2N) as make Rapid cool or equivalent etc complete all as specified and directed.
Supply only BMS Card make Rapid cool or equivalent etc complete all as specified and directed.
Dismantling, opening, rewinding and refixing 3 phase, 440V, 50 Hz induction motors with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechnical works for shaft/bearing housing , renewal of DE and NDE beaings, transportation from installation to workshop & back, connecting testing and commissioning at site for satisfactorily operation etc complete all as specified and directed of following capacity:-
(a) 3 HP to 7.5 HP capacity
(b) 7.5 HP to 15 HP capacity
(c) 15 HP to 20 HP capacity
Dismantling and taking out defective monoblock pump of capacity upto 100 LPS from foundation and shifting to workshop for repair/replacement of impellers, beanings, seals etc. Refitting at foundation after repair testing and commissioning etc complete all as specified and directed.
Dismantling and taking out defective centrifugal pump of capacity 123 cum /hr ,from foundation and shifting to workshop for repair/replacement of impellers, bearings, seals etc, Refitting at foundation after repair testing and commissioning complete to the entire satification as required.
Disconnecting the electrical and mechanical connection of burnt electrical motors from the site / location, transporting to and from to work shop. Rewinding of electrical motors/ pump motors by dismantling and removing the burnt cut copper winding wire cleaning the slots of stator with petrol and brushes winding polyester based super enamelled copper wire of same gauge of original one with proper class of insulation including varnishing and heating the coil and remove air bubbles complete stator / rotor after rewinding reassembling all parts including reinstalling connection to original position and testing on full load all as directed by Engineer in charge for different capacity of motor as per following :-
(a) 1 to 2 HP capacity
(b) 3 to 5 HP capacity
(c) 7.5 to 15 HP capacity
(d ) 16 to 40 HP capacity
S&F in repairs ball bearing for squirrel cage induction motor of capacity 1 HP to 20 HP as per existing make and model etc complete all as specified and directed.
S&F in repairs ball bearing for squirrel cage induction motor of capacity 25 HP to 75 HP as per existing make and model etc complete all as specified and directed.
Checking and testing of interlock panel wiring, detecting the fault/defects including replacement of burnt wires, lugs, terminals, etc. complete all as per specified and directed.
Servicing of Air washer upto 3800 CFM unit including cleaning of pads with chemical and cleaning of air filters, draining out old water from inlet and outlet pipes and refilling fresh water and testing after servicing complete all as specified and directed
Supply and installation wet & dry bulb thermometer at A/C plant room etc. complete all as per specified and directed.
S&F in repairs "V" belt for power transmission for AHU and Air washers of series A,B,C of different sizes as per existing make and model etc complete all as specified and directed.
M&L for complete overhauling of water Softener Unit which include servicing, cleaning of complete unit by suitable means and replacing the defective parts etc complete all as specified and directed. Note:- Defective parts replaced will be measured and paid separately in respective item of BOQ.
Supply only spare parts of water softener unit as per existing as follows:
Side Mounted Multiport valve 40 NB
Strainer Neck type
Rubber Gasket For Multiport valve 40NB
Ejector for Multiport valve
Pressure Gauge 0-7 kg/cm2, 65mm
Thermax tulsion T-42-Na resin
Auto Air Vent 20mm dia.
Pressure Gauge with Adapter
Water Flow Switch
S&F in repair Two way pressure independent control Valve (Brass body) of size 20 mm to 32 mm dia as per existing Make of Anergy or equivalent etc complete all as specified and directed.
S&F in repair Two way pressure independent control Valve (Brass body ) of size 40 mm to 65 mm dia as per existing Make of Anergy or equivalent etc complete all as specified and directed.
S&F in repair Rotary Actuator, modulating, 05 Nm, 24Vac/dc, 0-10Vdc input, 2-10Vdc feedback, Form Fit. etc complete all as specified and directed.
S&F in repair Electronic Temp. Controller with LED display, 24Vac, 3 External temperature Sensor input, 2-10Vdc input (BMS), Range 15°C-35°C, 0°C-50°C, 0-10Vdc output with temperature differential limit. etc complete all as specified and directed.
S&F in repair Linear Actuator, Modulating, 500N, 24Vac/dc, 0-10Vdc input,2-10Vdc feedback, suitable for 40mm, 50mm dia valves etc complete all as specified and directed.
S&F in repair Linear Actuator, modulating, 600N, 24Vac/dc, 0-10Vdc input, 2-10Vdc feedback, suitable for 65 mm,80mm, 100mm dia valves. etc complete all as specified and directed.
S&F in repair Temperature Sensor Bulb Type with Cable Gland, Range (-)30°C to (-)70°C. etc complete all as specified and directed.
S&F in repair installation, testing Switched-Mode Power supply (smps) etc complete all as specified and directed.
S&F in repair installation, testing and commissioning Humidity sensor of Make: Subzero or equivalent etc complete all as specified and directed.
S&F in repair motorised fire damper Actuator suitable for operation on 240 volts ,AC minimum motor (torque 20Nm) open/close operation/2X SPDT auxiliary built in switch all as per Make- Belimo Model No NFU-S2 or equivalent etc complete all as specified and directed.
S&F in repair evaporative cellulose paper fill pads for Air washers cellulose pads shall be factory assemble size of 1200X600X200 mm etc complete all as specified and directed.
S&F in repair Propeller type free discharge exhaust fans complete with motor, fan, exhaust Louvers of 250 to 300 mm sweep etc complete all as specified and directed.
Taking down supply air duct and modifying supply air duct of air washers for increasing the airflow in the room by providing vanes in the ducting made out of GI sheets etc complete all as specified and directed by engineering in charge.
Supply, installation & commissioning duct inline fans of capacity 1200,10 mm static pressure inside supply air duct for improving the airflow in room to 1800 cfm by making necessary cable connections & necessary modifications in the duct design.
M&L for dismantling of old duckting of any type and shape including all accessories viz. Corner, Cleat, Carriage bolt, Gasket etc complete all as specified and directed.
Supply, assembly and erection of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints of size 24 Gauge etc complete all as specified and directed.
Note for Srl Item Nos 29.00 & 32.00 :- (i) All necessary civil work including dismantling & fixing of false ceiling , making & breaking of walls & making good damaged portion by painting etc. is included in above scope of work (ii) All electrical cables, lugs, casing capping, PVC pipes for cables etc are included in above rates quoted.
Supply, fabricate & Erect MS angle/channel of suitable size welding to existing vertical structure of ducting in replacing of rusted/deteriorated angle/channel as directed by Engr-in-charge (size of angle =50mmx50mmx5mm and channel 100mmx100mmx5mm)
Supply and replacement of double fitted polymer fabric HDPE fresh air filter (filter class -G3 as per EN 779) washable/cleanable type having efficiency 95% to 99% down to particle size of 20 micron, fabricated out of CRCA Sheet metal duly painted with two coat of spray hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc. complete all as specified & as directed by Engr-in-charge of following sizes:-
(a) 600mmx600mmx50mm
(b) 600mmx300mmx50mm
S&F in repair and testing ACB 1250A, 4 pole adjustable thermal/magnetic setting, 415 V, 50 KA of make L&T or equivalent etc. complete all as specified & as directed
Servicing of AHU upto 10000 CFM unit including cleaning of cooling coils with chemical and cleaning of air filters, micro filters, draining out old water from inlet and outlet pipes and refilling fresh water and testing after servicing upto entire satisfaction etc. complete all as specified and directed.
S&F in repair extended rotary handle for MCCB of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair spreader terminals- 3P of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair single phasing preventer of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair Timer as per existing of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair VFD UNIT FOR 11 KW Pump of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair VAF Meter of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair KWH Meter digital type of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair push buttom start/stop with elements of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair auto manual switch 1 pole of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair current transformer 1250/5A,5VA (100 x 10 - 2 runs) of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair current transformer ( 800/5A,5VA(80 X 10 ) to 60/5A,5VA to 30/5A, 5VA ) of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair current transformer ( 400/5A,5VA (50 X 5) to 125/5A,5VA) of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair MCCB 400A, TP,415V, 50 Hz, 36KA adjustable type of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair MCCB 250A, TP, 415V, 50 Hz 36KA adjustable type of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair MCCB 160A, TP,415V, 50 Hz 36KA adjustable type of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair MCCB 100A, TP, 415V, 50 Hz,16KA adjustable type etc complete all as specified and directed.
S&F in repair MCCB 32A, TP, 415V, 50Hz,16KA adjustable type of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair MCB 63A, TP, 415V, 50 Hz of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair MCB 32A, TP, 415V, 50 Hz of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair MCB 6 to 16A, TP, 415V, 50 Hz of make L&T or equivalent etc. complete all as specified & as directed
S&F in repair Contactor of make L&T or equivalent of following capacities:-
(a) 38 Amps
(b) 32 Amps
(c) 25 Amps
(d) 22 Amps
(e) 18 Amps
(f) 12 Amps
S&F in repair of over load relay of make L&T or equivalent of following capacities:-
(a) 06Amps-10A Amps
(b) 17 Amps -25 Amps
(c)12 Amps -18 Amps
(d) 28 Amps -36 Amps
S&F in repair PVC Eliminators (5 bend 6 pass) thickness 1.3 mm, width 255 mm of size : 2400 mm (h) 3000 mm(w)x 255mm(d) long . etc. complete all as specified & as directed.
S&F in repair aluminium double deflection Hot Rolled Duct Grill powder coated, dual adjustable type of size 600x600 mm with fixing accessories etc. complete all as specified & as directed.
Schedule of Credit
Shree Karni Electrovision
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .