Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹10.9 L+₹5,343 (0.49%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹15.0 L+₹4.1 L (37.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
CLEANING REPAIR OF SEWAGE LINES, SEPTIC TANKS, SOAKAGE WELLS AND ALLIED WORKS AT KG, LKG, JHALLAS, SURANKOTE K NALLAH IN THE AOR OF AGE B/R-III AND REPAIR/ REPLACEMENT OF EXTERNAL SECURITY LIGHTS/ FIXTURES AND CONNECTED WORKSIN THE AOR OF STN HQ
2024_MES_666256_1
GE/PNH-17/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹40,000
Yes
3 Dec 2024
16 Jul 2024
19 Sept 2024
16 Jul 2024
12 Sept 2024
30 Jul 2024
Amount
B&R PORTION:- Opening of cover (of any description and size) of septic tanks and soakage wells/pits, de-sluding / de-watering contaminated with fine waste materials ( liquid sludge) alongwith solid waste from septic tank and soakage wells/pits of any capacity/depth by mechanical pumping (Truck mounted mechanical machine) / manually making it fully functional to to entire satisfaction of Engineer-in- charge and and removing & depositing the sludge outside the periphery of defence land at a minimum distance of 50 m from nearby living accn and burring in borrow pits including covering with fresh mud and refixing the cover after cleaning / removing the liquid waste material of septic tanks / soakage wells / pits including cutting holes through slab/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surfaces complete all as specified and directed by Engr-in-Charge. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
Cleaning of under ground sewage lines of 100mm/150 mm bore including manholes, CI stacks.gully traps etc. by means of cleaning by roding from manholes to manholes till the cleared/cleaned water running under sewage line and flushing after cleaning, taking out sludge collected in manholes, removing & depositing the same outside the periphery of defence land in the pit at a minimum distance of 50 m from nearby living accn and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes including taking off and re-fxing cover the manhole pitt, complete all as specified and directed. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
Cleaning of blockage of Water Closet (Indian or European), trap & pipe line upto first manhole manually by Roding and making it fully functional by flushing with water to entire satisfaction of Enginerr-in-charge including removing the deposited sludge/solid/liquid material, outside MD land and burring in borrow pits including covering with fresh mud, complete all as specified and directed by Engineer-in-charge. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
Demolition or breaking up drain pipe of 100/150 mm dia bore (salt glazed stone ware, AC, PVC or reinforcement concrete) set in cement mortar/concrete complete all as specified and directed.
S&F 150 mm bore salt glazed stone ware drain pipes, grade ‘A’ laid in trenches and jointed in CM 1:3, complete all as specified and directed by Engr-in-Charge.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor, complete all as specified and directed by Engr-in-Charge.
M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipes for 150mm SGSW pipe after they are laid in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) & tested, complete all as specified and directed.
Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth for foundation etc. and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as specified and directed by Engineer-in-Charge.
M&L for precast cement concrete 1:2:4 type B1 (20mm graded crushed stone aggregate) as in landings, cover slab for man holes etc set in cement mortar(1:6), complete all as specified and directed.
S&F TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically described complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling, mass concrete and sub base, complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for Walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
All as per Srl item No. 17 above, but except stone complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4, complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm to face stones (lime and sand stone) and dressing of face beds and joints, complete all as specified and directed.
M&L for cement concrete (1:2:4) type-B-1 (using 20mm graded stone crushed aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs, in edging of path (interlocking paver) and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified.
Taking down cement plastering on lathing (other than wire netting) without removing lathing complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on other than fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base to flooring/path etc. finished even & fair, complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc. finished even & fair, complete all as specified and directed.
M&L for chequered cement concrete tiles with chemical resistant coating if size 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed with grey cement mixed with pigments, laid over and including 20mm thick screed bed in CM 1:4, complete all as specified and directed.
Cleaning of blockage of nahani trap/gully trap incl cleaning of sewage line/manholes upto and incl 1st manholen and making it fully functional inclo entire satisfaction of Enginerr-in-charge including removing the deposited waste material, outside MD land and , complete all as specified and directed by Engineer-in-charge. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer and users requisition slip alongwith completion shall be produced before payment to contractor
S&F in repair PVC (SWR) pipes 75mm dia any length single socketed with rubber ring joint fixed to wall, complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall, complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) bends diminishing pieces or tapers, any radius 75mm bore, complete all as specified and directed.
S&F in repair PVC (SWR) bends diminishing pieces or tapers, any radius 110mm bore, complete all as specified and directed.
S&F in repair PVC (SWR) branch pieces, double (double Y) equal or unequal, 75mm bore, complete all as specified and directed.
S&F in repair PVC (SWR) branch pieces, double (double Y) equal or unequal, 110mm bore, complete all as specified and directed.
S&F in repairs PVC (SWR) floor trap of 75mm dia of outlet, plain with grating including jointing with solvent cement fixed in repair, complete all as specified.
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white, (excluding flushing cistern & flush pipe) complete connection to drain (outgoing pipe) and to flushing pipe and anti syphonage pipe etc with & including fixing bolts, complete all as specified and directed.
S&F in repair vitreous china squatting pan (Orissa pattern) size 580 x 440 mm, snow white, with 'P' or 'S' trap, front or back inlet and integral foot rests, complete connection to drain (outgoing pipe) and to flushing pipe and syphonage pipe etc. including lime concrete bedding, complete all as specified and directed. Make:- Prayag cat part No4054 or Equaivalent cat part of make as specified in P.S.
S&F in repair PVC valve less syphonic action type flushing cistern 10ltr capacity , low level white with inlet ball valve float and handle including brackets including 32mm dia PVC. flush pipe for low level cistern including all joints complete all as specified and directed. Make:- Prayag cat part No 501 or Equaivalent cat part of make as specified in P.S.
S&F in repair 40 mm dia, Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm, fixed to wall/ceiling or in floors incl necessary fittings, complete all as specified and directed.
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11sqm but not exceeding 0.18sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles, over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11sqm but not exceeding 0.18sqm, as in skirting/dado etc and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles, over and including 10mm thick rendering in CM (1:4), complete all as specified and directed.
M&L for filling of soakage pits with fresh broken bricks of gauge 40 to 80 mm size, complete all as specified and directed.
S&F in repair cast iron cowl suitable for 75 mm bore pipe, ccomplete all as specified and directed.
S&F in repair vitreous china urinals, bowl type of size 465x355x265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern and waste pipe),complete including poviding and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing with automatic flushing cistern with brackets, flush pipe, waste pipe grating and union for discharge pipe complete all as specified and directed.
S&F in repair grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms), suitable for floor taps, complete all as specified and directed.
E/M PORTION:- Taking down old unsv street light fittings any type from pole/ wall/ other similar situation and refixing, re-connecting the same in existing position after carrying out necessary repair/ replacement of unsv accessories to make the fittings functional, complete all as speecified and directed. Note:-Accessories required to make the fittings functional shall be measured & paid seperately as supply only under relevent items.
Supply only the following accessories to be incorporated for repair of street light fittings taken out under item No 48 above are as under:-
LED driver for street light fittings of 25 to 35 watt capacity complete all as specified and directed.
LED driver for street light fittings of 40/45 watt capacity complete all as specified and directed.
LED driver for street light fittings of 60/70 watt capacity complete all as specified and directed.
LED driver for street light fittings of 90/120 watt capacity complete all as specified and directed.
Glass cover for street light fittings upto 120 watt capacity complete all as specified and directed.
S&F thermo plastic street light weather proof out door type junction box of size 200mmx 160mm x 98mm complete with 4 way connector-01 No, 6 Amps SP MCB-01 No, easily openable and having locking arrangement including incoming and out going cable holes with fixing MS clamp and water tight polymide cable gland for each connection with & including taking down old unsv junction box, complete all as specified and directed.
Excavation in trenches n.exc 1.5M wide and n.exc 1.50M in depth for taking up or laying of under ground cable in soft/loose soil and getting out complete all as specified and as directed.
Returning, filling soil in trenches including spreading levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removal excavated soil not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point all as specified and as directed.
Supply and laying in trenches or passing through pipe 1100 volts grade armoured, heavy duty XLPE electric cable with aluminium conductor of size 25 Sqmm 3.5 core including taking down old/ unsv cable any type complete all as specified and directed.
All as per Item No 59 above but 16 Sqmm 2 core complete all as specified and directed.
All as per Item No 59 above but 10 Sqmm 2 core complete all as specified and directed.
S&F in repair 40mm bore galvanised steel water tubing, light grade including all fittings laid in trenches/ fixed to pole/ along wall/ floor etc for protection of cable/ strip including fixing to pole with M.S. clamp, nuts, bolts etc complete all as specified and as directed.
Supply & fix PVC insulated, 1100 volts grade, stranded aluminium conductor cable 2.5 Sqmm, twin core, connecting from Street light junction box to light fittings including taking down old/ unsv cable any type complete all as specified and directed.
S&F in repair PVC conduit/pipes 25 mm dia and fixed with the pole by clamping / saddling for protection of connecting wires, connection from junction box to light fittings, including taking down old pipe any type complete all as specified and as directed.
S&F in repair decorative post top lantern LED light made up of high grade unbreakable polycarbonate material suitable for & including 20 watt LED lamp (B22) fixed with & including stand post of 40mm dia GI pipe light grade, 1 mtr long and making connection with three core copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:- Havells Cat Part No. LHFXBON1TN5Q014 or Equivalent cat part of make as specified in PS.
Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: HAVELLS Cat Part No. ENDCITYLITPLAT+SL35WLED757SASYBOPCWOSPD or equivalent Cat part of Make as specified in PS.
Supply and fixing in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No. ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent Cat part of Make as specified in PS.
Supply and fixing in repair LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make: Havells Cat Part No. ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent Cat part of Make as specified in PS.
Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type die cast aluminium body with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing in repair LED flood light 100 watt 230 V AC outdoor type die cast aluminium body with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F street light bracket made out of GI tubing 40mm bore, medium grade, 1.5 metre long bent to shape as directed, including suitable MS clamp of MS Flat with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint including taking down u/s bracket any type complete all as specified and directed.
Supply and fixing 1100 Volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable flat or circular of size of aluminum conductor 10 sq mm stranded conductor including taking down old UNSV cable complete all as specified and directed.
S&F in repair Earthing in replacement for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 600x600x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm with GI pipe, nuts, bolts and washers complete upto and PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protected steel with funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009.
S&F in repair of aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point complete all as specified and directed.
S&F in repair of copper strip 20 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point complete all as specified and directed.
S&F in repair of galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe complete all as specified and directed.
S&F in repair of single pointed air termination aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
S&F in repair of test point terminal block made of gun metal or phosphorous bronze 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point complete all as specified and directed.
Supply, laying and fixing DWC HDPE pipe (Orange colour) for protection of power cable of size 50 mm dia, complete with all fittings/fixtures, cutting ang jointing, complete all as specified and as directed.
narayan construction (BID ID -3086550)
ABINASHI ENTERPRISES (BID ID -3093677)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .