| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.8 L+₹3.3 L (17.9%)Rejected-AOC | L2 | Rejected-AOC BIDDER NOT LOWEST | |
| 3 | L3₹23.0 L+₹4.5 L (24.2%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC BIDDER NOT LOWEST | |
| 4 | L4₹27.0 L+₹8.5 L (46.1%)Rejected-AOC | L4 | Rejected-AOC BIDDER NOT LOWEST | |
| 5 | L5₹28.9 L+₹10.4 L (56.3%)Rejected-AOC 2 8 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L5 | Rejected-AOC BIDDER NOT LOWEST |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
22 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT
GE WEST DELHI CANTT 10
ESSENTIAL REPAIR MAINTENANCE WORKS TO CARIAPPA VIHAR AND MT LINE AND OTHER ADJOINING AREA OF AGE EM UNDER GE WEST DELHI CANTT 10
2020_MES_350518_1
GE/DW-63/2020-21
Open Tender
Civil Works
Item Rate
240 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹64,000
4 Dec 2020
26 Jun 2020
24 Jul 2020
26 Jun 2020
22 Jul 2020
10 Jul 2020
60 days
Amount
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket/power) complete (fittings such as switches, ceiling roses, holders, sockets, light fittings, bells etc) and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed.
M&L for point wiring with 3 x1.5 sqmm (nominal area) FRLS PVC insulated unsheathed and copper conductor cable ( phase, neutral and earth wire ) in existing concealed conduit /open PVC rigid conduits, earth wire connected to comman earth dolly with and including pressed steel sheet metal sunken box of suitable size for fixing switches/ sockets etc with cover plate 3 mm thick plastic laminated sheet for one light /fan /exhaust fan/ circulator fan/ bell /buzzer controlled by one way switch complete all as specified and directed :-
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
All as per item No. 2 (a) here in before but with 3x2.5 Sqmm (nominal area) FRLS PVC insulated unsheathed and copper conductor cable ( phase ,neutral and earth wire) 15 Amp power point complete all as specified and directed
S&F switch piano flush button type 5 amps single pole one way complete all as specified and directed.
S&F switch piano flush button type 15 amps single pole one way complete all as specified and directed.
S&F socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S&F ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
S&F bell push 5 amps single pole one way complete all as specified and directed.
S&F bell ding dong complete all as specified and directed.
S&F FRLS insulated single core unsheathed multistanded cable copper conductor 1100 volt 1.5 sqmm completed all as specified.
S&F FRLS insulated single core unsheathed multistanded cable copper conductor 1100 volt 2.5 sqmm completed all as specified..
S&F FRLS insulated single core unsheathed multistanded cable copper conductor 1100 volt 4 sqmm completed all as specified..
S&F in repair outer shell of geyser with collar made out of existing size and guage of MS sheet suaitable for geyser of capacity 25 ltr complete all as specified and as directed.
S&F in repair of capaciator 2.50 Mfd, 240 V complete all as specified and directed.
S&F in repair batten holder including with connecions complete all as specified and directed.
S&F in replacement 9 Watt LED Bulbs, high energy efficiency LED luminaire with confirming technical specification / Data sheet Annexuire-3,
S&F in replacemen18 W LED tube light fitting 4 Ft length (Retrofit Type) high energy efficiency LED luminaire complete with inbuilt driver with incl making connections and disconnecting existing electronic blast or starter with all arrangements for fixing at site complete all as directed
S&F in replacement 7 W LED Bulbs, high energy efficiency LED luminaire withconfirming technical specification / Data sheet Annexuire-3,
S&F in repair double pole MCB 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed..
S&F in repair Single pole MCB 6 to 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed.
S&F in replacement LED tube rod 20 Watt complete all as specified and directed.
S&F in repair Switch socket combination 6/16 A 250V AC universal with box in polycarbonate complete all as specified and directed.
S&F in repair switch piano flush button type 5 amps single pole one way complete all as specified and directed.
S&F in repair switch piano flush button type 15 amps single pole one way complete all as specified and directed.
S&F in repair socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F in repair socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S&F in repair ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
S&F extention board 4 way AC 230 volt minimum 7 mtr long extention cable complete all as specified and directed.
M and L for painting of Exhaust Fan in situ with synthetic enammeled paint by spraying including fillings cavaties with filter ,one coat after cleaning all dust etc all as specified & directed.
S&F in repair Exhaust fan blade for existing exhaust fan 200,250 and 300 mm sweep dia complete all as specified and directed.
S&F Hylam sheet size of 8 x 12 inch in white colour including cuttiing hole for switch and socket complete all as specified and directed.
S&F Hylam sheet size of 6 x 8 inch in white colour including cuttiing hole for switch and socket complete all as specified and directed.
S&F Single pole MCB 6 to 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed.
S&F double pole MCB 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed..
S&F MCB TPN 63 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete all as specified and directed
S&F in repair switch modular 6 Amps 230 Volts one way etc complete all as specified and directed.
S&F in repair socket modular 5 pin 6 amps etc complete all as specified and directed.
S&F in repair switch modular 16 Amp 230 Volts etc complete all as specified and directed.
S&F in repair universal socket modular 2 in 1, 3 pin, 5 and 16 amps etc complete all as specified and directed.
S&F in repair Electric bell Ding-Dong AC 230 Volt etc ccomplete all as specified and directed.
S&F in repair fan regulator step type ccomplete all as specified and directed.
S&F in repair metal clad plugs 2 pole + earth rating 20 amps 250volt complete all as specified and directed.
S&F in repair metal clad sockets 2 pole + earth rating 20 amps 250 volt complete all as specified and directed.
S&F in replacement 10 W LED, surface mounted , decorative oval bulk head edge-lit LED luminarie comprising of high brightness LED luminaire with lumen output to be fitted with colour temperature 6000K,, confirming technical specification
S&F in replacement 10/12 W LED tube light 2 Ft length (Retrofit Type) high energy efficiency LED luminaire complete with inbuilt driver to be fitted. Surface /wall mounted tube light fitting with incl making connections complete all as directed & specified
S&F in replacement 5 watt LED 4000K Environment friendly, energy efficient, aesthetically designed, surface ornamented with rings, moulded body, wall/ceiling light LED fixture with diffuser to give glare free light, ovale shape engineering plastic housing with PC cover. complete all as specified and directed.
S&F blanking plate plastic made minimum 10 CM dia Round shape white colour for cover blank hole off wiring junction box complete all as specified and directed
S&F combined Myrius or equivalent in Crabtree(Picadly)/Anchor(AVE) White Cover plate with frame(Inner & Outer) including flush mounting boxes suitable for modular switch/socket of following module complete all as specified and directed
(a) 2 Modular. Cat Part No. 673202 of Legrand or equivalent in Crabtree(Picadly)/Anchor(AVE)
(b) 3 Modular . Cat Part No. 673203 of Legrand or equivalent in Crabtree(Picadly)/Anchor(AVE)
(c) 4 Modular. Cat Part No. 673204 of Legrand or equivalent in Crabtree(Picadly)/Anchor(AVE)
(d) 6 Modular. Cat Part No. 673206 of Legrand or equivalent in Crabtree(Picadly)/Anchor(AVE)
(e) 8 Modular. Cat Part No. 673209 of Legrand or equivalent in Crabtree(Picadly)/Anchor(AVE)
S&F plug top of 15 Amps sutable for existing 15 Amps socket complete all as specified and directed.
S&F inner shell of Steel body suitable for geyser of capacity 25 ltr complete all as specified and directed.
S&F repair copper heating element 1500 watt embedded copper, sheathed tubular with theremostat casing cap triangular type of IS : 4159 complete all as specified and directed.
S&F thermostat suitable to work water temperature 30° to 75° C electric cut up for any type of water heater complete all as specified and directed.
S&F repair copper flange assembly suitable for 25 ltrs capacity water storage heater (geyser) with nut & bolt as per site requirement complete all as specified and directed.
S&F PVC connection 400 mm long with nut bolt washer reqd for water heater off sizes.
Supply and Fix in repair single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
S&F in repair Building security light Endura Cityliner 45 W LED 6K, is new generation energy saving and environment friendly light fitting which uses 12 Nos , high power LEDs as light sourrce, complete all as specified and directed.
S&F in repair MCCB 250 Amp 4 pole 35 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F in repair MCCB 63 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F in repair MCCB 100 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F in repair MCB TPN 63 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete all as specified and directed
Checking and attending complaints by means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES daily except national holidays complete all as specified and directed. Note: 1. This item covers cost of labour for attending complaint comprising taking down of old material and fixing of item issued by the Deptt. 3. Complaints noted'' NO Light'' shall be attended imediately up to 2200 hrs without fail, failing which recovery of Rs. 240.00 per complaint shall be effected from the contractor's dues. 4. Minor items as PVC wire of any size as per requirement up to 1.0m length, thimbles, electric tape etc shall deemed to be included in the quoted rate of this item. 5.The complaint shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed and recovery shall be effected from contractor's dues. In case after checking & attending the defects, if it is not possible to rectify the defects within 08 hrs ie from 0900 hrs to 1700 hrs, the facts shall be brought to the notice of Engr in charge immediately by the contractors/his rep. The decesion of Engineer in Charge to effect recovery on this account shall be final and binding. 6. Contracror shall arrange suitable T&P incl necessary from work and scoffolding and safety measures to make it functional complete all as specified and directed. 7. Contractor or his rep will report daily at complaint cell for collection of complaints from the concerned JE in charge . 8 Job slip as per sample shall be provided by the contractor free of cost. 9. The contractor is advised to inspect site and to note that he has to deploy daily men power to collect the complaints from two complaint cells. Contractor's quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account.
Taking down ceiling/exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store hanging the ceilling fan and refixing the exhaust fan same complete all as specified and directed.
M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) including taking out old wind copper wire with appropriate gauge and quantity, both sides of rewinding covered with high quality varnish complete including replacement of ball bearing as requirment of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep including transportation charge from mes store to garrage t complete all as specified and directed.
M&L for rewinding exhaust of 300mm/450mm sweep of any type & make complete with super enamelled copper wire (HTP) including taking out old wind copper wire with appropriate gauge & qunatity, both sides of rewinding locked with high quantity varnish complete inclusion of ball bearing of SKF/NBC make and provisions of new nuts pin including transportation charge from mes store to garrage all as specified & directed.
M and L for painting of ceilling fan in situ with synthetic enammeled paint by spraying including fillings cavaties with filter ,one coat after cleaning all dust etc all as specified & directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking down and complate connection all as specified and directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of IC x 10.00 sqmm (Main Cable and neutral) and one run of IC x 06 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking down and complate connection all as specified and directed.
S & F in repair of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
Supply and Fix in repair factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F Gang box 15 amps includiing switch and socket fix completely making conection
S&F Gang box 5 amps includiing switch and socket fix completely making conection
S&F of meter box of 1.6 mm thick thermoplastc sheet of size 40 cm x 20 cm x 15 cm with provision of door duly hinged at one side including provision of visible glass of size 10 cm x 10 cm on door panel for reading the unit consumption.
Deduct Credit: for demolished/dismantled material of (-) Rs 192581.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
M/s S.G. BUILDERS
M/S ANIL KUMAR
M/s M M BAHL
jain associates
SETHI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .