Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.2 L+₹39,690 (22.2%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹2.4 L
Closing Date
17 Nov 2021, 9:30 amClosed
Executive_Engineer
EE, EandM, Division, APWD, Prothrapur, Port Blair
AR and MO Air Conditioners Installed in Inter Island Helicopter Passenger Terminal and Hanger Building under Sub Division IV EandM Division APWD Port Blair during the year 2021-22
2021_APWD_4216_1
NIT No. 53/EE/EandM/21-22
Open Tender
Electrical Works
Item Rate
365 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
2 Dec 2021
5 Nov 2021
17 Nov 2021
5 Nov 2021
17 Nov 2021
11 Nov 2021
8 Nov 2021 - 10 Nov 2021
Amount
Schedule (Staffs) Air Conditioner Mechanic
Khalasi
Schedule (Materials) Supplying, Installation, Testing and Commissioning of Condenser unit complete of Split Type AC 1.5 Ton Capacity.
Supplying, Installation, Testing and Commissioning of Condenser unit complete of Split Type AC 2.0 Ton Capacity.
Pressure testing for leakage flushing vaccummission the system, gas charging with Freon-R 22 servicing the unit testing for satisfactory performance, replacement of necessary spare parts i/c re-installation of the unit etc as required for AC (1.5 Ton)
Pressure testing for leakage flushing vaccummission the system, gas charging with Freon-R 22 servicing the unit testing for satisfactory performance, replacement of necessary spare parts i/c re-installation of the unit etc as required for AC (2 Ton)
Replacement of defective compressor unit with new one suitable for 2 Ton capacity room AC i/c pressure testing for leakage flushing vaccummission the system, gas charging with freon-22 servicing the unit, painting and testing for satisfactory performance, replacement of necessary spare parts i/c reinstallation of the unit duly tested etc as required .
Replacement of defective compressor unit with new one suitable for 1.5 Ton capacity room AC i/c pressure testing for leakage flushing vaccummission the system, gas charging with freon-22 servicing the unit, painting and testing for satisfactory performance, replacement of necessary spare parts i/c reinstallation of the unit duly tested etc as required.
Supplying of AC Indoor Blower Motor for 2.0 Ton Capacity
Supplying of AC Indoor Blower Motor for 1.5 Ton Capacity
Supplying of PCB Assembly Split AC Common- Artic/ Universal Board by New One for 1.5 / 2.0 Ton Capacity
Supplying of Out Door Fan Motor for 2.0 Ton Capacity
Supplying of Out Door Fan Motor for 1.5 Ton Capacity
Supplying of 50 Mfd Capacity for AC
Supplying of 60 Mfd Capacity for AC
Supplying of 3.15 Mfd Capacity for AC
Supplying of 4.0 Mfd Black Square/ Round Type AC Capacitor
Supplying of Voltage Stabilizer 5 KVAR (SYSCOM/ V-Guard) for 2.0 Ton Capacity
Supplying of Voltage Stabilizer 4 KVAR (SYSCOM/ V-Guard) for 1.5 Ton Capacity
Hi Tech Engineering and consultancy services
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .