Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.7 LAccepted-AOC GROUND FLOOR SUIT NO 2 SARITA APARTMENT KHARIDA MAIN ROAD KHARAGPUR 721 301 DIST PASCHIM MIDNAPORE WEST BENGAL | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721301 | ₹48.7 L Quoted ₹49.1 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹53.7 LRejected-Finance WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹53.7 L | L2 | Rejected-Finance Other than lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Bidder is not enlisted with cat c(i) |
| 4 | Rejected-Technical | - | - | Rejected-Technical Bidder is not enlisted in Cat c(vi) |
| 5 | Rejected-Technical 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | - | - | Rejected-Technical Bidder is not enlisted in Cat c(vi) |
| Sl No | Description | Qty | Unit | Lotas Engineers L1 | G M CONSTRUCTION COMPANY L2 |
|---|---|---|---|---|---|
| 1.00 | Comprehensive monthly maintenance of Auto Fire Alarm System installed in Bearing Hospital in Tech Area at AF Stn Chakeri consisting of the following scope of work as under:-
(i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system.
(ii) Operational of all the equipment of fire detection system should be maintained.
(iii) The contractor will submit daily inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule. | 9 | Each Job | 4,000 ₹36,000 | 9,000 ₹81,000 |
| 1.10Note:- 1. The detail of fire detection & fire fighting system are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (200 device/loop card) - 01 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 73 Nos. (c) UL Listed intelligent heat detector - 02 Nos. (d) Manual call point - 08 Nos. (e) Control module for hooter - 14 Nos. (f) Zone Monitor module - 14 Nos. (g) Fault isolator - 08 Nos. (h) Wall mounted hooter - 14 Nos .(j) Response indicator - 12 Nos. (k) IR Flame detector - 14 Nos. (l) UPS 500 VA - 01 No. 2. Testing of the entirefire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge. | |||||
| 2.00 | Comprehensive monthly maintenance of Auto Fire Alarm Detection and Fire Fighting System installed in M-53 OF 4BRD in Tech Area at AF Stn Chakeri consisting of following scope of work as under:-
(i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system.
(ii) Operational of all the equipment of fire detection system should be maintained.
(iii) The contractor will submit daily inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule. | 9 | Each Job | 4,000 ₹36,000 | 8,000 ₹72,000 |
| 2.10Note:- 1. The detail of firedetection & fire fighting system are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (200 device/loop card) - 01 No.(b) UL Listed intelligent addressable multi-criteria detector with base- 4 Nos. (c) UL Listed intelligent heat detector - 02 Nos. (d) Auto dialer - 01 Nos. (e) External siren - 02 Nos. (f) Nitrogen gas cyclinder 2.2 Kg - 05 Nos. (g) Carbon di oxide cyclinder 45 Kg - 16 Nos. (h) Manual call point - 08 Nos. (i) Control module for hooter - 4 Nos. (j) Zone Monitor module - 4 Nos. (k) Fault isolator - 08 Nos. (l) Response indicator - 12 Nos. (m) IR Flame detector - 02 Nos. (n) UR Gas detector - 04 Nos. (o) Smoke detector - 02 Nos (p) UPS 500 VA - 01 No. 2. Detection system shall be tested monthly along fire fighting system. 3. Fire fighting system and complete system efficiency along with release of Carbon di oxide and Nitrogen shall be tested at least once in three month. 4. Weighing of Carbon di oxide and Nitrogen per month shall be done. | |||||
| 3.00 | Comprehensive monthly maintenance of auto fire alarm system installed in TTCLE Hanger in Tech areaat AF Stn Chakeri consisting of following scope of work as under:-
(i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational of all the equipment of fire detection system should be maintained.
(iii) The contractor will submit daily inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.
(iv) The maintenance shall be carried out through experienced technician.
(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost.
(vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule. | 9 | Each Job | 4,500 ₹40,500 | 14,000 ₹1,26,000 |
| 3.10Note:- The detail of fire detection & fire fighting system are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (200 device/loop card) - 01 No. (b) UL Listed intelligent addressable multi-sensor detector with heat & smoke combination-492 Nos. (c) UL Listed intelligent heat detector -04 Nos (d) Manual call point - 20 Nos. (e) Audio visual indication of smoke or fire-20 Nos. (f) zone Monitor module (g) Fault isolator - 30 Nos (h) Wall mounted hooter - 20 Nos (j) Response indicator -100 Nos (k) IR Flame detector (l) UPS 500 VA | |||||
| 4.00 | Repair, comprehensive and preventive maintenance of CO2 flooding system in ROH flight (One nos two zone panel, 8 Nos CO2 Cylinder and 01 Nos N2 Cylinder) as per manufacturers reccomendation which includes the following operations as under :- (i) Checking and cleaning of smoke/ heat detectors ,nozzles/Co2 pipe line etc complete all as specified & directed. (ii) Checking of main control panel and control wiring complete all as specified and directed. (iii) Weighing of CO2 /N2 cylinders complete all as specified and directed.
Note :(a) If any defect notice/found ,the same should be rectify immediatly and report to Engr-in-charge. (b) Spares shall be measured and paid separately under relavent item of schedule. If defect not rectified by contractor with in stipulated period as directed by Engr-in-charg then penality @ ₹ 500/per day will be recover from RAR /BILL. Testing of the entirefire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge. | 9 | Each Job | 4,000 ₹36,000 | 2,900 ₹26,100 |
| 5.00 | Supply & Fix in replacement intelligent Analogue addressable multicriteria type heat with smoke detector with base. (Bearing Lab & H-19). Make shall be as per site requirement of existing make compatible with main fire alarm panel Make : Honeywell / Siemens | 230 | EACH | 4,000 ₹9,20,000 | 2,400 ₹5,52,000 |
| 6.00 | Supply only of Intransically Safe Conventional Photoelectric Smoke Detector UL/FM/LPC approved with junction box and base complete to be fixed inside test rig with suitable fixing arrangement complete all as specified and directed. Make Apollo model Orbis cat part No ORB-OP-52027-APO/ Systen senser cat part No JTY-GD-2151 EIS or equivalent make in Hochiki / BOSCH. | 5 | Each | 2,000 ₹10,000 | 2,200 ₹11,000 |
| 7.00 | Supply only of Intransically safe Conventional heat detector class AIR, UL / FM / LPC approved with base complete all as specified and directed. Make Apollo Model Orbis cat part No ORB-HT-51145-APO / Systen senser cat part No JTWB-BCD-5151EIS or equivalent make in Hochiki / BOSCH | 5 | Each | 2,000 ₹10,000 | 2,100 ₹10,500 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
24 Feb 2026, 6:00 pmClosed
GE(AF)EM Chakeri Kanpur
GE(AF)EM Chakeri Kanpur
COMPREHENSIVE MAINT OF FIRE FIGHTING SYSTEM ALONG WITH DETECTION SYSTEM AND CONNECTED WORK IN TECH AREA AND REPAIR AND COMPREHENSIVE MAINTENANCE TO PNEUMATIC TOOL AIR COMPRESSOR AND ITS CONNECTED ITEMS AT GE(AF) E/M CHAKERI
2026_MES_750081_1
8819/E8
Open Tender
Civil Works
270 days
Area under GE(AF)EM Chakeri Kanpur
As per tender documents
9 documents required · 9 mandatory
₹500
GE(AF)EM Chakeri
₹1 L
Yes
16 May 2026
27 Jan 2026
2 Mar 2026
28 Jan 2026
24 Feb 2026
11 Feb 2026
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.04 MB
Tender_Acceptance_Letter.pdf
Additional Documents • 0.08 MB
Workdetails.pdf
Additional Documents • 0.09 MB
BOQ_840080.xls
BOQ • 0.46 MB
8819E8_Tender_1.pdf
Tender Documents • 0.76 MB
8819E8_CreditSchdule_1.pdf
Additional Documents • 0.21 MB
Download all tender documents and submit your bid