Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹22.4 L+₹1.5 L (7.17%)Rejected-AOC HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L2 | Rejected-AOC Not accepted being L | |
| 3 | L3₹30.9 L+₹10.0 L (47.7%)Rejected-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L3 | Rejected-AOC Not accepted being L3 |
Tender Value
Refer Docs
EMD Value
₹43,220
Closing Date
21 Sept 2021, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PARTAPUR
GE PARTAPUR
VARIOUS REPAIR OR REPLACEMENT OF PIPE LINES WITH CONNECTED ITEMS FOR KHALSAR, SASOMA AND BASE CAMP AND SECURITY LIGHTS OR SOLAR LIGHT FITTING WITH LED FITTINGS INCL OTHER MISC WORKS OF EM INSTLNS AT HUNDER, KHALSAR AND BASE CAMP UNDER GE PARTAPUR
2021_MES_470634_1
GE/P-68/2021-22
Open Tender
Miscellaneous Works
Works
180 days
GE PARTAPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE PARTAPUR
₹43,220
Yes
11 Jan 2022
27 Aug 2021
22 Sept 2021
6 Sept 2021
21 Sept 2021
7 Sept 2021
60 days
Amount
Excavatoin in trenches not exceedng 1.5 mtr wide but exceeding 1.5 mtr in depth for laying of pipe and getting out all in hard and dence soil.
Returning filling in including spreading watering and well ramming in layer not exceeding 25mm thick in hard dence soil
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point.
Taking up / down old DI/GI/PP-R tubing connection including clearing (from trenches) complete as directed by Engr-in-Charge of following size :
(a) 20mm bore
(b) 25mm bore
(c) 40mm bore
(d) 50mm bore
Supply and fixing in replacement of 3-layer PP-R Polypropylene random copolymer concealed piper SDR 7.4 ((PN-16) VU stabilized and antimicrobial dusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings 20 mm outer dia with all fitting laid in trenches or fixed to walls and ceiling or laid in floor complete all as specified and directed by Engr-in-Charge. Make : SFMC or equivalent
All as per srl item No 9 but outer dia 25mm. Make : SFMC or equivalent
All as per srl item No 9 but outer dia 40mm. Make : SFMC or equivalent
All as per srl item No 9 but outer dia 50mm. Make : SFMC or equivalent
M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 20mm outer dia 22/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 0.01mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge.
M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 25mm outer dia 28/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 0.01mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge.
M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 40mm outer dia 28/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 0.01mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge.
M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 50mm outer dia 28/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 0.01mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable gate valve/Ball Valve/Air release valve GI/PPR of size 20/25/40/50 mm bore complete.
Supply and fixing in replacement of PP-R gate valve (brass insert) for 50 mm dia pipe as per requirement of the site all as specified and directed. Make : SFMC/Prince or equivalent.
Supply and fixing in replacement of PP-R ball valve (brass insert) for 40 mm dia pipe as per requirement of the site all as specified and directed. Make : SFMC/Prince or equivalent.
Supply and fixing in replacement of PP-R ball valve (brass insert) for 25 mm dia pipe as per requirement of the site all as specified and directed. Make : SFMC/Prince or equivalent.
Supply and fixing in replacement of PP-R ball valve (brass insert) for 20 mm dia pipe as per requirement of the site all as specified and directed. Make : SFMC/Prince or equivalent.
S&F in replacement of old unserviceable water heating system/Hamam of capacity 300 Ltrs with diesel/kerosene burner of 5 inch with boiler and diesel/kerosene tank Inner sheet made of 10 SWG mild steel sheet and outer sheet shall be made of 16 SWG of mild steel sheet. Glass wool insulatiuon of 25mm thickness to be provided between outer and inner sheet. 100mm dia MS pipes is to be be fitted in centre which will act as heater. One direct water connection for input of water. Funnel for pouring water manually to be provided. One over flow pipe, 3 outputs of hot water from the boiler with bib taps to be provided. Inner chamber is to be painted with boiler paint and external steel surface are to be painted with two coats of synthetic enamel paint over a coat of red oxide incl necessary components like stands for hamam, stand for uell tank and feul pipe for connecting burner, diesel/kerosene tank etc, complete all as specified and directed by Engineer-in-Charge.
All as per srl tiem No 18 here-in-before but of capacity 500 Ltrs.
M&L for Disconnecting carefully the Hamam motor of any capacity and rewinding of copper winding of motor with super enamelled copper wire with existing size and gauge including varnishing, heating and testing, commissioning and reconnecting incld welding of MS part all as required to the entire satisfaction of Engineer-in-Charge and, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Puff insulated PVC water tank of capacity 500 Ltrs including necessary connections to water supply pipe line etc, complete all as specified and as directed by Engr-in-Charge.
Demolishing the old unsv valve chamber and M&L for construction of valve chamber of size 900mm x 900mm x 1500mm in CM 1:6, depth of the chamber to be reckoned from the top of the PCC to top of the MS cover as 1.5 Mtr including MS sheet cover fabricated from 3mm thick MS sheet and frame of angle iron 40mm x 40mm x 6mm with all fixing and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide on MS cover & frame including necessary excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distrance n.exc 50m, including 15mm thick plaster in CM 1:4 (both internally & externally) complete all as specified and directed by Engr-in-Charge.
Supply ,laying & testing GI tubing 50mm bore medium grade conforming to IS : 1239 with all fittings laid in trenches / fixing on walls complete all as specified and directed.
Supply ,laying & testing GI tubing 40mm bore medium grade conforming to IS : 1239 with all fittings laid in trenches/fixing on walls complete all as specified and directed.
Supply,fixing and testing Gun metal gate valve 50 mm ,screwed body ends and cast iron hand wheel conforming to IS 778-1984 complete all as specified and directed.
S&F in replacement of PPR Air release valve of size 40/50 mm complete all as specified and directed by Engr-in-charge
Checking/taking down carefully existing unserviceable security/street light/flood light fitting of any shape and size or capacity by unscrewing from steel tubular pole of 9 mtr long/wall of bldg including unserviceable bracket complete and make it serviceable and refixing the same at its original position (if repairable with minor repair) all as specified and as directed by Engr-in-Charge. Note :- (i) Spares/New fittings shall be measured and paid separetly. (ii) The T&P vehicle and necessary ladder etc will be arranged by the contractor and the cost deemed to be included in the quoted rates.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete making all necessary connection with suitable capacity of 3 core circular cable complete all as specified and directed. Make- CG/Havells/Phillips or equivalent
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete making all necessary connection with suitable capacity of 3 core circular cable complete all as specified and directed.Make- CG/Havells/Phillips or equivalent
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete making all necessary connection with suitable capacity of 3 core circular cable complete all as specified and directed.Make- CG/Havells/Phillips or equivalent
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp making all necessary connection with suitable capacity cable complete all as specified and directed.Make- CG/Havells/Phillips or equivalent
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp making all necessary connection with suitable capacity cable complete all as specified and directed.Make- CG/Havells/Phillips or equivalent
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete : Havells/wipro/CG or equivalent
Supply only LED driver 45 Watt for street light as per existing complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Taking down shall be measured separetly under respective item of BOQ.(ii) Make and model of driver will be as per existing & as per directed by engr-in-charge.
Supply only LED driver 35 Watt for street light as per existing complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Taking down shall be measured separetly under respective item of BOQ.(ii) Make and model of driver will be as per existing & as per directed by engr-in-charge.
Material and labour in replacement of PVC insulated multi stranded aluminum conductor PVC cable weather proof flat twin core cable 2.5 Sqmm and making connection of street light fittings with loop box /OH line complete all as specified and directed by Engr-in-Charge. Make : - Havells/Plaza/Kalinga
Supply and fixing in repair GI bracket for street light made of 40mm bore GI pipe (medium grade of length 1.5 meter), bend to shape including providing flat iron clamp (of suitable size, made out of 40mm x 5mm mild steel flat) with nuts, bolts and washer of suitable size, including applying two coat of red oxide primerand one coat of aluminium paint complete all as specified and directed by Engr-in-Charge.
Supply and erecting and fixing in proper position steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00metres long) Make: Advance steel tube, National tubing co, Mahindra industries, sohan lal and sons,Sidhartha all as specified and as directed. Note: (i) Excavation ,earth work and PCC shall be measured and paid separately. (ii) Painting will be measured and paid seperately under relevent item.
Material & Labour for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole/stay and filling of mass concrete including providing necessary form work complete all as specified and as directed by the Engineer-in-charge
Material & Labour for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in coping of pole including providing necessary form work complete all as specified and as directed by the Engineer-in-charge
Material and labour for Cleaning and preparation of old surface of street light steel tublar pole and painting by applying two coats of aluminium paint including bracket and alternative black and Yellow strips on pole with synthetic enamel paint upto 1.5 mtr height from top of PCC foundation (each strip 15 cm height) including applying two coats of cement base paint to coping complete all as specified and directed.
M & L for servicing the solar street light system complete by checking & cleaning PV Module, battery, charging voltage,discharge voltage, loose contacts & fitting etc including topping up distilled water/electrolite, appling petroleum jelly in terminals. Note: Self supported ladder shall be provided by the contractor for cleaning and checking of SPV module since the normal ladder cannot be used.
S & F in replacement of LED solar DC street light 15 watts (with inbuilt CCU) fitting comprising of epoxy powder coated aluminium housing enclosed with glass cover complete including taking down old fitting of any model Make : LHKTBJU7PA6J015 of Havells or equivalent in Philips/ Crompton Greaves
S&F in replacement of solar panel of 75/80W suitable for 5W solar BP light and 12 V 50/65 AH battery complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Solar street Light charge controller unit, 12V suitable for solar street light. Make:Sun/Exide/Amaron
S&F in replacement of sealed maintenance free battery 12 V 42 AH complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sealed maintenance free battery 12 V 65 AH complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair MS box suitable for placing 50/65AH battery, factory fabricated out of L-Angles and steel sheet 3 mm thick of size 60 cm x 30 cm x 60 cm (approx) complete duly powder coated (ivory) with fixing arrangements on street light pole all as directed.
Material and labour for painting of solar light pole and all structure by smoke grey colour paint in two coat over one coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Supply and fixing Solar LED Standalone street light 15 W, 12V, 1500 lumen alongwith 75WP Solar Panel and 40AH Battery and 6 mtr tube pole with 2 days battery backup including pcc foundation as per specification as specified and directed by Engineer-in- Charge. . Make : Havells/crompton /SYSKA
Material and labour for taking down the 6/7 lantern symmetrically fitted system from High mast light of 9/12 metres height with their control gear system for repairing the LED flood light fittings, LED aviation obstruction lights and shiting to the same position after completion of repair/replacement all as directed and specified. Note : The spares & replacement of LED flood light fittings, LED aviation obstruction lights are measured and paid separately under relevent items.
Supply and fix in repairs LED Aviation Obstruction light fitting 302 LED with all accessories, brackets for fixing arrangements etc., on Hanger. Make: Bajaj, Model: BGAV 302 LED or equivalent in Philips/Crompton Greaves/Havells.
Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of size of 10/16/25 Sq mm 4 core for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge (Note- Excavation and earth work shall be measured and paid separately)
Supply, laying, Jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- sectional area 70 Sqmm 3.5 core confirming to IS7098 of 1995 laid in trench/ducts/pipe/wall or on poles complete as directed and specifed by Engineer-in-Charge. Note : (i) Excavation and earth work will be measured and paid separately under respective items
Supply, laying, Jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- sectional area 25 Sqmm 4 core confirming to IS7098 of 1995 laid in trench/ducts/pipe/wall or on poles complete as directed and specifed by Engineer-in-Charge. Note : (i) Excavation and earth work will be measured and paid separately under respective items
Supply, laying, Jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- sectional area 16 Sqmm 4 core confirming to IS7098 of 1995 laid in trench/ducts/pipe/wall or on poles complete as directed and specifed by Engineer-in-Charge. Note : (i) Excavation and earth work will be measured and paid separately under respective items
Supply, laying, Jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- sectional area 10 Sqmm 4 core confirming to IS 7098 of 1995 laid in trench/ducts/pipe/wall or on poles complete as directed and specifed by Engineer-in-Charge. Note : (i) Excavation and earth work will be measured and paid separately under respective items
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed by Engineer-in-Charge.
Returing, filling in incl spreading, levelling watering and well remming in layers n.exc 25cm width, Complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point Completed all as specified and diercted by Engineer-in-Charge.
Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and directed by Engineer-in-Charge.
M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm Complete all as specified and directed by Engineer-in-Charge.
Supply and laying GI pipe light grade 40 mm bore including all type fitting such as bends, elbows, tee etc fixed on walls/to poles/laid in trenches/boring as cable protection.
M&L for manual horizontal boring upto 1.5 mtr below the ground level 80 mm dia for road crossing with out disturbing the existing road/pcc,getting out and disposal of soil to distance not exceeding 50mtr from the site of work complete all as specified and directed by engr-in-charge.
Supply and fixing Aluminium bus bar chamber 3 phase, 200 Amp capacity with 4 nos Al strips not less than 600 mm long, outdoor type including one MCCB of 125 Amps 4 Pole as incommer with locking arangement, grouting in pcc 1:3:6 and connecting with UG XLPE cable with suitable copper thimbles complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x60mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron wire 4 mm dia by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x60mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron earth strip of size 32 x 6 mm thick by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip.
M&L for cement concrete in foundation, filling and mass concrete type B1 1:2:4 using 20mm graded stone aggregate for LT panel board/poles foundation.
RND ENGINEERS & CONTRACTORS
EESSI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .