OFFICE OF THE EXECUTIVE ENGINEER STD DODA
OFFICE OF THE EXECUTIVE ENGINEER STD DODA
CREATION OF RECEIVING STATION
2024_PDD_259940_1
STD/Doda/capex/13 of 2024-25
Open Tender
Electrical Works
365 days
CHATROO
KINDLY REFER TO SBD
2 documents required · 2 mandatory
₹4,000
Yes
OFFICE OF THE EXECUTIVE ENGINEER STD DODA
₹11.2 L
7 Nov 2024
15 Oct 2024
30 Oct 2024
15 Oct 2024
28 Oct 2024
15 Oct 2024
15 Oct 2024 - 19 Oct 2024
A-SUPPLY PART
SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY
33 KV VCB (36 KV, 1250 A, 26.2 KA, outdoor type)
33 KV Isolator without earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA)
33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase
30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless
33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port
33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm
STEEL STRUCTURES
Pipe Nominal bore 200, 5.9 mm thick
Galvanised steel structures
Galvanized nuts and bolts
CONTROL CABLES
12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS
6 core 2.5 mm2 copper armoured, 1.1 kv grade, ISI FRLS
2 core 2.5 mm2 copper armoured, 1.1 kv grade, ISI FRLS
Lugs & Ferrules etc.
CONDUCTOR AND HARDWARE
ACSR Conductor Panther
T-Clamp
Single Tension fitting
Polymer Composit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load 70 KN
Earth Wire 7/4 sqmm
G.I Flat 50*6 mm
33/11 KV, 6.30 MVA Power Transformer
33/11KV ONAN,Copper wound,outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars
12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS
6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS
2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS
Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme)
11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector meter-5A,DLMS Compliant with RS-485 Port 1 Incoming & 4 outgoings
11KV Gapless Surge Arrestor,9KV,10KA LA With polymer Housing Station Type
11KV (UE) XLPE Power Cable 3 core armoured
II. 400mm square three core
II. 120mm square three core
11KV Heat shrink termination Cable Kits (Indoor) 400 mm square (3-core)
11KV Heat shrink termination Cable Kits (Outdoor) 400 mm square (3-core)
11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core)
11KV Heat shrink termination Cable Kits (Outdoor) 120 mm square (one spare) (3-core)
11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch
11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps.
100 KVA, 11/.433 KV, Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound.
St Poles 9 mtrs long
Galvanised iron of sorts
120 mm2 PVC 4 core cable,Armoured FRLS
MCCB 200 Amp
Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole
Earthing of 100 KVA Sub structure As per Standard
Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long
COMMON MISCELLANEOUS EQUIPMENTS
a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand
b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply.
Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supply with 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories
Distribution panel (415 V, AC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories.
Telecommunication facilities includind cctvs set (4nos cameras ) LED Display (32")
Civil Works
Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height
Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height.
33/11kv power Transformer Foundation
33kv Equipment Foundation and gantry foundation
Earthing Mat complete job GI flat 50x8 mm
Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips
33kv Yard Concreting / Metalling
Water tank 1000 Ltrs.( overhead)
Control room Building including with internal wiring and fixing of electrical appliances like lights ,fans,geysers job
Shift Quarters for Je and SBA including internal wiring complete and fixing of electrical appliances like lights ,fans,geysers job
Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing
Bore Well with submersible
Development of land (2 Kannal 10 Marla) by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain.
Yard Lighting ( 4 Nos yard and 02 Nos CR back side)
SINGLE BUS OUT AT R/STN DADPATH
33 KV VCB (36 KV, 1250 A, 26.2 KA, outdoor type)
33 KV Isolator with earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA)
33 KV Current Transformer (Single Phase,Multi ratio,multi core ,Outdoor)
30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless
33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 PHASE Trivector meter DLMS compliant RS 485 port
33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm
33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase)
STEEL STRUCTURES
Pipe Nominal bore 200, 5.9 mm thick
Galvanised steel structures
Galvanized nuts and bolts
CONTROL CABLES
10 /12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS
8 core 2.5 mm2 copper armoured, 1.1 kv grade, ISI FRLS
2 core 2.5 mm2 copper armoured, 1.1 kv grade, ISI FRLS
Lugs & Ferrules etc.
CONDUCTOR AND HARDWARE
ACSR Conductor Panther
T-Clamp
Single Tension fitting
Polymer Composit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load 70 KN
Earth Wire 7/4 sqmm
G.I Flat 50*06 mm
ERECTION OF 33 KV LINE FROM RECEIVING STATION DADPATH
11 Mtr. Long ST Pole(For new line) ST-410 SP56
GI Channel X-arm including clamps and braces
100 mm² ACSR Dog Conductor
PG Clamps for 100 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .6cum /pole
Stone Pad (300 mm x 300 mm x 75 mm)
Aluminium Jointing Sleeves
Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete
33 KV Isolator with earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA)
Guard netting
SAFETY ITEMS
Rubber Mat 1m*2m (19mm thick)
Fire Extinguisher CO2 type of 4.5 Kg capacity for control room
3-Sand Bucket Fire Extinguisher
Helmet
Rubber Gloves for 33 KV Level
Rubber Gloves for 11 KV Level
Safety Belt
Safety Shoes
Earthing rod (set of 3 rods)
HV Detector all Voltages
SPARE ITEMS (TO BE SUPPLIED TO DIVISIONAL STORES )
Aluminium Ladder Sliding type 30 feet Long
Lifting and Puling machine 5 Ton
Come along Ratchet Upto Wolf Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
B- ERECTION PART
SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY
33 KV VCB (36 KV, 1250 A, 26.2 KA, outdoor type)
33 KV Isolator without earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA)
33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase
30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless
33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port
33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm
STEEL STRUCTURES
Pipe Nominal bore 200, 5.9 mm thick
Galvanised steel structures
Galvanized nuts and bolts
CONTROL CABLES
12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS
6 core 2.5 mm2 copper armoured, 1.1 kv grade, ISI FRLS
2 core 2.5 mm2 copper armoured, 1.1 kv grade, ISI FRLS
Lugs & Ferrules etc.
CONDUCTOR AND HARDWARE
ACSR Conductor Panther
T-Clamp
Single Tension fitting
Polymer Composit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load 70 KN
Earth Wire 7/4 sqmm
G.I Flat 50*6 mm
33/11 KV, 6.30 MVA Power Transformer
33/11KV ONAN,Copper wound,outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections
12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS
6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS
2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS
Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme)
11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector meter-5A,DLMS Compliant with RS-485 Port 1 Incoming & 4 outgoings
11KV Gapless Surge Arrestor,9KV,10KA LA With polymer Housing Station Type
11KV (UE) XLPE Power Cable 3 core armoured
II. 400mm square three core
II. 120mm square three core
11KV Heat shrink termination Cable Kits (Indoor) 400 mm square (3-core)
11KV Heat shrink termination Cable Kits (Outdoor) 400 mm square (3-core)
11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core)
11KV Heat shrink termination Cable Kits (Outdoor) 120 mm square (one spare) (3-core)
11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch
11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps.
100 KVA, 11/.433 KV, Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound.
St Poles 9 mtrs long
Galvanised iron of sorts
120 mm2 PVC 4 core cable,Armoured FRLS
MCCB 200 Amp
Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole
Earthing of 100 KVA Sub structure As per Standard
Earthing complete GI pipe 400 mm or GI rod 20mm 2.5 mtr long
COMMON MISCELLANEOUS EQUIPMENTS
a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand
b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply.
Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supply with 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories
Distribution panel (415 V, AC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories.
Telecommunication facilities
Civil Works
Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height
Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height.
33/11kv power Transformer Foundation
33kv Equipment Foundation and gantry foundation
Earthing Mat complete job GI flat 50x8 mm
Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips
33kv Yard Concreting / Metalling
Water tank 1000 Ltrs.( overhead)
Control room Building including with internal wiring and fixing of electrical appliances like lights ,fans,geysers job complete job
Shift Quarters for Je and SBA including internal wiring and fixing of electrical appliances like lights ,fans,geysers job complete job
Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing
Bore Well with submersible
Development of land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain.
Yard Lighting ( 4 Nos yard and 02 Nos CR back side)
SINGLE BUS OUT AT R/STN DADPATH
33 KV VCB (36 KV, 1250 A, 26.2 KA, outdoor type)
33 KV Isolator with earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA)
33 KV Current Transformer (Single Phase,Multi ratio,multi core ,Outdoor)
30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless
33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 PHASE Trivector meter DLMS compliant RS 485 port
33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm
33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase)
STEEL STRUCTURES
Pipe Nominal bore 200, 5.9 mm thick
Galvanised steel structures
Galvanized nuts and bolts
CONTROL CABLES
10 /12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS
8 core 2.5 mm2 copper armoured, 1.1 kv grade, ISI FRLS
2 core 2.5 mm2 copper armoured, 1.1 kv grade, ISI FRLS
Lugs & Ferrules etc.
CONDUCTOR AND HARDWARE
ACSR Conductor Panther
T-Clamp
Single Tension fitting
Polymer Composit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load 70 KN
Earth Wire 7/4 sqmm
G.I Flat 50*06 mm
ERECTION OF 33 KV LINE FROM RECEIVING STATION DADPATH
11 Mtr. Long ST Pole(For new line) ST-410 SP56
GI Channel X-arm including clamps and braces
100 mm² ACSR Dog Conductor
PG Clamps for 100 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm With fittings
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .6cum /pole
Stone Pad (300 mm x 300 mm x 75 mm)
Aluminium Jointing Sleeves
Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete
33 KV Isolator with earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA)
Guard netting
GUARDIAN ENGINEERS (BID ID -2194106)
JK Electric Engineers Pvt. Ltd. (BID ID -2192740)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid