Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹40.1 L+₹1.6 L (4.25%)Rejected-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹40.2 L+₹1.7 L (4.42%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹42.6 L+₹4.1 L (10.8%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹43.2 L+₹4.7 L (12.3%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
17 Jun 2024, 6:00 pmClosed
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE (N) P/T- 118 OF 23-24REP AND MAINT OF LT UG CABLE CONTROLS LT DISTR NETK AND CONNE ITEMS LT PANELS AT VICTORIA RD GHORPADI LINE KOHIMA KG LINE 41 ARTY DIV 101 TA BN CMP NIRMAN VIHAR SHANTI VIHAR AFMSD ETC IN AGE E/M (N) UNDER GE (N) PUNE
2024_MES_656394_1
GE (N) P/TOKEN- 118 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹96,000
Yes
19 Feb 2025
28 May 2024
24 Jun 2024
28 May 2024
17 Jun 2024
12 Jun 2024
29 May 2024 - 4 Jun 2024
Amount
Taking down old unserviceable feeder pillar box of any type, Supply, fixing, testing and commissioning of LT feeder pillar panel double door floor mounted outdoor type, as per IP-65 grade, made out of CRCA sheet 3.00 mm thick of outer body and 2 mm of internal thickness of suitable size with aluminium bus bar 600 Amps, 4 strip (3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands, Nuts & Bolts, Washers complete with comprising of following and including: -
Incoming
(a) MCCB, 4 Pole, 415 Volts, 350 Amp, adjustable Thermal Magnetic relay with breaking capacity 36 KA at 415 volts Ics=100% Icu -01 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(d) Indicator lamp LED type (R,Y,B) complete with bakalite fuse fitting - 01 Set
Outgoing
(b) MCCB 3 pole, 100 Amp, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 04 Nos Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(b) MCCB 3 pole, 63 Amp, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 04 Nos Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(c) Automatic astronomical type timer switch with switches ON/OFF the street lights base on lux level of natural light current rating 32/40 Amps, 220 Volts, 50 Hz. The sensor based timer should also have over voltage and low voltage trip with auto reset facility the sensor alongwith suitable power contactor, MCB and support terminals should be enclosed-1 No
(d) Provision for space to be kept blank for fixing of MCCB - 01 No
Note :- Installation, testing, commissioning and connecting of incoming and outgoing cables connections LT feeder pillar panel is included in rates quoted. All fixing material like thimble, Glands, Nuts & Bolts are included in unit rate. Earthing strip to be connected with feeder pillar box with suitable size Nuts & Bolts.
Note :-Makes of LT Panels / LT Feeder Pillar Boxes are given below Item No 1 to 6
M/s Legrand India Pvt ltd
M/s Standard
M/s Sombasi Envro Engg Pvt Ltd
M/s C & S Electric Ltd
M/s Neptune System Pvt Ltd
M/s BCH Electric limited
Taking down old unserviceable feeder pillar box of any type, Supply, fixing, testing and commissioning of LT feeder pillar panel double door floor mounted outdoor type, as per IP-65 grade, made out of CRCA sheet 3.00 mm thick of outer body and 2 mm of internal thickness of suitable size with aluminium bus bar 400 Amps, 4 strip (3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands, Nuts & Bolts, Washers complete with comprising of following and including: -
Incoming
(a) MCCB, 4 Pole, 415 Volts, 250 Amp, adjustable Thermal Magnetic relay with breaking capacity 36 KA at 415 volts Ics=100% Icu -01 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(d) Indicator lamp LED type (R,Y,B) complete with bakalite fuse fitting - 01 Set
Outgoing
(b) MCCB 3 pole, 63 Amp, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 01 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(c) MCB 40 Amps, DP, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 10 Nos
(d) Provision for space to be kept blank for fixing of MCCB - 01 No
Note :- Installation, testing, commissioning and connecting of incoming and outgoing cables connections LT feeder pillar panel is included in rates quoted. All fixing material like thimble, Glands, Nuts & Bolts are included in unit rate. Earthing strip to be connected with feeder pillar box with suitable size Nuts & Bolts.
Taking down old unserviceable feeder pillar box of any type, Supply, fixing, testing and commissioning of LT feeder pillar panel double door floor mounted outdoor type, as per IP-65 grade, made out of CRCA sheet 3.00 mm thick of outer body and 2 mm of internal thickness of suitable size with aluminium bus bar 400 Amps, 4 strip (3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands, Nuts & Bolts, Washers complete with comprising of following and including: -
Incoming
(a) MCCB, 4 Pole, 415 Volts, 250 Amp, adjustable Thermal Magnetic relay with breaking capacity 36 KA at 415 volts Ics=100% Icu -01 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(d) Indicator lamp LED type (R,Y,B) complete with bakalite fuse fitting - 01 Set
Outgoing
(b) MCCB 3 pole, 63 Amp, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 06 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(c) MCB 40 Amps, DP, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 10 Nos
(d) Provision for space to be kept blank for fixing of MCCB - 01 No
Note :- Installation, testing, commissioning and connecting of incoming and outgoing cables connections LT feeder pillar panel is included in rates quoted. All fixing material like thimble, Glands, Nuts & Bolts are included in unit rate. Earthing strip to be connected with feeder pillar box with suitable size Nuts & Bolts.
Taking down old unserviceable feeder pillar box of any type, Supply, fixing, testing and commissioning of LT feeder pillar panel double door floor mounted outdoor type, as per IP-65 grade, made out of CRCA sheet 3.00 mm thick of outer body and 2 mm of internal thickness of suitable size with aluminium bus bar 600 Amps, 4 strip (3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking, shouldhave danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands, Nuts & Bolts, Washers complete with comprising of following and including: -
Incoming
(a) MCCB, 4 Pole, 415 Volts, 400 Amp, adjustable type Thermal Magnetic relay with breaking capacity 36 KA at 415 volts Ics=100% Icu -01 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(d) Indicator lamp LED type (R,Y,B) complete with bakalite fuse fitting - 01 Set
Outgoing
(b) MCCB 3P, 100 Amp, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 02 Nos Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(b) MCCB 3 pole, 63 Amp, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 06 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(c) MCB 40 Amps, DP, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 6 Nos
(c) Provision for space to be kept blank for fixing of MCCB - 01 No
Note :- Installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel is included in rates quoted. All fixing material like thimble, Nuts & Bolts are included in unit rate. Earthing strip to be connected with feeder pillar box with suitable size Nuts & Bolts.
Taking down old unserviceable feeder pillar box of any type, Supply, fixing, testing and commissioning of LT feeder pillar panel double door floor mounted outdoor type, as per IP-65 grade, made out of CRCA sheet 3.00 mm thick of outer body and 2 mm of internal thickness of suitable size with aluminium bus bar 600 Amps, 4 strip (3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking, shouldhave danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands, Nuts & Bolts, Washers complete with comprising of following and including: -
Incoming
(a) MCCB, 4 Pole, 415 Volts, 400 Amp, adjustable type Thermal Magnetic relay with breaking capacity 36 KA at 415 volts Ics=100% Icu -01 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(d) Indicator lamp LED type (R,Y,B) complete with bakalite fuse fitting - 01 Set
Outgoing
(b) MCCB 3P, 200 Amp, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 02 Nos Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(b) MCCB 3 pole, 63 Amp, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 04 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(c) MCB 40 Amps, DP, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 5 Nos
(c) Provision for space to be kept blank for fixing of MCCB - 01 No
Note :- Installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel is included in rates quoted. All fixing material like thimble, Nuts & Bolts are included in unit rate. Earthing strip to be connected with feeder pillar box with suitable size Nuts & Bolts.
Taking down old unserviceable feeder pillar box of any type, Supply, fixing, testing and commissioning of LT feeder pillar panel double door floor mounted outdoor type, as per IP-65 grade, made out of CRCA sheet 3.00 mm thick of outer body and 2 mm of internal thickness of suitable size with aluminium bus bar 600 Amps, 4 strip (3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking, shouldhave danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands, Nuts & Bolts, Washers complete with comprising of following and including: -
Incoming
(a) MCCB, 4 Pole, 415 Volts, 400 Amp, adjustable type Thermal Magnetic relay with breaking capacity 36 KA at 415 volts Ics=100% Icu -01 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(d) Indicator lamp LED type (R,Y,B) complete with bakalite fuse fitting - 01 Set
Outgoing
(b) MCCB 3P, 200 Amp, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 02 Nos Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(b) MCCB 3 pole, 100 Amp, adjustable Thermal Magnetic relay with breaking capacity 16 KA at 415 volts Ics=100% Icu - 03 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
(c) Provision for space to be kept blank for fixing of MCCB - 01 No
Note :- Installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel is included in rates quoted. All fixing material like thimble, Nuts & Bolts are included in unit rate. Earthing strip to be connected with feeder pillar box with suitable size Nuts & Bolts.
NOTE :- Item No 1 to 6 LT Panel Makes are given above (Item No 1) and the same company's Original invoice/test certificate/drawings will only be accepted . No sub letting of panel manufacturing is acceptable fom any partner/local company/Dealer .
Supply, laying and testing in replacement of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 300 Sq mm. complete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
-Ditto- all as per item No 7 above but 3.5 core 240 sqmm
-Ditto- all as per item No 7 above but 3.5 core 185 sqmm
'-Ditto- all as per item No 7 above but 3.5 core 120 sqmm
'-Ditto- all as per item No 7 above but 3.5 core 95 sqmm
'-Ditto- all as per item No 7 above but 3.5 core 70 sqmm
'-Ditto- all as per item No 7 above but 3.5 core 50 sqmm
'-Ditto- all as per item No 7 above but 4 core 35 sqmm
'-Ditto- all as per item No 7 above but 4 core 25 sqmm
-Ditto- all as per item No 7 above but 4 core 16 sqmm
M&L for painting of steel tubular pole including cable protection pipe and all iron parts of 9/11 mtr long pole complete with 2 coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including strips of white and red colour of synthetic enamel paint up to the height of 1.5 mtr from the bottm of the pole complete all as specified and as directed. Make : Nerolac/Asian paint
Supply and lay in trenches /under roads/ crossing or fixed to wall/ pole, GI tubing light grade of size 40mm bore for protection of UG cables complete all as specified and as directed.
All as per Item No. 18 above but 80 mm bore
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
Supply and laying in replacement of 40mm outer dia, double walled corrugated DWCpipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply and laying in replacement of 50mm outer dia, double walled corrugated DWC pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply and laying in replacement of 63mm outer dia, double walled corrugated DWC pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply and laying in replacement of 77mm outer dia, double walled corrugated DWC pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
S&F in replacement of MCCB 400 A with suitable spider asper suitable site ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 350 A with suitable spider asper suitable site ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 250 A with suitable spider asper suitable site ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. .Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 200 A with suitable spider asper suitable site ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 160 A with suitable spider asper suitable site ,3 pole ,25 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 63/100 A with suitable spider asper suitable site, 3 pole ,25 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
Supply and jointing kit in replacement of heat shrinkable straight through joint suitable for LT 1100 volts XLPE cable of size 25 to 50 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Supply and jointing kit in replacement of heat shrinkable straight through joint suitable for LT 1100 volts XLPE cable of size 70 to 120 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Supply and jointing kit in replacement of heat shrinkable straight through joint suitable for LT 1100 volts XLPE cable of size 150 to 185 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Supply and jointing kit in replacement of heat shrinkable straight through joint suitable for LT 1100 volts XLPE cable of size 240 to 300 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Automatic transfer switch 400 A ,4 pole ,36 KA inbuilt in sheet metal enclosure with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. Make : Havells ,Legrand and L & T
Checking the Fault of LT Cable of any size and length at any location with fault detector machine and fixing only straight through cable joint kits any size (LT) and LT UG cable as required length after determining the fault location including earth work at any strata as required depth and width and testing complete all as specified and as directed by Engr- in- charge. Note:- i) Fault detector machine & other equipment shall be arranged by the contractor within 1 hour of complaint received including 24/7. ii) Cable jointing kit and LT UG cables shall be measured and paid seperatly as supply only under relevant item
S&F in replacement of MCCB 160A with suitable spider asper suitable site ,4 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 200A with suitable spider asper suitable site ,4 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 250A with suitable spider asper suitable site ,4 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 350A with suitable spider asper suitable site ,4 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 400A with suitable spider asper suitable site ,4 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 500A with suitable spider asper suitable site ,4 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
S&F in replacement of MCCB 630 A with suitable spider asper suitable site ,4 pole ,50 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric
Supply and fixing in replacement of MCB SP 5 To 32 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) to fixing the external panel complete with connection testing and commissioning all as specified and directed
Supply and fixing in replacement of MCB SPN 32 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) to fixing the external panel complete with connection testing and commissioning all as specified and directed
Supply and fixing in replacement of MCB TPN 63/100 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) to fixing the external panel complete with connection testing and commissioning all as specified and directed
Note : 1. Rerformance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
KESARI AND SONS
AGRAWAL ASSOCIATES
Suchit constructions
Rama Electricals
CHAITANYA WINDWELL
K.K.Enterprises
Adinath Technical Services
Fine-Tech. Electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .