Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹47.0 LAccepted-AOC PATIALA | PATIALA | ₹47.0 L Quoted ₹47.2 L | L-1 | Accepted-AOC L1 |
| 2 | L-2₹48.4 L+₹1.2 L (2.45%)Rejected-Finance | ₹48.4 L+₹1.2 L (2.45%) | L-2 | Rejected-Finance rates are on higher side |
| 3 | L-3₹48.6 L+₹1.4 L (2.87%)Rejected-Finance 137 2 OLD LAL BAGH NEAR PRIMARY VICTORIA SCHOOL PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹48.6 L+₹1.4 L (2.87%) | L-3 | Rejected-Finance rates are on higher side |
Tender Value
Refer Docs
EMD Value
₹47,600
Closing Date
6 Jul 2021, 3:00 pmClosed
Incharge Civil
Verka Head Office
Construction of Mineral Mixture Godown at Cattle Feed Plant Bhattian Khanna for L and C Societies only
2021_Coop_67473_1
PSF/Civil/9454-74
Open Tender
Civil Works - Roads
Item Rate
180 days
Verka Head Office
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹47,600
23 Feb 2023
23 Jun 2021
7 Jul 2021
23 Jun 2021
6 Jul 2021
23 Jun 2021
Amount
Dismantling of existing Brick work/ tile masonry in cement mortar, as per actual site conditions/ requirements, finishing the broken surface to match with the surrounding, removing the debris etc. from site of work to dumping ground/yard Including cutting the reinforcement if any and cleaning & stacking of dismantled bricks and bats for re-use in new work, complete in all respects as directed by the E-in-C..
Earth work in excavation for all type of foundations, trenches, etc. in all kinds of soil where pick-jumper work is not involved and not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent refilling around masonary etc. in 15cms layers with compaction/consolidation, including disposal of all surplus soil as directed, within campus / site.
Earth filling under floors/in plinth with surplus soil excavated from foundations (as per above) and taken only from outside the building plinth, in 15cms layers including ramming, watering and consolidating as directed by the Engineer-in-Charge.
Earth filling under floors/in plinth with approved earth brought from outside , in 15cms layers including ramming, watering and consolidating as directed by the Engineer-in-Charge.
Providing and filling in plinth and under floors approved local river sand including carriage loading, unloading, spreading, watering, ramming, consolidating, etc. complete as directed by the Engineer-in-Charge.
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS-6313-2001 (Part-2) & using Chemical containing chloropyrifos systemic insecticide diluted to manufacturer’s specifications i.e. 1 Ltr. of choropyrifos and 19 ltr. water:- (i)In foundation pits, by treating the bottom & sides up to height of 300mm by uniformly spraying solution @ 5 litre per sqm. (ii)In the refill earth on both sides of all built up walls @ 7.5 litre / Running meter (width -300mm, depth -450mm).(iii)Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 litre solution per sqm.
Providing and laying plain cement concrete 1:5:10 using concrete mixture volumetric type with stone aggregate (1 cement: 5 coarse sand: 10 stone aggregate 40mm gauge) for all types of foundations, footings, below rafts, extension columns, plinth beams/under floor etc. including spreading, laying, ramming and consolidating as per requirements and curing etc. but excluding centering and shuttering, complete in all respects as directed by E-in-C
Providing and fixing/placing in position Ribbed/Tor/T.M.T. Steel Bars, for R.C.C. works, where not including in the complete rate of R.C.C. included bending, binding and placing in position as per structural design/ drawing including cost of binding wire. Complete in all respects as directed by the E-in-C.
Providing & laying Reinforced cement concrete M-25 mechanically mixed using batch type concrete mixture as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering, for all types of RCC works i.e. column, footings, strips, pedestals, tie beams & plinth beams etc. as per structural drawings/ design including laying, spreading, ramming, watering, consolidating &curing etc., in foundation and plinth Complete in all respect.
Providing & laying Reinforced cement concrete M-25 mechanically mixed using batch type concrete mixture as per IS 1791 and vibrated by needle vibrator in supper structure but excluding steel reinforcement, centering and shuttering, for all types of RCC works i.e. column, & beams etc. as per structural drawings/ design including laying, spre ading, ramming, watering, consolidating &curing etc., in super structure upto 4 mtr. hieght Complete in all respects.
Providing & laying Reinforced cement concrete M-25 mechanically mixed using batch type concrete mixture as per IS 1791 and vibrated by needle vibrator in supper structure but excluding steel reinforcement, centering and shuttering, for all types of RCC works i.e. column, & beams etc. as per structural drawings/ design including laying, spreading, ramming, watering, consolidating &curing etc., in super structure above 4 mtr height Complete in all respects.
Providing and fixing steel shuttering for faces of concrete foundations, footings, strips, pedestals, foundation beam, plinth beams (vertical, or battering) and columns etc. Complete in all respects as directed by E-in-C.
Providing and fixing steel shuttering for columns (square or rectangular) etc. Upto 4 mtr height Complete in all respects as directed by E-in-C.
Providing and fixing steel shuttering for sides and sofits of beams and lintels etc. Complete in all respects as directed by E-in-C.
Providing and fixing steel shuttering for flat surface such as suspended floors,roofs, landings,chajjas,shelves etc. Complete in all respects as directed by E-in-C.
Providing and fixing steel shuttering for parapet facias and other similar items icluding edges etc. Complete in all respects as directed by E-in-C.
Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof
Providing & constructing Ist Class burnt brick work laid in cement sand mortar 1:6 (1 cement: 6 coarse sand) including scaffolding, watering, curing etc. In foundation and plinth complete in all respects, as directed by the E-in-C.
Providing & constructing Ist Class burnt brick work laid in cement sand mortar 1:6 (1 cement: 6 coarse sand) including scaffolding, watering, curing etc. in super structure complete in all respects, as directed by the E-in-C.
Extra for brick work done where any single storey exceeds 4m in height for any additional ht. of 2 m or part there of.
Providing and laying 40mm thick damp proof course of cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm down) with water proofing compound as per manufacturers specifications, complete in all respects as directed by the E-in-C.
Providing and laying 20mm thick cement plaster in damp proof course 1:3, with two coats of bitumen 80/100 penetration @1.65 kg per sqm, laid hot and sanded, complete in all respects as directed by the E-in-C.
Providing and applying cement plaster in cement sand mortar 1:5 (1cement: 5 fine sand) to the walls, columns etc. including providing groove, drip course, scaffolding, finishing, curing etc. Complete in all respects for all heights as directed by the E-in-C.
12.5mm thick for all heights.
20mm thick for all heights.
Providing and applying 10mm thick cement plaster in cement sand mortar 1:3 (1cement: 3 fine sand) to the under side of ceiling. including scaffolding, finishing, curing etc. Complete in all respects for all heights as directed by the E-in-C.
Supplying and fixing rolling shutters of approved make, made of 80mm x 1.25mm M.S. Laths, interlocked together through their entire length, and jointed together, at the end by end locks, mounted on specially designed pipe shaft, with brackets, side guides 27.5 cm long wire spring grade No. 2 and arrangement for inside and outside locking, with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening; where rolling shutter is to be fixed).
Providing and fixing all types of aluminium work for doors/ sliding, etc. windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :
For fixed portion and chawkhats
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Providing and fixing 8mm thick toughned glass in aluminum glazing including the neoprene gasket etc. complete in all respects as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)
Providing and fixing 15mm thick acid and /or alkali resistant tiles 600mmx600mm of approved make ( Johnson/Kajaria or equivalent ) and shade in flooring , laid on 20mm thick bed bed of cement sand mortar 1:4 ( 1 cement:4 fine sand), the tiles to be laid with 3mm to 4mm gap using spacers and later joints to be grouted with acid / alkali resistance epoxy of desired shade. complete in all respects as driected by E-in-C.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Glosy/Highly Glossfinish/Highlighter/emboss conforming to IS :15622 (thickness to be specified by themanufacture of approved make (Johnson/Kajaria or equivalent ) in all colours,shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) with grey cement slurry@ 3.3kg per sqm, the tiles to laid with 3mm to 4mm gap by using spacers and later these joints to be grouted with epoxy of shade . complete in all respects.
Providing and laying Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing, complete in all respects as driected by E-in-C.
Providing and applying Flush/Ruled/Struck or weathered pointing on tile brick work with cement mortar 1:3 (1 cement :3 fine sand). Complete in all respects.
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Providing and constructing top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16, complete in all respects.
Providing and constructing bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 .Complete in all respects.
Providing and laying cement concrete 1:2:4 gola 10cm. X10cm. concave quadrant along junction of roofs with parapet wall, finished smooth where specially specified, complete in all respects as directed by the E-in-C.
P/F C.I. grating for 100mm dia Rain water pipe , complete in all respects as directed by the E-in-C.
Providing and laying 2’-6’’ wide plinth protection consisting of 2’-3’’ wide brick on edge laid in cement sand mortar 1:4 on 75mm thick cement concrete 1:8:16 and 100mm thick sand filling and cement pointing 1:2 on top including excavation re-filling and disposal of surplus earth within campus. complete in all respects as directed by the E-in-C.
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring light point - controled by one switch, in PVC insulated copper conductor single core FR cable (ISI marked - to the approval of E-in-C) overall 1.5 sq. mm, 1100volts grade.
Wiring Fan point - controled by one switch, in PVC insulated copper conductor single core FR cable (ISI marked - to the approval of E-in-C) overall 1.5 sq. mm, 1100volts grade.
Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FR cable (ISI marked - to the approval of E-in-C) overall 1.5 sq. mm, 1100volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade.
Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch.
S/E of PVC insulated Single Core FRLS copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and errection of pipe or casing.
PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1 sqmm, 1100 Volts grade.
PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1.5 sqmm, 1100 Volts grade.
PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 2.5 sqmm, 1100 Volts grade.
PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 4 sqmm, 1100 Volts grade.
Supplying and erection and testing of following MCB/El MCB isolator etc in the existing MCB distribution board as per PWD general specifications 2010 icluding connections with suitable size of thimbles/lugs including acceseries (Breaking capacity 10 kA, Curve-C) suitable for 240/415 volts 50 cycles AC supply, testing and commissioning etc. complete in all respects as directed by the E-in-c. Make :- Havells/ Legrand/ Schneider or equivelant make.
MCB SP 6to 32Amp.
MCB 32 to 64 Amp.
Supplying and Erection of PVC pipes & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc. complete in all respects.
Heavy gauge PVC conduit pipes 20mm dia
Heavy gauge PVC conduit pipes 25mm dia
Heavy gauge PVC conduit pipes 32mm dia
d )Heavy gauge PVC conduit pipes 40mm dia
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.
Sheet metal double door S.P. & N. distribution board 4 way each
Sheet metal double door S.P. & N. distribution board 8 way each
Sheet metal double door S.P. & N. distribution board 12 way each
Sheet metal double door T.P. & N. distribution board 4 way each
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 15mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).
Bonding to earth with G.I. wire No. 8S.W.G. (4mm dia) in 20mm dia. heavy gauge (1.6 mm thick) welded conduit pipe (on surface) including painting etc.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Wall painting with (bio grade)plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) Generally used in hospital buildings etc Complete as per Specifications.
THE CHIRAG LABOUR AND CONSTRUCTIONS CO OP SOCIETY
ARNOULI CO OP L AND C SOCIETY LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .