Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC BAZAR RAM SUKH DASS FEROZEPUR CITY 152002 PB | FIROZEPUR | PUNJAB | 152002 | L1 | Accepted-AOC Due to lowest bid | |
| 2 | L2₹22.4 L+₹75,494.90 (3.49%)Rejected-Finance | L2 | Rejected-Finance Due to higher bid | |
| 3 | L3₹23.3 L+₹1.7 L (7.65%)Rejected-Finance OLD PULL MADIYA JAIRAMPUR AZAMGARH AZAMGARH UTTAR PRADESH 276001 | AZAMGARH | UTTAR PRADESH | 276001 | L3 | Rejected-Finance Due to higher bid | |
| 4 | L4₹24.7 L+₹3.1 L (14.2%)Rejected-Finance | L4 | Rejected-Finance Due to higher bid | |
| 5 | L5₹24.7 L+₹3.1 L (14.3%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L5 | Rejected-Finance Due to higher bid |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) FEROZEPUR CANTT
GE (WEST) FEROZEPUR CANTT
MISC REPAIR TO EXTERNAL ELECTRIC SUPPLY AT AD PATTI HUSSAINIWALA AND HARIKE UNDER AGE EM OF GE (WEST) FEROZEPUR CANTT
2024_MES_654928_5
802024/GE-33/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) FEROZEPUR CANTT
₹50,000
Yes
17 Dec 2024
14 Nov 2024
3 Dec 2024
14 Nov 2024
27 Nov 2024
21 Nov 2024
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable aftger laying complete all as specified and directed. Note: Punned thickness shall be measured.
M&L sub class B bricks locally available of size 22 cm x 11.5 cm x 7.5 cm laid dry width wise across the line of cable in trenches for protection of underground cable complete all as specified and directed.
Supply and spreading graded coarse aggregate of nominal size 20mm in outdoor LT sub stations, complete all as specified and directed.
M&L in replacement of 40 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint and including taking down complete all as specified and directed.
M&L in replacement of pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers & one galvanized iron nuts, 100 mm height, 65 mm dia for 1100 Volts grade after dismantling & taking out old unserviceable and complete all as specified and directed.
M&L in replacement of cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape of size as dircted including applying of two coats of Aluminum paint over a coat of red oxide primer complete all as specified and directed.
M&L in replacement MCCB adjustable thermal & fixed magnetic setting type 160 Amps, 4 pole of breaking capacity 25 to 36 KA, 415 Volts after and including taking down of unserviceable one complete all as specified and directed.
M&L in replacement MCCB adjustable thermal & fixed magnetic setting type 250 Amps, 4 pole of breaking capacity 25 to 36 KA, 415 Volts after and including taking down of unserviceable one complete all as specified and directed.
M&L in replacement MCCB adjustable thermal & fixed magnetic setting type 100 Amps, 4 pole of breaking capacity 25 KA, 415 Volts after and including taking down of unserviceable one complete all as specified and directed.
M&L MCCB in replacement of adjustable thermal & fixed magnetic setting type 125 Amps, 4 pole of breaking capacity 25 KA, 415 Volts after and including taking down of unserviceable one complete all as specified and directed.
M&L MCCB in replacement of adjustable thermal & fixed magnetic setting type 63 Amps, 4 pole of breaking capacity 25 KA, 415 Volts after and including taking down of unserviceable one complete all as specified and directed.
S&F in replacement of Changeover Four pole 100 Amps capacity with SS Enclosure handle with door interlock kit fixed on wooden plank complete all as specified and directed.
S&F in replacement of Changeover Four pole 63 Amps capacity with SS Enclosure handle with door interlock kit fixed on wooden plank complete all as specified and directed.
S&F in replacement of 1100 Volts, 16 Sqmm grade heavy duty cable PVC insulated Aluminum strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable circular/flat complete all as specified and directed.
S&F in replacement of 1100 Volts, 10 Sqmm grade heavy duty cable PVC insulated Aluminum strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable circular/flat complete all as specified and directed.
S&F in replacement of 1100 Volts, 6 Sqmm grade heavy duty cable PVC insulated Aluminum strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable circular/flat cpmlete all as specified and directed.
Supply, laying, testing in replacement of underground cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with Aluminum conductor 1100 volts grade cross section area 95 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing in replacement of underground cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with Aluminum conductor 1100 Volts grade cross section area 50 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing in replacement of underground cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with Aluminum conductor 1100 Volts grade cross section area 25 Sqmm 4 core complete all as specified and directed.
Supply, laying, testing in replacement of underground cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with Aluminum conductor 1100 Volts grade cross section area 10 Sqmm 4 core complete all as specified and directed.
Supply, laying, testing in replacement of underground cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with Aluminum conductor 1100 Volts grade cross section area 10 Sqmm 2 core complete all as specified and directed. Note: (for Ser item No. 17 to 24): (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant items.
M&L meggering of cable including cable jointing kit of 1.1 KV (LT) grade for Heat-shrinkabIe straight through after disconnecting from LT Pole/panel as directed, and finding out fault including required earth work, cutting of cable and preparation for jointing of defective portion of cable complete with jointing material and accessories suitable for PVC/XLPE armoured Aluminum stranded conductor cable of size 50/70/95 Sqmm 3.5 core complete all as specified and directed.
M&L meggering of cable including cable jointing kit of 1.1 KV (LT) grade for Heat-shrinkabIe straight through after disconnecting from LT Pole/panel as directed, and finding out fault including required earth work, cutting of cable and preparation for jointing of defective portion of cable complete with jointing material and accessories suitable for PVC/XLPE armoured Aluminum stranded conductor cable of size 25/16/10 Sqmm 3.5 core complete all as specified and directed.
S&F in replacement of outdoor type LT Panel/Feeder pillar by repair of front & rear doors/ shutters, made out of MS/CRCA Sheet 3.15 mm thickness with necessary fabrication work like replacement of hinges, locking knob bending, welding and painting with two coats of synthetic enamel paints over a coat of red oxide matching with existing panel colour as required at site complete all as specified and directed.
Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet (Minimum size 0.4 m x 0.4 m x 0.35 m) with Synthetic enemal paint both side. Base frame of the panel shall be made of angle iron of size 50mm x50mm x 6mm of upto 1/2 meter hight from GL & 1/2 meter for below GL in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates). The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- (i) Epoxy insulated common Aluminum bus bar of capacity 200 Amps TPN each with Color Coding, including Aluminum lugs to connect the cable.
M&L in replacement of XLPE Insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with Aluminum conductor, 11000 Volts, grade cross sectional area 95 Sqmm 3 Core including taking out old cable complete all as specified and directed. Note: Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
S&F in replacement of cable jointing kit for 11000 Volts (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured Aluminum conductor cable of size 95 Sqmm 3 Core complete all as specified and directed.
S&F in replacement of cable jointing kit for 11000 Volts (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured Aluminum conductor cable of size 95 Sqmm complete all as specified and directed.
M&L earthing complete with galvanised steel plate electrodes of size 600mmx600mm and 6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4mm diameter earth lead by means of nuts bolts check nuts & washers of GI with earth strip protected by galvanised iron pipe 15mm bore (Medium grade) for poles/lightening arrestors/GO Switch including connecting to LT overhead lines all as directed including concrete pit with PCC 1:3:6, type C-1, precast RCC 1:2:4, type B-1 cover slab of size 54cmx54cmx50cm thick reinforced with 8mm hard drawn steel wire fabricated weighting exceeding 4 Kg/Sqm with one handle for lifting made out of 8 mm diameter MS bar finnel wiere mesh 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke andsalt in alternate layers including necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completeion including taking down complete as specified and as directed.
Disconnecting and taking down repairable LED type street light fitting of any type and capacity and make from existing 9 meter/11 meter pole for checking to find out the defects cleaning the glass and prefix cover, repair/replacement of spare parts including necessary wiring etc for making the fitting in serviceable condition and refixing in original position, testing etc complete all as specified and directed. Note: Spare parts will be measured and paid for separtely.
Supply only LED driver 240 Volts 50Hz for 40 to 48 Watts LED fittings.
Supply only LED driver 240 Volts 50Hz for 60 to 90 Watts LED fittings.
S&F in replacement of street light pole cable junction box IP-65 with metnic knockouts for cable entry and the box made out of thermal plastic material suitable for 16/25 Sqmm underground cable including clamps bolts, nuts duly painted and MCB SP 6 Amps etc complete all as specified & directed
M&L painting to steel tubular pole with existing paint and including cross arms upto 11 meter long (except planting depth /PCC coping) with including one coat Aluminum paint including preparation of old painted surface & numbering of poles complete all as specified and directed.
M&L painting of LT PCC pole upto 1.5m height from PCC, of synthetic enamel paint over a coat of cement primer with black and white strips with Aluminum paint on pole & numbering of poles complete all as specified and directed.
S&F GI bracket for street light fitting bend to shape made out of GI pipe light grade 40mm bore upto 1.2m long etc complete with MS clamps duly painted with two coat of Aluminum paint with nuts/bolts/washers for fixing arrangement to pole /wall complete all as specified and directed.
S&F GI bracket for street light fitting bend to shape made out of GI pipe light grade 20 mm bore upto 1.2m long etc complete with MS clamps duly painted with two coat of aluminum paint with nuts/bolts/washers for fixing arrangement to pole/wall complete all as specified and directed.
M&L in replacement of wiring for circuit/street light connection with FRLS PVC insulated Copper conductor sigle core cable in surface/recessed in PVC conduit or Pole circuit of suitable size 2x2.5 sqmm+ 1x1.5 Sqmm earth wire as continous earthing complete all as specified and directed. Note: Two run 2.5 Sqmm of cable shall be measured as single run.
Taking down of the unserviceable/defective transformers of capacity 75 KVA (out door/Indoor type) from the existing site located in cantt area after disconnecting the in/out connection, transporting the transformers to workshop/factory for repairs,testing and transporting the same back after repairs and installing, hoisting of transformers on two/four pole structure at height not less than 3 metre, making all electric connections with HT/LT side jumpers and leads including earth connections etc and testing, complete all as specified and directed. Notes: (a) Oil container for collecting old transformer oil will be arranged by the contractor (b) The T&P such as chain pulley, crane for loading, unloading, transporting and for installing and hoisting shall also be arranged by the contractor. (c) Fixing LT coil DPC copper wire/strip of existing size(gauge) grade and in weight complete with insulating material for transformers complete all as specified and directed. (d) Replacement of all LT brass spindles complete , nuts, bolts, washers for transformers of Suitable Capacity complete all as specified and directed. (e) Silica gel breathers assembly filled with silica gel (01 Nos) complete for transformers of capacity complete all as specified and directed.
M&L for opening the top of defective transformer of any make and capacity 75 KVA removing gasket and lifting up the core assembly carefully to check the condition of transformer for repairs, dismantling core lamination to the extent required for taking out defective/ unserviceable coil for check after disconnecting all connections and re-assembling of core lamination to original position after positioning of existing serviceable coil alongwith new coils carefully to check the condition of transformer to ascertain the repairs/replacement of unserviceable parts including cleaning the tank, removing sludge, dirt cleaning the coils of limbs, re-fixing the core assembly and reassembling of transformer after repairs including zinc chromate paint inside , replacement of nuts bolts with washers thimbles etc and connections with aluminium strip and including welding, denting etc and testing the transformer at factory/workshop to the entire satisfaction of Engineer-in-Charge complete all as directed and specified including the following:- (a) Fixing LT coil DPC copper wire/strip of existing size(gauge) grade and in weight complete with insulating material for transformers complete all as specified and directed (b) Replacement of all LT brass spindles complete , nuts, bolts, washers for transformers of Suitable Capacity complete all as specified and directed. (c) Silica gel breathers assembly filled with silica gel (01 Nos) complete for transformers of capacity complete all as specified and directed. Notes: (a) The payments of new coils to be replaced shall be is included in item rate quoted by contractor. (b) Transformer Oil Dehydration and Topping up will be measure and paid Seperately after repair of Transformers Makes: Hindustan/GRI or equivalent in approved makes.
S&F in replacement of LT brass spindles, nuts, bolts, washers for transformers of capacvity 75 KVA to 100 KVA complete all as specified and directed.
S&F in replacement of LT bushing porcelain capacity 75 KVA to 100 KVA complete with gasket set complete all as specified and directed.
S&F in replacement top cover gasket set of 8 mm thicknes ISI marked complete all as specified and directed.
M&L opening, draining of oil, stoppage of leakage, change of gasket set complete HV/LV rods at site as required and refilling of transformer oil of capacity 75 KVA complete all as specified and directed.
S&F in replacement of silica gel breathers assembly filled with silica gel complete for transformers of capacity upto 100 KVA complete all as specified and directed.
S&F in replacement of temperature gauge 0 to 300 degree centgrade for transformers of capacity 75 KVA complete all as specified and directed.
Supply and pouring/ top up of new Transformer oil for Distribution Transformer Oil (as per IS 335) (EHV) of dielectric strenght min 45 KV in company sealed packed drum complete all as specified and directed. Make :- Volvoline , HPCL, MAK, Gulf, Servo or equivalent in approved makes
M&L for Cleaning sprinkled transformer oil, grease and all other foreign materials from external surfaces of transformers of capacity 75 KVA to 100 KVA and preparing the surface to receive paint and applying one coat of synthetic enamel paint (spray painting) including writing MES number and SM number with white paint over black base in letters not less than 10 cms in height complete all as specified and as directed. Note :- Painting shall be carried out at site.
M&L removing old paint by paint removers and painting to existing outer & inner surcface of LT Control Panel of any size by using spray gun with one coat of red oxide and two coat of synthetic enamel paints as per colour code as mentioned below of, complete all as specified and directed. (i) LT Control Panel (Outer & Inner Surface) - Dark Grey Makes (of Paints): Burger/Asian/Nerolac of first quality or equivalent in approved makes
Carrying out servicing/maint of 30 KVA DG set and cleaning including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as specified and directed. Note:- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned below and shall be of as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer
Carrying out servicing/maint of 62.5 KVA DG set and cleaning including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as specified and directed. Note:- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned below and shall be of as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer
Supply only lubrication oil SAE-40 (15 Watts- 40 grade). Makes: Valvoline/HP/Servo/Gulf or equivalent in approved makes
Supply and filling of inhibitor corrosion (Coolant) suitable for radiators of 30 KVA capacity DG set complete all as specified and directed.
Supply only Lub oil filter complete set. Makes: Kirloskar/ Micco/Bosch or equivalent in approved makes
Supply only Diesel filter complete set. Makes: Kirloskar/ Micco/Bosch or equivalent in approved makes
Supply only Air Filter as per sample.
Supply only Hose pipe & Flexible pipe.
Supply only Fan belt for water pump.
Supply only Fan belt for alternator dynamo.
Supply only lead acid battery capacity of 90 AH, 12 Volts for DG sets installed on pump house complete all as specified and directed. Makes:- Exide Express/Amron/Luminous or equivalent in approved makes
S&F in replacement of Battery Charger for Lead acid & Tubular & VRLA-SMF for Battery upto 7 AH to 120 AH, 12 Volts, single Phase AC supply 230 Volts, 50 Hz including all type indicators, showing charging complete all as specified and directed. Makes: Luminous/ Microtek or equivalent in approved makes
S&F in replacement of LED security light fitting 45 Watts 230 Volts AC outdoor type with high pressure die cast Aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Makes:- Cropmton/Havells/Bajaj/Philips or equivalent in approved makes
S&F in replacement of LED Street light fitting 60 Watts 230 Volts AC outdoor type with high pressure die cast Aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete all as specified and directed. Makes:- Cropmton/Havells/Bajaj/Philips or equivalent in approved makes
S&F in replacement of automatic street light switch for automatic swithcing of street light/high mast light (timer switch) for Three Phase Load light. The Digital timer 24 hrs alongwith suitable power contractor as per IEC - 60947-4-1, including incoming & outgoing MCBs, SMC Encloser and support terminal and enclosed in pole/wall mounted factory made PVC enclosure made out of rust proof, shock & termite proof and FRLS grade confirming to IP 54 of capacity 6 KW, Three phase, Contactor rating 32/TP and MCB rating 40 Amps TPN, having facility of manual operation complete all as specified and directed. Makes:- HAVELLS (model - IHXTS03060 or Techno-commercially equivalent in approved makes)
Cleaning /Site clearence of Pump House/Electrical Installation by cutting and removing shrubs, vegetation, grass, bush, weed, trees and saplings of any height up to the ground clearence, around water supply installation complete all as specified and directed. Notes:- i. The rates quoted includes stacking of useful material and dispose off rubbish / useless material up to a distance of 50m out side the periphery of the installation. ii. Pump house area include the complete OHT area, pump house area and connected path way between pump house and OHT.
M&L cement concreted 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation of poles including necessary form work, fair finished to exposed surfaces without using extra cement wherever required complete all as specified and directed.
M&L cement concreted 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation of stay assembly/feeder pillar/LT panel etc including necessary form work, fair finished surfaces without using extra cement complete all as specified and directed.
M&L Cement concreted 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in foundation of electric poles/struts/ etc including necessary form work, fair finished surfaces without using extra cement complete all as specified and directed.
S&F LT Pre-stressed concrete pole 9.00m long of cross section 102 mm x 152 mm at top and 102 mm x 289 mm at bottom class 10 complying with requirement of IS 1678-1978 including painting of poles with two coats of synthetic enamel paint/over a coat of primer in black and white strips upto 1.5 mtr height from top of PCC complete all as specified and directed. Note:- PCC and earth work shall be measured and paid separately
Dehydration/ filtration of transformer oil of existing transformers (outddor/ indoor, step down) at site by means of oil dehydration machine having arrangement for heating to remove the moisture silt/ sludge and wastage removing arrangement etc to make the oil fit for use in accordance with IS-1886 to achieve minimum dielectric strength of 45 KV by continuous process of dehydration complete including testing complete all as specified and directed. Note: Testing machine shall be arranged by Contractor and charges for the same shall deemed inclusive in quoted rate.
M&L Air break gang operated switch, triple pole, mechanically operated, with contacts of ferrous knife and spring loaded moving contact of copper, vertically mounted, (12 insulator type) mounted on insulator and steel frame with operating mechanism in accordance with IS-9921 including 25mm bore medium grade GI pipe to worked from ground level for current rating up to 200 Amps 11000 Volts with locking mechanism, mild steel clamp, nuts, bolts, washers, operating handle with in both OFF and ON position of required size including two coats of Aluminum paint over a coat of red oxide complete all as specified and directed.
M&L lightening arrestor expulsion type for outdoor suitable for 11 KV high tension line complete with all fittings with discharge capacity 65 Kilo Amps, including bracket clamps, nuts, bolts & washers and connection to earth wire & SWG GI wire of 4mm size complete all as specified and directed. Makes: Pactil/Atlas/ Southem insulator/Jaipuria or equivalent in approved makes
M&L for shifting of DG Set upto 30 KVA any by carefully disconnecting from position lifting the DG Set from the existing sub station/plinth ( AD Patti) and shifting to new location ( Ferozepur Cantt Pump House) and refixing at new location and making all the LT side connections and testing complete all as specified and as directed. Notes :- (i) Installation of DG Set, testing and connecting the LT cables, commissioning on load after checking voltage and out put all as specified and directed shall be deemed to be included in quoted rates. (ii) The rate quoted by contractor inculding of Transportation, Chain Pully, Hydra Machine etc.
Shifting of transformer to a distance from AGE E/M West to AD Patti & Harike, including disconneting and necessary connection and testing after shifting complete all as specified and directed.
M&L shed of size 15 feet x 15 feet for DG Set made out of asbestous sheet duly supported by 3" x 1.5" MS Pipe approx 75 feet, and mounted on 80 mm GI Pipe medium grade approx 54 feet ( Hight 13 Feet Each) complete with 1.5" self screw complete all as specified and directed.
S&F in replacement of existing Copper strip 25mm x 3.15 mm with saddles and fixings screws etc for roof conductors and down conductors above ground complete all as specified and directed
M&L of Cooper strip 25mm x 3.15 mm with saddles and fixings screws etc for roof conductors and down conductors above ground complete all as specified and directed
S&F Air termination, Single pointed Copper rod 12mm dia and 300 mm long with base plate welded at bottom of termination rod 10 cm long fabricated out of 25mm x 3 mm thick flat iron along with 9 mm dia fixing fasteners (wooden block) complete all as specified and directed .
Fixing In repair of Air termination,Single pointed Copper rod 12mm dia and 300 mm long with base plate welded at bottom of termination rod 10 cm long fabricated out of 25mm x 3mm thick flat iron along with 9 mm dia fixing fasteners (wooden block) complete all as specified and directed
S&F test point terminal block made out of gun metal or phosphorus bronze size 75mmx 75mmx25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and directed
S&F in replacement test point terminal block made out of gun metal or phosphorus bronze size 75mmx 75mmx25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and directed
M&L earthing complete with Copper plate 60cm×60cm and 3.15mm thick electrode and thick burried directly in ground vertically to a depth not less than 2.25 meter below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to 20mm×3mm Copper strip earthing lead by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC 1:3:6, type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350mmx350mmx50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre both direction charcoal or coke and salt in alternative layers, necessary excavation & earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
M/s Bansi Lal (BID ID -3172851)
ABHISHEK AND COMPANY (BID ID -3174101)
M/s Sudarshan Enterprises (BID ID -3172904)
S S BUILDERS (BID ID -3173856)
M/S Yashpaul Gulati (BID ID -3172975)
M/s Shri Krishna Enterprises (BID ID -3173057)
manoj and company (BID ID -3175140)
B.L. Chaudhri and Co. (BID ID -3172889)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .