| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹27.3 L+₹7,292.50 (0.27%)Rejected-AOC | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 3 | L3₹32.5 L+₹5.2 L (19.3%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L3 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| Sl No | Description | Qty | Unit | Green Ray Technologies L2 | rc enterprises L1 | PSK Enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00 | Periodical maintenance of DG set as per manufacturer recommendation for the following capacity DG sets installed at various locations and various capacity complete all as specified and as directed. | 11 | Per month | 36,000 ₹3,96,000 | 30,400 ₹3,34,400 Lowest | 40,400 ₹4,44,400 |
| 1.01500 KVA = 03 Nos, 400 KVA = 02 Nos, 320 KVA = 02 Nos, 250 KVA = 03 Nos, 200 KVA = 02 Nos, 160 KVA = 03 Nos, 125 KVA = 02 Nos, 100 KVA = 02 Nos, 82.5 KVA = 04 Nos, 62.5 KVA = 08 Nos, 30 KVA = 02 Nos, 21.5 KVA = 02 Nos, 15 KVA = 01 Nos, 12.5 KVA = 01 Nos, 10 KVA = 02 Nos, 7.5 KVA = 02 Nos, 6 KVA = 01 Nos, 4 KVA = 01 Nos and 0.5 KVA = 02 Nos | ||||||
| 2.00 | Periodical maintenance of DG set as per manufacturer recommendation for the following DG sets installed at various locations and various capacity complete all as specified and as directed. | 3 | Once in 3 month | 9,500 ₹28,500 | 7,603 ₹22,809 Lowest | 8,000 ₹24,000 |
| 2.01Portable Genset 500 watts = 02 Nos, IC Engine 50 BHP = 02 Nos, IC Engine 8 BHP = 02 Nos | ||||||
| 2.02Note: Item No. 1 and 2 (a) Checking the fanbelt and adjusting tension. (b) Checking the fuel and oil filter ascertaining its condition. (c) Checking the Air filter and cleaning the Air filter. (d) Checking of FIP performance and oil level. (e) Checking the tappet clearance and maintaining the valve distance. (f) Checking the fuel pump timing and adjusting if required. | ||||||
| 2.03(g) Tightening the base bolt and nuts and mounting bolts and nuts. (h) Checking the coupling bolts and adjustment checking the self starter and dynamo. (j) Checking the battery distilled water level and topping up to the required level. (k) Checking the loose connections if any in the panel board and tightening the same. (l) Checking the anti vibration mounting adjusting the bolt. | ||||||
| 2.04(m) Checking the radiator and radiator hose and arresting small leaks. (n) Service engineer report shall be submitted for every month check about the performance and maintenance of DG sets.if fail the contrator to submit report Rs 1500/- per DG will be recorver from RAR (o) Highly skilled labours and tools for maintenance/ checks repairs /replacement is deemed to be included in the rate quoated by the contractor. (p) Coolant, distilled water shall be measured under relevant items | ||||||
| 2.05(r) Replacement of fuel /Oil/ Air filter shall be measured under relevant items. (s) Replacement of spares shall be measured under relevant items. (t) The tradesmen employed must wear the uniform with name plate with name of contractor, under whom he is working. The amount of Rs.1000/- will be recovered in case of Non-wearing the uniform with name plate. (u) Insurance cover for the Employed people is must and sole responsibility of the contractor. Documentary evidence shall be submitted by the contractor to the department. (v) The amount of Rs. 500/- for each installation will be recovered for Non-greasing of water pump, alternator bearings cleaning of DG set and Non-replacement of fanbelt, radiator hose, diesel pipe and spare parts DG sets etc., (w) Mechanic, Supervisor and Maintenance Engineer must be skilled and must have knowledge of maintenance of DG sets and attending minor and major fault when it arise. | ||||||
| 3.00M&L for serving to Self starter by taking down the existing defective Self starter from Genset of following below voltage any type installed at various installation and replacement of worn out spares like Bendex drive, carbon brush, solinoid coil, Armature including rewinding starter, refixing in same position and testing complete all as specified and as directed. | ||||||
| 3.01 | 12 V Capacity any type. | 3 | Each Job | 7,500 ₹22,500 | 5,400 ₹16,200 Lowest | 7,100 ₹21,300 |
Tender Value
₹33.9 L
EMD Value
₹67,800
Closing Date
20 Oct 2025, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam
REPAIRS OVERHAULING SERVICING WORKS TO DG SETS OF VARIOUS CAPACITIES AND AMF PANELS INSTALLED AT VARIOUS INSTALLATION AND ALLIED WORKS UNDER GEM ARAKKONAM
2025_MES_731117_1
8517E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer M NAS Arakkonam
AS PER NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹67,800
Yes
7 Nov 2025
22 Sept 2025
22 Oct 2025
22 Sept 2025
20 Oct 2025
6 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.38 MB
SummaryPage8517.pdf
Additional Documents • 0.08 MB
BOQ_819712.xls
BOQ • 0.30 MB
NIT8517.pdf
Additional Documents • 0.37 MB
Tenderdocuments8517.pdf
Tender Documents • 0.61 MB
Scheduleofcredit8517.pdf
Additional Documents • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .