Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹19.4 L+₹8,064 (0.42%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹19.6 L+₹23,040 (1.19%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹19.6 L+₹25,344 (1.31%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹22.0 L+₹2.7 L (13.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹61,600
Closing Date
20 Dec 2020, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT
MAINTENANCE AND OPERATION OF ELECTRICAL INSTALLATIONS AT (1ST HORSE) LAL TIKKU KHAD AND D-II ZONE (CHAKKI AREA) UNDER GE (SOUTH) MAMUN
2020_MES_376515_2
GE(S)/M-46/2020-21
Open Tender
Civil Works
Item Rate
285 days
GE SOUTH MAMUN
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SOUTH MAMUN
₹61,600
Yes
7 Jan 2021
5 Dec 2020
22 Dec 2020
5 Dec 2020
20 Dec 2020
8 Dec 2020
Amount
Manning and operation of 11 KV main electric receiving / distribution Sub Stn at (Lal Tikku Khad) round 'O' Clock (24 hrs) and routine maintenance by taking proper precautions,comprising of following;- (a) HT VCB 630 A - 03 Nos. Make - ABB. (b) Ring main unit 800 A - 01 No. Make-ABB. (c) GOD 11 KV 200/400 A - 04 Nos.
Manning and operation of 11 KV main electric receiving / distribution Sub Stn at (1st Horse) round 'O' Clock (24 hrs) and routine maintenance by taking proper precautions, comprising of following;- (a) HT VCB 630 A - 04 Nos. Make - Alstom. (b) HT VCB 630 A - 01 No. Make - Areva. (c) Ring main unit 800 A - 01 No. Make-ABB. (d) GOD 11 KV 200/400 A - 08 Nos.
Manning and operation of 11 KV main electric receiving / distribution Sub Stn at (D-II Zone at Chakki Area) round 'O' Clock (24 hrs) and routine maintenance by taking proper precautions, comprising of following;- (a) Metal Clad SF6 Switch Gear indoor type HT VCB 400/630 A - 01 No. Make - Crompton Greaves. (b) GOD 11 KV 200/400 A - 02 Nos.
Notes for Srl item No 01 to 03 above required for each Sub Stn 1. Operating staff required for item No. 01 & 02 as under :- (a) Electrician - 03 Nos. (b) Helper for Electrician - 03 Nos. 2. Operting staff required for item No. 03 as under :- (a) Electrician - 02 Nos. (b) Helper for Electrician - 02 Nos.
3. Nature of work involved :- (a) Periodical inspection and maintenance of records thereof. (b) Periodical checking of earthing of HT Panels, GODs and maintaining records thereof. (c) Operations of GODs and replacement of GOD fuses if required. (d) Operations of HT VCB's, GODs, battery bank and relays etc. (e) Maintaining of daily log sheet and record of Sub Stn (f) 3 Shifts timing for shift duty (including reliever as required) 0600 hrs to 1400 hrs (Ist Shift) 1400 hrs to 2200 hrs (2nd Shift) 2200 hrs to 0600 hrs (3rd Shift)
Qualification of Electrician :- Diploma holder in Electrical Engineering or ITI in electrician trade with 2 years experience in operating/ maintaining of HT Panel/ machineries.
Contractor's staff should politely attend tele No. if any and lodged electric complaints in complaint register and attend/ rectified forhwith and submit daily at 08:30 hrs to JE incharge for distribution of complaints
Contractor shall also be responsible for the following :- (a) To carryout cleaning of Sub Stn building inside/outside area by cutting/removing seasonal grass, bushes etc and keep installations daily in presentable condition. (b) Maintain daily log sheet hour wise duly completed in all respect and shall be deposited in AGE E/M office at the end of every month. (c) Contractor shall provide all the assistance and all necessary tools in three sets in eachinstallations i.e (HT/LT Megger to detect of HT/LT fault, combination plier, Nose plier, screw driver set, wire cutter, drilling equipment, hexa, hammer & measuring tape 15RM length etc.) search lights and Ladder suitable for HT/LT overhead lines, required for proper maintenance of Sub Stn which is deemed to be included in quoted rates, attending the rectification of break down of OH lines in HT/LT feeder complete area including replacement of blown out HT/LT fuses. (d) Attending and rectification of break down of HT receiving lines/distribution HT/LT feeder in respective area including replacement of blown out HT/LT fuses. The materials required for maintenance will be provided by Deptt as per nature of complaint. (e) Contractor shall submit the educational qualification document, experience certificate, residential and police verification before employing the staff.
SATISH AND CO
Standard engineers
AGGARWAL ASSOCIATES
M/S J N TRADERS
Ashoka Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .