Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC H NO 959 SECTOR 3 ROHTAK | L1 | Accepted-AOC accepted | |
| 2 | L2₹3.8 L+₹1.5 L (62.0%)Rejected-AOC | L2 | Rejected-AOC rejected |
Tender Value
₹2.1 L
EMD Value
₹4,240
Closing Date
26 Mar 2024, 5:00 pmClosed
VISHWNATH KHICHI
ED - Rohtak
Provision of copper wiring alongwith suitable control and earthing arrangement has made in this estimate
2024_HRY_368413_1
20245BF05998 F48A 459B 864F 702310E3C5B7667BAR
Open Tender
Electrical Works
Works
365 days
Rohtak
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹500
₹4,240
Yes
5 Jul 2024
14 Mar 2024
27 Mar 2024
14 Mar 2024
26 Mar 2024
14 Mar 2024
Amount
HSR Items
[23.1.5.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 5.2. Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group B
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[23.8.1.12]FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size.
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.
[20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm)
[23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)
[23.22.4.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.3. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing)
[23.22.3.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.2. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
[23.22.1.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.1. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Double pole MCCB 16 to 63 Amp, 25 Ka
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[23.6.6.2]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia.
[23.1.4.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 4.2. Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group B
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
[23.1.1.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B
[23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm)
[20.71.2]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 2. 56" (1400mm)
[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.
[23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)
[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE
NS Items
Supply and erection of underground cable loose in existing pipe or trenches complete in all respect upto the entire satisfaction of Engineer in charge of the work. i) 16 Sqmm 4 Core Ard Cable Make: - Havells / Polycab / RR / KEI
Supply and erection of M.S. Box made of 16 Gauge of size d 8` x 10` x 4` covered with 3 mm thick bakelite sheet white colour of ISI Mark fixed by means of 4 Nos. brass screws with cost of 1 No. 15 Amp. multi socket of ISI Mark and 15 Amp. switch and 3 Nos. 5 Amp. multi-socket with 5 Amp. switches of ISI Mark including fixing the M.S. Box in wall with cost of cement sand mixture including painting of M.S. Box and to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of the work.
Supply and erection of LED Tube Light fitting with all accessories and material required to complete the job in all respect and upto entire satisfaction of the Engineer-in-charge of work. 20 Watt LED Fitting Make of Phillips / Wipro / Havells / Crompton / Bajaj
Supply and erection of LED Tube Light fitting with all accessories and material required to complete the job in all respect and upto entire satisfaction of the Engineer-in-charge of work. 40 Watt LED Tube Fitting Make of Phillips / Wipro / Havells / Crompton / Bajaj
Jitender
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .