| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC 79 B BLOCK SRI GANGANAGAR 335001 RAJASTHAN | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹22.4 L+₹3.6 L (19.1%)Rejected-Finance 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹23.3 L+₹4.5 L (24.0%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹23.9 L+₹5.1 L (26.8%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹29.9 L+₹11.0 L (58.6%)Rejected-Finance | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
24 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIRS AND MAINTENANCE OF AC, REFRIGERATORS AND DEEP FREEZERS AT ZONE A,B AND D AT LALGARH JATTAN MIL STN
2023_MES_591488_1
8934-07/GE/23-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Lalgarh Jattan
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹76,000
Yes
4 Jul 2023
26 Apr 2023
26 May 2023
26 Apr 2023
24 May 2023
10 May 2023
Amount
Taking out the unserviceable compressor from Window/Split type AC of capacity 1.5 Ton of any make/model and supply and fixing sealed compressor of same capacity and same model obtained from the factory out let/authorised dealer alongwith test certificate with one year guarantee card, soldering the copper pipes, replacement of capillary tube and dryer filter, replacement of foundation rubber pads , nut and bolts and testing on full load complete all as specified and as directed by Engineer-in-Charge. Make :- Kirloskar/Copeland/Tecumseh/Carrier Note :- (i) Gas charging and gas shall be paid and measured separately under appropriate item of this Sch and cost of cappilary tube and dryer filter shall be deemed to be inclusive in the quoted rates of this item.
All as per item No 1 here-in-before but air conditioner window/split type 2 ton capacity.
Servicing of window/split type AC of capacity 1.5/2.0 tons complete with water washing, filter cleaning, cleaning of condensor tubes, cleaning of cooling coil of evaporator, lubrication of fan motor etc complete all as specified and as directed by Engr-in-Charge
Supplya and fixing in replacement power circuit plate/Board (PCB) of window/split type AC of capacity 1.5/2.0 tons and testing complete all as specified and as directed by Engr-in-Charge. Make: Voltas/LG/Carrier or approved make of OEM.
Shifting of split type AC of capacity 1.5/2.0 tons including dismantling from position, transportation to new location, installing indoor and out door unit at the new locations, grouting/fixing with nut/bolts, connecting up and soldering of pipes, making all electric connections, checking for gas leaks and testing complete all as specified and as directed by Engineer-in-Charge
Shifting of window type AC of capacity 1.5/2.0 tons including dismantling from position, transportation and fixing at new location including making the suitable window in wall/window at new location , making good to the disturbed portion to the existing specification with necessary plastering painting etc. and making the window air tight with suitable material complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement starting relay assembly complete for window/split type AC of any make/model and capacity upto 2 Ton including making necessary connections and testing complete all as specified and as directed by Engineer-in-Charge. Make :- Ranutrol/Anupurna/ Kirlosker/Danfoss
Supply and fixing in replacement thermostat temperature switch suitable for window/split type AC of any make/model and capacity upto 2Ton including making necessary connections and testing complete all as specified and as directed by Engineer-in-Charge. Make :- Indfos/Ranutrol/Anupurna
Supply and fixing in replacement Starting capacitor 100-120 mfd oil filled, 230volt, suitable for window/split type AC of any make/model and capacity upto 2Ton including making necessary connections and testing complete all as specified and as directed by Engineer-in-Charge. Make: TIBCAP/EPCOS/Usha
Supply and fixing in replacement of fan motor 185 watt, copper wound, single phase 240 Volts AC supply, suitable for window type AC of any make/model and capacity upto 2Ton including making necessary connections complete all as specified and as directed by Engineer-in-Charge. Make :- Usha/Crompton/Cool home/polar
Supply and fixing in replacement of fan motor 150 watt, copper wound, single phase 240 Volts AC supply, suitable for outdoor unit of split type AC of any make/model and capacity upto 2 Ton including making necessary connections complete all as specified and as directed by Engineer-in-Charge. Make :- Usha/Crompton/Cool home/polar
Supply and fixing in replacement of AC indoor blower fan motor 50 watt, copper wound, single phase 240 Volts AC supply, suitable for Indoor unit of split type AC of any make/model and capacity upto 2 Ton including making necessary connections complete all as specified and as directed by Engineer-in-Charge. Make :- Usha/Crompton/Cool home/polar
Supply and fixing in replacement of swing blade motor 5/10 watt, copper wound, single phase 240 Volts AC supply, suitable for indoor unit of split type AC of any make/model and capacity upto 2 Ton including making necessary connections complete all as specified and as directed by Engineer-in-Charge Make :- Usha/Crompton/Cool home/polar
Supply and fixing in replacement of blower fan upto 33 Inches, suitable for indoor unit of split type AC and capacity upto 2 Ton including making necessary connections complete all as specified and as directed by Engineer-in-Charge . Make :- Usha/Crompton/Cool home/polar
Supply and fixing in replacement of swing blades, suitable for indoor unit of split type AC and capacity upto 2 Ton including making necessary connections complete all as specified and as directed by Engineer-in-Charge .Make :- LG/SAMSUNG/CARREIR/LLOYD/HITACHI/VOLTAS
Supply and fixing in replacement of blower fan bush, suitable for indoor unit of split type AC and capacity upto 2 Ton including making necessary connections complete all as specified and as directed by Engineer-in-Charge .Make :- LG/SAMSUNG/CARREIR/LLOYD/HITACHI/VOLTAS
Supply and fixing in replacement of display unit, suitable for Indoor unit of split type AC and capacity upto 2 Ton including making necessary connections complete all as specified and as directed by Engineer-in-Charge .Make :- LG/SAMSUNG/CARREIR/LLOYD/HITACHI/VOLTAS
Supply in replacement of Remote control, suitable for split type AC of any make/model and capacity upto 2 Ton complete all as specified and as directed by Engineer-in-Charge . Make :- LG/SAMSUNG/CARREIR/LLOYD/HITACHI/VOLTAS
Supply and fixing in replacement of unit back plate of GI Sheet, suitable for hanging in position indoor unit of split type AC of any make/model and capacity upto 2 Ton complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of gas valves made of brass, suitable for split type AC of any make/model and capacity upto 2 Ton including making necessary connections complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement indoor unit suitable for split type AC 1.5/2.0 Ton and including all accessories like blower fan, blower motor, swing blades, swing blade motor, indoor unit display, remote controlof suitable capacity to operate the unit, making all connections, soldering the pipes, detecting and rectifying the gas leaks and testing complete in all respects complete all as specified and as directed by Engineer-in-Charge. Make :- LG/SAMSUNG/CARREIR/LLOYD/HITACHI/VOLTAS
Supply and fixing in replacement outdoor unit suitable for split type AC 1.5/2.0 Ton and including all accessories like compressor, fan blades, fan motor, condensing coil etc making all connections, soldering the pipes, detecting and rectifying the gas leaks and testing complete in all respects complete all as specified and as directed by Engineer-in-Charge. Make :- LG/SAMSUNG/CARREIR/LLOYD/HITACHI/VOLTAS
Supply and fixing in replacement power relay single phase contactors of any make/model making necessary connections complete all as specified and as directed by Engineer-in-Charge Make: TIBCAP/EPCOS/Usha
Supply and fixing in replacement Heat Condensing coil suitable for outdoor unit of 1.5/2.0 TR Split Type AC of any make/model including soldering, replacement of nut and bolts complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement Indoor Cooling Condenser suitable for indoor unit of 1.5/2.0 TR Split Type AC of any make/model including soldering, replacement of nut and bolts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement over load protector suitable for split/window type AC of any make/model and capacity upto 2Ton including making necessary connections and testing complete all as specified and directed by Engineer - in- Charge.
Supply and fixing in replacement of fan blade upto 18 Inch (blower motor/ condenser motor) made of PVC heavy duty suitable for split/window type AC of any make/model and capacity upto 2Ton complete all as directed by Engineer-in-charge. Make: American/Universal/AUE/ Genuine Parts
Supply and fixing in replaement running capacitor 50 mfd suitable for window/split type AC of any make/model and capacity upto 2Ton including making necessary connections and testing complete all as directed by Engineer-in-charge.Make: TIBCAP/EPCOS/Usha
Supply and fixing in replacement of PVC air filter 20 microns (as per sample ) suitable for window type AC of any make/model and capacity upto 2 Ton complete all as specified and directed by Engineer - in - Charge.
Supply and fixing in replacement of PVC air filter 20 microns (as per sample ) suitable for split type AC of any make/model and capacity upto 2 Ton complete all as specified and directed by Engineer - in - Charge.
Supply and fixing in replacement wiring kit of copper conductor PVC insulated cable suitable for window type air conditioner of any type and capacity including making the necessary connections with brass thimbles complete all as directed by Engineer-in-charge.
Taking out the unserviceable fan motor from AC of any make/model and capacity upto 2 Ton installed at various locations of cantonment area and carry to local market, dismantling the fan motor complete, removing the burnt winding, cleaning the stator and then rewinding the stator with super enamelled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing class ‘B’ for insulation and replacing gun metal bush & shaft, reassembling the fan motor and re-fixing the same in original position in same installation/site/buildings and as per direction of Engineer-in-charge and testing compete all as directed by Engineer-in –Charge.
Supply and fixing in replacement plastic Front grill assembly complete suitable for any type and make (Volts/Amtrex/Blue Star/LG/Carrier etc) window type AC of capacity upto 2 Ton complete all as approved and directed by Engineer-in-charge.
Material and labour for cleaning/ flushing out the gas system with anti corrosive solution (CO2), with anti-moisture substance, condenser tubing by vacuumisation, pressure testing of the system, demoistureing the system , supply and charging of refrigerant gas and compressor oil in the window/split type air conditioner of capacity 1.5 Ton to its rated capacity including brazing, detection of leakage, rectification of leakage in the entire system if any and testing on full load complete all as specified and as directed by Engineer-in-Charge.
All as per item No 34 here-in-before but in the window/split type air conditioner of capacity 2 Ton. Note for item No. 34 & 35 : The type of refrigerant gas (i.e. R-12/R-22/R-134a) shall be charged as per compressor compatibility or OEM recommendations.
Taking out the unserviceable compressor from refrigerator of capacity 165/195/286/310 ltrs but any make/model, AC 230 volts single phase and supply and fixing same model /capacity sealed compressor obtained from the factory out let/authorised dealer alongwith test certificate and with one year guarantee card, including soldering of copper pipe, replacement of copper filter single capillary, replacement of foundation rubber pads, nut and bolts and testing on full load complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/ Whirlpool/ LG or as recommended by OEM. Note :- (i) Gas charging and gas shall be paid and measured separately under appropriate item of this Sch .
Supply and fixing in replacement Freezer chest (made out of aluminium) complete with cooling coil suitable for 280/286/310 Ltrs capacity refrigerator of any make/model including soldering of copper pipe, replacement of nut and bolts complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Gas charging and gas shall be paid and measured separately under appropriate item of this Sch .
Supply and fixing in replacement Freezer chest (made out of aluminium) complete with cooling coil suitable for 165/175/180/190 Ltrs capacity refrigerator of any make/model including soldering of copper pipe, replacement of nut and bolts complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Gas charging and gas shall be paid and measured separately under appropriate item of this Sch .
Supply and fixing in replacement MS Condensing coil suitable for 280/286/310 Ltrs capacity refrigerator of any make/model including soldering, replacement of nut and bolts complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Gas charging and gas shall be paid and measured separately under appropriate item of this Sch .
Supply and fixing in replacement MS Condensing coil suitable for 165/175/180/190 Ltrs capacity refrigerator of any make/model including soldering, replacement of nut and bolts complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Gas charging and gas shall be paid and measured separately under appropriate item of this Sch .
Material and labour for cleaning/ Flushing out the gas system with anti corrosive solution (CO2), with anti-moisture substance, condenser tubing by vacuumisation, pressure testing of the system, demoistureing the system , supply and charging of refrigerant gas and compressor oil in the refrigerator of capacity 280/286/310 Ltrs to its rated capacity including brazing, detection of leakage, rectification of leakage in the entire system if any and testing on full load complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cleaning/ Flushing out the gas system with anti corrosive solution (CO2), with anti-moisture substance, condenser tubing by vacuumisation, pressure testing of the system, demoistureing the system , supply and charging of refrigerant gas and compressor oil in the refrigerator of capacity 165/175/180/190 Ltrs to its rated capacity including brazing, detection of leakage, rectification of leakage in the entire system if any and testing on full load complete all as specified and as directed by Engineer-in-Charge. Note for item No. 26 and 27 : The type of refrigerant gas (i.e. R-12/R-22/R-134a) shall be charged as per compressor compatibility or compressor manufacturer recommendation.
Supply and fixing in replacement freezer door including spring suitable for 280/286/310 ltr capacity refrigerator of any make complete all as directed by Engineer-in-charge.
Supply and fixing in replacement freezer door including spring suitable for 165/175/180/190 ltr capacity refrigerator of any make complete all as directed by Engineer-in-charge.
Supply and fixing in replacement over load protector suitable for refrigerator of any make/model and capacity upto 310 Ltrs including making necessary connections and testing complete all as specified and directed by Engineer - in- Charge. Make : Ranutrol / Classic / Whirlpool / Danfoss
Supply and fixing in replacement of thermostat switch with knob, plate and screws for automatic defrosting device suitable for refrigerator of any make/model and capacity upto 310 Ltrs complete all as directed by Engineer - in - Charge. Make:- Whirlpool/Indfoss/ Annupurna/ Electrolux/ Ranutrol
Supply and fixing in replacement of Temp control knob with defrost push button suitable for refrigerator of any make/model and capacity upto 310 Ltrs complete all as directed by Engineer - in - Charge. Make :- Whirlpool/Indfoss/ Annupurna/ Electrolux/ Ranutrol
Supply and fixing in replacement Pigmy lamp screw type/pin type, 15 watt, 240 volts AC supply suitable for any type of refrigerator complete all as directed by Engineer-in-charge. Make : Philips/Bajaj or as approved by Engineer-in-Charge.
Supply only in replacement PVC Ice tray heavy duty superior quality suitable for refrigerator of any make/model and capacity upto 310 Ltrs complete all as directed by Engineer-in-charge.Make : As approved by Engineer-in-Charge.
Supply and fixing in replacement PVC vegetable tray with glass cover heavy duty superior quality suitable for refrigerator of any make/model and capacity upto 310 Ltrs complete all as directed by Engineer-in-charge.Make : As approved by Engineer-in-Charge.
Supply and fixing in replacement Adjustable shelves heavy duty superior quality suitable for refrigerator of any make/model and capacity upto 310 Ltrs complete all as directed by Engineer-in-charge.Make : As approved by Engineer-in-Charge.
Supply and fixing in replacement Chiller Tray (crisper tray ) heavy duty superior quality suitable for refrigerator of any make/model and capacity upto 310 Ltrs complete all as directed by Engineer-in-charge.Make : As approved by Engineer-in-Charge.
Supply and fixing in replacement Bottle Supporter superior quality suitable for refrigerator of any make/model and capacity 310 Ltrs complete all as directed by Engineer-in-charge.Make : As approved by Engineer-in-Charge.
Supply and fixing in replacement Bottle Supporter superior quality suitable for refrigerator of any make/model and capacity 286 Ltrs complete all as directed by Engineer-in-charge.Make : As approved by Engineer-in-Charge.
Supply only in replacement Bottle Supporter superior quality suitable for refrigerator of any make/model and capacity 165 Ltrs complete all as directed by Engineer-in-charge.Make : As approved by Engineer-in-Charge.
Supply and fixing in replacement magnetic door rubber beading (main door gasket) superior quality including fixing material suitable for refrigerator of any make/model and capacity 310 Ltrs complete all as directed by Engineer-in-charge.Make : As approved by Garrison Engineer
Supply and fixing in replacement magnetic door rubber beading (main door gasket) superior quality including fixing material suitable for refrigerator of any make/model and capacity 300 Ltrs complete all as directed by Engineer-in-charge.Make : As approved by Garrison Engineer
Supply and fixing in replacement magnetic door rubber beading (main door gasket) superior quality including fixing material suitable for refrigerator of any make/model and capacity 165 Ltrs complete all as directed by Engineer-in-charge.Make : As approved by Garrison Engineer
Supply and fixing in replacement Stainless steel Door handle superior quality suitable for refrigerator of any make/model and capacity upto 310 Ltrs complete all as directed by Engineer-in-charge.
Supply and fixing in replacement of Leg Set suitable for refrigerator of any make/model and capacity upto 310 Ltrs complete all as directed by Engineer-in-charge.
Supply and fixing in replacement Starting Relay assembly suitable for refrigerator of any make/model and capacity upto 310 Ltrs complete all as directed by Engineer-in-charge.Make :- Ranutrol/Anupurna/ Hitachi / Whirlpool/LG/Godrej
Supply and fixing in replacement PVC Drain tray suitable for refrigerator of any make/model and capacity upto 310 Ltrs complete all as directed by Engineer-in-charge.
Material and labour for scratching out the existing paint with emery/sand paper from exposed external surface of refrigerator (any make) of capacity 280/286/310 ltr, Preparation of surface and filling up the scratches with putty complete and applying spray painting with gun by using DUCO paint first quality (shade as directed) to refrigerator and anti-corrosive black paint to compressor and condenser coil including marking Sl No/SM No/MES No with black paint complete all as directed by Engineer-in-Charge. Make :- SSK/Vinay/Anchor/Fine/Bajaj/Kinja
Supply and fixing in replacement Plug top 3 pin 5 Amp, 240 volts, single phase complete all as directed by Engineer-in-charge.
Supply and fixing in replacement PVC insulated copper conductor flexible cable of size 30/0.25 or 1.5 Sqmm, 3 core, round complete all as directed by Engineer-in-Charge. Make:- Paragon/Finolex/Rallison/Standard/Havells/Plaza
Taking out the unserviceable compressor from Deep Freezer of capacity 300/320 ltrs but any make/model, AC 230 volts single phase and supply and fixing same model /capacity sealed compressor obtained from the factory out let/authorised dealer alongwith test certificate and with one year guarantee card, including soldering of copper pipe, replacement of copper filter single capillary, replacement of foundation rubber pads, nut and bolts and testing on full load complete all as specified and as directed by Engineer-in-Charge.Make : Kirloskar/ Whirlpool/ LG. Note :- (i) Gas charging and gas shall be paid and measured separately under appropriate item of this Sch .
Supply and fixing in replacement starting relay assembly complete suitable for deep freezer of capacity 300/310 ltrs but any make/model including making necessary connections and testing complete all as directed by Engineer-in-charge.Make :- Ranutrol/Anupurna/ Kirlosker/Danfoss
Supply and fixing in replacement thermostat switch protector suitable for deep freezer of capacity 300/310 ltrs but any make/model including making necessary connections and testing complete all as directed by Engineer-in-charge.Make :- Indfos/Ranutrol/Anupurna
Supply and fixing in replacement Starting capacitor 40/60 mfd oil filled, 230 volt including making necessary connections and testing complete all as directed by Engineer-in-charge.
Supply and fixing in replacement internal wiring kit of copper conductor PVC insulated cable suitable for deep freezer of capacity 300/310 ltrs including making the necessary connections with brass thimbles complete all as directed by Engineer-in-charge.
Supply and fixing in replacement Over load protector suitable for deep freezer of capacity 300/310 ltrs but any make/model including making necessary connections and testing complete all as directed by Engineer-in-charge.Model of protector: - 5N 283RFYY-520HHDTK Make : Ranutrol / Usha / Shriram/ Danfoss
Supply and fixing in replacement of fan motor, copper wound, single phase 240 Volts AC supply, suitable for deep freezer of capacity 300/320 ltrs including making necessary connections complete all as directed by Engineer-in-charge.Make:- American/GEC/Universal/AUE/DLF
Supply and fixing in replacement of fan blade made of aluminium (metallic) suitable for deep freezer of capacity 300/310 ltrs complete all as directed by Engineer-in-charge.Make: American/Universal/AUE/ Genuine Parts
Material and labour for cleaning/Flushing out the gas system with anti corrosive solution (CO2), with anti-moisture substance, condenser tubing by vacuumisation, pressure testing of the system, demoistureing the system , supply and charging of refrigerant gas and compressor oil in the deep freezer of 300/310 ltrs capacity to its rated capacity including brazing, checking of leakage, rectification of leakage in the entire system if any and testing on full load complete all as specified and as directed by Engineer-in-Charge. Note for item No. 74 : The type of refrigerant gas (i.e. R-12/R-22/R-134a) shall be charged as per compressor compatibility or OEM recommendation.
Supply and fixing in replacement of rusted/unserviceable deep freezer cooling tank suitable for 310/320 ltrs capacity complete with cooling coil.
Supply and fixing in replacement copper tubing 5/8" size along with adoptors,unions and flaring as required compete all as directed by Engineer-in-Charge.
Supply and fixing in replacement copper tubing 3/8" size along with adoptors,unions and flaring as required compete all as directed by Engineer-in-Charge.
Dismantling the unserviceable stabilizers 5 KVA capacity, repair/ renewal of defective part, reassembling and refixing the same in position complete with prooving for satisfactory operation all as directed by Engr-in-Charge. New parts replaced shall be paid separatelt under respective items of this scheadue.
Supply and fixing in replacement transformer for volatage stabilizer suitable for capacity 5 KVA complete
Supply and fixing in replacement relay set for voltage control of stabilizer for capacity 5 KVA complete
Supply and fixing in replacement Capillary tube thermostat suitable for window/split type AC of any make/model and capacity upto 2Ton including making necessary connections and testing complete all as directed by Engineer-in-charge. Make :- Indfos/Ranutrol/Anupurna
M&L for concealed Point wiring for One 3 pin 5 amps switch socket outlet point on independent board.with single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick bakeliteplastic laminated sheet top cover with brass counter shunk screws with washer complete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing surface.
All as per item Sl. No. 82 here in before but wiring with 2.5 sq.mm multistranded cable and earth wire with copper conductor of size 2.5 sq.mm for 15 amps power/Geyser Point.
S&F in replacement socket two in one 6/5 Pin 5 Amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F in replacement Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F in replacement socket two in one 6/5 Pin 15/16 Amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F in replacement piano type switch Sigle Pole one way 5 Amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
Material & Labour for Sub Main Wiring with two run single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 2.5 Sqmm copper green colour earth wire all as specified and directed by Engr-in-Charge. NOTE-two run of 4 sq.mm & One run of 2.5 sq.mm & One run of PVC conduit with accessories shall be measured as One length.
Material & Labour for Sub Main Wiring with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engr-in-Charge. NOTE-two run of 6 sq.mm & One run of 4 sq.mm & One run of PVC conduit with accessories shall be measured as One length.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp Complete all as specified and directed by Engr-In-Charge
Supply and fixing Metal Clad Plug 2 Pin Plug top complete all as specified and directed by Engr-In-Charge
Supply and fixing SP 6-32 Amp, 240V, 10KA 'C' curve MCB fixed in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-In-Charge
Taking down carefully copper/aluminium point wiring of any size (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately), and making good disturbed surfaces of walls, floors etc to match with existing surfaces.
Taking down MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces
Supply and charging of refrigerant gas R-22 (Freon) (R-32, R-410) as applicable in Split/window type AC of any capacity up to the required pressure including T & P for charging at site and before charging checking of gas leakage, rectification of leakage in the entire system if any and testing on full load complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement PVC flexible AC drain hose pipe 15 mm dia, 2 metre length with adopter and clamping arrangement complete all as directed by Engineer-in-charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
jassal engineering
Lalgarhia Enterprises
SWARN SINGH AND CO.
MAJOR REFREGERATION AND ELECTRICALS
Singla Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .