Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
19 Dec 2023, 6:00 pmClosed
AGE I AF Mount Abu
AGE (I) AF Mount Abu Sirohi Raj 307501
REPAIR REPLACEMENT AND MAINT OF PUMP SETS RO PLANTS AND WATER SUPPLY INSTALLATION AT AF STN MOUNT ABU
2023_MES_629169_1
8409/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Mount Abu
As per NIT
7 documents required · 7 mandatory
₹500
Yes
AGE I AF Mount Abu
₹19,000
Yes
12 Jan 2024
21 Nov 2023
21 Dec 2023
21 Nov 2023
19 Dec 2023
6 Dec 2023
21 Nov 2023 - 27 Nov 2023
Amount
Comprehensive maintenance servicing and testing of RO plant of 400 Ltrs/hr capacity including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set & dosing unit for supply qualitative water at permissible level of TDS as and when directed by Engr-in- charge. Note :- (a) Spares required for replacement shall be measured and paid separately.
S & F in repair sediment filter for 400 ltr RO Plant all as specified & directed by Engr-in-charge.
Supply only RO Membrane for 400 Ltrs RO plant all as specified & directed. Make-Hydranautic/Hydramen/Ion Exchange
supply only carbon media for RO plant used in item no. 1.00 here-in-before all as specified & directed.
Supply only Resin media For RO plant used in item no. 1.00 here-in-before all as specified & directed.
S&F in repair Strainer for 400 Ltrs RO Plant all as specified & directed .
Supply only Sand for RO plant used in item no. 1.00 here-in-before all as specified & directed.
S&F in repair Rejection valve for 400 ltrs RO Plant all as specified & directed.
S&F in repair pressure guage range (0 to 7 Kg/cm2) all as specified & directed by engr-in-charge.
S&F in repair superior quality pvc multiport valve complete for sand vessel all as specified & directed.
S&F in repair submersible copper cable 3 core of size 6.0 sqmm with properly connecting to the pump and panel complete all specified & directed.
M & L taking out/unlowering of submersible pump set capacity 7.5 HP with GI tubing 50 mm dia in 3 mtrs length with flanged Total – 20 Nos length (Old u/s pipe will not be replaced under this item) (i) Dismantling of vertical submersible pump set complete for servicing and rewinding of motor (ii) Replacement of thrust piece/washers/ bushes and bronze impeller of Pump set and bearing and servicing pump set complete (iii) Rewinding of pump motor with suitable gauge copper widning wire, insulation materials and etc. (iv) Reassemble to pump set and motor complete. (v) Lowering of pump set with existing GI tubing 3 RM piece of 23 Nos with replacement of Nut & bolt etc.
Taking out of Horizental submersible pump set capacity 7.5 HP with GI tubing 50 mm dia ( Old u/s pipe will not be replaced under this item) (i) Dismantling of Horizental submersible pump set complete for servicing and rewinding of motor (ii) Replacement of thrust piece/washers/ bushes and bronze impeller of Pump set and bearing and servicing pump set complete (iii) Rewinding of pump motor with suitable gauge copper widning wire, insulation materials and etc. (iv) Reassemble to pump set and motor complete. (v) Lowering of pump set in UG Sump
Repair to monoblock Pump set 20 HP Installed at sump pump house Mount Abu the following comprising :- (a) Disconnect water and electric connection from Pump set . (b) Dismentling of complete pump set for rewinding and servicing (c) Rewinding of pump motor with suitable gauge copper winding wire, insulation materials and etc. (d) Replacement of pump bearing Qty - 01 No. (e) Replacement/repair of impeller Qty - 01 No. (f) Reassemble to pump set and motor complete. (g) Refix pump set and motor with electric & water connection complete.
Repair to monoblock multistage Pump set 10 HP the following comprising :- (a) Disconnect water and electric connection from Pump set . (b) Dismentling of complete pump set for rewinding and servicing (c) Rewinding of pump motor with suitable gauge copper widning wire, insulation materials and etc. (c) Rewinding of pump motor with suitable gauge copper widning wire, insulation materials and etc. (d) Replacement of pump bearing Qty - 01 No. (e) Replacement/replacement of impeller Qty - 01 No. (f) Reassemble to pump set and motor complete. (g) Refix pump set and motor with electric & water connection complete.
Supply Only calcium hypochlorite Grannule type 90 to 120 GPL in PVC container all as specified and directed by Engr-in-charge.
S&F tubes Medium grade galvanised with all fittings as Tees, bends, etc including taking up or down steel tubing alongwith fittings such as Tee, bends etc and corrections incl stacking of size 65mm bore complete all as specified and directed.
Description all as per BOQ srl item No 17.00 here-in-before but of size 80 mm bore
Description all as per BOQ srl item No 17.00 here-in-before but of size 100 mm bore
M&L for oiling and greasing of pump motor parts(any make any size any type) by means of greasing gun or manually by unbolting and separating the pump motor set at pump house inside defense area complete for smooth operation of machinery including replacement of nut bolts washers of appropriate size as per site and motor pump size complete making it leakage free and applying galnd packing of necessary quantity and thickness and making working complete noise and leakage free and refixing in its original position all as directed by EIC. Note: Rates for greese,lubricating oil and galnd packing deemed to included in quoted rates.Also, measurment of these items will be saperate and not to be included in any other item above.
M&L in repair for Cement concrete Type B2 1:2:4(20mm graded aggregate) in foundations, filling and mass concrete for foundation of motor pump set complete by using 10mm thick MS Sheet of approprite size and welding proper size and length of bolt and nut in foundation for avoiding vibration at the time of operation of motor pump set complete with demolition of existing foundation and considering of alignment of motor pump set complete all as specified and directed by Engr-In-Charge.(for 20 HP to 40 HP)
Disconnecting, unbolting and taking out existing centrifugal pump/Mono Block pump set of capacity 20 HP, electric driven 3 phase 415 volt including Re-fixing in the same position after repair with necessary screw and bolts complete all as directed by Engineer-in-Charge. Note: The necesary lifting tools and man power will be part of quoted rates.
Description all as per BOQ srl item No 22.00 here-in-before but Centrifugal/Monoblock pump set of capacity 10 HP
Description all as per BOQ srl item No 22.00 here-in-before but Centrifugal/Monoblock pump set of capacity 7.5 HP
Supply and fix in repair deep Groove ball/roller bearing for 7.5 HP pump (Primary and secondary) .Note: The rates include cost of two nos bearing as per motor design. Both the bearings(as per pump make) to be replaced at the same time for existing centrifugal/Monoblock pump set electric driven 3 phase 415 volt complete all as specified and directed by Engr-In-Charge.
Description all as per BOQ srl item No 25.00 here-in-before but Deep Groove ball/roller bearing(Double sealed ball bearing)for 20 HP pump (Primary and secondary) Note: The rates include cost of two nos bearing as per pump design. Both the bearings(as per pump make) to be replaced at the same time.
Description all as per BOQ srl item No 25.00 here-in-before but S & F Motor cooling fan 12.5 to 20 Hp all as specified & directed by engr-in-charge.
Description all as per BOQ srl item No 25.00 here-in-before but S & F Motor cooling fan 5 to 10 Hp all as specified & directed by engr-in-charge.
Description all as per BOQ srl item No 25.00 here-in-before but S & F in repair Neck ring for any capacity pump set as per site all as specified & directed by engr-in-charge.
Description all as per BOQ srl item No 25.00 here-in-before but S & F in repair Contactor for upto 20 HP Motor Starter (Amp rating as per site) including removing of exiting burnt/US contactor and cleaning of carbon complete all as specified and directed by Engr-In-Charge..Make: Havells, L&T, BCH
Description all as per BOQ srl item No 25.00 here-in-before but Shaft coupling spider(regular or tyre type) for any thickness as per site and any type of coupling/HP motor as per site
Description all as per BOQ srl item No 25.00 here-in-before but S & F in repair motor starter relay for 7.5HP to 20 HP(as per site requirement) Motor Starter (Amp rating as per site) including removing of exiting burnt/US relay complete all as specified and directed by Engr-In-Charge..Make: Havells, L&T, BCH
Supply and fix in repair Thrust bearing of suitable size motor as per site for existing submerisble pump set electric driven 3 phase 415 volt 7.5 to 10 HP complete all as specified and directed by EIC.
Description all as per BOQ srl item No 33.00 here-in-before but S & F Thrust plate with key of suitable size motor as per site.
Description all as per BOQ srl item No 33.00 here-in-before but S & F Thrust Bearing housing of suitable size motor as per site.
Description all as per BOQ srl item No 33.00 here-in-before but S & F Bearing Bush of suitable size motor as per site(Upper and lower set) Rubber or gunmetal
Description all as per BOQ srl item No 33.00 here-in-before but S&F Rotor Sleeve SS (upper and lower) of suitable size motor sets per site
Description all as per BOQ srl item No 33.00 here-in-before but S & F Sand Guard of SS of suitable size as per site
Description all as per BOQ srl item No 33.00 here-in-before but Motor Pump coupling SS including key for suitable size motor as per site
Checking of Chlorine doser pnuematic mechanism & servicing/ maintenance of Dozer with suction and discharge pipes / valves and all electrical connections Complete all as specified & directed.
Comprehensive maintenance servicing and testing of filteration plant including washing, cleaning of sedimentation filter, disinfection process, servicing of all presure gauges outer pipelins cleaning etc.work include the follwing (i)Dismantling of Filtration plant and remove alternate layers of media like sand, carbon and gravel (ii)Dismantling of connected pipe line, pressure gauge and valves etc. (iii)Replacement of sand media complete (iv)Replacement of carbon media complete (v)Replacement of gravel media complete (vi)After servicing, repair of filtration plant assemble to match existing incoming and outgoing pipe lines complete (Vii)Replacement of pressure gauge 14kgf/cm2 -02 Nos complete (Viii)Replacement of old nut, fasteners and screws complete to match the existing size of filtration plant (viii) painting of Filtration plant And valves And Writing date of cleaning after servicing complete (ix) welding of flange or joint if required .
M&L for painting of pump sets after removing old paint and preparing old paint surfaces with two coat of Aluminium paint and two coats of enamel paint of approved make from ground level & upto 1 mtr high including white washing terminal box all as directed by Engineer - in - Charge.
M&L for painting of Lt panels after removing old paint and preparing old paint surfaces with two coat of Aluminium paint and two coats of enamel paint of approved make from ground level & upto 1 mtr high including white washing terminal box all as directed by Engineer - in - Charge.
S & F in repair water pump of DG Set of 125Kva Crompton greaves, including dismantling all type of parts to facilitate fixing of water pump complete with all necessary accessories complete all as directed by engr-in-charge
ANKIT BUILDERS
boon construction company
M/S Balkishan Panwar Construction
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .