Loading…
Loading…
Tender Value
₹26.0 L
EMD Value
₹61,760
Closing Date
10 Jun 2026, 10:30 pm5d left
Directorate of Municipal Administration
Annual Repair, Rewinding and Breakdown Attending Works of Submersible Pumps and Motors of Mini Water Supply Schemes in Wards 1, 15 to 24, 36 & 37 of Zone-1 for the Year 2026-27 in Ballari City Corporation
301460
DMA/2026-27/EL/WORK_INDENT58763
Open
Electrical
DMA City Corporation Ballari
4 documents required · 0 mandatory · 4 optional
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Proposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)
Mandating satisfactory completion as a prime contractor for at least one Elctrical work to an extent of 50% of the cost of the work, for all works costing upto and Rs.100 lakh. Rs.15,44,000.00
All the bidders, bidding for the Work, shall be registered with Electrical Inspectorate Department.
The contractor should have liquid assets and /or availability of credit facilities of not less than Rs.9,25,400 (Unconditional Credit line/Letter of credit/Certificates from Banks for meeting the fund requirement etc
Achieved in at least two financial years an average annual financial turnover Rs.30,88,000.00 with UDIN number
₹660
₹61,760
27 May 2026
27 May 2026
12 Jun 2026
10 Jun 2026
Annual Repair, Rewinding and Breakdown Attending Works of Submersible Pumps and Motors of Mini Water Supply Schemes in Wards 1, 15 to 24, 36 & 37 of Zone-1 for the Year 2026-27 in Ballari City Corporation
Rewinding of submersible pumpset with copper winding wires of appropriate guage, as per specifications and / or directions of the departmental officials, including all materials, labour, equipment and...
Rewinding of submersible pumpset with copper winding wires of appropriate guage, as per specifications and / or directions of the departmental officials, including all materials, labour, equipment and...
Replacing Of Pump Parts.The Following Main Componenets Of Submersible Pumpsets Requiring Replacements as per ISI specifiction with guarantee period of not less than 12 months.Intermediate piece (IP) I...
Replacing Of Pump Parts.The Following Main Componenets Of Submersible Pumpsets Requiring Replacements as per ISI specifiction with guarantee period of not less than 12 monthsImpeller shell moulded wit...
Replacing Of Pump Parts.The Following Main Componenets Of Submersible Pumpsets Requiring Replacements as per ISI specifiction with guarantee period of not less than 12 months Steel Bush (D O Steel Bus...
Replacing Of Pump Parts.The Following Main Componenets Of Submersible Pumpsets Requiring Replacements as per ISI specifiction with guarantee period of not less than 12 months Allen screw Common SR o...
Replacing Of Pump Parts.The Following Main Componenets Of Submersible Pumpsets Requiring Replacements as per ISI specifiction with guarantee period of not less than 12 monthspump shaft (stainless stee...
Replacing Of Pump Parts.The Following Main Componenets Of Submersible Pumpsets Requiring Replacements as per ISI specifiction with guarantee period of not less than 12 months pump coupling(stainless)....
Replacing Of Pump Parts.The Following Main Componenets Of Submersible Pumpsets Requiring Replacements as per ISI specifiction with guarantee period of not less than 12 months Brass Filter Common SR of...
Supplying, laying, jointing, testing and commisioning of GI pipes confirming to IS 1239:1990 with latest amendments including fixing collars, elbows, tees, bends, gland cocks and other fittings (exclu...
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog
Lifting Of Submersible Pumpsets. Common SR of WS&SW Vol-5 2023-24 [Page No-148 Sl No-13.2.10 ]
Transportion Of Pumping Machinery Common SR of WS&SW Vol-5 2023-24 [Page No-148 Sl No-13.2.10 ]
Re-errection charges Of Pumping Machinery Including Overhauling and Painting .KUWS &DB Rates 2021-22 [P, No157 Sl No.3.19.P030S]
Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools a...
Supply and delivery at site brand new best make PVC insulated cable of flat 3 core (sheathed) area as per IS 694-1990 with ISI mark and as per its latest amendments 1x3x2.5Sqm. Common SR of WS&SW Vol-...
Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/2...
Fixing a shunt capacitor of … KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. Upto 5 KVAR Common Ele SR 2023-24 ...
Providing Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and...
Providing Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and...
Lifting of struck up submersible pump set. Above 300 ft Common SR of WS&SW Vol-5 2023-24 [Page No-142 Sl No-12.27 ]
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
zone1 26 bid-kw_2.doc
Tender Document • 2.05 MB
Download all tender documents and submit your bid