Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 CrAccepted-AOC | ₹28.1 Cr Quoted ₹28.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹29.9 CrRejected-Finance | ₹29.9 Cr | L2 | Rejected-Finance Being L2 |
| 3 | L3₹31.3 CrRejected-Finance | ₹31.3 Cr | L3 | Rejected-Finance Being L3 |
| 4 | L4₹32.7 CrRejected-Finance | ₹32.7 Cr | L4 | Rejected-Finance Being L4 |
| 5 | L5₹33.9 CrRejected-Finance 421 4TH FLOOR TOWER A 2 SPAZE ITECH PARK SECTOR 49 SOHNA ROAD GURGAON | GURUGRAM | HARYANA | 122001 | ₹33.9 Cr | L5 | Rejected-Finance Being L5 |
Tender Value
₹29.4 Cr
EMD Value
₹15 L
Closing Date
13 Sept 2024, 6:00 pmClosed
CHIEF ENGINEER LUCKNOW ZONE, LUCKNOW
HQ CHIEF ENGINEER LUCKNOW ZONE, 17 CARIAPPA ROAD, LUCKNOW
PROVN OF KLP (PH-III OF III PHASE) UNDER GE (EAST) AGRA
2024_MES_650611_2
CELZ/AGR/T-05 OF 2023-24
Open Tender
Civil Works
900 days
AGRA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (EAST) AGRA
₹15 L
15 Oct 2024
24 Jul 2024
20 Sept 2024
24 Jul 2024
13 Sept 2024
21 Aug 2024
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, Excavation and Earth work)
Total amount of Sch 'A' Part III (Internal Water Supply)
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Road, Path and Haed Standing)
Total amount of Sch 'A' Part VI (Area Drainage)
Total amount of Sch 'A' Part VII (Sewage Disposal)
Total amount of Sch 'A' Part VIII (Rain Water Harvesting)
Total amount of Sch 'A' Part IX (External Water Supply)
Total amount of Sch 'A' Part X (External Electrification)
Total amount of Sch 'A' Part XI (Conduit And Wiring For Tele/TV)
Total amount of Sch 'A' Part XII (Lightening Protection)
Total amount of Sch 'A' Part XIII (Earthing for Over Head Crane (EOT))
Total amount of Sch 'A' Part XIV (Dismantling/Demolition)
Sch 'A' Part - XV(Miscellaneous Items) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
INTERNAL WATER SUPPLY S&F for two way Angle cock/ stop valve, fancy type, chromium plated, ISI marked with crutch or butterfly handle, screwed down, screwed for iron pipe and fixed to 15mm bore pipe and fixed complete all as specified and as directed.
S&F for 3 in 1 , CP wall mixture for mixing hot and cold water with overhead shower arrangement screwed down for iron pipe and and fixed for 15mm bore pipe complete all as specified and as directed.
S&F Shower rose, brass, chromium plated 125 mm size with or without swivel joints, any size, including 450mm longh CP Shower arm fixing to steel pipe or union complete all as specified and directed.
S&F for health faucet with 1.50 m long cord, chromium plated suitable for 15mm dia pipe including fixing of brackets complete all as specified and as directed.
INTERNAL ELECTRIFICATION M&L for point wiring complete for One light/Fan/Exhaust fan/Bell point controlled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 sqmm (nominal area), ISI marked,multi stranded copper conductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , MS conduit in roof/floors, factory made pressed steel concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC ,FRLSH cable insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for point wiring complete for One light point controlled by two 2-way switches with PVC insulated and unsheathed FRLSH cable 1.5 sqmm (nominal area), ISI marked,multi stranded copper conductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , MS conduit in roof/floors, factory made pressed steel concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC ,FRLSH cable insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and all as specified and directed.complete . Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for point wiring complete for One 5 pin 5 Amp switch socket out let point on an independent board with PVC insulated and unsheathed FRLSH cable 2.5 sqmm (nominal area), ISI marked,multi stranded copper conductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , MS conduit in roof/floors, factory made pressed steel concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 2.5 Sqmm PVC ,FRLSH cable insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories complete for max four nos socket outlets all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for point wiring complete with PVC insulated and unsheathed, FRLS cable 2.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia PVC conduit concealed in wall and MS conduit in roof/floor slab & ceiling, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all for max two nos socket outlets all as specified and directed. Note :- In case of roof/ceiling, heavy duty pipe shall be used without any extra cost.
S&F switch flush type 5/6 Amps single pole two way complete all as specified and dierected.
Supply and fix PVC / polycarbonate angle type holder suitable for LED Bulb & including LED bulb 9Watt, B22 AC 220V complete all as specified and dierected.
S&F LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
S&F LED Building security light fitting with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <25 W (25/30W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 25/32 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
Supply and fix LED high bay light 120watt , 5000K/6500K , IP-65, IK-08, CRI >80, surge protection 4kv, driver efficiency >93% suitable for AC 220V 50 Hz, efficacy 125lm/watt optionally for DALI dimming for even further saving with toughned glass and mounting accessories, in built driver circular, square or retangular shape duly electrical connection with proper size of coppet wire complete all as specified.
Supply and fixing BLDC type Ceiling fan 1200 mm sweep five star rated single phase 230V AC, Min 220 CFM with fan remote , five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long for connection complete all as specified. Note:- Necessary Fan hook deemed to be included in item rate.
Supply and fixing Exhaust Fan high quality mettalic body, resistant to colour change 300 mm sweep five star rated, 900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed.
Supply and fixing Exhaust Fan high quality mettalic body, resistant to colour change 450 mm sweep five star rated, min 900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed. (for hanger only)
Supply and fixing Air Circulator Fan 600 mm sweep five star rated, 1400 RPM heavy duty metal body wall mounted type with bracket, aerodynamically designed & balanced blade 3 nos having double ball bearing ZZ (permanent lubricated) for longer life and minimum noise level, with approved colour complete including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed.
S & F sheet metal enclosure single pole and neutral with two pin (for AC point) with earth terminal complete incl one no MCB SP 20/25 amp 10KA complete all as specified and directed.
S&F MCCB 4 pole 415 V AC 50 Hz fixed type 125 -160 amps with breaking capacity 16 KA complete all as specified and directed.
S&F MCB TPN 63 amp 4 P 415 V AC 50 Hz fixed type 63 amps with breaking capacity 10 KA complete complete all as specified and directed.
S&F MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.
S&F MCCB TPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. .
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 4 way all as specified and directed .
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 8 way all as specified and directed .
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 12 way ISI marked all as specified and directed .
S&F MCB SPN 32/40 Amps 'B" series,10 KA 240 Volts ,AC ISI marked all as specified and directed .
S&F MCB 6-32 Amps single pole,240V/415 V, 'B' Series, 50 Hz ,AC with breaking capacity 10 KA , complete all as specified and directed.
M&L submain wiring with two single core 4 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 25 mm dia medium grade ISI marked concealed in wall surface / ceiling for sub main connection including 4 sqmm FRLSH one single core PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Two single core 4 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit.
M&L submain wiring with two single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including one 6 sqmm FRLSH one single core PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Two single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit.
M&L submain wiring with four single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 32mm dia medium grade concealed in wall surface / ceiling for sub main connection including one 6 sqmm single core FRLSH PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- four single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. below ground level connecting to galvanised earth lead wire 4.0 mm dia as earth lead upto 7.5 meters long connected by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe medium grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 3mm fixing with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt,20/ 40mm dia, medium grade, GI pipe as protection to GI wire 4.0 mm as main earthing lead from earth electrode to main TPN MCCBs DB/MCB DB/ test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing and testing complete all as specified and directed .
Taking down old U/S service connection/sub main wiring of any description of aluminium/copper conductor including batten/conduit/suspension wire etc and making good disturbed surface to match the existing surface.
Taking down old U/S DB with MCBs/Main switches/MCB SP/SPN of any description and in any position.
Taking down old U/S light fitting of any type and size complete all as directed
Taking down old U/S service wire of any type and size complete all as directed
ROAD, PATH AND HARD STANING M&L for preparation of road surface and applying thermoplastic reflective paint for marking of minimum 2mm thick single coat as a centre line or edge line etc. road marking of painting lines, dashes,arrows,letters etc on roads pavement and the like exc 10cm wide with road marking paint,white or golden yellow etc complete all as per manufacture instruction and specified and directed
S&F in repair 60 cm dia 2.5" thick and over convex mirror fixed with 6.75 feet long pole with coping of size 30 cm x 30 cm x45 cm size including 50x50x6mm thick size T- Section including earth work and cement concrete 1:2:4 Type B-1 (using 20mm graded stone aggregate) and all necessary fitting and fixures to fix the convex mirror complete all as specified and directed.
SEWAGE DISPOSAL Construction of RCC Septic tank conventional type for 50 users designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole opening with cover connection etc complete with effective depth of 1.5 m and overall depth of 3 m complete all as specified and directed.
Construction of RCC Septic tank conventional type for 100 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole opening with cover connection etc complete with effective depth of 1.5 m and overall depth of 3 m complete all as specified and directed.
Construction of RCC Septic tank conventional type for 150 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole opening with cover connection etc complete with effective depth of 1.5 m and overall depth of 3 m complete all as specified and directed.
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 m dia x 3.00 m effective depth complete all as specified and directed.
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 m dia x 3.00 m effective depth complete all as specified and directed.
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3 m dia x 3.00 m effective depth complete all as specified and directed.
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3 m dia x 4.50 m effective depth complete all as specified and directed.
RAINWATER HARVESTING Supply and filling 100mm to 200mm sixe boulder for recharge pit from Lal gun quarry complete all as specified and directed.
Supply and filling 40mm to 63mm sixe boulder for recharge pit from Lal gun quarry complete all as specified and directed.
Supply and filling coarse sand for recharge pit coplete all as specified and directed.
M & L pea Gravel packing of size 06 to 10mm for trail bore of size to be designed by the contractor natural shape brought direct from river bed and packing around the casing pipe to entire depth upto ground level complete all as specified and directed.
S&F 100mm bore PVC 'U' type air bend coplete all as specified and directed.
Drilling bore well of 200mm dia upto 60mtr dedpth in any type of soil for lowering to the PVC pipe complete all as specified and directed.
M&L plain PVC Pipe, 100 mm dia bore as per IS 12818 including lowering and jointing complete all as specified and directed.
M&L PVC slotted 110mm bore single socketed (6mtr lenth) of pressure 6 kg/sqcm and lower to bore as per IS 12818 including all fitting complete all as specified and directed.
S&F PVC bail plug for 110mm outer dia complete all as specified and directed.
S&F PVC well cap for 110mm outer dia complete all as specified and directed.
Development of bore well by air compressor having capacity 450/150 CFM/PSI complete all as specified and directed.
S&F PVC pipe 160mm outer dia , single socketed of pressure 6 kg/sqcm in any length with rubber ring joints laid in trenches or in floor including all fitting complete all as specified and directed.
S&F stainless steel sheet for screen chamber of thickness 16 gauge with rounded punched holes of 15 mm dia and area of each screen chamber not exceeding 1.00 Sqm fixed with angle grooves and removeable with one end (top end) having additional thickness for holding for cleaning purpose complete all as specified and directed.
S&F stainless steel grating to cover the PVC pipe 110 mm outer dia with made of 8 mm dia SS bar(grade 504) with coller and aperture 50mm centre to centre complete all as specified and directed.
S&F for 150mm PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors with cement concrete bed of PCC (1:4:8) type D-2 using 40mm graded stone aggregate complete all as specified and directed.
S&F for 200mm PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors with cement concrete bed of PCC (1:4:8) type D-2 using 40mm graded stone aggregate complete all as specified and directed.
Supply and fixing of 150mm cast iron air release valve with drilled flanged ends, pressure rating (PN-1) and tamper proof with two air outlets with nuts, bolts and washer and conforming to IS-14845 complete all as specified and directed.
Supply and fixing of 100mm cast iron air release valve with drilled flanged ends, pressure rating (PN-1) and tamper proof with two air outlets with nuts, bolts and washer and conforming to IS-14845 complete all as specified and directed.
Supply and fix Sluice valve 150mm bore both ends flanged class PN 1.0 with stainless steel spindle and 01 No hand wheel including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size necessary including testing complete all as specified and directed.
Supply and fix Sluice valve 80mm bore both ends flanged class PN 1.0 with stainless steel spindle and 01 No hand wheel including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size necessary including testing complete all as specified and directed.
Supply and fix Sluice valve 50mm bore both ends flanged class PN 1.0 with stainless steel spindle and 01 No hand wheel including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size necessary including testing complete all as specified and directed.
Taking up or down 80mm bore GI water tubing and connection for re-routing from trenches/floor etc complete all as specified and directed.
Laying only old GI water tubing 80mm bore in trenches/ floor including new GI fitting as directed. Note: GI water tubing obtained from items here-in-before.
Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 of 11 mtr long, all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of upto 110mm bore HDPE pipe of any description below/under existing road surfaces/apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing strata after laying pipes complete all as specified and directed. NOTE : (i) Pipes shall be laid minimum 60 cm below/under existing road surfaces/ apron /floors etc. (ii) Equipment, tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor without any extra cost to the Govt.
Supply ,installation, testing and commissioning of canopy headed HT 11K volt grade, 3 phase , AC, 50 cycle, feeder pillar box, factory made CPRI approved and as per IS-61439 outdoor pedestal type double door, IP 65 protection with incoming and outgoing cable entry glands fabricated out of 3.15 mm thick CRCA sheet with powder coated painting in side and outside of approved shade ,locking arrangement with 02 Nos 19mm dia lock of make Godrej with keys, two earthy terminal suitable cable gland for all incoming and outgoing cable grouting of feeder pillar box 30 cm above ground level by providing 90 cm long angle iron of size 50x50x6 mm welded on all the four comers embedded in PCC (1:2:4) using 20 mm graded stone agg upto 30 CM deep and 45 CM above from normal ground level complete all as specified and directed incl the following components:- (a) The panel will be having aluminium bus bar of size 50x10mm duly insulated with heat shrinkable sleeves with porcelain HT long post insulator 11 KV, Complete all as specified and directed.
Supply and laying HDPE pipe double wall medium class, ISI Marked corrugated as in cable protection pipe of outer dia 110 mm including all fittings complete all as specified and directed.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply and fixing LED street light fitting 70 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 1.5 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed.
Supply and fix junction/looping box polycarbonate alongwith clamps complete, pole mounted right hinged looping box of size 155 x 210 x 92 with MCB SP 6 Amp capacity, copper bus bar-4 Nos fixed on ebonite insulator suitable capacity for 3 phase and neutral complete with necessary MS clamp made of 25 x3 mm MS flat, bolts, Nuts, washers etc for fixing to steel tubular /rail pole including all accessories. complete all as specified and directed.
Supply and fix street light timer switch with voltage mounting device enclcosed in SMC Enclosure for automatic and manual switching of street light based on LUX level of natural light , The sensor along with suitable power contactor MCB support terminal shell be housed in enclosure complete made out of anti rust/ shock proof/ termite proof/ confirming to IP 54 suitable for 5-8 KW (40 Amp) load compete all as specified and directed.
Supply and fix, New generation, IP 65 LED post-top lantern 40 W, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. 230 watt volts, AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, Clear Cover offers bright illumination for different applications complete all as specified and as directed.
Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel strip 32x6 mm as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm pipe medium grade for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore GI Pipe medium grade for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply, install, test and commissioning of Outdoor cubical type LT feeder pillar box, factory made, dust and vermin proof, double door (front and back openable by keyy from both side fancy locks), cubical and duly fully compartmentalized and separation from each control switchgear, 415 volts, AC, 50 Hz, IP-54, fabricated with 3.15 mm thick CRCA sheet for outer side and 2mm thick inside complete with and including mounted on angle iron frame stand of size 50 x 50 x 6 mm thick 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, having seven tank treatment process for powder coating, enclosed bus bar chamber with aluminium bus bar (04 Nos) of rating not less than 1.5 times of incomming , mounted on PVC insulators, electric connection complete with from MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement including PCC work, excavation & earth work complete and comprising supply and fix for following etc complete all as specified and as directed:- Incoming : (a) Aluminium busbar chamber comprising 4 Nos strip PVC insulated with current capacity 400 Amp with stand heat shrinkable sleeking alongwith shrouds for joints , PVC sheathed with colour coding (b) Incommer MCCB, 4 pole having current ratings 200 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 01 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A, Outgoing : (a) MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 16 KA, Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 02 Nos (b) MCB, DP 6 Amp, C Curve, 240 volts, 10 KA - Qty - 01 No
Supply, install, test and commissioning of Outdoor cubical type LT feeder pillar box, factory made, dust and vermin proof, double door (front and back openable by key from both side fancy locks), cubical and duly fully compartmentalized and separation from each control switchgear, 415 volts, AC, 50 Hz, IP-54, fabricated with 3.15 mm thick CRCA sheet for outer side and 2mm thick inside complete with and including mounted on angle iron frame stand of size 50 x 50 x 6 mm thick 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, having seven tank treatment process for powder coating, enclosed bus bar chamber with aluminium bus bar (04 Nos) of rating not less than 1.5 times of incomming , mounted on PVC insulators, electric connection complete with from MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement including PCC work, excavation & earth work complete and comprising supply and fix for following etc complete all as specified and as directed:- Incoming : (a) Aluminium busbar chamber comprising 4 Nos strip PVC insulated with current capacity 600 Amp with stand heat shrinkable sleeking alongwith shrouds for joints , PVC sheathed with colour coding (b) Incommer MCCB, 4 pole having current ratings 320 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 01 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A, Outgoing : (a) MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 16 KA, Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 05 Nos (b) MCB, DP 6 Amp, C Curve, 240 volts, 10 KA - Qty - 01 No
Supply, install, test and commissioning of Outdoor cubical type LT feeder pillar box, factory made, dust and vermin proof, double door (front and back openable by key from both side fancy locks), cubical and duly fully compartmentalized and separation from each control switchgear, 415 volts, AC, 50 Hz, IP-54, fabricated with 3.15 mm thick CRCA sheet for outer side and 2mm thick inside complete with and including mounted on angle iron frame stand of size 50 x 50 x 6 mm thick 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, having seven tank treatment process for powder coating, enclosed bus bar chamber with aluminium bus bar (04 Nos) of rating not less than 1.5 times of incomming , mounted on PVC insulators, electric connection complete with from MCCB to main bus bar, cable glands, thimble complete with and including openable shutters butt hinged, locking arrangement including PCC work, excavation & earth work complete and comprising supply and fix for following etc complete all as specified and as directed:- Incoming : (a) Aluminium busbar chamber comprising 4 Nos strips PVC insulated with current capacity 400 Amp with stand heat shrinkable sleeking alongwith shrouds for joints , PVC sheathed with colour coding (b) Incommer MCCB, 4 pole having current ratings 200 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 01 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A, Outgoing : (a) MCCB, 4 pole having current ratings 63 Amps, AC 415 Volts, with Icu= 16 KA, Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 02 Nos (b) MCCB, 4 pole having current ratings 32 Amps, AC 415 Volts, with Icu= 16 KA, Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 03 Nos (c) MCB, DP 6 Amp, C Curve, 240 volts, 10 KA - Qty - 01 No
CONDUIT AND WIRING FOR TELE/TV M&L for point wiring with telephone cable copper conductor FRLSH, Two pair, 0.50 sqmm, P.V.C. insulated and sheathed , anti termite, colour coded twisted pairs and rip cord, Double outlet The length of telephone cable upto 07 meter length or less as per site condition. Complete all as specified and directed. Note : PVC Conduit should be measured seperately in respective items
M&L for point wiring with Coaxial cable copper conductor FRLSH, P.V.C. insulated and sheathed , anti termite, colour coded twisted pairs and rip cord, Double outlet The length of coaxial cable upto 07 meter length or less as per site condition. Complete all as specified and directed. Note : PVC Conduit should be measured seperately in respective items
Supply and fixing modular telephone jack RJ-11, ISI marked white colour fixed in 1 M box fitted in Robust designed assembly plates smug fit on the wall, Dust Free Glossy Finish including pressed GI concealed terminal boxes not less than 1.6 mm thick, inner plate and outer cover, finger proof terminals with captive screws having front fixing & removing features without removing plates complete all as specified.
Supply , installation, testing & commissioning of single phase two wire, 240 volts, 10-60Amps, accuracy class1.0 with transparent polycorbonate box BIS makin, single source Pre-payment meter, having dual facility of meter reading with hand held meter reading instrument including customer interface unit and having ABC code and inbuilt control switch for disconnection facilities with telephone wire drawing concealed PVC conduit medium grade of suitable size complete all as specified and directed.
Supply and fixing modular TV socket (RG-06), ISI marked, white colour fixed in 1 M box, fitted in Robust designed assembly plates smug fit on the wall, Dust Free Glossy Finish including of pressed GI concealed terminal boxes not less than 1.6 mm thick, inner plate and outer cover, all conforming to IS 3854 :1997 with finger proof terminals with captive screws having front fixing & removing features without removing plates complete all as specified.
LIGHTENING PROTECTION Materials and labour as in replacement for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel strip 32x6 mm as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm GI pipe medium grade for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel strip 25x4 mm as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 32mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
REFRIGERATOR/DEEPFREEZER/WATER COOLER : Supply & fixing for Refrigerator with in-built stabilizer of capacity 310 liter ,230 volt, AC, 50 Hz , electric driven, single phase, frost free, smart inverter operation and as per latest BEE 5 star rated complete all as specified and directed.
Supply and fixing of metal Top Deep Freezer single phase 240 volt, 50 Hz of capacity 320 Ltr, BEE 5 Star ratings, double door, complete all as specified and directed. star rated, complete all as specified and directed.
Supply, installation, testing & commissioning of Water cooler fully Stainless steel (SS 304 grade), electric driven single phase 230 volt, 50 Hz having storage capacity 80 Ltrs & and nominal cooling capacity 40 Ltrs per hour, 100% copper cooling , as per latest version including connection by means of water pipe line, inlet and outlet, PVC pipe connection with brass coupling, nuts at both ends and other necessary fittings including necessary electric connection with and including plug top 15 Amps from voltage stabilizer to water cooler complete all as specified and directed.
Supply and fixing of heavy duty desert cooler PVC body,3-side high efficiency honeycomb pads with dust filters for pure healthy air, Robust weather resistant body for long life, Digital touchscreen & full function remote, Powerful 3 speed fan and empty water-tank alarm, Easily removable and cleanable cooling pads. Fully closable horizontal louvers, Float valve for auto water filling and lockable heavy-duty wheels, 110 m³/hr air delivery low power consumption - 185 watts, storage capacity of tank should not be less than 75 litres complete all as specified and directed.
DG SET & VOLTAGE STABILIZER Supply, installation, commissioning and testing (load trail) of Diesel Engine driven Generating set of capacity 100 KVA as per IS -4722 with AMF panel (Auto mains failure ) recommended by DG set manufacturer , type 415 Volt 3 phase 4 wire system complete with relay panel for automatic starting on mains failure control panel having meters and floor mounted including acoustic enclosure canopy to ensure pollution free complying with all latest CPCB IV norms for pollution and noise with specification as per Annexure 'B' to item No 16.02 of BOQ .
Supply, Installation, commissioning & Testing of automatic out door type servo controlled voltage stablizer of capacity 100 KVA, Three phase, IP 55 Protection, 50 Hz Naturally Oil cooled type BIS certified, unbalanced type, copper wound, metallic body duly power coated with lifting hooks, digital display, relay free smooth and silent operation with 1st filling of Transformer oil up to level, stablizer shall conform to BIS 9815 Pat 1-1994 and having specifidation as per Annexure 'A' to item No 16.03 of BOQ .
FLOOD LIGHT AND HIGHWAY LIGHT FOR HANGER Supply and fixing LED flood light 70 watt, 230 V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with electronic driver and lamp and average life of flood light should not be less than 50000 hours, including clamps, nut, bots, ETC, complete all as specified and directed. Note : The contractor shall submit two years of warranty of LED light fittings from the manufacturer alongwith Purchase Voucher
M&L for Submain wiring with two single core FRLSH 2.5 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including FRLSH 2.5 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and con-nection to earth dolly complete all as specified. (for connection to flood light and Higbay light) Note:- Two single core FRLSH 2.5 sqmm copper conductor, one run PVC conduit and one run of FRLSH 2.5 sqmm earth wire shall be considered & measured as one unit. In case of roof/ceiling, Stove enamelled conduit shall be used without any extra cost.
Supply and fixing MCB SPN 32 Amp rating 240V, 10KA 'C' curve and current carrying ca-pacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB TPN Isolator 100 Amp rating 415V, 10KA 'C' curve and current carrying ca-pacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
SAR AGENCIES (BID ID -3088815)
M/S JAWAHAR LAL SHARMA (BID ID -3090034)
MAGO CONSTRUCTION PVT. LTD. (BID ID -3089631)
Aalaya Engineering Project Private Limited (BID ID -3077412)
SARAOGI BUILDERS LIMITED (BID ID -3086037)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid