| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.6 L+₹5.2 L (19.0%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹32.9 L+₹5.5 L (20.0%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹37.9 L+₹10.5 L (38.3%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹43.6 L
EMD Value
₹87,300
Closing Date
6 Jan 2024, 6:00 pmClosed
GE Faridkot
GE Faridkot Military Station
Special repair to Bldg No P-21 alongwith VIFT wall at SASF at Faridkot Mil Stn
2023_MES_633120_1
GE FRD-74/2023-24
Open Tender
Civil Works
Item Rate
240 days
GE Faridkot
Class D Category a i
9 documents required · 9 mandatory
₹500
GE Faridkot
₹87,300
Yes
20 Jan 2024
16 Dec 2023
8 Jan 2024
16 Dec 2023
6 Jan 2024
23 Dec 2023
Amount
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed
M&L for plain cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in hardstanding,ramp,plateform etc,to be placed in alternate way,surface finished even and fair without using extra cement complete all as specified and directed .
M&L for hard core of gauge not exceeding 63mm using broken stone or boulders, deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed .
M&L for 75 mm thick cement concrete 1:3:6 type C2( using 40mm graded crushed stone aggregates) as in plinth protection/path finishing surfaces even and fair complete all as specified and directed .
M&L for forming construction joints 30mm deep x 10mm wide, filled with sealing compound, grade 'A' complete all as specified and directed .
M&L for 40mm thick, PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregates), as in flooring ,finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for 100mm thick, PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregates), as in sub base of flooring ,finishing surfaces even and rough without using extra cement complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks using old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed .
Taking down cement plaster from brick walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping,bed blocks, seismic and other similar bands and similar works including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 mixed with WPC on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed . Note : WPC will be measured and paid separately
M&L for rendering 15 mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 10 mm thick in cement mortar 1:3 on ceiling, finished even and smooth without using extra cement complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 Cement : 4 Coarse Sand) the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square meter, top layer 15mm cement Plaster 1:1/2:2 (1 Cement : 1/2 Coarse sand : 2 Stone chipping 10mm nominal size) in panels with grooves all round as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed. Note : Payment for providing grooves shall be made separately)
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
M&L for preparation of newly plastered or unplastered surfaces of wall by applying one coat of exterior wall care putty and applying two coats of weather proof exterior emulsion paint (camouflage pattern) over and including one coat of exterior primer complete all as specified and directed.
M&L for complete removal of existing treatment of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts,treating oil and greasy spots & preparation of surfaces by applying one coat of wall care putty and applying two coats of weather proof exterior emulsion paint (camouflage pattern) complete all as specified and directed.
M&L for preparation of old surfaces of walls including brooming down or steel wire brushing, scrapping down smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots and applying two coats of cement base paint complete all as specified and directed .
M&L for preparation of old decorated surfaces of any description wood,steel, iron, concrete,brick,stone etc exceeding 10cm in width or girth and applying two coats of fire resisting paint over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered or unplastered ceiling surfaces and applying two coats of white wash complete all as specified and directed .
M&L for preparation of old plastered or unplastered ceiling surfaces and applying two coats of white wash complete all as specified and directed .
M&L for taking down mild steel door shutter of size not exceeding 15 Sqm ,welding as required,denting the surfaces as required, cleaning and greasing & oiling properly to make the door smooth /easy functional and refixing the shutter in the existing position complete all as specified and directed .
Taking down old deteriorated concrete /plaster of old surfaces of facia,parapet,slab edges,projection bottom etc & applying 15mm thick rendering in cement mortar 1:3, finishing surfaces even and smooth without using extra cement including necessary scaffolding,doubing coat complete all as specified and directed. Note:-Work is to executed in buildings of height upto 15 metres and Quoted rate of the item is deemed to included the same.
Demolition of roof padding including mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of )floors,beams,chajjas & similar suspanded works and disposal of retrieved material to a distance n.exc 100m from the starting point complete all as specified and specified
Supply only integral water proofing compound
M&L for supply of approved earth from outside defence land and forming embankments including raising or lowering by approved earth ,spreading in layers not exc 30cm thick each layer, watering, ramming/rolling and finishing to required level, size and shape etc complete all as specified and directed.
M&L for Cutting upto a depth of 5.0cm into concrete walls and trimming surface as required,girth exc. 30cm complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches/in floors/fixed to walls including fixing clamps with nut and bolts complete all as specified and directed .
S&F PVC (SWR) bends, any radius ,110mm bore complete all as specified and directed.
Demolition of cement concrete (reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape as required, including cranking, bending and binding with & including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed .
M&L in repair for RCC 1:2:4, type B1 (using 20mm graded crushed stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies and in shelves complete all as specified and directed.
M&L for use and waste of form work to soffits of suspended slab such as roof slabs, not exceeding 200mm thick, horizontal or sloping complete all as specified and directed .
M&L for Roof Treatment as specified below and as directed : (a) Cleaning, washing of surface and removing all existing bitumen coatings/ APP membrane completely with intense wire brushing or high speed water jet. Surface should be free from any loose paint, dust or grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Applying one coat of PrimeSeal/ Epoxy Primer/ShaliUrethane BTD White diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm (0.20 kg BTD+0.20 Kg water) (d) Laying polyster reinforced fiber net/50 gsm Geotextile mesh, upto 300 mm on walls. (e) Applying three coat of HydroShield PUD microfibre reinforced UV resistent polyurethane (solid content 68% ) / Damp Proof ultra UV Stable fibre reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers (Solid content 55%)/ SmartCare PU Magnum elastomeric waterproofing coating based on hydrophobic polyurethane (solid content 85%)/Single Component Elastomeric Liquid Membrane ShaliUrethane BTD White/coloured (Elongation 400% ± 50, Solid Contents > 80% & Specific Gravity @ 30 OC 1.5 ± 0.03) @ total 2.00 Kg per sqm in two coats for maintaining thickness of 1.5mm, with paint brush/ roller upto 300 mm on walls. (f)) Complete treatment to be carried out by authorised applicator of waterproofing manufacturer. Note (i) The treatment shall be carried out as per the manufacturer's instructions, and as directed by Engineer-in-Charge. (ii) The plan area of floor shall be considered for payment.
M & L for Shotcreting average thickness 40mm in RCC columns, beams and slab etc. (with mix minimum cement content of 350 Kg per Cum, M-25). Concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregates of 6mm maximum size in proportion as per design criteria) incl the cost of centering and shuttering at edges and corner etc as directed by Engr-in-Charge including chipping of unsound/week concrete material 50mm average thickness from slabs, beams/columns etc with mannual chiesels or standard power driven percussion type or of approved make incl tapering of all edges, make square shoulder of cavities incl cleaning the exposed concrete surface and reinforcement with wire brushes and throughly washing with water and allowing it to dry etc incl removel of rust by applying approved rust remover chemical and the coating with Dr Fixit Epoxy zinc primer @ 6 Sqm per Litre at DFT of 100 micron as per specification, applying the SBR Latex based bonding agent on each layer of the shootcreting work of Dr Fixit Pidicrete URP on the entire surface complete all as directed including 5mm thick cement plaster in CM(1:3) finished even and smooth without using extra cement including removing rubbish material from building and thrown in low lying empty area at any distance upto 500 metres from the site complete as specified and as directed by Engineer-in-Charge. Make :- Sika / Fosroc/Pidilite or Techno commercial equivalent make approved by GE Note : Complete treatment to be executed by approved applicator.
S&F hard drawn steel wire fabric not exc 4kg/sqm cut to lengths, wire mesh to be fixed and firmly anchored to the concrete surface by means of 'L' shaped mild steel shear key welded with existing reinforcement including cost of material, labour, tools and plants including welding/L-clip/tying with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls in weep holess complete all as specified and directed .
S&F Roof trusses (framed), trussed, purlins, crane gantries rails and fastening and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc ,fixing with fasterners/welding or clamping confirmimg to Fe 290 (Gde E -165) complete all as specified and directed
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in roof padding including necessary formwork complete all as specified and directed.
Taking down carefully existing aluminium/copper point wiring for light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells & making good the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed. Note : Rate for making good shall be deemed to be included in above item rate.
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including stove enamelled steel conduit of suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earth point dolly for for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed .
All as per Srl item No. 41 here-in-before for Switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed .
Supply and fixing LED light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed .
S&F in repair Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed .
S&F in repair Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A,250V, 2P+earth complete all as specified and directed.
S&F in repair Flame & weather proof Sheet metal enclosure for DBs,SPN, double door, 230 Volts,8 ways with 200 amps rated bus bar including one MCB SPN & 06 Nos MCB SP complete all as specified and directed .
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
S&F in repair GI pipe, light grade, 40mm bore, for cable protection, fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid separately.
Excavation in trenches in any type of soil not exceeding 1.5m deep and 1.5m wide, for foundation etc or manholes,piers,shafts etc not exceeding 10 Sqm on plan and getting out complete all as specified and directed.
Returning, filling in,including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed .
Removal of surplus soil to a distance not exceeding. 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed .
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, including taking out existing one complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
S&F in repair air termination rod ,12 mm dia, single pointed, 300 mm long fixed to angle iron 40mmx40mm x 6mm with flat iron clamp of size 25mmx3mm, embedded in PCC 1:2:4 type B-1(using 20mm graded crushed stone agreegates) block of size 200mmx200mmx300mm complete all as specified and directed .
S&F in repair aluminium strip 25mmx3.15mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed
Material & labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6mm galvanised iron strip complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of galvanised iron strip 32mmx6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 50mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 1500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
M&L in repair for test points terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos, 8mm dia, 25 mm long hexagonal screw complete all as specified and directed .
S&F GI pipe, light grade, 40mm bore, for cable protection, fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid separately.
M &L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in Block of size 25 cm x 25cm and height 30cm, providing 02 Nos. MS fastner at the top of the block by using 8/9mm dia 20cm long bolts with T junction of 10cm & embeded in the PCC block, keeping 7 cm portion of the bolt above the upper surface of PCC block alongwith 02 Nos washers and nuts etc complete all as specified and directed .
S&F wooden block of locally available 2nd class hard wood of size 25 x 10 x 5cm for mounted on top of PCC block for errection of air termination alongwith bolts and nuts and run the roof conductor complete all as specified and directed. Note :- A Sum of Rs. 14,275.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 25 (Schedule of credit) of Tender Documents.
NEW AMRITSAR CONSTRUCTION COMPANY
BANSAL BUILDERS
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .