Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹7.9 L
EMD Value
₹15,800
Closing Date
15 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
RnB Division Karan Nagar Srinagar
Strengthening of Security Apparatus at Amar Niwas Complex Srinagar
2025_PWDJK_297030_2
etendering NIT No. 51 Karan Nagar Sgr
Open Tender
Civil Works
Percentage
30 days
Amar Niwas
Please refer Tender documents.
4 documents required · 4 mandatory
₹300
Executive Engineer
₹15,800
13 Jan 2026
2 Dec 2025
16 Dec 2025
2 Dec 2025
15 Dec 2025
2 Dec 2025
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position Budloo / Fir wood
Providing and fixing Imported wooden panelling high tech knotted of approved make, design including labour, material, wastage, carriage make rait wood including fixing of framework of 10mm ply on walls and fixing in position including cost of screws, nails, etc as per the direction of Engineer incharge at the time of execution including applying of touchwood of approved brand complete job all inclusive
Varnishing with varnish of approved brand and manufacture Two or more coats of glue sizing with spar varnish on an under coat of flatting varnish
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge In cement mortar
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 meters lead Thickness above 25 mm upto 40 mm.
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) including all carriages leads lifts complete job.
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level including all carriages leads lifts complete job.
12mm Cement plaster of mix 1 : 6 ( 1 cement : 6 fine sand)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete 25mm thick with 12.5 mm nominal size stone aggregate.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Supplying, installation, Testing & Commissioning of Flood Light, powdercoated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.?0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMCas per CISPR -15 , lenses for beam angle 30 deg-120deg as per theapplication and the project requirement deg., suitable tilt able fitting, life time(LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (Asper ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximumpower consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above90°C). 50Watt
Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.?0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthling etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ?120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).sioning /handing over of site to intending department. Powder coated die cast /Extruded aluminum Body including trim with Aluminum Reflector. 12-15Watt
Point wiring for 16 Amp Socket out lets ( Two out lets wired in one sub circuit ) with 3x4 sq mm (P+N+E) FRLSH PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Polycab/Finolex/Anchor/ Havells /Para flex make, to be laid in recessed or surface conducting system (including cost of 25 mm dia ,2 mm thick PVC conduits of polycab /Anchor /finolex /Ravendera green make with allied accessories like bend ,ties ,binding wires ,including cutting of walls and refacaing of same with cement concrete or pop after laying of conduits complete job. )) and including the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch with modular cover plate of Schneider /ABB /L&T /Legrand make , complete as per specification and as required to be provided & fitted on GI boxes with inter connection complete as per specifications and as required (including Cost of GI Boxes ,Switches ,sockets ,plates etc ) . The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit (Maximum two points shall be connected / provided in one circuit and no extra circuit wiring shall be paid what so ever reason or length) (including cost of conduits)
Supply, Installation testing and commissioning of 250-300 mm sweep Shutter type Exhaust Fans of Usha / Crompton Greaves / Havel's with way ceiling rose of SSK make incl making of necessary connections and making of necessary space in walls / Windows as per site.
Supply, Installation, Testing and Commissioning of 900-1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, long down rod upto 90 cms . canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/\N) minimum 6.00,Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (ma><.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthling etc. complete as required.(Crompton / USHA / Havels /Helonix make)
Engagement of Unskilled labours for various miscellaneous works at site as directed by Engineer Incharge
Engagement of skilled labours for various miscellaneous works at site as directed by Engineer Incharge
Engagement of vehicle for disposal of mulba, rubbish material, etc beyond Municipality limits as directed by Engineer Incharge
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.37 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.53 MB
BOQ_962614.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .