Loading…
Loading…
Tender Value
₹5.6 L
EMD Value
₹11,110
Closing Date
28 Sept 2026, 3:00 pm6d left
Execuitve Engineer (E)
BSNL ED SVP
Attending electrical faults at various TE/BTS under Carnicobar Sub Division, Carnicobar.
2026_BSNL_291196_1
31/ED/SVP/2026-27
Open Tender
Electrical Works
Item Rate
60 days
Sri Vijaya Puram
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
Accounts Officer Cash
₹11,110
Yes
17 Sept 2026
17 Sept 2026
29 Sept 2026
17 Sept 2026
28 Sept 2026
17 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing of following ways surface/ recess mounting, Vertrical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) = (8+ 12) way, | 2 | Nos | - | - |
| 2 | Replacement of defective 100 A, 3 pole MCCB of breaking capacity 25 KA with thermal releas 80-100 A or above, suitable for 415V, 50 Hz, AC supply, and fixing the new one, i/c connection the existing cables, testing, commissioning, etc. as reqd. (Make - M/s, L&K, Type DN0-100C 0f L&K or similar superior). | 4 | Nos | - | - |
| 3 | Replacement of defective 200 A, 3 pole MCCB of breaking capacity 25 KA with thermal releas 160-200 A or above, suitable for 415V, 50 Hz, AC supply, and fixing the new one, i/c connection the existing cables, testing, commissioning, etc. as reqd. (Make - M/s, L&T, Type DN1-250C of L&K or similar superior). | 1 | Nos | - | - |
| 4 | Replacement of faulty changeover switch 125 A, 4P panel mounted in the main LT panel after removing the faulty unit from LT panel and fixing the new one of sheet enclosure same quality, making connection, testing, commissioning etc complete as reqd. ( Make: Havells , Model: FR2 of L&K or SS) | 1 | Nos | - | - |
| 5 | Replacement of faulty 100A TPN Switch disconnector fuse unit in SS enclosure with new one of same capacity i/c connection testing commissioning etc complete as reqd. (make: L&K or SS) | 2 | Nos | - | - |
| 6 | Supplying and fixing following accessories in the existing DB/Panel including connections etc as required. Single pole ( 6 to 32 A) | 28 | Nos | - | - |
| 7 | SPN (6-32A) | 3 | Nos | - | - |
| 8 | 4 Pole Isolator (100A) | 2 | Nos | - | - |
| 9 | S/F of 5A Paino type switch on existing switch board including connection complete as reqd. | 40 | Nos | - | - |
| 10 | Supplying and fixing LED type 4 ft light fitting of 20 Watt, 230V, 50HZ, including making all electrical connections with suitable size PVC insulated copper conductor wire etc. as required (M/s Crompton/Havells or SS make) | 10 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.54 MB
BOQ_339569.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .