Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC 38A PHASE II RAVINDRA ENCLAVE BALTANA PB | ₹2.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.7 LRejected-Finance 0 A K ENTERPRISES SADAR ROAD BALOD GANGA MAIYA BOOK DIPO NEAR BALOD CHHATTISGARH 491226 UDYAM CG 17 0002983 | BALOD | CHHATTISGARH | 491226 | ₹2.7 L | L2 | Rejected-Finance not L1 |
| 3 | L3₹2.8 LRejected-Finance 1090 GROUND FLOOR SECTOR 18 C CHANDIGARH | ₹2.8 L | L3 | Rejected-Finance not L1 |
Tender Value
₹4.2 L
EMD Value
₹8,311
Closing Date
12 Jan 2026, 11:00 amClosed
Executive Engineer, Electrical Division, M.C., Chd
Executive Engineer, Electrical Division, M.C., Chd
Providing Wall Bracket lights with Junction Box in internal road/ gallies village Burail, Chandigarh. Ward No. 33
2026_MCC_89904_1
02/E/MCC/2026
Open Tender
Electrical Works
60 days
Providing Wall Bracket lights with Junction Box in
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹8,311
10 Apr 2026
5 Jan 2026
12 Jan 2026
5 Jan 2026
12 Jan 2026
5 Jan 2026
Wall Bracket: S/E of 32mm dia x 1m long G.I. Pipe (Medium Class) Pole Arm/ Bracket for mounting LED Street Lighting/Fitting on pole including bending the pipe of the required shape (90 to 105 deg), 2 nos. required size (suitable for cemented and circular pole) Flat Iron Clamps with Nut, Bolts and Washer. G.I. Coating/ Painting the flat iron with primer and finish paint as per relevant tender specifications or other material required to fix the bracket and work must be completed to the entire satisfaction of Engineer-in-charge. The bracket is to be fixed on wall with the help of M.S. Clamps including welding and drilling of holes and complete in all respect including labour and other petty items required to complete the job upto the entire satisfaction of the Engineer-in-Charge. The Make of the G.I. pipe should be of Tata/ Jindal/ Hissar or Ravindra.
Supply, Installation, Testing and Commissioning of Polycarbonate Junction box shall be insulated and made out of Polycarbonate with glass fiber reinforced. The size in mm should not be less then 155 x 210 x 92 cat. Part no KF1616. The Polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The Jb shall be rated for Degree of Ingress Protection IP 66/67 in accordance with IEC 60529. The gasket material shall be Polyurethane and the gasket shall be internally embedded. The JBs shall be comples with requirements of the Standards IEC 60998-1, IEC 60998-2-1, IEC 60670 - 22 & 60670 - 2.5. The manufacturer of Junction Box shall submit a copy of IEC Certificate. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-11, DIV VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested and Glow Wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. The connecting terminal cabke entry should be fixed in junction box for incoming and outgoing. The box shall be Hensel/ Siemens/ Schneider/ ABB or its equivalent make only. Manufacturer should submit routine test certificate for CJB/PJB. The job includes Supply and fixing of MS clamp of reqd. size. The clamps is to be fixed on the backside of the box including welding/ drilling of holes complete in all respect and to be fixed on LT- RCC/ Steel tubular pole at as certain height upto the entire satisfaction of Engineer-in-Charge.
Supply & laying PVC insulated Aluminum Conductor armoured ISI Marked cable of 2 Core 10 mm sq in Trench/Pipe. Supply & laying of ISI marked 2 core 10 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheated) of make Havells/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.1 MV CBPIP-25 (external). The job included all Connections, Commissioning and testing of phase including clamping in every 20 meter length for proper dressing, supply complete in all respective to the entire satisfaction of the Engineer in charge. The specification of the cable as below:- i) Conductor – Aluminum ii) Core – 2 iii) Working Voltage – 1100 V iv) Nominal Cross Section – 10mm2 v) Minimum No. of Wire – 7/6 Maximum d.c. Resistance at 20 Deg. C – 1.91 ohm/km The work shall be executed to the entire satisfaction of Engineer-in-Charge.
Supply & Erection of PVC Insulated (sheathed) Copper Conductor Cable ISI marked size 3 core 1.5 mm2. Supply & Erection of ISI Marked PVC insulated 3 core 1.5mm2 cable of Copper Conductor (Sheathed) make Finolex/ Lapp/ Cirtina/ Polycab/ Havell's/ left barel/ Panasonic in pipe of suitable size excluding cost and erection of pipe/pole etc. (i) Cable size 3 core 1.5 mm2 Copper Conductor 1100 Volts Grade. The work shall be executed to the entire satisfaction of Engineer-in-charge.
Supply of Reducer for Wall Bracket (32mm dia x 1m) / RCC Pole (32mm dia x 2m). The work shall be executed to the entire satisfaction of Engineer-in-Charge.
Erection of high power 18 Watt (Max) LED Street Light luminaries on Cemented Pole/ Wall Bracket. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_109941.pdf
BOQ Comparative Chart
xlsx
finsummary_109941.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.27 MB
BOQ_109941.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid