Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹10.1 Cr A B 64 PLOT NO 64 PLOT NO 97 5 OPP MANISH PETROL PUMP NEW PRAKASHA ROAD SHAHADA NANDURBAR | ₹10.1 Cr |
Tender Value
₹10.1 Cr
EMD Value
₹10.1 L
Closing Date
11 Mar 2026, 11:00 amClosed
Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
NBCC/RBG/MAH/NVS/NDB/2026/36
NBCC/RBG/MAH/NVS/NDB/2026/36
Open Tender-Domestic
Civil Works - Buildings
Nandurbar, Maharashtra
₹11,800
₹10.1 L
17 Jul 2026
23 Feb 2026
11 Mar 2026
11 Mar 2026
2 BOQ NANDURBAR
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
DSR-2023 Rate DSR-2022 E/M Rate
Sr.No Description of Item (incl. CF 0.973 + CI (incl. CF 0.973+CI NS AMOUNT Total Cost Remarks
Cost of Building Works
Cost of Development Works
Digitally signed by AMIT JAIN
IST Page 1 of 103
BOQ Summary of Buildings
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
Amount (DSR- Amount (DSR
2023) Civil 2022+GST
S.No Types of Quarters NS AMOUNT Total Cost Building wise
with correction 6.33%) E/M with
factor correction factor
Digitally signed by
IST Page 2 of 103
BOQ- School Building (G+1)
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
1 EARTH WORK -
Earth work in excavation by mechanical means (Hydraulic excavator) / manual
means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm
on plan) including disposal of excavated earth, lead upto 50m and lift upto
2 2.6 1.5m, disposed earth to be levelled and neatly dressed. -
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm in depth, consolidating each
4 2.25 deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. cum 130 196.00 204.058 - 26,512 - -
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/Lindane Emulsifiable concentrate of 20%.
Diluting and injecting chemical emulsion for Post - CONSTRUCTIONAL anti-
termite treatment (excluding the cost of chemical emulsion)
Treatment of soil under existing floors using chemical emulsion @ one litre per
hole, 300 mm apart including drilling 12 mm dia holes and plugging with cement
mortar 1:2 (1 cement :2 coarse sand ) to match the existing floor.
With Chlorpyriphos /Lindane E C. 20% with 1% concentration.
10 4 CONCRETE WORK - - - - -
11 4.1 Providing and laying in position cement concrete of specified grade excluding the - - - - -
cost of cantering and shuttering - All work up to plinth level
12 4.1.8 1:4:8(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal cum 102 6,812.00 7,092.041 - 7,22,859 - -
Providing and laying damp-proof course 40 mm thick with cement concrete
13 4.10 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal Sqm 184 410.85 427.740 - 78,704 - -
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3
manufactured sand (zone-III) derived from natural sources : 6 graded stone
aggregate 20 mm nominal size derived from natural sources over 75mm thick
bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and
14 4.17 grouted with fine sand, including necessary excavatin, levelling & dressing & Sqm 280.00 749.30 780.104 - 2,18,429 - -
finishing the top smooth.
16 5.9 Centring and shuttering including strutting, propping etc. and removal of form - - - - -
Foundations, footings, bases of columns etc. for mass concrete. sqm 508 392.15 408.271 - 2,07,471 - -
Walls(any thickness) including attached pilasters, butteresses, plinth and string co
19 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 1,190 927.25 965.369 - 11,48,789 - -
Digitally signed by AMIT JAIN
IST Page 3 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Lintels, beams, plinth beams, girders, bressummers and cantilevers.
Columns, Pillars, Piers, Abutments, posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending,
22 5.22 placing in position and binding all complete above plinth level. - - - - -
23 5.22.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 21,353 107.85 112.284 - 23,97,539 - -
Steel reinforcement for R.C.C. work including straightening, cutting, bending,
24 5.22 A placing in position and binding all complete above plinth level. - - - - -
25 5.22A.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 26,751 107.85 112.284 - 30,03,752 - -
Providing and laying in position ready mixed M-25 grade concrete for reinforced
cement concrete work, using cement content as per approved design mix,
manufactured in fully automatic batching plant and transported to site of work in
transit mixer for all leads, having continuous agitated mixer, manufactured as
per mix design of specified grade for reinforced cement concrete work, including
pumping of R.M.C. from transit mixer to site of laying , excluding the cost of
cantering, shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability as per
direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less
cement used as per design mix is payable/recoverable separately).
27 All works upto plinth level - - - - -
28 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 186 9,504.75 9,895.49 - 18,37,335 - -
29 All works above plinth level upto floor V level - - - - -
31 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 233 9,860.40 10,265.76 - 23,88,034 - -
33 6 MASONRY WORK - - - - -
Brick work with common burnt clay F.P.S ( non modular ) bricks of class
34 6.1 designation 7.5 in foundation and plinth - - - - -
Cement mortar 1:6 (1 cement: 6 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every
36 6.15 third course of half brick masonry. sqm 104.8 109.11 - - - -
Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in
superstructure above plinth level up to floor five level in :
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt
39 6.44 clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with Metre 59.45 61.89 - - - -
cement mortar 1:4 (1 cement : 4 fine sand).
40 6.45 Half brick masonry with non modular fly ash bricks of class designation 10, - - - - -
conforming to IS: 12894, in superstructure above plinth up to floor V level.
42 8 CLADDING WORK - - - - -
Digitally signed by AMIT JAIN
IST Page 4 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Providing and fixing 18mm thick gang saw cut mirror polished remoulded and
repolished) machine cut for kitchen platforms, vanity counters, window sills ,
facias and similar locations of required size of approved shade, colour and
texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse
sand) with joints treated with white cement, mixed with matching pigment,
43 8.2 epoxy touch ups, including rubbing, curing, moulding and polishing to edges to - - - - -
give high gloss finish etc. complete at all levels.
44 8.2.3 Granite stone slab of all colourand texture expect black,Cherry/ Ruby Red - - - - -
Providing edge moulding to 18mm thick marble stone counters, Vanities etc.
including machine polishing to edge to give high gloss finish etc. complete as
46 8.3 per design approved by Engineer-in-Charge. - -
Extra for fixing marble /granite stone, over and above corresponding basic item,
in facia and drops of width up to 150 mm with epoxy resin based adhesive,
48 8.4 including cleaning etc. complete. metre 24 568.55 591.923 - 14,206 - -
Extra for providing opening of required size & shape for wash basins / kitchen
49 8.5 sink in kitchen platform, vanity counters and similar location in marble / Granite Each 20 978.70 1,018.934 - 20,379 - -
/ stone work including necessary holes for pillar taps etc. Including rubbing and
polishing necessary etc. complete.
50 9 WOOD AND P.V.C WORK - - - - -
Providing and fixing 19 mm thick both side balancing laminationfactory pressed
BWP grade marine ply as per IS : 710 of approved brand
51 9.169 boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary Sqm 2593.15 2,699.754 - - - -
nails,screws etc. complete as per direction of Engineer-incharge
Providing and fixing ISI marked flush door shutters conforming to IS: 2202
(Part I) non-decorative type, core of block board construction with frame of 1st
class hard wood and well matched commercial 3 ply veneering with vertical
52 9.21 grains or cross bands and face veneers on both faces of shutters : - - - - -
53 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary sqm - 2,392.65 2,491.012 - - - -
54 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum sqm - 462.35 481.357 - - - -
depth on all edges of flush door shutters (over all area of door shutter to be
Providing and fixing M.S. grills of required pattern in frames of windows etc.
with M.S. flats, square or round bars etc. including priming coat withapproved
55 9.48 steel primer all complete. - -
56 9.48.1 Fixed to steel window by welding kg 1134.00 219.1 228.107 - 2,58,674 - -
Providing & fixing bright finished brass 100mm mortice latch and lock with 6
levers and a pair of lever handles with necessary screws etc. complete (Best
57 9.76 make of approved quality). Each 40 854.65 889.785 - 35,591 - -
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic
58 9.96 coating not less than grade AC 10 as per IS: 1868) transparent or dyed to - - - - -
required colour or shade with nuts and screws etc. complete:
Digitally signed by AMIT JAIN
IST Page 5 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating
60 9.97 not less than grade AC 10 as per IS : 1868 ) transparent or dyed toreqired - - - - -
colour or shade with necessary screws etc.
Providing and fixing aluminium handles ISI marked anodised (anodic coating not
62 9.100 less than grade AC 10 as per IS : 1868) transparent or dyed to required colour - - - - -
or shade with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper ISI marked anodised
(anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed
64 9.101 to required colour or shade with necessary screws etc. complete: - - - - -
Providing & fixing special quality bright finished brass Cupboard or ward robe
locks with four levers including necessary screws etc. complete (best make of
66 9.79 approved quality). - - - - -
68 9.91 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs Each 40 151.5 157.728 - 6,309 - -
with nuts complete.
Providing and fixing magnetic catcher of approved quality in cupboard / ward
robe shutters, including fixing with necessary screws etc. complete.
70 9.114.2 Double strip (horizontal type) Each 40 39.7 41.332 - 1,653 - -
Providing & Fixing decorative high pressure laminated sheet of plain / wood
71 9.127 grain in gloss / matt / suede finish with high density protective surface layer and - - - - -
reverse side of adhesive bonding quality conforming to IS : 2046 Type S,
including cost of adhesive of approved quality.
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows
and clerestory windows using wire gauge with average width of aperture 1.4
73 9.135 mm in both directions with wire of dia. 0.50 mm all complete. - - - - -
74 9.135.2 With 12 mm mild steel U beading sqm 1,228.00 1,278.483 - - - -
Providing and fixing factory made single extruded WPC (Wood Polymer
Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat
comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium
carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non
toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter
joints after applying PVC solvent cement and screwed with full body threaded
star headed SS screws having minimum frame density of 750 kg/cum, screw
withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive
strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to
spread of flame of Class A category with property of being termite/borer proof,
75 26.86 water/moisture proof and fire retardant and fixed in position with M.S hold - - - - -
fast/lugs/SS dash fasteners of required dia and length complete as per direction
of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid
for separately).
Digitally signed by AMIT JAIN
IST Page 6 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Note: For WPC solid door/window frames, minus 5 mm tolerance in profile
dimensions on plus side shall be acceptable but no extra payment on this
account shall be made
Providing and fixing factory made single extruded WPC (Wood Polymer
Composite) solid board one side white color and other side of board laminited
with pvc foil of minium 14 micron thickness of approved design pasted with hot
melt adhesive for cup boards,work station and bathroom /kitchen cabinet etc.of
required sizes comprising of virgin polymer of K (value 58-60 (suspension grade
), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk)
and non toxic additives (maximum toxicity index of 12 for 100 gms) having
minimum density of 650 kg/cum and screw withdrawal strength of 1800 N
78 26.89 (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of - - - - -
elasticity 850 N/mm2 and resistance to spread of flame of Class A category with
property of being termite/borer proof, water/moisture proof and fire retardant
and fixing with stainless steel piano hinges /soft close clip on concealed hinges
of required size with necessary full body threaded star headed counter sunk S.S
screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano
hinges/soft clip on concealed hinges and necessary S.S screws shall be paid
80 NS-18 Providing and fixing Magic eye with all respect complete. Each 4.00 - - 164 - - 657.81
Providing and fixing pressed steel door frames conforming to IS: 4351,
manufactured from commercial mild steel sheet of 1.60 mm thickness, including
hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle
of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or
rigidly fixed together by mechanical means, including M.S. pressed butt hinges
82 10.14 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as - -
specified and applying a coat of approved steel primer after pre-treatment of
the surface as directed by Engineer-in-charge:
83 10.14.3.1 Fixing with adjustable lugs with split end tail to each jamb (Profile E) metre 6 640.20 666.519 - 3,999 - -
84 10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb (Profile B) metre 6 583.30 607.279 - 3,644 - -
85 10.14.2.1 Fixing with adjustable lugs with split end tail to each jamb (Profile C) metre 6 611.75 636.899 - 3,821 - -
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and
cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet,
joints mitred, welded and grinded finish, with profiles of required size, including
86 10.15 fixing of necessary butt hinges and screws and applying a priming coat of - - - - -
approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block kg 195.20
87 10.15.1 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone 203.225 - - - -
aggregate 20 mm nominal size)
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling
fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S.
88 10.18 sheet with its top surface hacked for proper bonding, top lid shall be screwed Each 24 220.65 229.721 - 5,513 - -
into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed
screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar
bent to shape as per standard drawing.
Steel work welded in built up sections/ framed work including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer using
structural steel etc. as required.
Digitally signed by AMIT JAIN
IST Page 7 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Structural steel work in single section, fixed with or without connecting plate,
including cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer all complete
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash
fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2),
counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve,
91 10.27 including drilling of hole in frame , concrete/ masonry, etc. as per direction of - - - - -
Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,
channels, plates etc., including welding, grinding, buffing, polishing and making
curvature (wherever required) and fitting the same with necessary stainless
steel nuts and bolts complete, i/c fixing the railing with necessary accessories &
93 10.28 stainless steel dash fasteners , stainless steel bolts etc., of required size, on the Kg 594 772.40 804.153 - 4,77,667 - -
top of the floor or the side of waist slab with suitable arrangement as per
approval of Engineer-in-charge, (for payment purpose only weight of stainless
steel members shall be considered excluding fixing accessories such as nuts,
bolts, fasteners
94 11 FLOORING WORK - - - - -
Marble stone flooring with 18mm thick marble stone as per sample of marble
95 11.23 approved by Engineer-in-charge over 20 mm (average) thick base of cement - - - - -
mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry
including rubbing and polishing complete with :
96 11.23.2 Raj Nagar plain - - - - -
97 11.24 Extra for pre finished nosing to treads of steps of marble/granite stone. metre 719.9 749.495 - - - -
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed
98 11.26 with grey cement slurry mixed with pigment to match the shade of the slab, - - - - -
including rubbing and polishing complete with base of cement mortar 1 : 4 (1
cement : 4 coarse sand) :
Kota stone slabs 20 mm thick in risers of steps, skirting,dado and pillars laid on
12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and
jointed with grey cement slurry mixed with pigment to match the shade of the
100 11.27 slabs, including rubbing and polishing complete. sqm 37 2,354.70 2,451.502 - 90,644 - -
Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08%
andconforming to IS: 15622, of approved brand & manufacturer, in all
coloursand shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4
coarsesand) jointing with grey cement slurry @3.3 kg/sqm including grouting
thejoints with white cement and matching pigments etc. The tiles must be
101 11.41A cutwith the zero chipping diamond cutter only . Laying of tiles will be donewith - -
the notch trowel, plier, wedge, clips of required thickness, levelingsystem and
rubber mallet for placing the tiles gently and easily.
Double charge vitrified tile polished finish of size
Digitally signed by AMIT JAIN
IST Page 8 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Providing and laying Polished Granite stone flooring in required design and
patterns, in linear as well as curvilinear portions of the building all complete as
per the architectural drawings with 18 mm thick stone slab over 20 mm
104 11.56 (average) thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) laid and - -
jointed with cement slurry and pointing with white cement slurry admixed with
pigment of matching shade including rubbing , curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge
105 11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby sqm 3,071.05 3,197.301 - - - -
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved
106 11.21 make and colour using acid and/or alkali resisting mortar bedding, and joints - -
filled with acid and/or alkali resisting cement as per IS : 4457, complete as per
the direction of Engineer-in- Charge.
107 11.21.1 In flooring on a bed of 10 mm thick mortar 1 :4 (1 acid proof cement : 4 coarse - -
108 11.21.1.1 Acid and alkali resistant tile sqm 1,738.15 1,809.605 - - - -
109 11.21.2 In dado/skirting on 12 mm thick mortar 1 :4 (1 acid proof cement : 4 coarse - - - - -
110 11.21.2.1 Acid and alkali resistant tile sqm 1,884.90 1,962.388 - - - -
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard,
jointed with neat cement slurry mixed with pigment to match the shade of tiles,
111 11.20.2 including rubbing and cleaning etc. complete, on 20 mm thick bed of cement SQM 1328.35 1,382.958 - - - -
mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white
112 12 ROOFING WORK - -
Providing and fixing 1 mm galvalume roof sheet AZ-150 ,660 MPA including
113 NS-1 ridge, flashing over lapping etc complete plan area should be measured nothing sqm 700.00 - - 598.01 - - 4,18,605
extra shall be paid for lap, profile. ( valley creast etc)
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm
impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including
cleaning the slab surface with brushes and finally with a piece of cloth lightly
114 12.15 soaked in kerosene oil complete : - -
115 12.15.1 With residual type petroleum bitumen of grade VG -10 sqm 700 166.2 173.032 - 1,21,123 - -
Steel work in built up tubular (round, square or rectangular hollow tubes etc.)
trusses etc., including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer, including welding and bolted with special shaped
washers etc. complete.
118 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm Each 4 54.7 56.949 - 228 - -
diameter and weighing not less than 440 grams.
119 13 FINISHING WORK - -
120 13.4 12 mm cement plaster of mix : - -
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5
(1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster
1:6 (1 cement : 6 fine sand).
123 13.16 6 mm cement plaster to ceiling of mix : - -
Digitally signed by AMIT JAIN
IST Page 9 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Distempering with1st quality acrylic distemper (ready mixed) having VOC
125 13.41 content less then 50 gram/litre of approved manufacture and of required shade - - - - -
and colour complete to achieve even shade and colour.
New work (two or more coats) over and including water tinnable priming coat
with cement primer having VOC content less then 50 gram/litre .
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone
127 13.47 additives of required shade : - - - - -
128 13.47.1 New work (two or more coats applied @1.43 ltr/10 sqm over and including base Sqm 171.10 178.134 - - - -
coat of water proofing cement paint applied @2.20kg/10sqm)
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than
129 13.48A 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, - - - - -
dirt resistance exterior paint of required shade (Company Depot Tinted) with
silicon additives
130 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including Sqm 4,860 181.25 188.701 - 9,17,088 - -
priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Painting with synthetic enamel paint of approved brand and manufacture of
131 13.62 required colour to give an even shade : - - - - -
132 13.62.1 Two or more coats on new work over an under coat of suitable shade with SQM 226.25 235.551 - - - -
ordinary paint of approved brand and manufacture
133 13.68 French spirit polishing : - - - - -
134 13.68.1 Two or more coats on new works including a coat of wood filler sqm 446.25 464.595 - - - -
Providing and applying white cement based putty of average thickness 1 mm,
135 13.80 of approved brand and manufacturer, over the plastered wall surface to prepare sqm 6445.60 156.05 162.465 - 10,47,186 - -
the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having
136 13.83 VOC (Volatile Organic Compound ) content less than 50 grams/ litre of - - - - -
approved brand and manufacture, including applying additional coats
wherever required to achieve even shade and colour.
138 ALUMINIUM WORK - - - - -
Providing and fixing aluminium work for doors, windows, ventilators and
partitions with extruded built up standard tubular sections/ appropriate Z
sections and other sections of approved make conforming to IS: 733 and IS:
1285, fixing with dash fasteners of required dia and size, including necessary
filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM
rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required including cleat
139 21.1 angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel - - - - -
screws, all complete as per architectural drawings and the directions of
Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for
140 21.1.1 For fixed portion - - - - -
Anodised aluminium (anodised transparent or dyed to required shade according
141 21.1.1.1 to IS: 1868, Minimum anodic coating of grade AC 15) Kg 270 495.05 515.402 - 1,39,158 - -
Digitally signed by AMIT JAIN
IST Page 10 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
For shutters of doors, windows & ventilators including providing and fixing
hinges/ pivots and making provision for fixing of fittings wherever required
including the cost of EPDM rubber / neoprene gasket required (Fittings shall be
142 21.1.2 paid for separately) - - - - -
Anodised aluminium (anodised transparent or dyed to required shade according
143 21.1.2.1 to IS: 1868, Minimum anodic coating of grade AC 15) Kg 120 598.60 623.208 - 74,785 - -
Providing and fixing glazing in aluminium door, window, ventilator shutters and
144 21.3 partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the - - - - -
architectural drawings and the directions of engineer-in-charge. (Cost of
aluminium snap beading shall be paid in basic item):
145 21.3.2 With float glass panes of 5.0 mm thickness(wt not less then 12.5 kg/sqm) sqm 21.00 1,505.25 1,567.131 - 32,910 - -
Providing and fixing double action hydraulic floor spring of approved Providing
and fixing double action hydraulic floor spring of approved brand and
manufacture conforming to IS : 6315, having brand logo embossed on the body
/ plate with double spring mechanism and door weight upto 125 kg, for doors,
including cost of cutting floors, embedding in floors as required and making
146 21.4 good the same matching to the existing floor finishing and cover plates with - - - - -
brass pivot and single piece M.S. sheet outer box with slide plate etc. complete
as per the direction of Engineer-in-charge
With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing machine moulded aluminium covering of approved pattern
& design, made out of machine cut aluminium sheet and machine holed for
receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors,
the fixing on plate in one row on one side of joint only shall be done with
stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including
providing aluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of
200mm centre to 2 mm thick & 15 mm dia , at a staggered pitch of 200mm
148 21.7 centre to centre including drilling holes in the receiving surface and providing - - - - -
expandable plastic sleeves in holes etc. complete as per direction of
Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to
149 21.7.1 required shade according to IS: 1868, Minimum anodic coating of grade AC 15) Kg 680.55 708.527 - - - -
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work
150 21.8 by providing weather silicon sealant over backer rod of approved quality as per - - - - -
architectural drawings and direction of Engineer-in-charge complete.
Upto 5mm depth and 5 mm width
Digitally signed by AMIT JAIN
IST Page 11 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Providing and laying water proofing treatment in sunken portion of WCs,
bathrooms etc. by applying cement slurry mixed with water proofing cement
comopund consisting of applying: a) First layer of slurry of cement @ 0.488
kg./Sqm mixed with water proofing cement comound @ 0.253 kg./Sqm. This
layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement
152 22.5 @ 0.242 kg./Sqm mixed with water proofing cement comopund @ 0.126 Sqm 144.00 617.05 642.417 - 92,508 - -
kg./Sqm. This layer will be allowed to air cure for 4 hours followed with water
curing for 48 hours. The rate includes preparation of surface, treatment and
sealing of all joints, corners, junctions of pipes and masonary with polymer
Providing and laying in situ five course water proofing treatment with APP
(Atactic Polypropylene) modified Polymeric memberane over roof consisting of
first coat of bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding
material @ 1.20 kg/sqm, which shall onsist of blown type bitumen of grade
85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified
Polymeric membrane .0 mm thick of 3.00 Kg/ sqm weight consisting of five
layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on
both sides with polymeric mix and the polymeric mix is protected on both side
with 20 micron HMHDPE film. 5th, the top most layer shall be finished with brick
tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine
153 14.87 sand) mixed with 2% integral water proofing compound by weight of cement Sqm 700.00 532.05 553.923 - 3,87,746 - -
over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished
neat (item of laying brick tiles shall be paid for separately).
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm)
with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial
emittance> 0.75 on waterproof and sloped surface of terrace, laid on 20 mm
154 12.55 thick cement sand mortar in the ratio of 1 :4 (1 cement : 4 coarse sand) and Sqm 700.00 1703.95 1,773.999 - 12,41,800 - -
grouting the joints with mix of white cement & marble powder in ratio of 1 :1,
including rubbing and polishing of the surface upto 3 cuts complete, including
providing skirting upto 150 mm height along the parapet walls in the same
155 26.0 NEW TECHNOLOGIES AND MATERIALS - - - - -
Digitally signed by AMIT JAIN
IST Page 12 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Providing and fixing false ceiling at all heights with integral densified calcium
silicate reinforced with fibre and natural filler false ceiling tiles of Size
595x595mm of approved texture, design and patterns as per CPWD
Specification 2019, to be laid in true horizontal level suspended on inter-locking
metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized
@ 120 grams per sqm including both sides)comprising of main-T runners of size
24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm
and secondary intermediate cross-T of size 24x32 mm of length 600mm to
formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised
mild steel items (galvanizing suspended from ceiling usinggalvanised mild steel
items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6
mm dia fully threaded hanger rod upto 1000 mm length and L-shape level
156 26.22 adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size - - - - -
25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into
12x50mm or even bigger size dash fastener if require, fixed with Glavanised
iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed
on periphey wall / partition with the help of plastic rawl plugs at 450mm center
to center and 40 mm long dry wall S.S screws. The workshall be carried out as
per specifications,
Providing and fixing false ceiling at all heights with integral densified calcium
silicate reinforced with fibre and natural filler false ceiling tiles of Size
595x595mm of approved texture, design and patterns as per CPWD
Specification 2019, to be laid in true horizontal level suspended on inter-locking
metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized
@ 120 grams per sqm including both sides)comprising of main-T runners of size
24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm
and secondary intermediate cross-T of size 24x32 mm of length 600mm to
formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised
mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash
157 26.22.1 fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L- sqm 2,207.00 2,297.730 - - - -
shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into
12x50mm or even bigger size dash fastener if require, fixed with Glavanised
iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed
on periphey wall / partition with the help of plastic rawl plugs at 450mm center
to center and 40 mm long dry wall S.S screws. The workshall be carried out as
per specifications,
158 17 SANITARY INSTALLATIONS - - - - -
Note:-1. All Sanitarty fixture shal be low flow as mentioned below , where flow/
flush rate of fixture shall be equivalent or lesser at 3 bar pressure( lpm/lpf) .
2. water closet flushing cistern (dual flush 3/6) urinals 2 lpm faucets (lavatory
160 ,pantry,health) 6 lpm. - - - - -
161 3.multiple sprinkler system native trees & vegetation shall be used. - - - - -
4.over flow rain water storage & reuse on site of at least 75% of total building
water demand of 2 days shall be provide .
Digitally signed by AMIT JAIN
IST Page 13 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
163 5. Desalting & grease trap system along with the proper flitation for rain water - - - - -
recharging shall be provided.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100
mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern,
including flush pipe, with manually controlled device (handle lever) conforming
to IS : 7231, with all fittings and fixtures complete, including cutting and making
164 17.1.1 good the walls and floors wherever required: White Vitreous china Orissa Each 8 6,767.40 7,045.608 - 56,365 - -
pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing white vitreous china wall hung type European W.C. pan with white
plastic seat and lid with C.P. brass hinges & rubber buffers, 3/6 liters dual flush
type white vitreous china low level flushing cistern fixed directly on W.C. pan
with fittings and brackets complete.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,
166 17.7 32 mm C.P. brass waste of standard pattern, including painting of fittings and - - - - -
brackets, cutting and making good the walls wherever require :
White Vitreous China Wash basin size 630x450 mm with a
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS :
168 17.10 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of - - - - -
fittings and brackets, cutting and making good the walls wherever required :
169 17.10.1 Kitchen sink with drain board - - - - -
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make
171 17.22A and as per the direction of Engineer-in-charge. Each 1.00 1,034.80 1,077.341 - 1,077 - -
Providing & fixing PVC waste pipe for sink or wash basin including PVC waste
172 17.28 fittings complete - - - - -
Providing and fixing 15mm C.P brass Sink Mixer for kitchen sink with swinging
spout complete. Including cutting and making good the walls wherever required
Shower set Providing and Fixing of C.P. Brass Shower set comprising of :One
No. CP brass Single Lever Concealed Diverter .One No. CP brass OH shower
head & Shower Arm One No. CP brass Bath Spout.Including cutting and
176 NS-4 making good the walls wherever required. Each 8 - - 6,285 - - 50,277
Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of
177 17.31 approved quality) complete with 6mm thick hard board ground fixed to wooden Each 16 1,607.95 1,674.053 - 26,785 - -
cleats with CP brass screws and washers complete.
178 17.34 Providing and fixing toilet paper holder : - - - - -
Digitally signed by AMIT JAIN
IST Page 14 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement of
approved quality and colour.
181 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective Each 12 708.95 738.095 - 8,857 - -
height of 88 mm, weighing not less than 190 gms
Providing and fixing health faucet with 1 m long flexible tube and wall hook
182 NS-5 including all fittings approved quality. Each 2.00 - - 1,412 - - 2,824
183 18.49 Providing & fixing CP brass bib cock of approved quality conforming IS 8931: - - - - -
Providing and fixing C.P. brass long body bib cock of approved quality
185 18.51 conforming to IS standards and weighing not less than 690 gms. - - - - -
15 mm nominal bore
Providing and fixing CP brass angle valve for basin mixer and geyser points of
approved quality confirming IS: 8931:
189 WATER SUPPLY - - - - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded
190 18.7 fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes - - - - -
jointing of pipes & fittings with one step CPVC solvent cement and testing of
joints complete as per direction of Engineer in Charge.
191 Internal work - Exposed on wall - - - - -
192 18.7.1 15 mm nominal outer dia Pipes Metre 12 286.80 298.590 - 3,583 - -
193 18.7.2 20 mm nominal outer dia Pipes Metre 12 335.00 348.772 - 4,185 - -
194 18.7.3 25 mm nominal outer dia Pipes Metre 12 401.55 418.058 - 5,017 - -
195 18.7.4 32 mm nominal outer dia Pipes Metre 12 518.75 540.076 - 6,481 - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded
fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing
of pipes & fittings with one step CPVC solvent cement and the cost of cutting
chases and making good the same including testing of joints complete as per
direction of Engineer in Charge.
197 Concealed work, including cutting chases and making good the walls etc. - - - - -
198 18.8.1 15 mm nominal outer dia Pipes Metre 12 497.80 518.265 - 6,219 - -
199 18.8.2 20 mm nominal outer dia Pipes Metre 12 537.60 559.701 - 6,716 - -
Providing and placing on terrace (at all floor levels) polythene water storage
200 18.48 tank of approved brand and manufacture with cover and suitable locking Litre 2000 11.00 11.452 - 22,904 - -
arrangement and making necessary holes for inlet , outlet and overflow pipes
but without fittings and the base support for tank.
Providing and fixing forged brass ball valve of brass body with hard chrome
201 NS-6 plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre - - - - -
handle with female BSP threads complete in all respects.
Digitally signed by AMIT JAIN
IST Page 15 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
207 Internal work - Exposed on Wall -
215 18.38 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats - - - - -
over a ready mixed priming coat, both of approved quality for new work :
221 18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the - - - - -
pipe and making long screws etc. complete (New work) :
229 INTERNAL DRAINAGE - - - - -
Providing and laying cement concrete in 1:2:4 ( 1cement : 2 Coarse sand : 4
graded stone aggregate 20 mm nominal size ) and curing complete, including
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm
231 12.44 diameter and weighing not less than 440 grams. Each 8.00 54.7 56.949 - 456 - -
Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC
pipes of min 6 Kg/ Sq cm rating with fitting for waste pipe from fixtures to floor
trap including reduces, enlarger, socket, couplers, bends, tees etc including
fixing at wall/ ceiling level supported by clamp & hangers etc. The work includes
232 NS-7 cutting holes in wall/ floors/ slabs and making good the same with cement
concrete 1:2:4 complete as required.
239 NS-8 Providing & fixing UPVC Floor trap of self cleansing design with CP Jali - - - - -
complete in all respects.
Digitally signed by AMIT JAIN
IST Page 16 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
240 NS-8-1 S-Trap type Floor Trap 110 x 110 mm (Long type-50 mm seal) Each 6.00 - - 777 - - 4,664
241 NS-8-2 P-Trap type Floor Trap 110 x 110 mm (Long type - 50 mm seal) Each 6.00 - - 452 - - 2,711
Providing and fixing cast brass floor clean out plug with suitable insert keys for 664
opening, male threaded joint with GI threaded socket drip seal to soil / waste
242 NS-9 pipe of CI pipe as required complete as per drawing approved sample and Each 4.00 - - - - 2,658
direction of engineer in charge.-100 mm dia
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff
243 19.1 mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) - - - - -
including testing of joints etc. complete :
245 EXTERNAL SEWEGE SYSTEM - - - - -
Earth work in excavation by mechanical means (Hydraulic excavator) / manual
means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm
on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m,
246 2.8 including getting out the excavated soil and disposal of surplus excavated soil as - - - - -
directed, within a lead of 50 m.
Excavating trenches of required width for pipes, cables, etc including excavation
for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m,
including getting out the excavated soil, and then returning the soil as required,
in layers not exceeding 20 cm in depth, including consolidating each deposited
248 2.10 layer by ramming, watering, etc. and disposing of surplus excavated soil as - -
directed, within a lead of 50 m :
249 2.10.1 All kinds of soil. - - - - -
250 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia Metre 6 352.15 366.627 - 2,200 - -
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I.
grating brick masonry chamber with water tight C.I. cover with frame of 300
x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame
to be not less than 2.70 kg as per standard design:
253 19.4.3.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 4 2802.15 2,917.346 - 11,669 - -
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse
sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-
III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8
mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm
254 19.7 nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement - - - - -
: 3 coarse sand) finished with floating coat of neat cement and making channels
in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size) finished with a floating coat of neat cement complete as
per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light
255 19.7.1 duty) 455x610 mm internal dimensions, total weight of cover and frame to be - - - - -
not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
256 19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 4 12,770.55 13,295.547 - 53,182 - -
257 19.8 Extra for depth for manholes : - - - - -
259 19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 4 8825.4 9,188.212 - 36,753 - -
Digitally signed by AMIT JAIN
IST Page 17 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786
having minimum cross section as 23 mmx25mm and over all minimum length
263 mm and width as 165mm with minimum 112 mm space between protruded
legs having 2 mm tread on top surface by ribbing or chequering besides
necessary and adequate anchoring projections on tail length on 138 mm as per
260 19.16 standard drawing and suitable to with stand the bend test and chemical Each 1 553.70 576.463 - 576 - -
resistance test as per specifications and having manufacture's permanent
identification mark to be visible even after fixing, including fixing in manholes
with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 20 mm nominal size) complete as per design.
261 19.10 Extra depth for circular type manhole 0.91m internal dia (at bottom) with - - - - -
beyond 0.91m to 1.67m.
262 19.10.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 2 7,592 7,903.899 - 15,808 - -
Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes
263 NS-10 confirming to IS: 16098 including all fittings wherever required e.g., tees, - - - - -
bends of any degree, couplings, adapters, plugs, unions etc. and jointing as
manufacturer recommondation etc. including testing of joints etc. complete.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10
268 19.3 graded stone aggregate 40mm nominal size) up to haunches of S.W/RCC pipes - - - - -
including bed concrete as per standard design.
Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786
having minimum cross section as 23 mmx25mm and over all minimum length
263 mm and width as 165mm with minimum 112 mm space between protruded
legs having 2 mm tread on top surface by ribbing or chequering besides
necessary and adequate anchoring projections on tail length on 138 mm as per
standard drawing and suitable to with stand the bend test and chemical
resistance test as per specifications and having manufacture's permanent
271 19.16 identification mark to be visible even after fixing, including fixing in manholes Each 8 553.7 576.463 - 4,612 - -
with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 20 mm nominal size) complete as per design.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with
272 19.6 collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 - - - - -
cement : 2 fine sand) including testing of joints etc. complete :
276 19.8 Extra for depth for manholes : - - - - -
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) with
280 19.10.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 2 7591.8 7,903.899 - 15,808 - -
Digitally signed by AMIT JAIN
IST Page 18 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond
282 19.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 2 9861.45 10,266.854 - 20,534 - -
Constructing bricks masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) in
284 19.27.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 8 5957.9 6,202.829 - 49,623 - -
285 19.31.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 10 6117 6,368.470 - 63,685 - -
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLS PVC insulated copper conductor single core cable in surface /
recessed medium class PVC conduit, with modular switch, modular plate,
287 1.10 suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated - - - - -
copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed medium class PVC conduit, 2
way modular switch, modular plate, suitable GI box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as
Wiring for light/power plug with 2x4 Sq.mm FRLS PVC insulated, copper
conductor, single core cable in surface/recessed PVC conduit alongwith 1 No. 4
290 1.12 Sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing Metre 200.00 - 334 359.6519 - 71,930 -
Wiring for light/power plug with 4x4 Sq.mm FRLS PVC insulated, copper
conductor, single core cable in surface/recessed PVC conduit alongwith 2 Nos. 4
291 1.13 Sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing Metre 200.00 - 537 578.2428 - 1,15,649 -
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
292 1.14 FRLS PVC insulated copper conductor, single core cable in surface/ recessed - - - - -
medium class PVC conduit as required
Supplying and fixing of following sizes of medium class PVC conduit along with
298 1.21 accessories in surface/recess including cutting the wall and making good the - - - - -
same in case of recessed conduit as required.
Supplying and fixing stepped type electronic fan regulator on the existing
301 1.25 modular plate switch box including connections but excluding modular plate etc. Each 40.00 - 369 397.3400 - 15,894 -
Supplying and fixing modular blanking plate on the existing modular plate &
302 1.26 switch box excluding modular plate as required. Each 60.00 - 40 43.0721 - 2,584 -
303 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & - - - - -
cover plate for modular switches in recess etc as required.
Digitally signed by AMIT JAIN
IST Page 19 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Supplying and fixing suitable size GI box with modular plate and cover in front
on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps
modular socket outlet and 15/16 amps modular switch, connection etc. as
Installation, testing and commissioning of pre-wired, fluorescent fitting /
compact fluorescent fitting of all types, complete with all accessories and tube
etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC
insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down
rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated,
copper conductor, single core cable, including providing and fixing phenolic
laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the
damage, connection, testing, commissioning etc. as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground
312 18.12 complete with G.I. fittings including trenching (75 cm deep)and re-filling etc. as - - - - -
Supplying and fixing following way, single pole and neutral, sheet steel ,MCB
315 2.3 distribution board, 240 volts, on surface/ recess, complete with tinned copper - - - - -
busbar, neutral bus bar, earth bar, din bar, interconnections powder painted
including earthing etc. as required. (But with out MCB/RCCB/ Isolator).
Supplying and fixing following way, horizontal type three pole and neutral, sheet
steel ,MCB distribution board, 415 volts, on surface/ recess, complete with
317 2.4 tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections - -
powder painted including earthing etc. as required. (But with out MCB/RCCB/
supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C Curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
319 2.10 DB complete with connectoin testing and commissioning etc.as required. - -
Digitally signed by AMIT JAIN
IST Page 20 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
supplying and fixing following rating,double pole,240 V,isolator in the existing
321 2.12 MCB DB complete with connectoin testing and commissioning etc.as required. - -
323 2.13 supplying and fixing following rating,four pole,415 V,isolator in the existing MCB - -
DB complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,double pole,240 V,residual current circuit
325 2.14 breaker (RCCB),having a sensitivity currrent 30 mA in the eiting MCB DB - -
completed with connection ,teting commisoining etc.as required.
327 EARTHING - -
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories,
and providing masonry enclosure with cover plate having locking arrangement
328 5.2 and watering pipe etc. with charcoal/ coke and salt as required. Each 4.00 - 6855 7,381.4791 - 29,526 -
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as
strip earth electrode, including connection/ terminating with G.I. nut, bolt,
spring, washer etc. as required. (Jointing shall be done by overlapping and with
329 5.9 2 sets of G.I. nut bolt & spring washer spaced at 50mm) Metre 30.00 - 144 155.0595 - 4,652 -
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop
earthing along with existing surface/ recessed conduit/ submain wiring/ cable as
331 FITTING & FIXTURES - -
Supply, Installation, Testing & Commissioning of recessed type down lighter
332 NS-11 complete with lamps & accessories 18 W Philips Model No:DN296B LED 20S- Each 20.00 - - 1,470.79 - - 29,416
6500 PSE WH S2/ Havells Model: INTEGRANEODLR18WLED865S or equivalent
Supply, Installation, Testing & Commissioning of recess type 2x2, 36watt LED
333 NS-12 Light Fixtures complete with lamps & accessories.Philips Model No:RC380B LED Each 15.00 - - 7,295.13 - - 1,09,427
36S/ Havells Model: VENUSNEO2X2PLR36WLED865G2 or equivalent
Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star
rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of
insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit,
safety rope, copper winding, Power Factornot less than 0.9, Service Value
334 19.1 (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM Each 20.00 - 2730 2,939.6700 - 58,793 -
(tolerance as per IS : 374-2019),THD less than 10%, remote or electronic
regulator unit for speed control and all remaining accessories including safety
pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation
resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC
Supplying of approved make Exaust Fan of the following size and its all
335 NS-13 accessories suitable for operation on 230V single phase, 50 Hz, AC supply Each 10.00 - - 2,432.76 - - 24,328
complete as required.-250 mm
336 SUB HEAD-XII :-LIGHTING CONDUCTOR - -
Providing & Fixing of lightning conductor finial, made of 25 mm dia 300 mm
long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I.
337 6.2 base plate including holes etc. complete as required. No. 1 - 518 557.7835 - 558 -
Fixing of lightning conductor finial, single prong at top, with base plate including
338 6.3 holes etc. complete as required. No. 1 - 360 387.6488 - 388 -
Digitally signed by AMIT JAIN
IST Page 21 of 103
DSR-2022 E/M Amount (DSR- Amount (DSR
Item No Rate-DSR.2023 DSR 2022 E/M Rate (incl. CF 2023) Civil 2022+GST
S. No. Description of Item Unit Qty (incl. CF 0.973 Rate -NS NS AMOUNT
(DSR-2023) Rate 0.973+CI with correction 6.33%) E/M with
4.08% ) factor correction factor
Providing and fixing G.I. tape 20 mm x 3 mm thick on parapet or on surface of
339 6.7 wall for lightning conductor complete as required.( For horizontal run) Metre 4 - 126 135.6771 - 543 -
Providing and fixing G.I. tape 20 mm x 3 mm thick on parapet or on surface of
340 6.8 wall for lightning conductor complete as required.( For vertical run) Metre 4 - 197 212.1300 - 849 -
Providing and fixing glazing in aluminium door, window, ventilator shutters and
341 NS-14 partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the Sqm 10 - - 1637.6 16376.0
architectural drawings and the directions of engineer-in-charge. (No extra Cost
)-Laminated Clear Toughned glass -6 mm
342 NS-15 Providing and fixing Granite quadrant of 250 mm dia bathroom corner self with Each 20 - - 415.3 8305.7
all respect complete
Supply, Installation, Testing & Commissioning of flood light 80watt with all
343 NS-16 respect complete. Each 1 - - 7572.4 7572.4
344 NS-17 Providing and fixing Aluminium Ventilator Louvers with 5 mm thick glass with all Sqm 4 - - 4952.5 19810.1
respect complete.
Digitally signed by AMIT JAIN
IST Page 22 of 103
BOQ- Type-III-14-G+3
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
1 2.0 EARTH WORK -
2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan)
including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth
to be levelled and neatly dressed.
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited
4 layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. cum 561.69 196.00 204.058 - - 1,14,617.09 - -
2.27 Supplying and filling in plinth with sand under floors including watering, ramming
5 consolidating and dressing complete. Cum 30.00 2123.75 2,211.057 - - 66,331.72 - -
6 2.28 Surface dressing of the ground including removing vegetation - - - - - -
7 2.28.1 All kinds of soil Sqm - - - - - -
8 2.34 Supplying chemical emulsion in sealed containers including delivery as specified. - - - - - -
9 2.34.1 Chlorpyriphos/Lindane Emulsifiable concentrate of 20%. Ltr. 20.00 234.75 244.401 - - 4,888.01 - -
2.35 Diluting and injecting chemical emulsion for Post - CONSTRUCTIONAL anti-termite
10 treatment (excluding the cost of chemical emulsion) - - - - - -
Along external wall where the apron is not provided using chemical emulsion @ 7.5
11 2.35.1 litres / sqm of the vertical surface of the substructure to a depth of 300mm including - - - -
excavation channel along the wall & rodding etc. complete:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole,
13 300 mm apart including drilling 12 mm dia holes and plugging with cement mortar 1:2 - - - - - -
(1 cement :2 coarse sand ) to match the existing floor.
14 2.35.3.1 With Chlorpyriphos /Lindane E C. 20% with 1% concentration. Sqm 400.00 310.05 322.796 - - 1,29,118.46 - -
15 4.0 CONCRETE WORK - - - - - -
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of
cantering and shuttering - All work up to plinth level
17 4.1.8 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) cum 70.91 6812.00 7,092.041 - - 5,02,889.56 - -
4.1.10 1:5:10 (1 cement : 5 coarse sand(zone -III) derived from natural soueces : 10 graded
stone aggregate 40 mm nominal size Derived from natural soueces
4.10 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1
19 cement : 2 coarse sand(zone -III) derived from natural soueces : 4 graded stone Sqm 64.40 410.85 427.740 - - 27,546.46 - -
aggregate 12.5 mm nominal size derived from natural soueces.
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3
manufactured sand (zone-III) derived from natural sources : 6 graded stone aggregate
20 mm nominal size derived from natural sources over 75mm thick bed of dry brick
20 ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, Sqm 67.50 749.30 780.104 - - 52,657.00 - -
including necessary excavatin, levelling & dressing & finishing the top smooth.
22 5.9 Centring and shuttering including strutting, propping etc. and removal of form for: - - - - - -
23 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. sqm 256.08 392.15 408.271 - - 1,04,550.11 - -
24 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 1350.00 927.25 965.369 - - 13,03,248.48 - -
25 5.9.5 Lintels, beams, plinth beams, girders, bressummers and cantilevers. Sqm 324.40 736.40 766.673 - - 2,48,708.85 - -
26 5.9.6 Columns, Pillars, Piers, Abutments, posts and Struts Sqm 752.40 961.30 1,000.819 - - 7,53,016.25 - -
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
28 5.22.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 18866.62 107.85 112.284 - - 21,18,415 - -
5.22 A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
30 5.22A.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 27600.18 107.85 112.284 - - 30,99,051 - -
5.33 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade
for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to
31 site of laying , excluding the cost of cantering, shuttering finishing and reinforcement, - - - - - -
including cost of admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately).
32 All works upto plinth level - - - - - -
Digitally signed by
ISTPage 23 of 103
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
33 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 168.45 9504.75 9,895.490 - - 16,66,915 - -
34 All works above plinth level upto floor V level - - - - - -
35 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 246.43 9860.40 10,265.761 - - 25,29,794 - -
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5
6.1 in foundation and plinth
38 6.1.2 Cement mortar 1:6 (1 cement: 6 coarse sand) Cum 27.60 7,132.25 7,425.457 - 2,04,943 -
6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third
course of half brick masonry.
6.32 Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in
superstructure above plinth level up to floor five level in :
6.45 Half brick masonry with non modular fly ash bricks of class designation 10, conforming
to IS: 12894, in superstructure above plinth up to floor V level.
44 8.0 CLADDING WORK - - - - - -
Providing and fixing 18mm thick gang saw cut mirror polished remoulded and
repolished) machine cut for kitchen platforms, vanity counters, window sills , facias and
similar locations of required size of approved shade, colour and texture laid over 20mm
45 8.2 thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white - - - - - -
cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc. complete at all levels.
46 8.2.3 Granite stone slab of all colourand texture expect black,Cherry/ Ruby Red - - - - - -
Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including
48 8.3 machine polishing to edge to give high gloss finish etc. complete as per design - - - - - -
approved by Engineer-in-Charge.
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia
50 8.4 and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning metre 14.00 568.55 591.923 - - 8,286.92 - -
Extra for providing opening of required size & shape for wash basins / kitchen sink in
51 8.5 kitchen platform, vanity counters and similar location in marble / Granite / stone work Each 14.00 978.70 1,018.934 - - 14,265.08 - -
including necessary holes for pillar taps etc. Including rubbing and polishing necessary
Providing wood work in frames of doors, windows, clerestory windows and other
53 9.1 frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners - - - -
of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing 19 mm thick both side balancing laminationfactory pressed BWP
grade marine ply as per IS : 710 of approved brand
boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws
55 9.169 etc. complete as per direction of Engineer-incharge Sqm 172.80 2593.15 2,699.754 - - 4,66,517.56 - -
9.21 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)
56 non-decorative type, core of block board construction with frame of 1st class hard wood - - - - - -
and well matched commercial 3 ply veneering with vertical grains or cross bands and
face veneers on both faces of shutters :
57 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 17.64 2392.65 2,491.012 - - 43,941.45 - -
9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on
all edges of flush door shutters (over all area of door shutter to be measured).
9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to be
9.76 Providing & fixing bright finished brass 100mm mortice latch and lock with 6 levers and
60 a pair of lever handles with necessary screws etc. complete (Best make of approved Each 48 854.65 889.785 - - 42,709.66 - -
9.96 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating
61 not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or - - - - - -
shade with nuts and screws etc. complete:
9.97 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less
63 than grade AC 10 as per IS : 1868 ) transparent or dyed toreqired colour or shade with - - - - - -
necessary screws etc.
9.100 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less
65 than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade - - - - - -
with necessary screws etc. complete :
9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic
67 coating not less than grade AC 10 as per IS :1868) transparent or dyed to required - - - - - -
colour or shade with necessary screws etc. complete:
Digitally signed by
ISTPage 24 of 103
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
9.79 Providing & fixing special quality bright finished brass Cupboard or ward robe locks with
69 four levers including necessary screws etc. complete (best make of approved quality). - - - - - -
9.91 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with
nuts complete. 151.05
9.114 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe
shutters, including fixing with necessary screws etc. complete.
73 9.114.2 Double strip (horizontal type) Each 96 39.7 41.332 - - 3,967.88 - -
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in
74 9.127 gloss / matt / suede finish with high density protective surface layer and reverse side of - - - -
adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of
approved quality.
9.147A Providing and fixing factory made uPVC glazed/wire mesh windows/comprising of lead
free uPVC multi-chambered frame, sash and mullion/coupler (where ever required)
extruded profiles having minimum wall thickness of 1.7 mm for series R1 and R2
profiles and 2.1 mm for series R3 and R4 profiles confirming to EN:12608 in any shape,
colure and design duly reinforced with galvanized mild steel section made of required
shape & size as per CPWD Speifications ,upvc extructed glazing beads ,interlocks and
inline sash adaptor (where ever required ) of appropriate dimension ,EPDM gasket,
stainless steel SS 304 grade fastners of minimum 8 mm dia with countersunk head
,comprising of matching polymade PA6 grade sleeve for fixing frame to finishing wall as
76 per IS 1367 : Part 1 to 14 coated) casement handles, G.I fasteners 100 x 8 mm size - - - -
for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless
steel screws etc. Profile of frame & sash mullion ( if required ) shall be mitred cut and
fusion welded /mechanically jointed duly sealed at all corners, including drilling of holes
for fixing hardware's and drainage of water etc. After fixing frame the gap between
frame and adjacent finished wall shall be filled with weather proof silicon sealant over
backer rod of required size and of approved quality, all complete as per approved
drawing comprising to CPWD Specification & direction of Engineer-in-Charge. section of
steel reinforcement and cross section of UPVC Profile to be as per design approved by
Engineer-in-Charge.
Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without
77 high performance coatings as per design requirements and conforming to IS: 3548 & - - - -
IS: 16231 shall be paid separately
Note:- Structural design proof checked from a Government Engineering Institute, to be
provided by the manufacturer for
79 (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 - - - -
80 (ii) Sites with structure height more than 20m for all wind speeds - - - -
9.147.A1.3 Using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm &
81 above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every Sqm 189.00 9628.6 10,024.432 - 18,94,617.60 -
panel along with multi-point locking system (Height above 1.8m)
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
flats, square or round bars etc. including priming coat withapproved steel primer all
83 9.48.1 Fixed to steel window by welding kg 108.00 219.1 228.107 - - 24,635.58 - -
26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC
polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers
(wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index
of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and
screwed with full body threaded star headed SS screws having minimum frame density
of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum
compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to
84 spread of flame of Class A category with property of being termite/borer proof, - - - - -
water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS
dash fasteners of required dia and length complete as per direction of Engineer-In-
Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).
Note: For WPC solid door/window frames, minus 5 mm tolerance in profile dimensions
on plus side shall be acceptable but no extra payment on this account shall be made
Digitally signed by
ISTPage 25 of 103
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
board one side white color and other side of board laminited with pvc foil of minium 14
micron thickness of approved design pasted with hot melt adhesive for cup boards,work
station and bathroom /kitchen cabinet etc.of required sizes comprising of virgin polymer
of K (value 58-60 (suspension grade ), calcium carbonate and natural fibers (wood
powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12
for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of
87 26.89 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of - - - - -
elasticity 850 N/mm2 and resistance to spread of flame of Class A category with
property of being termite/borer proof, water/moisture proof and fire retardant and
fixing with stainless steel piano hinges /soft close clip on concealed hinges of required
size with necessary full body threaded star headed counter sunk S.S screws, all as per
direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft clip on
concealed hinges and necessary S.S screws shall be paid separately).
89 NS-18 Providing and fixing Magic eye with all respect complete. Each 12.00 - - 164.45 - - 1,973.42
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured
from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock
jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or
91 10.14 base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical - - - - - -
means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike
plate and shock absorbers as specified and applying a coat of approved steel primer
after pre-treatment of the surface as directed by Engineer-in-charge:
92 10.14.3.1 Fixing with adjustable lugs with split end tail to each jamb (Profile E) metre 2 640.20 666.519 - - 1,333.04 - -
93 10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb (Profile B) metre 2 583.30 607.279 - - 1,214.56 - -
94 10.14.2.1 Fixing with adjustable lugs with split end tail to each jamb (Profile C) metre 2 611.75 636.899 - - 1,273.80 - -
10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan
clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with
its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/
M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners.
Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels,
plates etc., including welding, grinding, buffing, polishing and making curvature
(wherever required) and fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories & stainless steel dash
fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side
of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless steel members shall be considered excluding
fixing accessories such as nuts, bolts, fasteners
10.29 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with
M.S. Flat 15x3 mm and nuts & bolts complete.
10.29.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both
99 11.0 FLOORING WORK - - - - - -
11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by
the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622,
of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick
cement mortar 1 :4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3
kg/sqm including grouting the joints with white cement and matching pigments etc. The
100 tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be - - - - - -
done with the notch trowel, plier, wedge, clips of required thickness, leveling system
and rubber mallet for placing the tiles gently and easily.
101 11.41A.1 Double charge vitrified tile polished finish of size - - - - - -
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
103 11.38 make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 sqm 115.20 1315.3 1,369.372 - 1,57,751.65 -
mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey
cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and
matching pigments etc., complete.
Digitally signed by
ISTPage 26 of 103
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
Providing and laying Ceramic glazed Wall tiles of size 600x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
104 NS-56 make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 sqm 970.56 - - 1453.49 - 14,10,698.75
mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey
cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and
matching pigments etc., complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in
linear as well as curvilinear portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement
mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing
105 11.56 with white cement slurry admixed with pigment of matching shade including rubbing , - - - - - -
curing and polishing etc. all complete as specified and as directed by the Engineer-in-
106 11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red sqm 336.19 3071.05 3,197.301 - - 10,74,889.07 - -
NS-1 Providing and fixing 1 mm galvalume roof sheet AZ-150 ,660 MPA including ridge,
108 flashing over lapping etc complete plan area should be measured nothing extra shall sqm 345.00 - - 598.01 - - 2,06,312.45
be paid for lap, profile. ( valley creast etc)
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm Painting top
of roofs with bitumen of approved quality @ 17kg per 10 sqm
109 12.15 impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the sqm - - - - -
slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil
110 12.15.1 With residual type petroleum bitumen of grade VG -10 sqm 130 166.2 173.032 - 22,494.22 - -
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses
etc., including cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer, including welding and bolted with special shaped washers etc.
12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm
diameter and weighing not less than 440 grams.
114 13.0 FINISHING WORK - - - - -
115 13.4 12 mm cement plaster of mix : - - - - -
13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1
117 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 Sqm 860 518.55 539.868 - 4,64,286.13 - -
cement : 6 fine sand).
118 13.16 6 mm cement plaster to ceiling of mix : - - - - -
13.41 Distempering with1st quality acrylic distemper (ready mixed) having VOC content less
120 then 50 gram/litre of approved manufacture and of required shade and colour complete - - - - -
to achieve even shade and colour.
13.41.1 New work (two or more coats) over and including water tinnable priming coat with
cement primer having VOC content less then 50 gram/litre .
13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50
gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt
122 resistance exterior paint of required shade (Company Depot Tinted) with silicon - - - - -
13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming
123 coat of exterior primer applied @ 0.90 litre/10 sqm. Sqm 860 181.25 188.701 - 1,62,283.02 - -
13.62 Painting with synthetic enamel paint of approved brand and manufacture of required
colour to give an even shade :
13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary
paint of approved brand and manufacture
13.80 Providing and applying white cement based putty of average thickness 1 mm, of
126 approved brand and manufacturer, over the plastered wall surface to prepare the sqm 4146.68 156.05 162.465 - 6,73,691.65 - -
surface even and smooth complete.
13.83 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile
127 Organic Compound ) content less than 50 grams/ litre of approved brand and - - - - -
manufacture, including applying additional coats wherever required to achieve even
shade and colour.
129 21.0 ALUMINIUM WORK - - - - -
Digitally signed by
ISTPage 27 of 103
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections
of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of
required dia and size, including necessary filling up the gaps at junctions, i.e. at top,
bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections
shall be smooth, rust free, straight, mitred and jointed mechanically wherever required
130 including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / - - - - -
stainless steel screws, all complete as per architectural drawings and the directions of
Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
131 21.1.1 For fixed portion - - - - -
21.1.1.1 Anodised aluminium (anodised transparent or
132 dyed to required shade according to IS: 1868, Kg 10.00 495.05 515.402 - 5,154.02 - -
Minimum anodic coating of grade AC 15)
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/
133 pivots and making provision for fixing of fittings wherever required including the cost of - - - - -
EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
21.1.2.1 Anodised aluminium (anodised transparent or
134 dyed to required shade according to IS: 1868, Kg 9.00 598.60 623.208 - 5,608.88 - -
Minimum anodic coating of grade AC 15)
21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and
135 partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the - - - - -
architectural drawings and the directions of engineer-in-charge. (Cost of aluminium
snap beading shall be paid in basic item):
136 21.3.2 With float glass panes of 5.0 mm thickness(wt not less then 12.5 kg/sqm) sqm 40.00 1505.25 1,567.131 - 62,685.23 - -
21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by
providing weather silicon sealant over backer rod of approved quality as per
137 architectural drawings and direction of Engineer-in-charge complete. - - - - -
138 21.8.1 Upto 5mm depth and 5 mm width Metre 2 96.75 100.727 - 201.45 - -
139 WATER PROOFING - - - - -
Providing and laying water proofing treatment in sunken portion of WCs, bathrooms etc.
by applying cement slurry mixed with water proofing cement comopund consisting of
applying: a) First layer of slurry of cement @ 0.488 kg./Sqm mixed with water proofing
cement comound @ 0.253 kg./Sqm. This layer will be allowed to air cure for 4 hours. b)
Second layer of slurry of cement @ 0.242 kg./Sqm mixed with water proofing cement
comopund @ 0.126 kg./Sqm. This layer will be allowed to air cure for 4 hours followed
with water curing for 48 hours. The rate includes preparation of surface, treatment and
sealing of all joints, corners, junctions of pipes and masonary with polymer mixed
Providing and laying in situ five course water proofing treatment with APP (Atactic
Polypropylene) modified Polymeric memberane over roof consisting of first coat of
bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20
kg/sqm, which shall onsist of blown type bitumen of grade 85/25 conforming to IS :
702, 3rd layer of roofing membrane APP modified Polymeric membrane .0 mm thick of
141 14.87 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 Sqm 20 532.05 553.923 - 11,078.45 - -
micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric
mix is protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall
be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1
cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of
cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished
neat (item of laying brick tiles shall be paid for separately).
12.55 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with
SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance> 0.75 on
waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in
142 the ratio of 1 :4 (1 cement : 4 coarse sand) and grouting the joints with mix of white Sqm 20 1703.95 1,773.999 - 35,479.99 - -
cement & marble powder in ratio of 1 :1, including rubbing and polishing of the surface
upto 3 cuts complete, including providing skirting upto 150 mm height along the
parapet walls in the same manner
143 26.0 NEW TECHNOLOGIES AND MATERIALS - - - - -
Digitally signed by
ISTPage 28 of 103
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
26.22 Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595mm of approved texture, design and patterns
as per CPWD Specification 2019, to be laid in true horizontal level
suspended on inter-locking metal T-Grid of hot dipped galvanised
iron section of 0.33mmthick (galvanized @ 120 grams per sqm
including both sides)comprising of main-T runners of size 24x38
mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T of size 24x32 mm
of length 600mm to formgrid module of size 600 x 600 mm,
144 suspended from ceiling usinggalvanised mild steel items (galvanizing - - - - -
@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level
adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require,
fixed with Glavanised iron perimeter wall angle or size 24x24x0.40
mm of length 3000 mm to be fixed on periphey wall / partition with
the help of plastic rawl plugs at 450mm center to center and 40 mm
long dry wall S.S screws. The workshall be carried out as per
specifications,
26.22.1 Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595mm of approved texture, design and patterns
as per CPWD Specification 2019, to be laid in true horizontal level
suspended on inter-locking metal T-Grid of hot dipped galvanised
iron section of 0.33mmthick (galvanized @ 120 grams per sqm
including both sides)comprising of main-T runners of size 24x38
mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T of size 24x32 mm
of length 600mm to formgrid module of size 600 x 600 mm,
145 suspended from ceiling usinggalvanised mild steel items (galvanizing sqm 57.60 2207 2,297.730 - 1,32,349.23 - -
@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level
adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require,
fixed with Glavanised iron perimeter wall angle or size 24x24x0.40
mm of length 3000 mm to be fixed on periphey wall / partition with
the help of plastic rawl plugs at 450mm center to center and 40 mm
long dry wall S.S screws. The workshall be carried out as per
specifications,- With 15 mm thick Tegular edged light weight calcium sliciate false ceiling
146 17.0 SANITARY INSTALLATIONS - - - - -
Note:-1. All Sanitarty fixture shal be low flow as mentioned below , where flow/ flush
rate of fixture shall be equivalent or lesser at 3 bar pressure( lpm/lpf) .
2. water closet flushing cistern (dual flush 3/6) urinals 2 lpm faucets (lavatory
,pantry,health) 6 lpm.
149 3.multiple sprinkler system native trees & vegetation shall be used. - - - - -
4.over flow rain water storage & reuse on site of at least 75% of total building water
demand of 2 days shall be provide .
5. Desalting & grease trap system along with the proper flitation for rain water
recharging shall be provided.
17.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm
sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush
pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all
fittings and fixtures complete, including cutting and making good the walls and floors
152 wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm Each 12 6,767.40 7,045.608 - 84,547 - -
with integral type foot rests
NS-2 Providing white vitreous china wall hung type European W.C. pan with white plastic seat
and lid with C.P. brass hinges & rubber buffers, 3/6 liters dual flush type white vitreous
153 china low level flushing cistern fixed directly on W.C. pan with fittings and brackets Each 12 - - 17,916.68 - - 2,15,000.16
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm
C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting
154 and making good the walls wherever require : - - - - -
17.7.2 White Vitreous China Wash basin size 630x450 mm with a
single 15 mm C.P. brass pillar tap
17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with
156 C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, - - - - -
cutting and making good the walls wherever required :
157 17.10.1 Kitchen sink with drain board - - - - -
Digitally signed by
ISTPage 29 of 103
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as
per the direction of Engineer-in-charge.
17.28 Providing & fixing PVC waste pipe for sink or wash basin including PVC waste fittings
Providing and fixing 15mm C.P brass Sink Mixer for kitchen sink with swinging spout
complete. Including cutting and making good the walls wherever required .
164 Providing and Fixing of C.P. Brass Shower set comprising of : - - - - -
165 One No. CP brass Single Lever Concealed Diverter . - - - - -
166 One No. CP brass OH shower head & Shower Arm . - - - - -
167 One No. CP brass Bath Spout. - - - - -
168 Including cutting and making good the walls wherever required. - - - - -
169 NS-4 Shower set as described above. Set 4 - - 6,284.61 - - 25,138.45
17.31 Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved
170 quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP Each 24 1607.95 1,674.053 - 40,177.27 - -
brass screws and washers complete.
171 17.34 Providing and fixing toilet paper holder : - - - - -
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to
173 wooden cleats with CP brass screws with concealed fittings arrangement of approved - - - - -
quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height
of 88 mm, weighing not less than 190 gms
Providing and fixing health faucet with 1 m long flexible tube and wall hook including all
fittings approved quality.
176 18.49 Providing & fixing CP brass bib cock of approved quality conforming IS 8931: - - - - -
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS
standards and weighing not less than 690 gms.
Providing and fixing CP brass angle valve for basin mixer and geyser points of approved
quality confirming IS: 8931:
182 WATER SUPPLY - - - - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
183 18.7 including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & - - - - -
fittings with one step CPVC solvent cement and testing of joints complete as per
direction of Engineer in Charge.
184 Internal work - Exposed on wall - - - - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in
190 Concealed work, including cutting chases and making good the walls etc. - - - - -
194 18.8.4 32 mm nominal outer dia Pipes Metre 90 739.30 769.693 - 69,272.34 - -
Providing and placing on terrace (at all floor levels) polythene water storage tank of
195 18.48 approved brand and manufacture with cover and suitable locking arrangement and Litre 12000 11.00 11.452 - 1,37,426.52 - -
making necessary holes for inlet , outlet and overflow pipes but without fittings and the
base support for tank.
196 INTERNAL DRAINAGE - - - - -
12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm
diameter and weighing not less than 440 grams.
Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of
min 6 Kg/ Sq cm rating with fitting for waste pipe from fixtures to floor trap including
reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level
198 NS-7 supported by clamp & hangers etc. The work includes cutting holes in wall/ floors/ slabs - - - - -
and making good the same with cement concrete 1:2:4 complete as required.
Digitally signed by
ISTPage 30 of 103
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all
206 NS-8-1 S-Trap type Floor Trap 110 x 110 mm (Long type-50 mm seal) Each 24.00 - - 777.41 - - 18,657.82
207 NS-8-2 P-Trap type Floor Trap 110 x 110 mm (Long type - 50 mm seal) Each 24.00 - - 451.83 - - 10,843.86
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of
208 19.1 cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of - - - - -
joints etc. complete :
210 EXTERNAL SEWEGE SYSTEM - - - - -
211 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not excee - - - - -
2.10 Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting
out the excavated soil, and then returning the soil as required, in layers not exceeding
20 cm in depth, including consolidating each deposited layer by ramming, watering, etc.
213 and disposing of surplus excavated soil as directed, within a lead of 50 m : - - - - -
214 2.10.1 All kinds of soil. - - - - -
215 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia Metre 120 352.15 366.627 - 43,995.23 - -
19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating
brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size
(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design:
218 19.4.3.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 16 2802.15 2,917.346 - 46,677.54 - -
19.7 Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse
sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone
aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick
219 with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat - - - -
cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4
graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat
cement complete as per standard design
19.7.1 Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x
220 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg - - - -
(weight of cover 23 kg and weight of frame 15 kg)
221 19.7.1.1 With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5 each 10.00 12,770.55 13,295.547 - 1,32,955.47 -
222 19.8 Extra for depth for manholes : - - - - -
224 19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 10 8825.40 9,188.212 - 91,882.12 - -
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable in surface / recessed medium class
226 1.10 PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point - - - - -
with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor
228 1.11 single core cable in surface / recessed medium class PVC conduit, 2 way modular Point 60.00 - 1562 1,681.97 - 1,00,917.90 -
switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC
insulated copper conductor single core cable etc as required.
Wiring for light/power plug with 2x4 Sq.mm FRLS PVC insulated, copper conductor,
229 1.12 single core cable in surface/recessed PVC conduit alongwith 1 No. 4 Sq.mm FRLS PVC Metre 80.00 - 334 359.65 - 28,772.16 -
insulated copper conductor single core cable for loop earthing as required.
Wiring for light/power plug with 4x4 Sq.mm FRLS PVC insulated, copper conductor,
230 1.13 single core cable in surface/recessed PVC conduit alongwith 2 Nos. 4 Sq.mm FRLS PVC Metre 60.00 - 537 578.24 - 34,694.57 -
insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS
231 1.14 PVC insulated copper conductor, single core cable in surface/ recessed medium class - - - - -
PVC conduit as required
Digitally signed by
ISTPage 31 of 103
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
Supplying and fixing of following sizes of medium class PVC conduit along with
237 1.21 accessories in surface/recess including cutting the wall and making good the same in - - - - -
case of recessed conduit as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate
switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box
excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover
plate for modular switches in recess etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on
246 1.32 surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular Each 144.00 - 586 631.01 - 90,864.88 -
socket outlet and 15/16 amps modular switch, connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact
fluorescent fitting of all types, complete with all accessories and tube etc. directly on
ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper
247 1.41 conductor, single core cable and earthing etc. as required. Each 144.00 - 206 221.82 - 31,942.26 -
Installation, testing and commissioning of ceiling fan, including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor,
single core cable, including providing and fixing phenolic laminated sheet cover on the
Installation of exhaust fan in the existing opening, including making good the damage,
249 1.50 connection, testing, commissioning etc. as required. - - - - -
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete
with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel ,MCB distribution
254 2.3 board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral bus - - - - -
bar, earth bar, din bar, interconnections powder painted including earthing etc. as
required. (But with out MCB/RCCB/ Isolator).
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel
256 2.4 ,MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper - - - - -
busbar, neutral bus bar, earth bar, din bar, interconnections powder painted including
earthing etc. as required. (But with out MCB/RCCB/ Isolator).
supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C Curve, miniature circuit
258 2.10 breaker suitable for inductive load of following poles in the existing MCB DB complete - - - - -
with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,double pole,240 V,isolator in the existing MCB DB
complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,four pole,415 V,isolator in the existing MCB DB
complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,double pole,240 V,residual current circuit breaker
264 2.14 (RCCB),having a sensitivity currrent 30 mA in the eiting MCB DB completed with - - - - -
connection ,teting commisoining etc.as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip
earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer
etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt
& spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along
with existing surface/ recessed conduit/ submain wiring/ cable as required.
269 FITTING & FIXTURES - - - - -
Supply, Installation, Testing & Commissioning of recessed type down lighter complete
270 NS-11 with lamps & accessories 18 W Philips Model No:DN296B LED 20S-6500 PSE WH S2/ Each 72.00 - - 1,470.79 - - 1,05,897.09
Havells Model: INTEGRANEODLR18WLED865S or equivalent
Supply, Installation, Testing & Commissioning of recess type 2x2, 36watt LED Light
271 NS-12 Fixtures complete with lamps & accessories.Philips Model No:RC380B LED 36S/ Havells Each 48.00 - - 7,295.13 - - 3,50,166.38
Model: VENUSNEO2X2PLR36WLED865G2 or equivalent
Digitally signed by
ISTPage 32 of 103
DSR-2022 E/M Amount (DSR
Rate- Amount (DSR-2023)
DSR-2023 Rate (incl. DSR 2022 Rate (incl. CF 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS Civil NS AMOUNT
CF 0.973 + CI 7%) E/M Rate 0.973+CI 6.33%) E/M with
with correction factor
4.08% ) correction factor
Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated,
ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos.
blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding,
Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery
minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%,
remote or electronic regulator unit for speed control and all remaining accessories
272 19.1 including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), Each 60.00 - 2730 2,939.67 - 1,76,380.2 -
insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC
Supply, earthing etc. complete as required.
Supplying of approved make Exaust Fan of the following size and its all accessories
273 NS-13 suitable for operation on 230V single phase, 50 Hz, AC supply complete as required.- Each 60.00 - - 2,432.8 - - 1,45,965.71
Providing and fixing GRC Jali 40 mm thick as per required opening size & all heights
274 NS-53 with all complete as per direction Engineer In Charge. Sqm 100.00 - - 4,747.4 4,74,738.04
Supplying Installation, testing and commissioning of 25 lt.Geyser with all complete as
275 NS-55 per direction Engineer In Charge. Each 24.00 - - 8,637.3 2,07,295.97
Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of engineer-in-charge. (No extra Cost )-
Laminated Clear Toughned glass -6 mm
Providing and fixing Granite quadrant of 250 mm dia bathroom corner self with all
respect complete 24 415.3
Supply, Installation, Testing & Commissioning of flood light 80watt with all respect
complete. 10 7,572.4
Providing and fixing Aluminium Ventilator Louvers with 5 mm thick glass with all respect
complete. 36 4,952.5
Digitally signed by
ISTPage 33 of 103
BOQ- Warden Residence-1
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
1 2.0 EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
2 2.6 over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan)
including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth
to be levelled and neatly dressed.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
4 2.25 foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited cum 96.41 196.00 204.06 - - 19,673.24 - -
layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Supplying and filling in plinth with sand under floors including watering, ramming
consolidating and dressing complete.
6 2.34 Supplying chemical emulsion in sealed containers including delivery as specified. - - - - - -
7 2.34.1 Chlorpyriphos/Lindane Emulsifiable concentrate of 20%. Ltr. 2.50 234.75 244.40 - - 611.00 - -
Diluting and injecting chemical emulsion for Post - CONSTRUCTIONAL anti-termite
treatment (excluding the cost of chemical emulsion)
Along external wall where the apron is not provided using chemical emulsion @ 7.5
9 2.35.1 litres / sqm of the vertical surface of the substructure to a depth of 300mm including - - - - -
excavation channel along the wall & rodding etc. complete:
10 2.35.1.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration Metre 15.00 38.9 40.50 - 607.49 - -
Treatment of soil under existing floors using chemical emulsion @ one litre per hole,
11 2.35.3 300 mm apart including drilling 12 mm dia holes and plugging with cement mortar 1:2 - - - - - -
(1 cement :2 coarse sand ) to match the existing floor.
12 2.35.3.1 With Chlorpyriphos /Lindane E C. 20% with 1% concentration. Sqm 50.00 310.05 322.80 - - 16,139.81 - -
13 4.0 CONCRETE WORK - - - - - -
Providing and laying in position cement concrete of specified grade excluding the cost of
cantering and shuttering - All work up to plinth level
15 4.1.8 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) cum 30.58 6812.00 7,092.04 - - 2,16,859.11 - -
1:5:10 (1 cement : 5 coarse sand(zone -III) derived from natural soueces : 10 graded
stone aggregate 40 mm nominal size Derived from natural soueces
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1
17 4.10 cement : 2 coarse sand(zone -III) derived from natural soueces : 4 graded stone Sqm 18.40 410.85 427.74 - - 7,870.42 - -
aggregate 12.5 mm nominal size derived from natural soueces.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3
manufactured sand (zone-III) derived from natural sources : 6 graded stone aggregate
18 4.17 20 mm nominal size derived from natural sources over 75mm thick bed of dry brick Sqm 37.50 749.30 780.10 - - 29,253.89 - -
ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,
including necessary excavatin, levelling & dressing & finishing the top smooth.
20 5.9 Centring and shuttering including strutting, propping etc. and removal of form for: - - - - - -
21 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. sqm 44.78 392.15 408.27 - - 18,280.35 - -
22 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 110.50 927.25 965.37 - - 1,06,673.30 - -
23 5.9.5 Lintels, beams, plinth beams, girders, bressummers and cantilevers. Sqm 82.40 736.40 766.67 - - 63,173.89 - -
24 5.9.6 Columns, Pillars, Piers, Abutments, posts and Struts Sqm 127.46 961.30 1,000.82 - - 1,27,566.90 - -
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
26 5.22.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 1356.95 107.85 112.28 - - 1,52,363 - -
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
28 5.22A.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 838.80 107.85 112.28 - - 94,184 - -
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade
for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to
29 5.33 site of laying , excluding the cost of cantering, shuttering finishing and reinforcement, - - - - - -
including cost of admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately).
30 All works upto plinth level - - - - - -
31 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 13.57 9504.75 9,895.49 - - 1,34,277 - -
Digitally signed by
ISTPage 34 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
32 All works above plinth level upto floor V level - - - - - -
33 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 8.39 9860.40 10,265.76 - - 86,109 - -
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5
in foundation and plinth
36 6.1.2 Cement mortar 1:6 (1 cement: 6 coarse sand) Cum 23.74 7,132.25 7,425.46 - 1,76,289
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third
course of half brick masonry.
Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in
superstructure above plinth level up to floor five level in :
Half brick masonry with non modular fly ash bricks of class designation 10, conforming
to IS: 12894, in superstructure above plinth up to floor V level.
42 8.0 CLADDING WORK - - - - - -
Providing and fixing 18mm thick gang saw cut mirror polished remoulded and
repolished) machine cut for kitchen platforms, vanity counters, window sills , facias and
similar locations of required size of approved shade, colour and texture laid over 20mm
43 8.2 thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white - - - - - -
cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc. complete at all levels.
44 8.2.3 Granite stone slab of all colourand texture expect black,Cherry/ Ruby Red - - - - - -
Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including
46 8.3 machine polishing to edge to give high gloss finish etc. complete as per design - - - - - -
approved by Engineer-in-Charge.
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia
48 8.4 and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning metre 4.00 568.55 591.92 - - 2,367.69 - -
Extra for providing opening of required size & shape for wash basins / kitchen sink in
49 8.5 kitchen platform, vanity counters and similar location in marble / Granite / stone work Each 2.00 978.70 1,018.93 - - 2,037.87 - -
including necessary holes for pillar taps etc. Including rubbing and polishing necessary
Providing wood work in frames of doors, windows, clerestory windows and other
51 9.1 frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners - - -
of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing 19 mm thick both side balancing laminationfactory pressed BWP
grade marine ply as per IS : 710 of approved brand
boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws
53 9.169 etc. complete as per direction of Engineer-incharge Sqm 8.46 2593.15 2,699.75 - - 22,839.92 - -
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)
54 9.21 non-decorative type, core of block board construction with frame of 1st class hard wood - - - - - -
and well matched commercial 3 ply veneering with vertical grains or cross bands and
face veneers on both faces of shutters :
55 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 12.60 2392.65 2,491.01 - - 31,386.75 - -
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on
all edges of flush door shutters (over all area of door shutter to be measured).
Extra for cutting rebate in flush door shutters (Total area of the shutter to be
Providing & fixing bright finished brass 100mm mortice latch and lock with 6 levers and
58 9.76 a pair of lever handles with necessary screws etc. complete (Best make of approved Each 2.00 854.65 889.78 - - 1,779.57 - -
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating
59 9.96 not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or - - - - - -
shade with nuts and screws etc. complete:
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less
61 9.97 than grade AC 10 as per IS : 1868 ) transparent or dyed toreqired colour or shade with - - - - - -
necessary screws etc.
Digitally signed by
ISTPage 35 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less
63 9.100 than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade - - - - - -
with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic
65 9.101 coating not less than grade AC 10 as per IS :1868) transparent or dyed to required - - - - - -
colour or shade with necessary screws etc. complete:
Providing & fixing special quality bright finished brass Cupboard or ward robe locks with
67 9.79 four levers including necessary screws etc. complete (best make of approved quality). - - - - - -
Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe
shutters, including fixing with necessary screws etc. complete.
71 9.114.2 Double strip (horizontal type) Each 2 39.7 41.33 - - 82.66 - -
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in
72 9.127 gloss / matt / suede finish with high density protective surface layer and reverse side of - - -
adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of
approved quality.
Providing and fixing factory made uPVC glazed/wire mesh windows/comprising of lead
free uPVC multi-chambered frame, sash and mullion/coupler (where ever required)
extruded profiles having minimum wall thickness of 1.7 mm for series R1 and R2
profiles and 2.1 mm for series R3 and R4 profiles confirming to EN:12608 in any shape,
colure and design duly reinforced with galvanized mild steel section made of required
shape & size as per CPWD Speifications ,upvc extructed glazing beads ,interlocks and
inline sash adaptor (where ever required ) of appropriate dimension ,EPDM gasket,
stainless steel SS 304 grade fastners of minimum 8 mm dia with countersunk head
,comprising of matching polymade PA6 grade sleeve for fixing frame to finishing wall as
74 9.147A per IS 1367 : Part 1 to 14 coated) casement handles, G.I fasteners 100 x 8 mm size - - -
for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless
steel screws etc. Profile of frame & sash mullion ( if required ) shall be mitred cut and
fusion welded /mechanically jointed duly sealed at all corners, including drilling of holes
for fixing hardware's and drainage of water etc. After fixing frame the gap between
frame and adjacent finished wall shall be filled with weather proof silicon sealant over
backer rod of required size and of approved quality, all complete as per approved
drawing comprising to CPWD Specification & direction of Engineer-in-Charge. section of
steel reinforcement and cross section of UPVC Profile to be as per design approved by
Engineer-in-Charge.
Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without
75 high performance coatings as per design requirements and conforming to IS: 3548 & - - -
IS: 16231 shall be paid separately
Note:- Structural design proof checked from a Government Engineering Institute, to be
provided by the manufacturer for
77 (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 - - -
78 (ii) Sites with structure height more than 20m for all wind speeds - - -
Using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm &
79 9.147.A1.3 above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every Sqm 9.00 9628.6 10,024.43 - 90,219.89
panel along with multi-point locking system (Height above 1.8m)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
flats, square or round bars etc. including priming coat withapproved steel primer all
81 9.48.1 Fixed to steel window by welding kg 72.00 219.1 228.11 - - 16,423.72 - -
Digitally signed by
ISTPage 36 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC
polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers
(wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index
of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and
screwed with full body threaded star headed SS screws having minimum frame density
82 26.86 of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum - - - - -
compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to
spread of flame of Class A category with property of being termite/borer proof,
water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS
dash fasteners of required dia and length complete as per direction of Engineer-In-
Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).
Note: For WPC solid door/window frames, minus 5 mm tolerance in profile dimensions
on plus side shall be acceptable but no extra payment on this account shall be made
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
board one side white color and other side of board laminited with pvc foil of minium 14
micron thickness of approved design pasted with hot melt adhesive for cup boards,work
station and bathroom /kitchen cabinet etc.of required sizes comprising of virgin polymer
of K (value 58-60 (suspension grade ), calcium carbonate and natural fibers (wood
powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12
for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of
85 26.89 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of - - - - -
elasticity 850 N/mm2 and resistance to spread of flame of Class A category with
property of being termite/borer proof, water/moisture proof and fire retardant and
fixing with stainless steel piano hinges /soft close clip on concealed hinges of required
size with necessary full body threaded star headed counter sunk S.S screws, all as per
direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft clip on
concealed hinges and necessary S.S screws shall be paid separately).
87 NS-18 Providing and fixing Magic eye with all respect complete. Each 1.00 - - 164.45 - - 164.45
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan
clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with
89 10.18 its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ Each 2 220.65 229.72 - - 459.44 - -
M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners.
Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels,
plates etc., including welding, grinding, buffing, polishing and making curvature
(wherever required) and fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories & stainless steel dash
90 10.28 fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side Kg 3.00 772.40 804.15 - - 2,412.46 - -
of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless steel members shall be considered excluding
fixing accessories such as nuts, bolts, fasteners
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with
M.S. Flat 15x3 mm and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both
93 11.0 FLOORING WORK - - - - - -
Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS: 15622, of approved brand & manufacturer, in all colours
and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse
94 11.41A sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the - - - - - -
joints with white cement and matching pigments etc. The tiles must be cut
with the zero chipping diamond cutter only . Laying of tiles will be done
with the notch trowel, plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently and easily.
95 11.41A.1 Double charge vitrified tile polished finish of size - - - - - -
Digitally signed by
ISTPage 37 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
97 11.38 make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 sqm 1,369.37 - 11,639.66 -
mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey
cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and
matching pigments etc., complete. 8.50 1315.3
Providing and laying Ceramic glazed Wall tiles of size 600x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
98 NS-56 make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 sqm 45.36 - - 1453.489485 65,930.28
mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey
cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and
matching pigments etc., complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in
linear as well as curvilinear portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement
99 11.56 mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing - - - - - -
with white cement slurry admixed with pigment of matching shade including rubbing ,
curing and polishing etc. all complete as specified and as directed by the Engineer-in-
100 11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red sqm 91.20 3071.05 3,197.30 - - 2,91,593.84 - -
Providing and fixing 1 mm galvalume roof sheet AZ-150 ,660 MPA including ridge,
102 NS-1 flashing over lapping etc complete plan area should be measured nothing extra shall sqm 120.00 - - 598.01 - - 71,760.85
be paid for lap, profile. ( valley creast etc)
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm Painting top
of roofs with bitumen of approved quality @ 17kg per 10 sqm
103 12.15 impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the sqm - - - - -
slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil
104 12.15.1 With residual type petroleum bitumen of grade VG -10 sqm 120 166.2 173.03 - 20,763.90 - -
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses
etc., including cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer, including welding and bolted with special shaped washers etc.
106 10.16.1 Hot finished welded type tubes kg 792.00 194.4 202.39 - 1,60,294.29 - -
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm
diameter and weighing not less than 440 grams.
108 13.0 FINISHING WORK - - - - -
109 13.4 12 mm cement plaster of mix : - - - - -
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1
111 13.11 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 Sqm 200 518.55 539.87 - 1,07,973.52 - -
cement : 6 fine sand).
112 13.16 6 mm cement plaster to ceiling of mix : - - - - -
Distempering with1st quality acrylic distemper (ready mixed) having VOC content less
114 13.41 then 50 gram/litre of approved manufacture and of required shade and colour complete - - - - -
to achieve even shade and colour.
New work (two or more coats) over and including water tinnable priming coat with
cement primer having VOC content less then 50 gram/litre .
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50
116 13.48A gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt - - - - -
resistance exterior paint of required shade (Company Depot Tinted) with silicon
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming
coat of exterior primer applied @ 0.90 litre/10 sqm.
Painting with synthetic enamel paint of approved brand and manufacture of required
colour to give an even shade :
Two or more coats on new work over an under coat of suitable shade with ordinary
paint of approved brand and manufacture
Providing and applying white cement based putty of average thickness 1 mm, of
approved brand and manufacturer, over the plastered wall surface to prepare the
surface even and smooth complete.
Digitally signed by
ISTPage 38 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Wall painting with premium acrylic emulsion paint of interior grade, having
121 13.83 VOC (Volatile Organic Compound ) content less than 50 grams/ litre of - - - - -
approved brand and manufacture, including applying additional coats
wherever required to achieve even shade and colour.
123 21.0 ALUMINIUM WORK - - - - -
124 21.3.2 With float glass panes of 5.0 mm thickness(wt not less then 12.5 kg/sqm) sqm 4.00 1505.25 1,567.13 - 6,268.52 - -
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by
providing weather silicon sealant over backer rod of approved quality as per
125 21.8 architectural drawings and direction of Engineer-in-charge complete. - - - - -
127 WATER PROOFING - - - - -
Providing and laying water proofing treatment in sunken portion of WCs, bathrooms etc.
by applying cement slurry mixed with water proofing cement comopund consisting of
applying: a) First layer of slurry of cement @ 0.488 kg./Sqm mixed with water proofing
cement comound @ 0.253 kg./Sqm. This layer will be allowed to air cure for 4 hours. b)
128 22.5 Second layer of slurry of cement @ 0.242 kg./Sqm mixed with water proofing cement Sqm 12.00 617.05 642.42 - 7,709.00 - -
comopund @ 0.126 kg./Sqm. This layer will be allowed to air cure for 4 hours followed
with water curing for 48 hours. The rate includes preparation of surface, treatment and
sealing of all joints, corners, junctions of pipes and masonary with polymer mixed
Providing and laying in situ five course water proofing treatment with APP (Atactic
Polypropylene) modified Polymeric memberane over roof consisting of first coat of
bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20
kg/sqm, which shall onsist of blown type bitumen of grade 85/25 conforming to IS :
702, 3rd layer of roofing membrane APP modified Polymeric membrane .0 mm thick of
3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100
129 14.87 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric Sqm 20.00 532.05 553.92 - 11,078.45 - -
mix is protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall
be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1
cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of
cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished
neat (item of laying brick tiles shall be paid for separately).
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with
SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance> 0.75 on
waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in
130 12.55 the ratio of 1 :4 (1 cement : 4 coarse sand) and grouting the joints with mix of white Sqm 10.00 1703.95 1,774.00 - 17,739.99 - -
cement & marble powder in ratio of 1 :1, including rubbing and polishing of the surface
upto 3 cuts complete, including providing skirting upto 150 mm height along the
parapet walls in the same manner
131 26.0 NEW TECHNOLOGIES AND MATERIALS - - - - -
Digitally signed by
ISTPage 39 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595mm of approved texture, design and patterns
as per CPWD Specification 2019, to be laid in true horizontal level
suspended on inter-locking metal T-Grid of hot dipped galvanised
iron section of 0.33mmthick (galvanized @ 120 grams per sqm
including both sides)comprising of main-T runners of size 24x38
mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T of size 24x32 mm
of length 600mm to formgrid module of size 600 x 600 mm,
132 26.22 suspended from ceiling usinggalvanised mild steel items (galvanizing - - - - -
@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level
adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require,
fixed with Glavanised iron perimeter wall angle or size 24x24x0.40
mm of length 3000 mm to be fixed on periphey wall / partition with
the help of plastic rawl plugs at 450mm center to center and 40 mm
long dry wall S.S screws. The workshall be carried out as per
specifications,
Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595mm of approved texture, design and patterns
as per CPWD Specification 2019, to be laid in true horizontal level
suspended on inter-locking metal T-Grid of hot dipped galvanised
iron section of 0.33mmthick (galvanized @ 120 grams per sqm
including both sides)comprising of main-T runners of size 24x38
mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T of size 24x32 mm
of length 600mm to formgrid module of size 600 x 600 mm,
133 26.22.1 suspended from ceiling usinggalvanised mild steel items (galvanizing sqm 17.00 2207 2,297.73 - 39,061.41 - -
@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level
adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require,
fixed with Glavanised iron perimeter wall angle or size 24x24x0.40
mm of length 3000 mm to be fixed on periphey wall / partition with
the help of plastic rawl plugs at 450mm center to center and 40 mm
long dry wall S.S screws. The workshall be carried out as per
specifications,- With 15 mm thick Tegular edged light weight calcium sliciate false ceiling
17.0 SANITARY INSTALLATIONS
Note:-1. All Sanitarty fixture shal be low flow as mentioned below , where flow/ flush
rate of fixture shall be equivalent or lesser at 3 bar pressure( lpm/lpf) .
2. water closet flushing cistern (dual flush 3/6) urinals 2 lpm faucets (lavatory
,pantry,health) 6 lpm.
137 3.multiple sprinkler system native trees & vegetation shall be used. - - - - -
4.over flow rain water storage & reuse on site of at least 75% of total building water
demand of 2 days shall be provide .
5. Desalting & grease trap system along with the proper flitation for rain water
recharging shall be provided.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm
sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush
pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all
fittings and fixtures complete, including cutting and making good the walls and floors
140 17.1.1 wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm Each 1 6,767.40 7,045.61 - 7,046 - -
with integral type foot rests
Providing white vitreous china wall hung type European W.C. pan with white plastic seat
141 NS-2 and lid with C.P. brass hinges & rubber buffers, 3/6 liters dual flush type white vitreous Each 1 - - 17,916.68 - - 17,916.68
china low level flushing cistern fixed directly on W.C. pan with fittings and brackets
Digitally signed by
ISTPage 40 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm
142 17.7 C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting - - - - -
and making good the walls wherever require :
White Vitreous China Wash basin size 630x450 mm with a
single 15 mm C.P. brass pillar tap
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with
144 17.10 C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, - - - - -
cutting and making good the walls wherever required :
145 17.10.1 Kitchen sink with drain board - - - - -
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as
per the direction of Engineer-in-charge.
Providing & fixing PVC waste pipe for sink or wash basin including PVC waste fittings
149 17.28.1 Semi rigid pipe - - - - -
Providing and fixing 15mm C.P brass Sink Mixer for kitchen sink with swinging spout
complete. Including cutting and making good the walls wherever required .
152 Providing and Fixing of C.P. Brass Shower set comprising of : - - - - -
153 One No. CP brass Single Lever Concealed Diverter . - - - - -
154 One No. CP brass OH shower head & Shower Arm . - - - - -
155 One No. CP brass Bath Spout. - - - - -
156 Including cutting and making good the walls wherever required. - - - - -
157 NS-4 Shower set as described above. Set 2 - - 6,284.61 - - 12,569.22
Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved
158 17.31 quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP Each 2 1607.95 1,674.05 - 3,348.11 - -
brass screws and washers complete.
159 17.34 Providing and fixing toilet paper holder : - - - - -
Providing and fixing PTMT towel rail complete with brackets fixed to
161 17.73 wooden cleats with CP brass screws with concealed fittings arrangement of approved - - - - -
quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height
of 88 mm, weighing not less than 190 gms
Providing and fixing health faucet with 1 m long flexible tube and wall hook including all
fittings approved quality.
164 18.49 Providing & fixing CP brass bib cock of approved quality conforming IS 8931: - - - - -
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS
standards and weighing not less than 690 gms.
Providing and fixing CP brass angle valve for basin mixer and geyser points of approved
quality confirming IS: 8931:
170 WATER SUPPLY - - - - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
171 18.7 including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & - - - - -
fittings with one step CPVC solvent cement and testing of joints complete as per
direction of Engineer in Charge.
172 Internal work - Exposed on wall - - - - -
173 18.7.1 15 mm nominal outer dia Pipes Metre 6 286.80 298.59 - 1,791.54 - -
174 18.7.2 20 mm nominal outer dia Pipes Metre 6 335.00 348.77 - 2,092.63 - -
175 18.7.3 25 mm nominal outer dia Pipes Metre 6 401.55 418.06 - 2,508.35 - -
176 18.7.4 32 mm nominal outer dia Pipes Metre 6 518.75 540.08 - 3,240.45 - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
177 18.8 i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & - - - - -
fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in
178 Concealed work, including cutting chases and making good the walls etc. - - - - -
179 18.8.1 15 mm nominal outer dia Pipes Metre 6 497.80 518.26 - 3,109.59 - -
180 18.8.2 20 mm nominal outer dia Pipes Metre 6 537.60 559.70 - 3,358.20 - -
181 18.8.3 25 mm nominal outer dia Pipes Metre 6 627.25 653.04 - 3,918.22 - -
182 18.8.4 32 mm nominal outer dia Pipes Metre 6 739.30 769.69 - 4,618.16 - -
Digitally signed by
ISTPage 41 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing and placing on terrace (at all floor levels) polythene water storage tank of
183 18.48 approved brand and manufacture with cover and suitable locking arrangement and Litre 500 11.00 11.45 - 5,726.11 - -
making necessary holes for inlet , outlet and overflow pipes but without fittings and the
base support for tank.
184 INTERNAL DRAINAGE - - - - -
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm
diameter and weighing not less than 440 grams.
Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of
min 6 Kg/ Sq cm rating with fitting for waste pipe from fixtures to floor trap including
186 NS-7 reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level - - - - -
supported by clamp & hangers etc. The work includes cutting holes in wall/ floors/ slabs
and making good the same with cement concrete 1:2:4 complete as required.
Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all
194 NS-8-1 S-Trap type Floor Trap 110 x 110 mm (Long type-50 mm seal) Each 2.00 - - 777.41 - - 1,554.82
195 NS-8-2 P-Trap type Floor Trap 110 x 110 mm (Long type - 50 mm seal) Each 1.00 - - 451.83 - - 451.83
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of
196 19.1 cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of - - - - -
joints etc. complete :
198 EXTERNAL SEWEGE SYSTEM - - - - -
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
199 2.8 including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting - - - - -
out the excavated soil and disposal of surplus excavated soil as directed, within a lead
Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting
201 2.10 out the excavated soil, and then returning the soil as required, in layers not exceeding - - - - -
20 cm in depth, including consolidating each deposited layer by ramming, watering, etc.
and disposing of surplus excavated soil as directed, within a lead of 50 m :
202 2.10.1 All kinds of soil. - - - - -
203 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia Metre 4 352.15 366.63 - 1,466.51 - -
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating
204 19.4 brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size - - - - -
(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design:
206 19.4.3.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 1 2802.15 2,917.35 - 2,917.35 - -
Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse
sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone
aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick
207 19.7 with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat - - -
cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4
graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat
cement complete as per standard design
Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x
208 19.7.1 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg - - -
(weight of cover 23 kg and weight of frame 15 kg)
209 19.7.1.1 With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5 each 1.00 12,770.55 13,295.55 - 13,295.55
210 19.8 Extra for depth for manholes : - - - - -
212 19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 1 8825.40 9,188.21 - 9,188.21 - -
Digitally signed by
ISTPage 42 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable in surface / recessed medium class
214 1.10 PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point - - - - -
with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor
216 1.11 single core cable in surface / recessed medium class PVC conduit, 2 way modular Point 2.00 - 1562 1,681.97 - 3,363.93 -
switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC
insulated copper conductor single core cable etc as required.
Wiring for light/power plug with 2x4 Sq.mm FRLS PVC insulated, copper conductor,
217 1.12 single core cable in surface/recessed PVC conduit alongwith 1 No. 4 Sq.mm FRLS PVC Metre 12.00 - 334 359.65 - 4,315.82 -
insulated copper conductor single core cable for loop earthing as required.
Wiring for light/power plug with 4x4 Sq.mm FRLS PVC insulated, copper conductor,
218 1.13 single core cable in surface/recessed PVC conduit alongwith 2 Nos. 4 Sq.mm FRLS PVC Metre 12.00 - 537 578.24 - 6,938.91 -
insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS
219 1.14 PVC insulated copper conductor, single core cable in surface/ recessed medium class - - - - -
PVC conduit as required
Supplying and fixing of following sizes of medium class PVC conduit along with
225 1.21 accessories in surface/recess including cutting the wall and making good the same in - - - - -
case of recessed conduit as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate
switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box
excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover
plate for modular switches in recess etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on
234 1.32 surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular Each 4.00 - 586 631.01 - 2,524.02 -
socket outlet and 15/16 amps modular switch, connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact
fluorescent fitting of all types, complete with all accessories and tube etc. directly on
ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor,
single core cable, including providing and fixing phenolic laminated sheet cover on the
fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage,
connection, testing, commissioning etc. as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete
with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel ,MCB distribution
242 2.3 board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral bus - - - - -
bar, earth bar, din bar, interconnections powder painted including earthing etc. as
required. (But with out MCB/RCCB/ Isolator).
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel
244 2.4 ,MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper - - - - -
busbar, neutral bus bar, earth bar, din bar, interconnections powder painted including
earthing etc. as required. (But with out MCB/RCCB/ Isolator).
Digitally signed by
ISTPage 43 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C Curve, miniature circuit
246 2.10 breaker suitable for inductive load of following poles in the existing MCB DB complete - - - - -
with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,double pole,240 V,isolator in the existing MCB DB
complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,four pole,415 V,isolator in the existing MCB DB
complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,double pole,240 V,residual current circuit breaker
252 2.14 (RCCB),having a sensitivity currrent 30 mA in the eiting MCB DB completed with - - - - -
connection ,teting commisoining etc.as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip
255 5.9 earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer Metre 4.00 - 144 155.06 - 620.24 -
etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt
& spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along
with existing surface/ recessed conduit/ submain wiring/ cable as required.
257 FITTING & FIXTURES - - - - -
Supply, Installation, Testing & Commissioning of recessed type down lighter complete
with lamps & accessories 18 W Philips Model No:DN296B LED 20S-6500 PSE WH S2/
258 NS-11 Havells Model: INTEGRANEODLR18WLED865S or equivalent Each 2.00 - - 1,470.79 - - 2,941.59
Supply, Installation, Testing & Commissioning of recess type 2x2, 36watt LED Light
Fixtures complete with lamps & accessories.Philips Model No:RC380B LED 36S/ Havells
259 NS-12 Model: VENUSNEO2X2PLR36WLED865G2 or equivalent Each 2.00 - - 7,295.13 - - 14,590.27
Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated,
ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos.
blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding,
Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery
minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%,
remote or electronic regulator unit for speed control and all remaining accessories
260 19.1 including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), Each 2.00 - 2730 2,939.67 - 5,879.34 -
insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC
Supply, earthing etc. complete as required.
Supplying of approved make Exaust Fan of the following size and its all accessories
261 NS-13 suitable for operation on 230V single phase, 50 Hz, AC supply complete as required.- Each 1.00 - - 2,432.8 - - 2,432.76
Providing and fixing GRC Jali 40 mm thick as per required opening size & all heights
with all complete as per direction Engineer In Charge.
Supplying Installation, testing and commissioning of 25 lt.Geyser with all complete as
per direction Engineer In Charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and
264 NS-14 partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the Sqm 2 - - 1,637.6 3,275.20
architectural drawings and the directions of engineer-in-charge. (No extra Cost )-
Laminated Clear Toughned glass -6 mm
Providing and fixing Granite quadrant of 250 mm dia bathroom corner self with all
respect complete
Supply, Installation, Testing & Commissioning of flood light 80watt with all respect
Providing and fixing Aluminium Ventilator Louvers with 5 mm thick glass with all respect
Digitally signed by
ISTPage 44 of 103
BOQ- Warden Residence-2
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
1 2.0 EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
2 2.6 over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan)
including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth
to be levelled and neatly dressed.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
4 2.25 foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited cum 96.41 196.00 204.06 - - 19,673.24 - -
layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5 2.27 Supplying and filling in plinth with sand under floors including watering, ramming Cum 10.13 2123.75 2,211.06 - - 22,386.96 - -
consolidating and dressing complete.
6 2.34 Supplying chemical emulsion in sealed containers including delivery as specified. - - - - - -
7 2.34.1 Chlorpyriphos/Lindane Emulsifiable concentrate of 20%. Ltr. 2.50 234.75 244.40 - - 611.00 - -
8 2.35 Diluting and injecting chemical emulsion for Post - CONSTRUCTIONAL anti-termite - - - - - -
treatment (excluding the cost of chemical emulsion)
Along external wall where the apron is not provided using chemical emulsion @ 7.5
9 2.35.1 litres / sqm of the vertical surface of the substructure to a depth of 300mm including - - - - -
excavation channel along the wall & rodding etc. complete:
10 2.35.1.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration Metre 15.00 38.9 40.50 - 607.49 - -
Treatment of soil under existing floors using chemical emulsion @ one litre per hole,
11 2.35.3 300 mm apart including drilling 12 mm dia holes and plugging with cement mortar 1:2 - - - - - -
(1 cement :2 coarse sand ) to match the existing floor.
12 2.35.3.1 With Chlorpyriphos /Lindane E C. 20% with 1% concentration. Sqm 50.00 310.05 322.80 - - 16,139.81 - -
13 4.0 CONCRETE WORK - - - - - -
14 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of - - - - - -
cantering and shuttering - All work up to plinth level
15 4.1.8 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) cum 30.58 6812.00 7,092.04 - - 2,16,859.11 - -
1:5:10 (1 cement : 5 coarse sand(zone -III) derived from natural soueces : 10 graded
stone aggregate 40 mm nominal size Derived from natural soueces
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1
17 4.10 cement : 2 coarse sand(zone -III) derived from natural soueces : 4 graded stone Sqm 18.40 410.85 427.74 - - 7,870.42 - -
aggregate 12.5 mm nominal size derived from natural soueces.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3
manufactured sand (zone-III) derived from natural sources : 6 graded stone aggregate
18 4.17 20 mm nominal size derived from natural sources over 75mm thick bed of dry brick Sqm 37.50 749.30 780.10 - - 29,253.89 - -
ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,
including necessary excavatin, levelling & dressing & finishing the top smooth.
20 5.9 Centring and shuttering including strutting, propping etc. and removal of form for: - - - - - -
21 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. sqm 44.78 392.15 408.27 - - 18,280.35 - -
22 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 110.50 927.25 965.37 - - 1,06,673.30 - -
23 5.9.5 Lintels, beams, plinth beams, girders, bressummers and cantilevers. Sqm 82.40 736.40 766.67 - - 63,173.89 - -
24 5.9.6 Columns, Pillars, Piers, Abutments, posts and Struts Sqm 127.46 961.30 1,000.82 - - 1,27,566.90 - -
25 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in - - - - - -
position and binding all complete above plinth level.
26 5.22.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 1356.95 107.85 112.28 - - 1,52,363 - -
27 5.22 A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in - - - - - -
position and binding all complete above plinth level.
28 5.22A.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 838.80 107.85 112.28 - - 94,184 - -
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade
for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to
29 5.33 site of laying , excluding the cost of cantering, shuttering finishing and reinforcement, - - - - - -
including cost of admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately).
30 All works upto plinth level - - - - - -
31 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 13.57 9504.75 9,895.49 - - 1,34,277 - -
32 All works above plinth level upto floor V level - - - - - -
33 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 8.39 9860.40 10,265.76 - - 86,109 - -
Digitally signed by
ISTPage 45 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5
in foundation and plinth
36 6.1.2 Cement mortar 1:6 (1 cement: 6 coarse sand) Cum 23.74 7,132.25 7,425.46 - 1,76,289
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third
course of half brick masonry.
38 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in - - - - - -
superstructure above plinth level up to floor five level in :
Half brick masonry with non modular fly ash bricks of class designation 10, conforming
to IS: 12894, in superstructure above plinth up to floor V level.
42 8.0 CLADDING WORK - - - - - -
Providing and fixing 18mm thick gang saw cut mirror polished remoulded and
repolished) machine cut for kitchen platforms, vanity counters, window sills , facias and
similar locations of required size of approved shade, colour and texture laid over 20mm
43 8.2 thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white - - - - - -
cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc. complete at all levels.
44 8.2.3 Granite stone slab of all colourand texture expect black,Cherry/ Ruby Red - - - - - -
Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including
46 8.3 machine polishing to edge to give high gloss finish etc. complete as per design approved - - - - - -
by Engineer-in-Charge.
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia
48 8.4 and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning metre 4.00 568.55 591.92 - - 2,367.69 - -
Extra for providing opening of required size & shape for wash basins / kitchen sink in
49 8.5 kitchen platform, vanity counters and similar location in marble / Granite / stone work Each 2.00 978.70 1,018.93 - - 2,037.87 - -
including necessary holes for pillar taps etc. Including rubbing and polishing necessary
Providing wood work in frames of doors, windows, clerestory windows and other
51 9.1 frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners - - -
of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing 19 mm thick both side balancing laminationfactory pressed BWP
grade marine ply as per IS : 710 of approved brand
boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws
53 9.169 etc. complete as per direction of Engineer-incharge Sqm 8.46 2593.15 2,699.75 - - 22,839.92 - -
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)
54 9.21 non-decorative type, core of block board construction with frame of 1st class hard wood - - - - - -
and well matched commercial 3 ply veneering with vertical grains or cross bands and
face veneers on both faces of shutters :
55 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 12.60 2392.65 2,491.01 - - 31,386.75 - -
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on
all edges of flush door shutters (over all area of door shutter to be measured).
Extra for cutting rebate in flush door shutters (Total area of the shutter to be
Providing & fixing bright finished brass 100mm mortice latch and lock with 6 levers and
58 9.76 a pair of lever handles with necessary screws etc. complete (Best make of approved Each 2.00 854.65 889.78 - - 1,779.57 - -
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating
59 9.96 not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or - - - - - -
shade with nuts and screws etc. complete:
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less
61 9.97 than grade AC 10 as per IS : 1868 ) transparent or dyed toreqired colour or shade with - - - - - -
necessary screws etc.
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less
63 9.100 than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade - - - - - -
with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic
65 9.101 coating not less than grade AC 10 as per IS :1868) transparent or dyed to required - - - - - -
colour or shade with necessary screws etc. complete:
Digitally signed by
ISTPage 46 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing & fixing special quality bright finished brass Cupboard or ward robe locks with
67 9.79 four levers including necessary screws etc. complete (best make of approved quality). - - - - - -
Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe
shutters, including fixing with necessary screws etc. complete.
71 9.114.2 Double strip (horizontal type) Each 2 39.7 41.33 - - 82.66 - -
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in
72 9.127 gloss / matt / suede finish with high density protective surface layer and reverse side of - - -
adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of
approved quality.
Providing and fixing factory made uPVC glazed/wire mesh windows/comprising of lead
free uPVC multi-chambered frame, sash and mullion/coupler (where ever required)
extruded profiles having minimum wall thickness of 1.7 mm for series R1 and R2
profiles and 2.1 mm for series R3 and R4 profiles confirming to EN:12608 in any shape,
colure and design duly reinforced with galvanized mild steel section made of required
shape & size as per CPWD Speifications ,upvc extructed glazing beads ,interlocks and
inline sash adaptor (where ever required ) of appropriate dimension ,EPDM gasket,
stainless steel SS 304 grade fastners of minimum 8 mm dia with countersunk head
,comprising of matching polymade PA6 grade sleeve for fixing frame to finishing wall as
74 9.147A per IS 1367 : Part 1 to 14 coated) casement handles, G.I fasteners 100 x 8 mm size - - -
for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless
steel screws etc. Profile of frame & sash mullion ( if required ) shall be mitred cut and
fusion welded /mechanically jointed duly sealed at all corners, including drilling of holes
for fixing hardware's and drainage of water etc. After fixing frame the gap between
frame and adjacent finished wall shall be filled with weather proof silicon sealant over
backer rod of required size and of approved quality, all complete as per approved
drawing comprising to CPWD Specification & direction of Engineer-in-Charge. section of
steel reinforcement and cross section of UPVC Profile to be as per design approved by
Engineer-in-Charge.
Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without
75 high performance coatings as per design requirements and conforming to IS: 3548 & - - -
IS: 16231 shall be paid separately
76 Note:- Structural design proof checked from a Government Engineering Institute, to be - - -
provided by the manufacturer for
77 (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 - - -
78 (ii) Sites with structure height more than 20m for all wind speeds - - -
Using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm &
79 9.147.A1.3 above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every Sqm 9.00 9628.6 10,024.43 - 90,219.89
panel along with multi-point locking system (Height above 1.8m)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
flats, square or round bars etc. including priming coat withapproved steel primer all
81 9.48.1 Fixed to steel window by welding kg 72.00 219.1 228.11 - - 16,423.72 - -
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC
polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers
(wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index
of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and
screwed with full body threaded star headed SS screws having minimum frame density
82 26.86 of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum - - - - -
compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to
spread of flame of Class A category with property of being termite/borer proof,
water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS
dash fasteners of required dia and length complete as per direction of Engineer-In-
Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).
83 Note: For WPC solid door/window frames, minus 5 mm tolerance in profile dimensions - - - - -
on plus side shall be acceptable but no extra payment on this account shall be made
Digitally signed by
ISTPage 47 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
board one side white color and other side of board laminited with pvc foil of minium 14
micron thickness of approved design pasted with hot melt adhesive for cup boards,work
station and bathroom /kitchen cabinet etc.of required sizes comprising of virgin polymer
of K (value 58-60 (suspension grade ), calcium carbonate and natural fibers (wood
powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12
for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of
85 26.89 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of - - - - -
elasticity 850 N/mm2 and resistance to spread of flame of Class A category with
property of being termite/borer proof, water/moisture proof and fire retardant and
fixing with stainless steel piano hinges /soft close clip on concealed hinges of required
size with necessary full body threaded star headed counter sunk S.S screws, all as per
direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft clip on
concealed hinges and necessary S.S screws shall be paid separately).
87 NS-18 Providing and fixing Magic eye with all respect complete. Each 1.00 - - 164.45 - - 164.45
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan
clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with
89 10.18 its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ Each 2 220.65 229.72 - - 459.44 - -
M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners.
Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels,
plates etc., including welding, grinding, buffing, polishing and making curvature
(wherever required) and fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories & stainless steel dash
90 10.28 fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side Kg 3.00 772.40 804.15 - - 2,412.46 - -
of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless steel members shall be considered excluding
fixing accessories such as nuts, bolts, fasteners
91 10.29 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with - - -
M.S. Flat 15x3 mm and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both
93 11.0 FLOORING WORK - - - - - -
Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS: 15622, of approved brand & manufacturer, in all colours
and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse
94 11.41A sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the - - - - - -
joints with white cement and matching pigments etc. The tiles must be cut
with the zero chipping diamond cutter only . Laying of tiles will be done
with the notch trowel, plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently and easily.
95 11.41A.1 Double charge vitrified tile polished finish of size - - - - - -
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
97 11.38 make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 sqm 1,369.37 - 11,639.66 -
mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey
cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and
matching pigments etc., complete. 8.50 1315.3
Providing and laying Ceramic glazed Wall tiles of size 600x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
98 NS-56 make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 sqm 45.36 - - 1453.489485 65,930.28
mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey
cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and
matching pigments etc., complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in
linear as well as curvilinear portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement
99 11.56 mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing - - - - - -
with white cement slurry admixed with pigment of matching shade including rubbing ,
curing and polishing etc. all complete as specified and as directed by the Engineer -in-
100 11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red sqm 91.20 3071.05 3,197.30 - - 2,91,593.84 - -
Digitally signed by
ISTPage 48 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing and fixing 1 mm galvalume roof sheet AZ-150 ,660 MPA including ridge,
102 NS-1 flashing over lapping etc complete plan area should be measured nothing extra shall sqm 120.00 - - 598.01 - - 71,760.85
be paid for lap, profile. ( valley creast etc)
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm Painting top
of roofs with bitumen of approved quality @ 17kg per 10 sqm
103 12.15 impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the sqm - - - - -
slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil
104 12.15.1 With residual type petroleum bitumen of grade VG -10 sqm 120 166.2 173.03 - 20,763.90 - -
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses
105 10.16 etc., including cutting, hoisting, fixing in position and applying a priming coat of - - - - -
approved steel primer, including welding and bolted with special shaped washers etc.
106 10.16.1 Hot finished welded type tubes kg 792.00 194.4 202.39 - 1,60,294.29 - -
107 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm Each 2 54.7 56.95 - 113.90 - -
diameter and weighing not less than 440 grams.
108 13.0 FINISHING WORK - - - - -
109 13.4 12 mm cement plaster of mix : - - - - -
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1
111 13.11 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 Sqm 200 518.55 539.87 - 1,07,973.52 - -
cement : 6 fine sand).
112 13.16 6 mm cement plaster to ceiling of mix : - - - - -
Distempering with1st quality acrylic distemper (ready mixed) having VOC content less
114 13.41 then 50 gram/litre of approved manufacture and of required shade and colour complete - - - - -
to achieve even shade and colour.
New work (two or more coats) over and including water tinnable priming coat with
cement primer having VOC content less then 50 gram/litre .
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50
116 13.48A gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt - - - - -
resistance exterior paint of required shade (Company Depot Tinted) with silicon
117 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming Sqm 200 181.25 188.70 - 37,740.24 - -
coat of exterior primer applied @ 0.90 litre/10 sqm.
Painting with synthetic enamel paint of approved brand and manufacture of required
colour to give an even shade :
Two or more coats on new work over an under coat of suitable shade with ordinary
paint of approved brand and manufacture
Providing and applying white cement based putty of average thickness 1 mm, of
approved brand and manufacturer, over the plastered wall surface to prepare the
surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having
121 13.83 VOC (Volatile Organic Compound ) content less than 50 grams/ litre of - - - - -
approved brand and manufacture, including applying additional coats
wherever required to achieve even shade and colour.
123 21.0 ALUMINIUM WORK - - - - -
124 21.3.2 With float glass panes of 5.0 mm thickness(wt not less then 12.5 kg/sqm) sqm 4.00 1505.25 1,567.13 - 6,268.52 - -
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by
providing weather silicon sealant over backer rod of approved quality as per
125 21.8 architectural drawings and direction of Engineer-in-charge complete. - - - - -
127 WATER PROOFING - - - - -
Providing and laying water proofing treatment in sunken portion of WCs, bathrooms etc.
by applying cement slurry mixed with water proofing cement comopund consisting of
applying: a) First layer of slurry of cement @ 0.488 kg./Sqm mixed with water proofing
cement comound @ 0.253 kg./Sqm. This layer will be allowed to air cure for 4 hours. b)
128 22.5 Second layer of slurry of cement @ 0.242 kg./Sqm mixed with water proofing cement Sqm 12.00 617.05 642.42 - 7,709.00 - -
comopund @ 0.126 kg./Sqm. This layer will be allowed to air cure for 4 hours followed
with water curing for 48 hours. The rate includes preparation of surface, treatment and
sealing of all joints, corners, junctions of pipes and masonary with polymer mixed
Digitally signed by
ISTPage 49 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing and laying in situ five course water proofing treatment with APP (Atactic
Polypropylene) modified Polymeric memberane over roof consisting of first coat of
bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20
kg/sqm, which shall onsist of blown type bitumen of grade 85/25 conforming to IS :
702, 3rd layer of roofing membrane APP modified Polymeric membrane .0 mm thick of
129 14.87 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 Sqm 20.00 532.05 553.92 - 11,078.45 - -
micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric
mix is protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall
be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1
cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of
cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished
neat (item of laying brick tiles shall be paid for separately).
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with
SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance> 0.75 on
waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in
130 12.55 the ratio of 1 :4 (1 cement : 4 coarse sand) and grouting the joints with mix of white Sqm 10.00 1703.95 1,774.00 - 17,739.99 - -
cement & marble powder in ratio of 1 :1, including rubbing and polishing of the surface
upto 3 cuts complete, including providing skirting upto 150 mm height along the
parapet walls in the same manner
131 26.0 NEW TECHNOLOGIES AND MATERIALS - - - - -
Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595mm of approved texture, design and patterns
as per CPWD Specification 2019, to be laid in true horizontal level
suspended on inter-locking metal T-Grid of hot dipped galvanised
iron section of 0.33mmthick (galvanized @ 120 grams per sqm
including both sides)comprising of main-T runners of size 24x38
mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T of size 24x32 mm
of length 600mm to formgrid module of size 600 x 600 mm,
132 26.22 suspended from ceiling usinggalvanised mild steel items (galvanizing - - - - -
@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level
adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require,
fixed with Glavanised iron perimeter wall angle or size 24x24x0.40
mm of length 3000 mm to be fixed on periphey wall / partition with
the help of plastic rawl plugs at 450mm center to center and 40 mm
long dry wall S.S screws. The workshall be carried out as per
specifications,
Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595mm of approved texture, design and patterns
as per CPWD Specification 2019, to be laid in true horizontal level
suspended on inter-locking metal T-Grid of hot dipped galvanised
iron section of 0.33mmthick (galvanized @ 120 grams per sqm
including both sides)comprising of main-T runners of size 24x38
mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T of size 24x32 mm
of length 600mm to formgrid module of size 600 x 600 mm,
133 26.22.1 suspended from ceiling usinggalvanised mild steel items (galvanizing sqm 17.00 2207 2,297.73 - 39,061.41 - -
@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level
adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require,
fixed with Glavanised iron perimeter wall angle or size 24x24x0.40
mm of length 3000 mm to be fixed on periphey wall / partition with
the help of plastic rawl plugs at 450mm center to center and 40 mm
long dry wall S.S screws. The workshall be carried out as per
specifications, - With 15 mm thick Tegular edged light weight calcium sliciate false ceiling
134 17.0 SANITARY INSTALLATIONS - - - - -
Note:-1. All Sanitarty fixture shal be low flow as mentioned below , where flow/ flush
rate of fixture shall be equivalent or lesser at 3 bar pressure( lpm/lpf) .
2. water closet flushing cistern (dual flush 3/6) urinals 2 lpm faucets (lavatory
,pantry,health) 6 lpm.
137 3.multiple sprinkler system native trees & vegetation shall be used. - - - - -
4.over flow rain water storage & reuse on site of at least 75% of total building water
demand of 2 days shall be provide .
139 5. Desalting & grease trap system along with the proper flitation for rain water - - - - -
recharging shall be provided.
Digitally signed by
ISTPage 50 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm
sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush
140 17.1.1 pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all Each 1 6,767.40 7,045.61 - 7,046 - -
fittings and fixtures complete, including cutting and making good the walls and floors
wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm
with integral type foot rests
Providing white vitreous china wall hung type European W.C. pan with white plastic seat
141 NS-2 and lid with C.P. brass hinges & rubber buffers, 3/6 liters dual flush type white vitreous Each 1 - - 17,916.68 - - 17,916.68
china low level flushing cistern fixed directly on W.C. pan with fittings and brackets
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm
142 17.7 C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting - - - - -
and making good the walls wherever require :
White Vitreous China Wash basin size 630x450 mm with a
single 15 mm C.P. brass pillar tap
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with
144 17.10 C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, - - - - -
cutting and making good the walls wherever required :
145 17.10.1 Kitchen sink with drain board - - - - -
147 17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as Each 1.00 1034.80 1,077.34 - 1,077.34 - -
per the direction of Engineer-in-charge.
148 17.28 Providing & fixing PVC waste pipe for sink or wash basin including PVC waste fittings - - - - -
149 17.28.1 Semi rigid pipe - - - - -
151 NS-3 Providing and fixing 15mm C.P brass Sink Mixer for kitchen sink with swinging spout Each 1 - - 4,042.09 - - 4,042.09
complete. Including cutting and making good the walls wherever required .
152 Providing and Fixing of C.P. Brass Shower set comprising of : - - - - -
153 One No. CP brass Single Lever Concealed Diverter . - - - - -
154 One No. CP brass OH shower head & Shower Arm . - - - - -
155 One No. CP brass Bath Spout. - - - - -
156 Including cutting and making good the walls wherever required. - - - - -
157 NS-4 Shower set as described above. Set 2 - - 6,284.61 - - 12,569.22
Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved
158 17.31 quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP Each 2 1607.95 1,674.05 - 3,348.11 - -
brass screws and washers complete.
159 17.34 Providing and fixing toilet paper holder : - - - - -
Providing and fixing PTMT towel rail complete with brackets fixed to
161 17.73 wooden cleats with CP brass screws with concealed fittings arrangement of approved - - - - -
quality and colour.
162 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height Each 2 708.95 738.09 - 1,476.19 - -
of 88 mm, weighing not less than 190 gms
163 NS-5 Providing and fixing health faucet with 1 m long flexible tube and wall hook including all Each 2 - - 1,411.96 - - 2,823.92
fittings approved quality.
164 18.49 Providing & fixing CP brass bib cock of approved quality conforming IS 8931: - - - - -
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS
standards and weighing not less than 690 gms.
168 18.53 Providing and fixing CP brass angle valve for basin mixer and geyser points of approved - - - - -
quality confirming IS: 8931:
170 WATER SUPPLY - - - - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
171 18.7 including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & - - - - -
fittings with one step CPVC solvent cement and testing of joints complete as per
direction of Engineer in Charge.
172 Internal work - Exposed on wall - - - - -
173 18.7.1 15 mm nominal outer dia Pipes Metre 6 286.80 298.59 - 1,791.54 - -
174 18.7.2 20 mm nominal outer dia Pipes Metre 6 335.00 348.77 - 2,092.63 - -
175 18.7.3 25 mm nominal outer dia Pipes Metre 6 401.55 418.06 - 2,508.35 - -
176 18.7.4 32 mm nominal outer dia Pipes Metre 6 518.75 540.08 - 3,240.45 - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
177 18.8 i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & - - - - -
fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in
Digitally signed by
ISTPage 51 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
178 Concealed work, including cutting chases and making good the walls etc. - - - - -
179 18.8.1 15 mm nominal outer dia Pipes Metre 6 497.80 518.26 - 3,109.59 - -
180 18.8.2 20 mm nominal outer dia Pipes Metre 6 537.60 559.70 - 3,358.20 - -
181 18.8.3 25 mm nominal outer dia Pipes Metre 6 627.25 653.04 - 3,918.22 - -
182 18.8.4 32 mm nominal outer dia Pipes Metre 6 739.30 769.69 - 4,618.16 - -
Providing and placing on terrace (at all floor levels) polythene water storage tank of
183 18.48 approved brand and manufacture with cover and suitable locking arrangement and Litre 500 11.00 11.45 - 5,726.11 - -
making necessary holes for inlet , outlet and overflow pipes but without fittings and the
base support for tank.
184 INTERNAL DRAINAGE - - - - -
185 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm Each 2.00 54.70 56.95 - 113.90 - -
diameter and weighing not less than 440 grams.
Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of
min 6 Kg/ Sq cm rating with fitting for waste pipe from fixtures to floor trap including
186 NS-7 reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level - - - - -
supported by clamp & hangers etc. The work includes cutting holes in wall/ floors/ slabs
and making good the same with cement concrete 1:2:4 complete as required.
Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all
194 NS-8-1 S-Trap type Floor Trap 110 x 110 mm (Long type-50 mm seal) Each 2.00 - - 777.41 - - 1,554.82
195 NS-8-2 P-Trap type Floor Trap 110 x 110 mm (Long type - 50 mm seal) Each 1.00 - - 451.83 - - 451.83
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of
196 19.1 cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of - - - - -
joints etc. complete :
198 EXTERNAL SEWEGE SYSTEM - - - - -
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
199 2.8 including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting - - - - -
out the excavated soil and disposal of surplus excavated soil as directed, within a lead
Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting
201 2.10 out the excavated soil, and then returning the soil as required, in layers not exceeding - - - - -
20 cm in depth, including consolidating each deposited layer by ramming, watering, etc.
and disposing of surplus excavated soil as directed, within a lead of 50 m :
202 2.10.1 All kinds of soil. - - - - -
203 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia Metre 4 352.15 366.63 - 1,466.51 - -
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating
204 19.4 brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size - - - - -
(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design:
206 19.4.3.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 1 2802.15 2,917.35 - 2,917.35 - -
Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse
sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone
aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick
207 19.7 with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat - - -
cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4
graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat
cement complete as per standard design
Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x
208 19.7.1 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg - - -
(weight of cover 23 kg and weight of frame 15 kg)
209 19.7.1.1 With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5 each 1.00 12,770.55 13,295.55 - 13,295.55
210 19.8 Extra for depth for manholes : - - - - -
212 19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 1 8825.40 9,188.21 - 9,188.21 - -
Digitally signed by
ISTPage 52 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable in surface / recessed medium class
214 1.10 PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point - - - - -
with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor
216 1.11 single core cable in surface / recessed medium class PVC conduit, 2 way modular Point 2.00 - 1562 1,681.97 - 3,363.93 -
switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC
insulated copper conductor single core cable etc as required.
Wiring for light/power plug with 2x4 Sq.mm FRLS PVC insulated, copper conductor,
217 1.12 single core cable in surface/recessed PVC conduit alongwith 1 No. 4 Sq.mm FRLS PVC Metre 12.00 - 334 359.65 - 4,315.82 -
insulated copper conductor single core cable for loop earthing as required.
Wiring for light/power plug with 4x4 Sq.mm FRLS PVC insulated, copper conductor,
218 1.13 single core cable in surface/recessed PVC conduit alongwith 2 Nos. 4 Sq.mm FRLS PVC Metre 12.00 - 537 578.24 - 6,938.91 -
insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS
219 1.14 PVC insulated copper conductor, single core cable in surface/ recessed medium class - - - - -
PVC conduit as required
Supplying and fixing of following sizes of medium class PVC conduit along with
225 1.21 accessories in surface/recess including cutting the wall and making good the same in - - - - -
case of recessed conduit as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate
switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box
excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover
plate for modular switches in recess etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on
234 1.32 surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular Each 4.00 - 586 631.01 - 2,524.02 -
socket outlet and 15/16 amps modular switch, connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact
fluorescent fitting of all types, complete with all accessories and tube etc. directly on
ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor,
single core cable, including providing and fixing phenolic laminated sheet cover on the
fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage,
connection, testing, commissioning etc. as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete
with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel ,MCB distribution
242 2.3 board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral bus - - - - -
bar, earth bar, din bar, interconnections powder painted including earthing etc. as
required. (But with out MCB/RCCB/ Isolator).
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel
244 2.4 ,MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper - - - - -
busbar, neutral bus bar, earth bar, din bar, interconnections powder painted including
earthing etc. as required. (But with out MCB/RCCB/ Isolator).
supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C Curve, miniature circuit
246 2.10 breaker suitable for inductive load of following poles in the existing MCB DB complete - - - - -
with connectoin testing and commissioning etc.as required.
Digitally signed by
ISTPage 53 of 103
DSR-2023 DSR-2022 E/M Amount (DSR- Amount (DSR
Rate (incl. CF DSR 2022 Rate (incl. CF 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 Rate -NS NS AMOUNT
0.973 + CI E/M Rate 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
supplying and fixing following rating,double pole,240 V,isolator in the existing MCB DB
complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,four pole,415 V,isolator in the existing MCB DB
complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,double pole,240 V,residual current circuit breaker
252 2.14 (RCCB),having a sensitivity currrent 30 mA in the eiting MCB DB completed with - - - - -
connection ,teting commisoining etc.as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip
255 5.9 earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer Metre 4.00 - 144 155.06 - 620.24 -
etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt
& spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along
with existing surface/ recessed conduit/ submain wiring/ cable as required.
257 FITTING & FIXTURES - - - - -
Supply, Installation, Testing & Commissioning of recessed type down lighter complete
258 NS-11 with lamps & accessories 18 W Philips Model No:DN296B LED 20S-6500 PSE WH S2/ Each 2.00 - - 1,470.79 - - 2,941.59
Havells Model: INTEGRANEODLR18WLED865S or equivalent
Supply, Installation, Testing & Commissioning of recess type 2x2, 36watt LED Light
259 NS-12 Fixtures complete with lamps & accessories.Philips Model No:RC380B LED 36S/ Havells Each 2.00 - - 7,295.13 - - 14,590.27
Model: VENUSNEO2X2PLR36WLED865G2 or equivalent
Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated,
ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos.
blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding,
Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery
minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%,
remote or electronic regulator unit for speed control and all remaining accessories
including safety pin, nut bolts,washers, temperature rise=75 degree C (max.),
insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC
Supply, earthing etc. complete as required.
Supplying of approved make Exaust Fan of the following size and its all accessories
261 NS-13 suitable for operation on 230V single phase, 50 Hz, AC supply complete as required.- Each 1.00 - - 2,432.8 - - 2,432.76
262 NS-53 Providing and fixing GRC Jali 40 mm thick as per required opening size & all heights Sqm 3.00 - - 4,747.4 14,242.14
with all complete as per direction Engineer In Charge.
263 NS-55 Supplying Installation, testing and commissioning of 25 lt.Geyser with all complete as Each 1.00 - - 8,637.3 8,637.33
per direction Engineer In Charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and
264 NS-14 partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the Sqm 2 - - 1,637.6 3,275.20
architectural drawings and the directions of engineer-in-charge. (No extra Cost )-
Laminated Clear Toughned glass -6 mm
Providing and fixing Granite quadrant of 250 mm dia bathroom corner self with all
respect complete
Supply, Installation, Testing & Commissioning of flood light 80watt with all respect
267 NS-17 Providing and fixing Aluminium Ventilator Louvers with 5 mm thick glass with all respect Sqm 1 - - 4,952.5 4,952.52
Digitally signed by
ISTPage 54 of 103
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar -I (MH).
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
1 2.0 EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over
2 2.6 areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including
disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled
and neatly dressed.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations
4 2.25 etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming cum 178.61 196.00 204.06 - - 36,445.70 - -
and watering, lead up to 50 m and lift up to 1.5 m.
Supplying and filling in plinth with sand under floors including watering, ramming
consolidating and dressing complete.
6 2.28 Surface dressing of the ground including removing vegetation - - - - - -
7 2.28.1 All kinds of soil Sqm - - - - - -
8 2.34 Supplying chemical emulsion in sealed containers including delivery as specified. - - - - - -
9 2.34.1 Chlorpyriphos/Lindane Emulsifiable concentrate of 20%. Ltr. 8.00 234.75 244.40 - - 1,955.20 - -
Diluting and injecting chemical emulsion for Post - CONSTRUCTIONAL anti-termite treatment
(excluding the cost of chemical emulsion)
Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres /
11 2.35.1 sqm of the vertical surface of the substructure to a depth of 300mm including excavation - - -
channel along the wall & rodding etc. complete:
12 2.35.1.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration Metre 108 38.9 40.50 - 4,373.91
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300
13 2.35.3 mm apart including drilling 12 mm dia holes and plugging with cement mortar 1:2 (1 cement - - - - - -
:2 coarse sand ) to match the existing floor.
14 2.35.3.1 With Chlorpyriphos /Lindane E C. 20% with 1% concentration. Sqm 160.00 310.05 322.80 - - 51,647.38 - -
15 4.0 CONCRETE WORK - - - - - -
Providing and laying in position cement concrete of specified grade excluding the cost of
cantering and shuttering - All work up to plinth level
17 4.1.8 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) cum 32.23 6812.00 7,092.0 - - 2,28,543.69 - -
18 4.1.10 1:5:10 (1 cement : 5 coarse sand(zone -III) derived from natural soueces : 10 graded stone cum - - - - - -
aggregate 40 mm nominal size Derived from natural soueces
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement
19 4.10 : 2 coarse sand(zone -III) derived from natural soueces : 4 graded stone aggregate 12.5 Sqm 41.40 410.85 427.7 - - 17,708.44 - -
mm nominal size derived from natural soueces.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 manufactured
sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal
20 4.17 size derived from natural sources over 75mm thick bed of dry brick ballast 40 mm nominal Sqm 48.75 749.30 780.1 - - 38,030.06 - -
size, well rammed and consolidated and grouted with fine sand, including necessary
excavatin, levelling & dressing & finishing the top smooth.
22 5.9 Centring and shuttering including strutting, propping etc. and removal of form for: - - - - - -
23 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. sqm 62.91 392.15 408.3 - - 25,684.35 - -
24 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 204.00 927.25 965.4 - - 1,96,935.33 - -
25 5.9.5 Lintels, beams, plinth beams, girders, bressummers and cantilevers. Sqm 235.80 736.40 766.7 - - 1,80,781.59 - -
26 5.9.6 Columns, Pillars, Piers, Abutments, posts and Struts Sqm 120.51 961.30 1,000.8 - - 1,20,608.70 - -
27 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in - - - - - -
position and binding all complete above plinth level.
28 5.22.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 3560.54 107.85 112.3 - - 3,99,790 - -
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
30 5.22A.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 1873.94 107.85 112.3 - - 2,10,413 - -
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced
cement concrete work, including pumping of R.M.C. from transit mixer to site of laying ,
31 5.33 excluding the cost of cantering, shuttering finishing and reinforcement, including cost of - - - - - -
admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability as per direction of
the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used
as per design mix is payable/recoverable separately).
32 All works upto plinth level - - - - - -
33 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 32.37 9504.75 9,895.5 - - 3,20,302 - -
35 All works above plinth level upto floor V level - - - - - -
Digitally signed by
ISTPage 55 of 103
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
36 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 17.04 9860.40 10,265.8 - - 1,74,885 - -
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in
foundation and plinth
40 6.1.2 Cement mortar 1:6 (1 cement: 6 coarse sand) Cum 7,132.25 7,425.5 -
41 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of sqm 40.64 104.8 109.1 - - 4,434.16 - -
half brick masonry.
Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in
superstructure above plinth level up to floor five level in :
44 6.45 Half brick masonry with non modular fly ash bricks of class designation 10, conforming to - - - - - -
IS: 12894, in superstructure above plinth up to floor V level.
46 8.0 CLADDING WORK - - - - - -
Providing and fixing 18mm thick gang saw cut mirror polished remoulded and repolished)
machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations
47 8.2 of required size of approved shade, colour and texture laid over 20mm thick base cement - - - - - -
mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to
edges to give high gloss finish etc. complete at all levels.
48 8.2.3 Granite stone slab of all colourand texture expect black,Cherry/ Ruby Red - - - - - -
Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including
50 8.3 machine polishing to edge to give high gloss finish etc. complete as per design approved by - - - - - -
Engineer-in-Charge.
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and
52 8.4 drops of width up to 150 mm with epoxy resin based adhesive, including cleaning etc. metre 4.00 568.55 591.9 - - 2,367.69 - -
Extra for providing opening of required size & shape for wash basins / kitchen sink in kitchen
53 8.5 platform, vanity counters and similar location in marble / Granite / stone work including Each 4.00 978.70 1,018.9 - - 4,075.74 - -
necessary holes for pillar taps etc. Including rubbing and polishing necessary etc. complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames,
55 9.1 wrought framed and fixed in position with hold fast lugs or with dash fasteners of required - - -
dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing 19 mm thick both side balancing laminationfactory pressed BWP grade
marine ply as per IS : 710 of approved brand boxes,shelves,racks,almirah,cupboard and
drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-
58 9.21 decorative type, core of block board construction with frame of 1st class hard wood and well - - - - - -
matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on
both faces of shutters :
59 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 22.68 2392.65 2,491.0 - - 56,496.15 - -
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all
edges of flush door shutters (over all area of door shutter to be measured).
61 9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). sqm 22.68 106.7 111.1 - - 2,519.44 - -
Providing & fixing bright finished brass 100mm mortice latch and lock with 6 levers and a
62 9.76 pair of lever handles with necessary screws etc. complete (Best make of approved quality). Each 8 854.65 889.8 - - 7,118.28 - -
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not
63 9.96 less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with - - - - - -
nuts and screws etc. complete:
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less
65 9.97 than grade AC 10 as per IS : 1868 ) transparent or dyed toreqired colour or shade with - - - - - -
necessary screws etc.
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than
67 9.100 grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with - - - - - -
necessary screws etc. complete :
Digitally signed by
ISTPage 56 of 103
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic
69 9.101 coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or - - - - - -
shade with necessary screws etc. complete:
71 9.79 Providing & fixing special quality bright finished brass Cupboard or ward robe locks with four - - - - - -
levers including necessary screws etc. complete (best make of approved quality).
Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters,
including fixing with necessary screws etc. complete.
75 9.114.2 Double strip (horizontal type) Each 8 39.7 41.3 - - 330.66 - -
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss /
76 9.127 matt / suede finish with high density protective surface layer and reverse side of adhesive - - -
bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved
Providing and fixing factory made uPVC glazed/wire mesh windows/comprising of lead free
uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded
profiles having minimum wall thickness of 1.7 mm for series R1 and R2 profiles and 2.1 mm
for series R3 and R4 profiles confirming to EN:12608 in any shape, colure and design duly
reinforced with galvanized mild steel section made of required shape & size as per CPWD
Speifications ,upvc extructed glazing beads ,interlocks and inline sash adaptor (where ever
required ) of appropriate dimension ,EPDM gasket, stainless steel SS 304 grade fastners of
minimum 8 mm dia with countersunk head ,comprising of matching polymade PA6 grade
78 9.147A sleeve for fixing frame to finishing wall as per IS 1367 : Part 1 to 14 coated) casement - - -
handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers,
plastic caps and necessary stainless steel screws etc. Profile of frame & sash mullion ( if
required ) shall be mitred cut and fusion welded /mechanically jointed duly sealed at all
corners, including drilling of holes for fixing hardware's and drainage of water etc. After
fixing frame the gap between frame and adjacent finished wall shall be filled with weather
proof silicon sealant over backer rod of required size and of approved quality, all complete
as per approved drawing comprising to CPWD Specification & direction of Engineer-in-
Charge. section of steel reinforcement and cross section of UPVC Profile to be as per design
approved by Engineer-in-Charge.
Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high
79 performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 - - -
shall be paid separately
Note:- Structural design proof checked from a Government Engineering Institute, to be
provided by the manufacturer for
81 (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 - - -
82 (ii) Sites with structure height more than 20m for all wind speeds - - -
Using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm & above)
83 9.147.A1.3 x (55 mm & above) with zinc alloy (zamak) powder coated handle on every panel along with Sqm 20.25 9628.6 10,024.4 - 2,02,994.74
multi-point locking system (Height above 1.8m)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats,
square or round bars etc. including priming coat withapproved steel primer all complete.
85 9.48.1 Fixed to steel window by welding kg 162.00 219.1 228.1 - - 36,953.37 - -
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC
polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood
powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for
100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with
86 26.86 full body threaded star headed SS screws having minimum frame density of 750 kg/cum, - - - - -
screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive
strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame
of Class A category with property of being termite/borer proof, water/moisture proof and fire
retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and
length complete as per direction of Engineer -In- Charge. (M.S hold fast/lugs or SS dash
fasteners shall be paid for separately).
87 Note: For WPC solid door/window frames, minus 5 mm tolerance in profile dimensions on - - - - -
plus side shall be acceptable but no extra payment on this account shall be made
Digitally signed by
ISTPage 57 of 103
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
board one side white color and other side of board laminited with pvc foil of minium 14
micron thickness of approved design pasted with hot melt adhesive for cup boards,work
station and bathroom /kitchen cabinet etc.of required sizes comprising of virgin polymer of K
(value 58-60 (suspension grade ), calcium carbonate and natural fibers (wood powder/ rice
husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)
89 26.89 having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & - - - - -
900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2
and resistance to spread of flame of Class A category with property of being termite/borer
proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges
/soft close clip on concealed hinges of required size with necessary full body threaded star
headed counter sunk S.S screws, all as per direction of Engineer -In- Charge. (Note: stainless
steel piano hinges/soft clip on concealed hinges and necessary S.S screws shall be paid
91 NS-18 Providing and fixing Magic eye with all respect complete. Each 1.00 - - 164.45 - - 164.45
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from
commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead
and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60
93 10.14 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. - - - - - -
pressed butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers
as specified and applying a coat of approved steel primer after pre-treatment of the surface
as directed by Engineer-in-charge:
94 10.14.3.1 Fixing with adjustable lugs with split end tail to each jamb (Profile E) metre 5 640.20 666.52 - - 3,332.59 - -
95 10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb (Profile B) metre 5 583.30 607.28 - - 3,036.40 - -
96 10.14.2.1 Fixing with adjustable lugs with split end tail to each jamb (Profile C) metre 5 611.75 636.90 - - 3,184.50 - -
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of
internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface
97 10.18 hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by Each 6 220.65 229.72 - - 1,378.33 - -
means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of
12 mm dia M.S. bar bent to shape as per standard drawing.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels,
plates etc., including welding, grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c
fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel
98 10.28 bolts etc., of required size, on the top of the floor or the side of waist slab with suitable Kg 144.00 772.40 804.15 - - 1,15,798.08 - -
arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of
stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat
15x3 mm and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both
Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS: 15622, of approved brand & manufacturer, in all colours
and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse
102 11.41A sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the - - - - - -
joints with white cement and matching pigments etc. The tiles must be cut
with the zero chipping diamond cutter only . Laying of tiles will be done
with the notch trowel, plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently and easily.
103 11.41A.1 Double charge vitrified tile polished finish of size - - - - - -
105 11.46.2 Size of Tile 600 x 600 mm sqm sqm - - -
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make,
106 11.38 in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed sqm 1,369.37 - 19,718.96 -
of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3
kg/ sq.m including pointing the joints with white cement and matching pigments etc.,
complete. 14.40 1315.3
Providing and laying Ceramic glazed Wall tiles of size 600x300 mm (thickness to be specified
by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all
107 NS-56 colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of sqm 103.32 - - 1,453.49 1,50,174.53
cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/
sq.m including pointing the joints with white cement and matching pigments etc., complete.
Digitally signed by
ISTPage 58 of 103
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
Providing and laying Polished Granite stone flooring in required design and patterns, in linear
as well as curvilinear portions of the building all complete as per the architectural drawings
with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1
cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement
slurry admixed with pigment of matching shade including rubbing , curing and polishing etc.
all complete as specified and as directed by the Engineer-in-Charge
109 11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red sqm 96.73 3071.05 3,197.30 - - 3,09,267.88 - -
Providing and fixing 1 mm galvalume roof sheet AZ-150 ,660 MPA including ridge, flashing
111 NS-1 over lapping etc complete plan area should be measured nothing extra shall be paid for sqm 200.00 - - 598.01 - - 1,19,601.42
lap, profile. ( valley creast etc)
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm Painting top of
roofs with bitumen of approved quality @ 17kg per 10 sqm
112 12.15 impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab sqm - - - - -
surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete
113 12.15.1 With residual type petroleum bitumen of grade VG -10 sqm 150 166.2 173.032 - 25,954.87 - -
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc.,
114 10.16 including cutting, hoisting, fixing in position and applying a priming coat of approved steel - - - - -
primer, including welding and bolted with special shaped washers etc. complete.
115 10.16.1 Hot finished welded type tubes kg 165.00 194.4 202.39 - 33,394.64 - -
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter
and weighing not less than 440 grams.
117 13.0 FINISHING WORK - - - - -
118 13.4 12 mm cement plaster of mix : - - - - -
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement :
120 13.11 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine Sqm 240 518.55 539.87 - 1,29,568.22 - -
121 13.16 6 mm cement plaster to ceiling of mix : - - - - -
Distempering with1st quality acrylic distemper (ready mixed) having VOC content less then
123 13.41 50 gram/litre of approved manufacture and of required shade and colour complete to - - - - -
achieve even shade and colour.
124 13.41.1 New work (two or more coats) over and including water tinnable priming coat with cement Sqm. 185.65 193.28 - - - -
primer having VOC content less then 50 gram/litre .
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre
125 13.48A and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior - - - - -
paint of required shade (Company Depot Tinted) with silicon additives
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat
of exterior primer applied @ 0.90 litre/10 sqm.
127 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour - - - - -
to give an even shade :
128 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of sqm 54 226.25 235.55 - 12,719.76 - -
approved brand and manufacture
Providing and applying white cement based putty of average thickness 1 mm, of approved
brand and manufacturer, over the plastered wall surface to prepare the surface even and
smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having
130 13.83 VOC (Volatile Organic Compound ) content less than 50 grams/ litre of - - - - -
approved brand and manufacture, including applying additional coats
wherever required to achieve even shade and colour.
132 21.0 ALUMINIUM WORK - - - - -
Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required
dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and
133 21.1 sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, - - - - -
rust free, straight, mitred and jointed mechanically wherever required including cleat angle,
Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for separately) :
134 21.1.1 For fixed portion - - - - -
Anodised aluminium (anodised transparent or
135 21.1.1.1 dyed to required shade according to IS: 1868, Kg 495.05 515.40 - - - -
Minimum anodic coating of grade AC 15)
Digitally signed by
ISTPage 59 of 103
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots
136 21.1.2 and making provision for fixing of fittings wherever required including the cost of EPDM - - - - -
rubber / neoprene gasket required (Fittings shall be paid for separately)
Anodised aluminium (anodised transparent or
137 21.1.2.1 dyed to required shade according to IS: 1868, Kg 598.60 623.21 - - - -
Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions
138 21.3 etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings - - - - -
and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in
139 21.3.2 With float glass panes of 5.0 mm thickness(wt not less then 12.5 kg/sqm) sqm 20.00 1505.25 1,567.13 - 31,342.62 - -
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing
weather silicon sealant over backer rod of approved quality as per architectural drawings
140 21.8 and direction of Engineer-in-charge complete. - - - - -
142 WATER PROOFING - - - - -
Providing and laying water proofing treatment in sunken portion of WCs, bathrooms etc. by
applying cement slurry mixed with water proofing cement comopund consisting of applying:
a) First layer of slurry of cement @ 0.488 kg./Sqm mixed with water proofing cement
143 22.5 comound @ 0.253 kg./Sqm. This layer will be allowed to air cure for 4 hours. b) Second Sqm 20 617.05 642.42 - 12,848.34 - -
layer of slurry of cement @ 0.242 kg./Sqm mixed with water proofing cement comopund @
0.126 kg./Sqm. This layer will be allowed to air cure for 4 hours followed with water curing
for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints,
corners, junctions of pipes and masonary with polymer mixed slurry.
Providing and laying in situ five course water proofing treatment with APP (Atactic
Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen
primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which
shall onsist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of
roofing membrane APP modified Polymeric membrane .0 mm thick of 3.00 Kg/ sqm weight
144 14.87 consisting of five layers prefabricated with centre core as 100 micron HMHDPE film Sqm 20 532.05 553.92 - 11,078.45 - -
sandwiched on both sides with polymeric mix and the polymeric mix is protected on both
side with 20 micron HMHDPE film. 5th, the top most layer shall be finished with brick tiles of
class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with
2% integral water proofing compound by weight of cement over a 12 mm layer of cement
mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid
for separately).
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI
(solar refractive index) > 78, solar reflection > 0.70 and initial emittance> 0.75 on
waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the
145 12.55 ratio of 1 :4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & Sqm 20 1703.95 1,774.00 - 35,479.99 - -
marble powder in ratio of 1 :1, including rubbing and polishing of the surface upto 3 cuts
complete, including providing skirting upto 150 mm height along the parapet walls in the
146 26.0 NEW TECHNOLOGIES AND MATERIALS - - - - -
Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595mm of approved texture, design and patterns
as per CPWD Specification 2019, to be laid in true horizontal level
suspended on inter-locking metal T-Grid of hot dipped galvanised
iron section of 0.33mmthick (galvanized @ 120 grams per sqm
including both sides)comprising of main-T runners of size 24x38
mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T of size 24x32 mm
of length 600mm to formgrid module of size 600 x 600 mm,
147 26.22 suspended from ceiling usinggalvanised mild steel items (galvanizing - - - - -
@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level
adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require,
fixed with Glavanised iron perimeter wall angle or size 24x24x0.40
mm of length 3000 mm to be fixed on periphey wall / partition with
the help of plastic rawl plugs at 450mm center to center and 40 mm
long dry wall S.S screws. The workshall be carried out as per
specifications,
Digitally signed by
ISTPage 60 of 103
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595mm of approved texture, design and patterns
as per CPWD Specification 2019, to be laid in true horizontal level
suspended on inter-locking metal T-Grid of hot dipped galvanised
iron section of 0.33mmthick (galvanized @ 120 grams per sqm
including both sides)comprising of main-T runners of size 24x38
mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T of size 24x32 mm
of length 600mm to formgrid module of size 600 x 600 mm,
148 26.22.1 suspended from ceiling usinggalvanised mild steel items (galvanizing sqm 19.20 2207 2,297.73 - 44,116.41 - -
@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level
adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require,
fixed with Glavanised iron perimeter wall angle or size 24x24x0.40
mm of length 3000 mm to be fixed on periphey wall / partition with
the help of plastic rawl plugs at 450mm center to center and 40 mm
long dry wall S.S screws. The workshall be carried out as per
specifications, - With 15 mm thick Tegular edged light weight calcium sliciate false ceiling
149 17.0 SANITARY INSTALLATIONS - - - - -
Note:-1. All Sanitarty fixture shal be low flow as mentioned below , where flow/ flush rate of
fixture shall be equivalent or lesser at 3 bar pressure( lpm/lpf) .
151 2. water closet flushing cistern (dual flush 3/6) urinals 2 lpm faucets (lavatory - - - - -
,pantry,health) 6 lpm.
152 3.multiple sprinkler system native trees & vegetation shall be used. - - - - -
4.over flow rain water storage & reuse on site of at least 75% of total building water
demand of 2 days shall be provide .
154 5. Desalting & grease trap system along with the proper flitation for rain water recharging - - - - -
shall be provided.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand
cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with
155 17.1.1 manually controlled device (handle lever) conforming to IS : 7231, with all fittings and Each 1 6,767.40 7,045.61 - 7,046 - -
fixtures complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot
Providing white vitreous china wall hung type European W.C. pan with white plastic seat and
156 NS-2 lid with C.P. brass hinges & rubber buffers, 3/6 liters dual flush type white vitreous china low Each 3 - - 17,916.68 - - 53,750.04
level flushing cistern fixed directly on W.C. pan with fittings and brackets complete.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P.
157 17.7 brass waste of standard pattern, including painting of fittings and brackets, cutting and - - - - -
making good the walls wherever require :
White Vitreous China Wash basin size 630x450 mm with a
single 15 mm C.P. brass pillar tap
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I.
159 17.10 brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting - - - - -
and making good the walls wherever required :
160 17.10.1 Kitchen sink with drain board - - - - -
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per
the direction of Engineer-in-charge.
163 17.28 Providing & fixing PVC waste pipe for sink or wash basin including PVC waste fittings - - - - -
164 17.28.1 Semi rigid pipe - - - - -
Providing and fixing 15mm C.P brass Sink Mixer for kitchen sink with swinging spout
complete. Including cutting and making good the walls wherever required .
167 Providing and Fixing of C.P. Brass Shower set comprising of : - - - - -
168 One No. CP brass Single Lever Concealed Diverter . - - - - -
169 One No. CP brass OH shower head & Shower Arm . - - - - -
170 One No. CP brass Bath Spout. - - - - -
171 Including cutting and making good the walls wherever required. - - - - -
172 NS-4 Shower set as described above. Set 4 - - 6,284.61 - - 25,138.45
Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved
173 17.31 quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP brass Each 4 1607.95 1,674.05 - 6,696.21 - -
screws and washers complete.
174 17.34 Providing and fixing toilet paper holder : - - - - -
Digitally signed by
ISTPage 61 of 103
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
Providing and fixing PTMT towel rail complete with brackets fixed to
176 17.73 wooden cleats with CP brass screws with concealed fittings arrangement of approved quality - - - - -
177 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 Each 4 708.95 738.09 - 2,952.38 - -
mm, weighing not less than 190 gms
Providing and fixing health faucet with 1 m long flexible tube and wall hook including all
fittings approved quality.
179 18.49 Providing & fixing CP brass bib cock of approved quality conforming IS 8931: - - - - -
181 18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS - - - - -
standards and weighing not less than 690 gms.
Providing and fixing CP brass angle valve for basin mixer and geyser points of approved
quality confirming IS: 8931:
185 WATER SUPPLY - - - - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for
hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing
186 18.7 the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one - - - - -
step CPVC solvent cement and testing of joints complete as per direction of Engineer in
187 Internal work - Exposed on wall - - - - -
188 18.7.1 15 mm nominal outer dia Pipes Metre 30 286.80 298.59 - 8,957.71 - -
189 18.7.2 20 mm nominal outer dia Pipes Metre 60 335.00 348.77 - 20,926.31 - -
190 18.7.3 25 mm nominal outer dia Pipes Metre 50 401.55 418.06 - 20,902.89 - -
191 18.7.4 32 mm nominal outer dia Pipes Metre 40 518.75 540.08 - 21,603.03 - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for
hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe
192 18.8 with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC - - - - -
solvent cement and the cost of cutting chases and making good the same including testing
of joints complete as per direction of Engineer in Charge.
193 Concealed work, including cutting chases and making good the walls etc. - - - - -
194 18.8.1 15 mm nominal outer dia Pipes Metre 40 497.80 518.26 - 20,730.58 - -
195 18.8.2 20 mm nominal outer dia Pipes Metre 40 537.60 559.70 - 22,388.03 - -
196 18.8.3 25 mm nominal outer dia Pipes Metre 40 627.25 653.04 - 26,121.45 - -
197 18.8.4 32 mm nominal outer dia Pipes Metre 40 739.30 769.69 - 30,787.70 - -
Providing and placing on terrace (at all floor levels) polythene water storage tank of
198 18.48 approved brand and manufacture with cover and suitable locking arrangement and making Litre 2000 11.00 11.45 - 22,904.42 - -
necessary holes for inlet , outlet and overflow pipes but without fittings and the base support
199 INTERNAL DRAINAGE - - - - -
200 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter Each 8.00 54.70 56.95 - 455.59 - -
and weighing not less than 440 grams.
Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6
Kg/ Sq cm rating with fitting for waste pipe from fixtures to floor trap including reduces,
201 NS-7 enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by - - - - -
clamp & hangers etc. The work includes cutting holes in wall/ floors/ slabs and making good
the same with cement concrete 1:2:4 complete as required.
Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all
209 NS-8-1 S-Trap type Floor Trap 110 x 110 mm (Long type-50 mm seal) Each 4.00 - - 777.41 - - 3,109.64
210 NS-8-2 P-Trap type Floor Trap 110 x 110 mm (Long type - 50 mm seal) Each 4.00 - - 451.83 - - 1,807.31
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement
211 19.1 mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. - - - - -
213 EXTERNAL SEWEGE SYSTEM - - - - -
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
214 2.8 foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including - - - - -
dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Digitally signed by
ISTPage 62 of 103
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
Excavating trenches of required width for pipes, cables, etc including excavation for sockets,
and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the
216 2.10 excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in - - - - -
depth, including consolidating each deposited layer by ramming, watering, etc. and disposing
of surplus excavated soil as directed, within a lead of 50 m :
217 2.10.1 All kinds of soil. - - - - -
218 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia Metre 100 352.15 366.63 - 36,662.69 - -
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating
brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside)
the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per
standard design:
221 19.4.3.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 8 2802.15 2,917.35 - 23,338.77 - -
Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse sand)
with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate
20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded
stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar
222 19.7 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making - - -
channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20
mm nominal size) finishd with a floating coat of neat cement complete as per standard
Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x
223 19.7.1 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg (weight - - -
of cover 23 kg and weight of frame 15 kg)
224 19.7.1.1 With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5 each 2.00 12,770.55 13,295.55 - 26,591.09
225 19.8 Extra for depth for manholes : - - - - -
227 19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 1 8825.40 9,188.21 - 9,188.21 - -
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor
231 1.11 single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, Point 18.00 - 1562 1,682 - 30,275.37 -
modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated
copper conductor single core cable etc as required.
Wiring for light/power plug with 2x4 Sq.mm FRLS PVC insulated, copper conductor, single
232 1.12 core cable in surface/recessed PVC conduit alongwith 1 No. 4 Sq.mm FRLS PVC insulated Metre 200.00 - 334 360 - 71,930.39 -
copper conductor single core cable for loop earthing as required.
Wiring for light/power plug with 4x4 Sq.mm FRLS PVC insulated, copper conductor, single
233 1.13 core cable in surface/recessed PVC conduit alongwith 2 Nos. 4 Sq.mm FRLS PVC insulated Metre 120.00 - 537 578 - 69,389.13 -
copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC
234 1.14 insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit - - - - -
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in
240 1.21 surface/recess including cutting the wall and making good the same in case of recessed - - - - -
conduit as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate
switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box
excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate
for modular switches in recess etc as required.
Digitally signed by
ISTPage 63 of 103
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or
249 1.32 in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and Each 10.00 - 586 631 - 6,310.06 -
15/16 amps modular switch, connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent
fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall,
including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core
cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single
core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc.
Installation of exhaust fan in the existing opening, including making good the damage,
connection, testing, commissioning etc. as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with
G.I. fittings including trenching (75 cm deep)and re-filling etc. as required
Digitally signed by
ISTPage 64 of 103
DSR-2023 Amount (DSR- Amount (DSR
Rate- E/M Rate
Rate (incl. CF DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF Rate -NS NS AMOUNT
0.973 + CI E/M Rate with correction 6.33%) E/M with
7%) factor correction factor
Supplying and fixing following way, single pole and neutral, sheet steel ,MCB distribution
257 2.3 board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral bus bar, - - - - -
earth bar, din bar, interconnections powder painted including earthing etc. as required. (But
with out MCB/RCCB/ Isolator).
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel ,MCB
259 2.4 distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, - - - - -
neutral bus bar, earth bar, din bar, interconnections powder painted including earthing etc.
as required. (But with out MCB/RCCB/ Isolator).
supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C Curve, miniature circuit breaker
261 2.10 suitable for inductive load of following poles in the existing MCB DB complete with - - - - -
connectoin testing and commissioning etc.as required.
263 2.12 supplying and fixing following rating,double pole,240 V,isolator in the existing MCB DB - - - - -
complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,four pole,415 V,isolator in the existing MCB DB
complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,double pole,240 V,residual current circuit breaker
267 2.14 (RCCB),having a sensitivity currrent 30 mA in the eiting MCB DB completed with connection - - - - -
,teting commisoining etc.as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth
electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as
required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring
washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with
existing surface/ recessed conduit/ submain wiring/ cable as required.
272 FITTING & FIXTURES - - - - -
Supply, Installation, Testing & Commissioning of recessed type down lighter complete with
273 NS-11 lamps & accessories 18 W Philips Model No:DN296B LED 20S-6500 PSE WH S2/ Havells Each 10.00 - - 1,470.79 - - 14,707.93
Model: INTEGRANEODLR18WLED865S or equivalent
Supply, Installation, Testing & Commissioning of recess type 2x2, 36watt LED Light Fixtures
274 NS-12 complete with lamps & accessories.Philips Model No:RC380B LED 36S/ Havells Model: Each 4.00 - - 7,295.13 - - 29,180.53
VENUSNEO2X2PLR36WLED865G2 or equivalent
Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling
fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm
long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factornot
less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min ,
350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic
regulator unit for speed control and all remaining accessories including safety pin, nut
bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2
mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as
Supplying of approved make Exaust Fan of the following size and its all accessories suitable
276 NS-13 for operation on 230V single phase, 50 Hz, AC supply complete as required.-250 mm Each - - 2,432.76 - - -
Providing and fixing GRC Jali 40 mm thick as per required opening size & all heights with all
complete as per direction Engineer In Charge.
Supplying Installation, testing and commissioning Electric Chimney with all complete as per
direction Engineer In Charge.
Supplying Installation, testing and commissioning of 25 lt.Geyser with all complete as per
direction Engineer In Charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions
280 NS-14 etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings Sqm 20.0 - - 1637.60 32,751.96
and the directions of engineer-in-charge. (No extra Cost )-Laminated Clear Toughned glass -
281 NS-15 Providing and fixing Granite quadrant of 250 mm dia bathroom corner self with all respect Each 12 - - 415.28 4,983.39
Supply, Installation, Testing & Commissioning of flood light 80watt with all respect complete.
Providing and fixing Aluminium Ventilator Louvers with 5 mm thick glass with all respect
Digitally signed by
ISTPage 65 of 103
BOQ- Guest House
Name of Work:- Construction of Permanent Campus at JNV Nandurbar-I (Maharashtra)
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
1 2.0 EARTH WORK
2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
2 over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan)
including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth
to be levelled and neatly dressed.
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of
4 foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited cum 80.37 196.00 204.06 - - 16,400.57 - -
layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.27 Supplying and filling in plinth with sand under floors including watering, ramming
5 consolidating and dressing complete. Cum 10.13 2123.75 2,211.06 - - 22,386.96 - -
6 2.34 Supplying chemical emulsion in sealed containers including delivery as specified. - - - - - -
2.34.1 Chlorpyriphos/Lindane Emulsifiable concentrate of 20%.
2.35 Diluting and injecting chemical emulsion for Post - CONSTRUCTIONAL anti-termite
8 treatment (excluding the cost of chemical emulsion) - - - - - -
Along external wall where the apron is not provided using chemical emulsion @ 7.5
9 2.35.1 litres / sqm of the vertical surface of the substructure to a depth of 300mm including - - - - -
excavation channel along the wall & rodding etc. complete:
10 2.35.1.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration Metre 12.00 38.9 40.50 - 485.99 - -
2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole,
300 mm apart including drilling 12 mm dia holes and plugging with cement mortar 1:2
11 (1 cement :2 coarse sand ) to match the existing floor. - - - - - -
12 2.35.3.1 With Chlorpyriphos /Lindane E C. 20% with 1% concentration. Sqm 40.00 310.05 322.80 - - 12,911.85 - -
13 4.0 CONCRETE WORK - - - - - -
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of
cantering and shuttering - All work up to plinth level
15 4.1.8 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) cum 22.95 6812.00 7,092.04 - - 1,62,782.29 - -
4.1.10 1:5:10 (1 cement : 5 coarse sand(zone -III) derived from natural soueces : 10 graded
stone aggregate 40 mm nominal size Derived from natural soueces
4.10 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1
cement : 2 coarse sand(zone -III) derived from natural soueces : 4 graded stone
17 aggregate 12.5 mm nominal size derived from natural soueces. Sqm 18.40 410.85 427.74 - - 7,870.42 - -
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3
manufactured sand (zone-III) derived from natural sources : 6 graded stone aggregate
18 20 mm nominal size derived from natural sources over 75mm thick bed of dry brick Sqm 37.50 749.30 780.10 - - 29,253.89 - -
ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,
including necessary excavatin, levelling & dressing & finishing the top smooth.
20 5.9 Centring and shuttering including strutting, propping etc. and removal of form for: - - - - - -
21 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. sqm 44.78 392.15 408.27 - - 18,280.35 - -
22 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 85.00 927.25 965.37 - - 82,056.39 - -
23 5.9.5 Lintels, beams, plinth beams, girders, bressummers and cantilevers. Sqm 82.40 736.40 766.67 - - 63,173.89 - -
24 5.9.6 Columns, Pillars, Piers, Abutments, posts and Struts Sqm 90.34 961.30 1,000.82 - - 90,411.49 - -
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
5.22.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more.
5.22 A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
27 position and binding all complete above plinth level. - - - - - -
28 5.22A.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more. kg 1589.55 107.85 112.28 - - 1,78,481 - -
Digitally signed by
ISTPage 66 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
5.33 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade
for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to
29 site of laying , excluding the cost of cantering, shuttering finishing and reinforcement, - - - - - -
including cost of admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately).
30 All works upto plinth level - - - - - -
31 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 22.35 9504.75 9,895.49 - - 2,21,122 - -
32 All works above plinth level upto floor V level - - - - - -
33 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 15.90 9860.40 10,265.76 - - 1,63,180 - -
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5
6.1 in foundation and plinth
36 6.1.2 Cement mortar 1:6 (1 cement: 6 coarse sand) Cum 8.28 7,132.25 7,425.46 - 61,483
6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third
course of half brick masonry.
6.32 Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in
superstructure above plinth level up to floor five level in :
6.45 Half brick masonry with non modular fly ash bricks of class designation 10, conforming
to IS: 12894, in superstructure above plinth up to floor V level.
42 8.0 CLADDING WORK - - - - - -
Providing and fixing 18mm thick gang saw cut mirror polished remoulded and
repolished) machine cut for kitchen platforms, vanity counters, window sills , facias and
similar locations of required size of approved shade, colour and texture laid over 20mm
43 8.2 thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white - - - - - -
cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc. complete at all levels.
44 8.2.3 Granite stone slab of all colourand texture expect black,Cherry/ Ruby Red - - - - - -
Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including
46 8.3 machine polishing to edge to give high gloss finish etc. complete as per design - - - - - -
approved by Engineer-in-Charge.
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia
48 8.4 and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning metre 10.00 568.55 591.92 - - 5,919 - -
Extra for providing opening of required size & shape for wash basins / kitchen sink in
49 8.5 kitchen platform, vanity counters and similar location in marble / Granite / stone work Each 4.00 978.70 1,018.93 - - 4,076 - -
including necessary holes for pillar taps etc. Including rubbing and polishing necessary
Providing wood work in frames of doors, windows, clerestory windows and other
51 9.1 frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners - - -
of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing 19 mm thick both side balancing laminationfactory pressed BWP
grade marine ply as per IS : 710 of approved brand
boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws
53 9.169 etc. complete as per direction of Engineer-incharge Sqm 33.84 2593.15 2,699.75 - - 91,359.69 - -
9.21 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)
54 non-decorative type, core of block board construction with frame of 1st class hard wood - - - - - -
and well matched commercial 3 ply veneering with vertical grains or cross bands and
face veneers on both faces of shutters :
55 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 10.08 2392.65 2,491.01 - - 25,109.40 - -
Digitally signed by
ISTPage 67 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on
all edges of flush door shutters (over all area of door shutter to be measured).
9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to be
9.76 Providing & fixing bright finished brass 100mm mortice latch and lock with 6 levers and
58 a pair of lever handles with necessary screws etc. complete (Best make of approved Each 10.08 854.65 889.78 - - 8,969.03 - -
9.96 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating
59 not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or - - - - - -
shade with nuts and screws etc. complete:
9.97 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less
61 than grade AC 10 as per IS : 1868 ) transparent or dyed toreqired colour or shade with - - - - - -
necessary screws etc.
9.100 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less
63 than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade - - - - - -
with necessary screws etc. complete :
9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic
65 coating not less than grade AC 10 as per IS :1868) transparent or dyed to required - - - - - -
colour or shade with necessary screws etc. complete:
9.79 Providing & fixing special quality bright finished brass Cupboard or ward robe locks with
67 four levers including necessary screws etc. complete (best make of approved quality). - - - - - -
9.91 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with
9.114 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe
shutters, including fixing with necessary screws etc. complete.
71 9.114.2 Double strip (horizontal type) Each 8 39.7 41.33 - - 330.66 - -
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in
gloss / matt / suede finish with high density protective surface layer and reverse side of
72 9.127 adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of - - -
approved quality.
9.147A Providing and fixing factory made uPVC glazed/wire mesh windows/comprising of lead
free uPVC multi-chambered frame, sash and mullion/coupler (where ever required)
extruded profiles having minimum wall thickness of 1.7 mm for series R1 and R2
profiles and 2.1 mm for series R3 and R4 profiles confirming to EN:12608 in any shape,
colure and design duly reinforced with galvanized mild steel section made of required
shape & size as per CPWD Speifications ,upvc extructed glazing beads ,interlocks and
inline sash adaptor (where ever required ) of appropriate dimension ,EPDM gasket,
stainless steel SS 304 grade fastners of minimum 8 mm dia with countersunk head
,comprising of matching polymade PA6 grade sleeve for fixing frame to finishing wall as
74 per IS 1367 : Part 1 to 14 coated) casement handles, G.I fasteners 100 x 8 mm size - - -
for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless
steel screws etc. Profile of frame & sash mullion ( if required ) shall be mitred cut and
fusion welded /mechanically jointed duly sealed at all corners, including drilling of holes
for fixing hardware's and drainage of water etc. After fixing frame the gap between
frame and adjacent finished wall shall be filled with weather proof silicon sealant over
backer rod of required size and of approved quality, all complete as per approved
drawing comprising to CPWD Specification & direction of Engineer-in-Charge. section of
steel reinforcement and cross section of UPVC Profile to be as per design approved by
Engineer-in-Charge.
Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without
75 high performance coatings as per design requirements and conforming to IS: 3548 & - - -
IS: 16231 shall be paid separately
Note:- Structural design proof checked from a Government Engineering Institute, to be
provided by the manufacturer for
77 (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 - - -
78 (ii) Sites with structure height more than 20m for all wind speeds - - -
9.147.A1.3 Using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm &
79 above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every Sqm 12.00 9628.6 10,024.43 - 1,20,293.18
panel along with multi-point locking system (Height above 1.8m)
Digitally signed by
ISTPage 68 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
flats, square or round bars etc. including priming coat withapproved steel primer all
81 9.48.1 Fixed to steel window by welding kg 72.00 219.1 228.11 - - 16,423.72 - -
26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC
polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers
(wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index
of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and
screwed with full body threaded star headed SS screws having minimum frame density
82 of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum - - - - -
compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to
spread of flame of Class A category with property of being termite/borer proof,
water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS
dash fasteners of required dia and length complete as per direction of Engineer-In-
Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).
Note: For WPC solid door/window frames, minus 5 mm tolerance in profile dimensions
on plus side shall be acceptable but no extra payment on this account shall be made
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid
board one side white color and other side of board laminited with pvc foil of minium 14
micron thickness of approved design pasted with hot melt adhesive for cup boards,work
station and bathroom /kitchen cabinet etc.of required sizes comprising of virgin polymer
of K (value 58-60 (suspension grade ), calcium carbonate and natural fibers (wood
powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12
for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of
85 26.89 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of - - - - -
elasticity 850 N/mm2 and resistance to spread of flame of Class A category with
property of being termite/borer proof, water/moisture proof and fire retardant and
fixing with stainless steel piano hinges /soft close clip on concealed hinges of required
size with necessary full body threaded star headed counter sunk S.S screws, all as per
direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft clip on
concealed hinges and necessary S.S screws shall be paid separately).
87 NS-18 Providing and fixing Magic eye with all respect complete. Each 2.00 - - 164.45 - - 328.90
10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan
clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with
89 its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ Each 8 220.65 229.72 - - 1,837.77 - -
M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners.
Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels,
plates etc., including welding, grinding, buffing, polishing and making curvature
(wherever required) and fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories & stainless steel dash
90 fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side Kg 72.00 772.40 804.15 - - 57,899.04 - -
of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless steel members shall be considered excluding
fixing accessories such as nuts, bolts, fasteners
10.29 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with
M.S. Flat 15x3 mm and nuts & bolts complete.
10.29.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both
93 11.0 FLOORING WORK - - - - - -
Digitally signed by
ISTPage 69 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS: 15622, of approved brand & manufacturer, in all colours
and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse
94 sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the - - - - - -
joints with white cement and matching pigments etc. The tiles must be cut
with the zero chipping diamond cutter only . Laying of tiles will be done
with the notch trowel, plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently and easily.
95 11.41A.1 Double charge vitrified tile polished finish of size - - - - - -
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20
97 11.38 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey sqm 17.00 1315.3 1,369.37 - 23,279.32 -
cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and
matching pigments etc., complete.
Providing and laying Ceramic glazed Wall tiles of size 600x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20
98 NS-56 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey sqm 90.72 - - 1453.49 1,31,860.57
cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and
matching pigments etc., complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in
linear as well as curvilinear portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement
mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing
with white cement slurry admixed with pigment of matching shade including rubbing ,
curing and polishing etc. all complete as specified and as directed by the Engineer-in-
100 11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red sqm 108.20 3071.05 3,197.30 - - 3,45,948 - -
NS-1 Providing and fixing 1 mm galvalume roof sheet AZ-150 ,660 MPA including ridge,
102 flashing over lapping etc complete plan area should be measured nothing extra shall sqm 100.00 - - 598.01 - - 59,800.71
be paid for lap, profile. ( valley creast etc)
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm Painting top
of roofs with bitumen of approved quality @ 17kg per 10 sqm
103 12.15 impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the sqm - - - - -
slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil
104 12.15.1 With residual type petroleum bitumen of grade VG -10 sqm 100 166.2 173.03 - 17,303 - -
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses
etc., including cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer, including welding and bolted with special shaped washers etc.
106 10.16.1 Hot finished welded type tubes kg 792.00 194.4 202.39 - 1,60,294 - -
12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm
diameter and weighing not less than 440 grams.
108 13.0 FINISHING WORK - - - - -
109 13.4 12 mm cement plaster of mix : - - - - -
13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1
111 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 Sqm 200 518.55 539.87 - 1,07,974 - -
cement : 6 fine sand).
112 13.16 6 mm cement plaster to ceiling of mix : - - - - -
13.41 Distempering with1st quality acrylic distemper (ready mixed) having VOC content less
114 then 50 gram/litre of approved manufacture and of required shade and colour complete - - - - -
to achieve even shade and colour.
13.41.1 New work (two or more coats) over and including water tinnable priming coat with
cement primer having VOC content less then 50 gram/litre .
Digitally signed by
ISTPage 70 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50
116 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt - - - - -
resistance exterior paint of required shade (Company Depot Tinted) with silicon
13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming
coat of exterior primer applied @ 0.90 litre/10 sqm.
13.62 Painting with synthetic enamel paint of approved brand and manufacture of required
colour to give an even shade :
13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary
paint of approved brand and manufacture
13.80 Providing and applying white cement based putty of average thickness 1 mm, of
approved brand and manufacturer, over the plastered wall surface to prepare the
surface even and smooth complete.
13.83 Wall painting with premium acrylic emulsion paint of interior grade, having
121 VOC (Volatile Organic Compound ) content less than 50 grams/ litre of - - - - -
approved brand and manufacture, including applying additional coats
wherever required to achieve even shade and colour.
123 21.0 ALUMINIUM WORK - - - - -
21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections
of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of
required dia and size, including necessary filling up the gaps at junctions, i.e. at top,
124 bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections - - - - -
shall be smooth, rust free, straight, mitred and jointed mechanically wherever required
including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass /
stainless steel screws, all complete as per architectural drawings and the directions of
Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
125 21.1.1 For fixed portion - - - - -
21.1.1.1 Anodised aluminium (anodised transparent or
126 dyed to required shade according to IS: 1868, Kg 10.00 495.05 515.40 - 5,154 - -
Minimum anodic coating of grade AC 15)
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/
127 pivots and making provision for fixing of fittings wherever required including the cost of - - - - -
EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
21.1.2.1 Anodised aluminium (anodised transparent or
128 dyed to required shade according to IS: 1868, Kg 10.00 598.60 623.21 - 6,232 - -
Minimum anodic coating of grade AC 15)
21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and
129 partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the - - - - -
architectural drawings and the directions of engineer-in-charge. (Cost of aluminium
snap beading shall be paid in basic item):
130 21.3.2 With float glass panes of 5.0 mm thickness(wt not less then 12.5 kg/sqm) sqm 2.00 1505.25 1,567.13 - 3,134 - -
21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by
providing weather silicon sealant over backer rod of approved quality as per
131 architectural drawings and direction of Engineer-in-charge complete. - - - - -
132 21.8.1 Upto 5mm depth and 5 mm width Metre 12 96.75 100.73 - 1,209 - -
133 WATER PROOFING - - - - -
Providing and laying water proofing treatment in sunken portion of WCs, bathrooms etc.
by applying cement slurry mixed with water proofing cement comopund consisting of
applying: a) First layer of slurry of cement @ 0.488 kg./Sqm mixed with water proofing
cement comound @ 0.253 kg./Sqm. This layer will be allowed to air cure for 4 hours. b)
134 22.5 Second layer of slurry of cement @ 0.242 kg./Sqm mixed with water proofing cement Sqm 24.00 617.05 642.42 - 15,418 - -
comopund @ 0.126 kg./Sqm. This layer will be allowed to air cure for 4 hours followed
with water curing for 48 hours. The rate includes preparation of surface, treatment and
sealing of all joints, corners, junctions of pipes and masonary with polymer mixed
Digitally signed by
ISTPage 71 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
Providing and laying in situ five course water proofing treatment with APP (Atactic
Polypropylene) modified Polymeric memberane over roof consisting of first coat of
bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20
kg/sqm, which shall onsist of blown type bitumen of grade 85/25 conforming to IS :
702, 3rd layer of roofing membrane APP modified Polymeric membrane .0 mm thick of
135 14.87 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 Sqm 50.00 532.05 553.92 - 27,696 - -
micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric
mix is protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall
be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1
cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of
cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished
neat (item of laying brick tiles shall be paid for separately).
136 26.0 NEW TECHNOLOGIES AND MATERIALS - - - - -
26.22 Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595mm of approved texture, design and patterns
as per CPWD Specification 2019, to be laid in true horizontal level
suspended on inter-locking metal T-Grid of hot dipped galvanised
iron section of 0.33mmthick (galvanized @ 120 grams per sqm
including both sides)comprising of main-T runners of size 24x38
mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T of size 24x32 mm
of length 600mm to formgrid module of size 600 x 600 mm,
137 suspended from ceiling usinggalvanised mild steel items (galvanizing - - - - -
@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level
adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require,
fixed with Glavanised iron perimeter wall angle or size 24x24x0.40
mm of length 3000 mm to be fixed on periphey wall / partition with
the help of plastic rawl plugs at 450mm center to center and 40 mm
long dry wall S.S screws. The workshall be carried out as per
specifications,
26.22.1 Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595mm of approved texture, design and patterns
as per CPWD Specification 2019, to be laid in true horizontal level
suspended on inter-locking metal T-Grid of hot dipped galvanised
iron section of 0.33mmthick (galvanized @ 120 grams per sqm
including both sides)comprising of main-T runners of size 24x38
mm of length 3000 mm,cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T of size 24x32 mm
of length 600mm to formgrid module of size 600 x 600 mm,
138 suspended from ceiling usinggalvanised mild steel items (galvanizing sqm 17.00 2207 2,297.73 - 39,061 - -
@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level
adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to
pierce into 12x50mm or even bigger size dash fastener if require,
fixed with Glavanised iron perimeter wall angle or size 24x24x0.40
mm of length 3000 mm to be fixed on periphey wall / partition with
the help of plastic rawl plugs at 450mm center to center and 40 mm
long dry wall S.S screws. The workshall be carried out as per
specifications,- With 15 mm thick Tegular edged light weight calcium sliciate false ceiling
139 17.0 SANITARY INSTALLATIONS - - - - -
Note:-1. All Sanitarty fixture shal be low flow as mentioned below , where flow/ flush
rate of fixture shall be equivalent or lesser at 3 bar pressure( lpm/lpf) .
2. water closet flushing cistern (dual flush 3/6) urinals 2 lpm faucets (lavatory
,pantry,health) 6 lpm.
142 3.multiple sprinkler system native trees & vegetation shall be used. - - - - -
4.over flow rain water storage & reuse on site of at least 75% of total building water
143 demand of 2 days shall be provide . - - - - -
5. Desalting & grease trap system along with the proper flitation for rain water
recharging shall be provided.
Digitally signed by
ISTPage 72 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
17.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm
sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush
pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all
145 fittings and fixtures complete, including cutting and making good the walls and floors Each 2 6,767.40 7,045.61 - 14,091 - -
wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm
with integral type foot rests
NS-2 Providing white vitreous china wall hung type European W.C. pan with white plastic seat
146 and lid with C.P. brass hinges & rubber buffers, 3/6 liters dual flush type white vitreous Each 2 - - 17,916.68 - - 35,833.36
china low level flushing cistern fixed directly on W.C. pan with fittings and brackets
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm
147 C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting - - - - -
and making good the walls wherever require :
17.7.2 White Vitreous China Wash basin size 630x450 mm with a
single 15 mm C.P. brass pillar tap
17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with
149 C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, - - - - -
cutting and making good the walls wherever required :
150 17.10.1 Kitchen sink with drain board - - - - -
17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as
per the direction of Engineer-in-charge.
17.28 Providing & fixing PVC waste pipe for sink or wash basin including PVC waste fittings
154 17.28.1 Semi rigid pipe - - - - -
Providing and fixing 15mm C.P brass Sink Mixer for kitchen sink with swinging spout
complete. Including cutting and making good the walls wherever required .
157 Providing and Fixing of C.P. Brass Shower set comprising of : - - - - -
158 One No. CP brass Single Lever Concealed Diverter . - - - - -
159 One No. CP brass OH shower head & Shower Arm . - - - - -
160 One No. CP brass Bath Spout. - - - - -
161 Including cutting and making good the walls wherever required. - - - - -
162 NS-4 Shower set as described above. Set 4 - - 6,284.61 - - 25,138.45
17.31 Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved
163 quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP Each 4 1607.95 1,674.05 - 6,696 - -
brass screws and washers complete.
164 17.34 Providing and fixing toilet paper holder : - - - - -
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to
166 wooden cleats with CP brass screws with concealed fittings arrangement of approved - - - - -
quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height
of 88 mm, weighing not less than 190 gms
Providing and fixing health faucet with 1 m long flexible tube and wall hook including all
fittings approved quality.
169 18.49 Providing & fixing CP brass bib cock of approved quality conforming IS 8931: - - - - -
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS
standards and weighing not less than 690 gms.
Providing and fixing CP brass angle valve for basin mixer and geyser points of approved
quality confirming IS: 8931:
175 WATER SUPPLY - - - - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
176 18.7 including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & - - - - -
fittings with one step CPVC solvent cement and testing of joints complete as per
direction of Engineer in Charge.
177 Internal work - Exposed on wall - - - - -
178 18.7.1 15 mm nominal outer dia Pipes Metre 6 286.80 298.59 - 1,792 - -
179 18.7.2 20 mm nominal outer dia Pipes Metre 6 335.00 348.77 - 2,093 - -
180 18.7.3 25 mm nominal outer dia Pipes Metre 6 401.55 418.06 - 2,508 - -
181 18.7.4 32 mm nominal outer dia Pipes Metre 6 518.75 540.08 - 3,240 - -
Digitally signed by
ISTPage 73 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
182 18.8 i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & - - - - -
fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in
183 Concealed work, including cutting chases and making good the walls etc. - - - - -
184 18.8.1 15 mm nominal outer dia Pipes Metre 6 497.80 518.26 - 3,110 - -
185 18.8.2 20 mm nominal outer dia Pipes Metre 6 537.60 559.70 - 3,358 - -
186 18.8.3 25 mm nominal outer dia Pipes Metre 6 627.25 653.04 - 3,918 - -
187 18.8.4 32 mm nominal outer dia Pipes Metre 6 739.30 769.69 - 4,618 - -
Providing and placing on terrace (at all floor levels) polythene water storage tank of
188 18.48 approved brand and manufacture with cover and suitable locking arrangement and Litre 1000 11.00 11.45 - 11,452 - -
making necessary holes for inlet , outlet and overflow pipes but without fittings and the
base support for tank.
189 INTERNAL DRAINAGE - - - - -
12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm
diameter and weighing not less than 440 grams.
Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of
min 6 Kg/ Sq cm rating with fitting for waste pipe from fixtures to floor trap including
191 NS-7 reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level - - - - -
supported by clamp & hangers etc. The work includes cutting holes in wall/ floors/ slabs
and making good the same with cement concrete 1:2:4 complete as required.
Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all
199 NS-8-1 S-Trap type Floor Trap 110 x 110 mm (Long type-50 mm seal) Each 2.00 - - 777.41 - - 1,554.82
200 NS-8-2 P-Trap type Floor Trap 110 x 110 mm (Long type - 50 mm seal) Each 2.00 - - 451.83 - - 903.66
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of
201 19.1 cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of - - - - -
joints etc. complete :
203 EXTERNAL SEWEGE SYSTEM - - - - -
2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
204 including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting - - - - -
out the excavated soil and disposal of surplus excavated soil as directed, within a lead
2.10 Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting
206 out the excavated soil, and then returning the soil as required, in layers not exceeding - - - - -
20 cm in depth, including consolidating each deposited layer by ramming, watering, etc.
and disposing of surplus excavated soil as directed, within a lead of 50 m :
207 2.10.1 All kinds of soil. - - - - -
208 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia Metre 12 352.15 366.63 - 4,400 - -
19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating
brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size
(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design:
211 19.4.3.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 2 2802.15 2,917.35 - 5,835 - -
Digitally signed by
ISTPage 74 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
19.7 Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse
sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone
aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick
with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat
cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4
graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat
cement complete as per standard design
19.7.1 Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x
213 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg - - -
(weight of cover 23 kg and weight of frame 15 kg)
214 19.7.1.1 With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5 each 2.00 12,770.55 13,295.55 - 26,591
215 19.8 Extra for depth for manholes : - - - - -
217 19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 2 8825.40 9,188.21 - 18,376 - -
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable in surface / recessed medium class
219 1.10 PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point - - - - -
with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable in surface / recessed medium class PVC conduit, 2 way modular
221 1.11 switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC Point 5.00 - 1562 1,681.97 - 8,409.83 -
insulated copper conductor single core cable etc as required.
Wiring for light/power plug with 2x4 Sq.mm FRLS PVC insulated, copper conductor,
single core cable in surface/recessed PVC conduit alongwith 1 No. 4 Sq.mm FRLS PVC
222 1.12 insulated copper conductor single core cable for loop earthing as required. Metre 10.00 - 334 359.65 - 3,596.52 -
Wiring for light/power plug with 4x4 Sq.mm FRLS PVC insulated, copper conductor,
223 1.13 single core cable in surface/recessed PVC conduit alongwith 2 Nos. 4 Sq.mm FRLS PVC Metre 10.00 - 537 578.24 - 5,782.43 -
insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS
224 1.14 PVC insulated copper conductor, single core cable in surface/ recessed medium class - - - - -
PVC conduit as required
Supplying and fixing of following sizes of medium class PVC conduit along with
230 1.21 accessories in surface/recess including cutting the wall and making good the same in - - - - -
case of recessed conduit as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate
switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box
excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover
plate for modular switches in recess etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on
239 1.32 surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular Each 10.00 - 586 631.01 - 6,310.06 -
socket outlet and 15/16 amps modular switch, connection etc. as required.
Digitally signed by
ISTPage 75 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact
fluorescent fitting of all types, complete with all accessories and tube etc. directly on
ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor,
single core cable, including providing and fixing phenolic laminated sheet cover on the
fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage,
connection, testing, commissioning etc. as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete
with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel ,MCB distribution
247 2.3 board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral bus - - - - -
bar, earth bar, din bar, interconnections powder painted including earthing etc. as
required. (But with out MCB/RCCB/ Isolator).
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel
249 2.4 ,MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper - - - - -
busbar, neutral bus bar, earth bar, din bar, interconnections powder painted including
earthing etc. as required. (But with out MCB/RCCB/ Isolator).
supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C Curve, miniature circuit
251 2.10 breaker suitable for inductive load of following poles in the existing MCB DB complete - - - - -
with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,double pole,240 V,isolator in the existing MCB DB
complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,four pole,415 V,isolator in the existing MCB DB
complete with connectoin testing and commissioning etc.as required.
supplying and fixing following rating,double pole,240 V,residual current circuit breaker
257 2.14 (RCCB),having a sensitivity currrent 30 mA in the eiting MCB DB completed with - - - - -
connection ,teting commisoining etc.as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip
earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer
etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt
& spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along
with existing surface/ recessed conduit/ submain wiring/ cable as required.
262 FITTING & FIXTURES - - - - -
Supply, Installation, Testing & Commissioning of recessed type down lighter complete
263 NS-11 with lamps & accessories 18 W Philips Model No:DN296B LED 20S-6500 PSE WH S2/ Each 4.00 - - 1,470.79 - - 5,883.17
Havells Model: INTEGRANEODLR18WLED865S or equivalent
Supply, Installation, Testing & Commissioning of recess type 2x2, 36watt LED Light
Fixtures complete with lamps & accessories.Philips Model No:RC380B LED 36S/ Havells
Model: VENUSNEO2X2PLR36WLED865G2 or equivalent
Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated,
ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos.
blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding,
Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery
minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%,
remote or electronic regulator unit for speed control and all remaining accessories
including safety pin, nut bolts,washers, temperature rise=75 degree C (max.),
insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC
Supply, earthing etc. complete as required.
Digitally signed by
ISTPage 76 of 103
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
DSR 2022 2023) Civil 2022+GST
S.N. DSR -2023 DESCRIPTION OF ITEM UNIT Qty DSR.2023 (incl. CF 0.973 + (incl. CF Rate -NS NS AMOUNT
E/M Rate with correction 6.33%) E/M with
factor correction factor
Supplying of approved make Exaust Fan of the following size and its all accessories
suitable for operation on 230V single phase, 50 Hz, AC supply complete as required.-
Providing and fixing GRC Jali 40 mm thick as per required opening size & all heights
267 NS-53 with all complete as per direction Engineer In Charge. Sqm 4 - - 4,747.38 18,989.52
Supplying Installation, testing and commissioning of 25 lt.Geyser with all complete as
268 NS-55 per direction Engineer In Charge. Each 4 - - 8,637.33 34,549.33
Providing and fixing glazing in aluminium door, window, ventilator shutters and
269 NS-14 partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the Sqm - - 1637.6 4,912.79
architectural drawings and the directions of engineer-in-charge. (No extra Cost )-
Laminated Clear Toughned glass -6 mm 3
Providing and fixing Granite quadrant of 250 mm dia bathroom corner self with all
respect complete 8
Supply, Installation, Testing & Commissioning of flood light 80watt with all respect
Providing and fixing Aluminium Ventilator Louvers with 5 mm thick glass with all respect
Digitally signed by
ISTPage 77 of 103
BOQ Summary of Development Work
Name of Work:- Construction of Permanent Campus at JNV Nandurbar-I (Maharashtra)
Amount (DSR- Amount (DSR
S.No Description NS AMOUNT Total Cost
with correction E/M with correction
4 External Water Supply 4,42,155 - - 4,42,155
5 External Sewerage 4,45,949 - 1,42,414 5,88,363
7 Strom Water Drain (300 x 450 mm)-128.78 Metre 4,66,597 - - 4,66,597
8 Rain Water Harvesting-02 Nos 9,20,104 - - 9,20,104
9 External Electrification - 3,58,191 27,58,128 31,16,319
10 Septic tank and Soak well (200 user-01 Nos) 7,78,050 - - 7,78,050
11 Septic tank and Soak well (300 user-01 nos) 11,96,732 - - 11,96,732
12 Solar Photo Voltaic Power Generation System-30KWp - - 17,48,505 17,48,505
Digitally signed by
ISTPage 78 of 103
BOQ -Earth Work
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
Rate- DSR-2023 DSR-2022 Amount (DSR- Amount (DSR
(DSR- DSR.202 Rate (incl. CF DSR 2022 E/M Rate (incl. 2023) Civil 2022+GST
Sl.No Description of Item Unit Qty Rate -NS NS AMOUNT
2023) 3 0.973 + CI E/M Rate CF 0.973+CI with correction 6.33%) E/M with
7%) 4.08% ) factor correction factor
Excavating, supplying, stacking and filling of local earth
(including royalty) by mechanical transport upto a lead of
1 2.25(a) 5km also including ramming and watering of the earth in Cum 200 700.5 729.298 - - 1,45,859.51
layers not exceeding 20 cm in foundation trenches, plinth,
sides of foundation etc. complete for all lift.
Disposal of building rubbish / malba / similar unserviceable,
dismantled or waste materials by mechanical
2 15.60 means, including loading, transporting, unloading to Cum 200 263.95 274.801 54,960.20
approved municipal dumping ground or as approved
by Engineer-in-charge, beyond 50 m initial lead, for all
leads including all lifts involved.
Digitally signed by AMIT JAIN
IST Page 79 of 103
BOQ - Pathway work
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate
(DSR- DSR 2022 2023) Civil 2022+GST 6.33%)
Sl.No Description of Item Unit Qty DSR.2023 (incl. CF 0.973 (incl. CF Rate -NS NS AMOUNT
2023) E/M Rate with correction E/M with correction
1 Earth work in surface excavation not exceeding 30 cm in depth
but Earth work in surface excavation not exceeding 30 cm in
depth but exceeding 1.5 m in width as well as 10 sqm on plan
2 including getting out and disposal of excavated earth upto 50 m
and lift upto 1.5 m, as directed by Engineer-in- Charge
3 Providing and laying in plane cement concrete of specified
4.1 grade excluding the cost of centering and shuttering - All work
up to plinth level
4 1:5:10 (1 cement : 5 coarse sand : 10graded stone aggregate Cum 10.000 6518.6 6,786.580 - - - 67,866
4.1.10 40 mm nominal size)
5 Centering and shuttering including strutting, propping etc. and 0.0 - - - - -
removal of form work for :
6 4.3.1 Foundations, footings, bases for columns Sqm 32.0 392.2 408.271 - - - 13,065
7 Providing and laying 60mm thick faciory made cement concrete sqm 250.0 972.0 1,011.959 - - - 2,52,990
interlocking paver block of M -30 grade made by block making
machine with strong vibratory compaction, of approved size,
design & shape, laid in required colour and pattern over and
16.68 including 50mm thick compacted bed of coarse sand, filling the
joints with line sand etc. all complete as per the direction of
Engineer-in-charge
8 Providing and laying at or near ground level factory made kerb Cum 9.00 10117.6 10,533.535 - - - 94,802
stone of M-25 grade cement concrete in position to the required
line, level and curvature, jointed with cement mortar 1:3 (1
cement: 3 coarse sand), ncluding making joints with or without
grooves (thickness of joints except at sharp curve shall not to
more than 5mm), including making drainage opening wherever
required complete etc. as per direction of Engineer-in-charge
16.69 (length of finished kerb edging shall be measured for payment).
(Precast C.C. kerb stone shall be approved by Engineer-in-
9 Finishing walls with Premium Acrylic Smooth exterior paint with 0.0 - - - - -
13.47 Silicone additives of required shade :
10 New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over Sqm 100.0 171.1 178.134 - - - 17,813
13.47.1 and including priming coat of exterior primer applied @ 2.20
Digitally signed by AMIT JAIN
IST Page 80 of 103
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
DSR-2022 Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate (incl. 2023) Civil 2022+GST 6.33%)
(DSR- DSR.2023 (incl. CF 0.973 + DSR 2022 CF 0.973+CI with correction E/M with correction
Sl.No 2023) Description of Item Unit Qty CI 7%) E/M Rate 4.08% ) Rate -NS factor factor NS AMOUNT
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m
in width as well as 10 sqm on plan) including getting out and disposal of
excavated earth lead upto 50 m and lift upto 1.5 m, as directed by
Engineer-in-charge.
All Kinds of Soil
Preparation and consolidation of sub grade with power road roller of 8 to
12 tonne capacity after excavating earth to an average of 22.5 cm depth,
dressing to camber and consolidating with road roller including making
good the undulations etc. and re-rolling the sub grade and disposal of
surplus earth with lead upto 50 metres.
Supplying and stacking at site.
6 16.3.2 63 mm to 45 mm size stone aggregate Cum 28.47 1636.05 1,703.308 - 48,493
53 mm to 22.5mm size stone aggregate
stone screening 13.2 mm nominal size (Type A )
Stone screening 11.2 mm nominal size (Type B)
Laying, spreading and compacting stone aggregate of specified sizes to
WBM specifications in uniform thickness, hand picking, rolling with 3
wheeled road / vibratory roller 8-10 tonne capacity in stages to proper
grade and camber, applying and brooming requisite type of screening /
binding material to fill up interstices of coarse aggregate, watering and
compacting to the required density .
Qty as per item NO. 16.3.2
Qty as per item NO. 16.3.3
Qty as per item NO. 16.3.6
Providing and laying C.C. pavement of mix M-25 with ready mixed
concrete from batching plant. The ready mixed concrete shall be laid and
finished with screed board vibrator , vacuum dewatering process and
finally finished by floating, brooming with wire brush etc. complete as per
specifications and directions of Engineer-incharge. (The panel shuttering
work shall be paid for separately). (Note:- Cement content considered in
this item is @ 330 kg/cum. Excess/less cement used as per design mix is
payable/ recoverable separately).
Digitally signed by AMIT JAIN
IST Page 81 of 103
DSR-2022 Amount (DSR- Amount (DSR
Rate- DSR-2023 Rate E/M Rate (incl. 2023) Civil 2022+GST 6.33%)
(DSR- DSR.2023 (incl. CF 0.973 + DSR 2022 CF 0.973+CI with correction E/M with correction
Sl.No 2023) Description of Item Unit Qty CI 7%) E/M Rate 4.08% ) Rate -NS factor factor NS AMOUNT
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering. All work upto plinth level.
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources
: 8 graded stone aggregate 40 mm nominal size derived from natural
Centering and shuttering including strutting, propping etc. and removal of
20 form for all heights : 0 - -
Foundations, footings, bases of columns, etc. for mass concrete.
Painting with synthetic enamel paint of approved brand and manufacture
of required colour to give an even shade :
Two or more coats on new work over an under coat of suitable shade with
23 13.62.1 ordinary paint of approved brand and manufacture Sqm 50 226.25 235.551 - 11,778
Providing & laying in position bitumen hot sealing compound for
expansion joints
Using garde A sealing compound
Supplying and stacking at site.
Filling available excavated earth (excluding rock) in trenches, plinth, sides
of oundations etc. in layers not exceeding 20cm in depth, consolidating
each deposited layer by ramming and watering, lead up to 50 m and lift
Digitally signed by AMIT JAIN
IST Page 82 of 103
BOQ - External Water Supply
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
DSR-2022 Amount (DSR-2023) Amount (DSR
Rate- DSR-2023 Rate
DSR 2022 E/M E/M Rate (incl. Civil 2022+GST 6.33%)
Sl.No (DSR-2023) Description of Item Unit Qty DSR.2023 (incl. CF 0.973 Rate -NS NS AMOUNT
Rate CF 0.973+CI with correction E/M with
4.08% ) factor correction factor
DISTRIBUTION NETWORK FOR FRESH WATER SUPPLY
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1 1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
2 External work
4 18.7.4 32 mm dia nominal bore Metre 2.00 335 348.8 - 697.54
18.8 Providing, laying, testing & commissioning of 'B' class medium duty -
G.I. pipe conforming to IS 1239 including welding, fittings like elbows,
tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on
7 the wall/ceiling with suitable clamp/support frame and painting with - -
two or more coats of synthetic enamel paint of required shade
comolete as required.
18.59 Providing and fixing C.I. double acting air valve of approved quality -
10 with bolts, nuts, rubber insertions etc. complete (The tail pieces, - -
tapers etc if required will be paid separately) :
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved -
quality (screwed end) :
14 18.17.1A 20 mm nominal bore Each 539.95 562.1 - -
4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural Cum 6.00 7878.50 49,214.31
21 sources : 4 graded stone aggregate 20 mm nominal size derived from 8,202.4 -
natural sources)
18.46 Providing and fixing G.I. Union in GI pipe including cutting and -
22 threading the pipe and making long screws etc. complete(New work) - -
Digitally signed by AMIT JAIN
IST Page 83 of 103
DSR-2022 Amount (DSR-2023) Amount (DSR
Rate- DSR-2023 Rate
DSR 2022 E/M E/M Rate (incl. Civil 2022+GST 6.33%)
Sl.No (DSR-2023) Description of Item Unit Qty DSR.2023 (incl. CF 0.973 Rate -NS NS AMOUNT
Rate CF 0.973+CI with correction E/M with
4.08% ) factor correction factor
19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and -
frame of required shape and approved quality
27 19.19.1.1 Rectangular shape 600*450 mm internal dimensions Each 12.00 1437.65 1,496.8 - 17,961.02
18.32 Constructing masonry gate valve Chamber 30x30x50 cm inside, in -
brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop
cock, with C. I. surface box 100x100 x75 mm (inside) with hinged
cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary
28 excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 - -
graded stone aggregate 40mm nominal size ) and inside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick,
finished with a floating coat of neat cement complete as per standard
18.32.1 With common burnt clay F.P.S.(non modular) bricks of class Each 20.00 1992.60 41,490.32
designation 7.5
18.33 Constructing masonry Chamber 60x45x50 cm inside, in brick work in -
cement mortar 1:4 (1 cement : 4 coarse sand) for water meter
complete with C.I. double flap surface box 400x200x200 mm (inside)
with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c
30 necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine - -
sand:10 graded stone aggregate 40 mm nominal size) and inside
plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm
thick, finished with a floating coat of neat cement complete as per
standard design :
18.33.1 with common burnt clay F.P.S.(non module) brick of class designation Each 5.00 10862.40 56,544.77
Digitally signed by AMIT JAIN
IST Page 84 of 103
BOQ - External Sewerage
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
Rate- DSR-2023 Rate DSR-2022 E/M Amount (DSR-2023) 2022+GST
Sl.No (DSR-2023) Description of Item Unit Qty DSR.2023 (incl. CF 0.973 + DSR 2022 E/M Rate Rate (incl. CF Rate -NS Civil 6.33%) E/M NS AMOUNT
CI 7%) 0.973+CI 4.08% ) with correction factor with correction
1 SUB HEAD (I) :- EXTERNAL SEWERAGE SYSTEM
2 2.13 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and
dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and
then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each
deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a
3 2.13.1 Ordinary rock :
4 2.13.1.2 Pipes, cables etc. exceeding 80 mm dia but not
exceeding 300 mm dia metre 10.00 352.15
Supply and fixing HDPE double wall corrugated I.S 16098 ( Part - 2 ) 3013 for soil / waste pipe under
ground drainage system with jointed with rubber ring with good quality lubricant for fittings, inclusive of
all necessary specials like bends, tees, offsets, junctions, re excavtion and refillig etc complete.
8 19.2 Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 gradded stone
aggregate 40 mm nominal size) alround S.W. Pipes including bed concrete as per standard design. - -
10 19.7 Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse sand) with RCC top
slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size);
foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal
size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a - -
floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand:
4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as
per standard design
19.7.1 Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal
11 dimensions, total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg and weight - -
of frame 15 kg)
12 19.7.1.1 With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5 each 2.00 12,770.55 13,295.547 26,591.09
13 19.8 Extra for depth for manholes: - -
15 19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 9,188.212 91,882.12
16 Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top
with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement
plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of
19.9 of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate - -
40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse
Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement
complete as per standard design.
0.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter
conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement
concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including
centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external
surface shall be paid for separately)
18 19.9.1.1 with common burnt clay F.P.S.(non module) brick of class designation 7.5 Each 14 12,725.00 13,248.125 1,85,473.75
Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m .
20 19.10.1 with common burnt clay F.P.S.(non module) brick of class designation 7.5 Meter 2 7,591.80 7,903.899 15,807.80
19.4 Providing and fixing square mouth S. W. Gully trap class SP-1 complete with C.I. grating brick
masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
23 19.4.3.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 19.00 2,534.00 2,638.173 50,125.28
24 19.15 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1
cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : - -
Digitally signed by AMIT JAIN
IST Page 85 of 103
BOQ - Surface Drain
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
Rate- DSR-2023 Rate Amount (DSR-2023) 2022+GST
(DSR- DSR 2022 Rate (incl. CF Rate -NS
Sl.No Description of Item Unit Qty DSR.2023 (incl. CF 0.973 Civil 6.33%) E/M NS AMOUNT
2023) E/M Rate 0.973+CI
+ CI 7%) with correction factor with correction
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
1 getting out and disposal of excavated earth lead upto 50 m and
lift upto 1.5 m, as directed by Engineer-in-charge.
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
depth: consolidating each deposited layer by ramming and
2.25 watering, lead up to 50 m and lift up to 1.5 m. -
Providing and laying in position cement concrete of specified
5 grade excluding the cost of centering and shttering - All work up - -
4.1 to plinth level -
1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone
4.1.10 aggregate 40 mm nominal size). Cum 6518.6 3,39,329
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate) finished with a floating coat of neat
7 cement, including cement slurry, but excluding the cost of 60 639.450 -
nosing of steps etc. complete
11.3.1 40 mm thick with 20 mm nominal size stone aggregate Sqm 614.2 38,367
Centering and shuttering including strutting, propping etc. and
removal of form for all heights : -
Foundations, footings, bases of columns, etc. for mass concrete
Brick work with F.P.S. bricks of class designation 75 in
foundation and plinth in : -
11 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 30 7132.25 7,425.457 - 2,22,764
12 mm cement plaster finished with a floating coat of neat
13.7 cement of mix : -
Total 6,67,414
Digitally signed by AMIT JAIN
IST Page 86 of 103
BOQ - Strom Water Drain work
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
DSR-2023 DSR-2022 E/M Amount (DSR-
Rate- 2022+GST
(DSR- Rate (incl. DSR 2022 Rate (incl. CF Rate -NS 2023) Civil
Sl.No Description of Item Unit Qty DSR.2023 6.33%) E/M NS AMOUNT
2023) CF 0.973 + E/M Rate 0.973+CI with correction
with correction
CI 7%) 4.08% ) factor
2.6 Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in
1 width as well as 10 sqm on plan) including getting out and disposal of
excavated earth lead upto 50 m and lift upto 1.5 m, as directed by
Engineer-in-charge.
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides - - - -
3 of foundations etc. in layers not exceeding 20cm in depth: consolidating
each deposited layer by ramming and watering, lead up to 50 m and lift up
4.1 Providing and laying in position cement concrete of specified grade - - - -
excluding the cost of centering and shttering - All work up to plinth level
4.1.10 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate cum 1.00 6518.60 6,786.58 - 6,787
40 mm nominal size).
11.3.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone Sqm 350.00 614.20 639.45 - 2,23,807
aggregate) finished with a floating coat of neat cement, including cement
slurry, but excluding the cost of nosing of steps etc. completed 40 mm
thick with 20 mm nominal size stone aggregate
Centering and shuttering including strutting, propping etc. and removal of - - - -
form for all heights :
9 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete Sqm 1.20 392.15 408.27 - 490
10 Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in : - - - -
11 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 1.00 7132.25 7,425.46 - 7,425
13.7 12 mm cement plaster finished with a floating coat of neat cement of mix : - - - -
Providing and laying in position ready mixed or site batched design mix Cum 3.00 9504.75 9,895.49 - 29,686
cement concrete for reinforced cement concrete work; using coarse
aggregate and fine aggregate derived from natural sources, Portland
Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of
concrete, to improve durability and workability without impairing strength;
including pumping of concrete to site of laying, curing, carriage for all
leads; but excluding the cost of centering, shuttering, finishing and
reinforcement as per direction of the engineer-in-charge; for the following
14 5.33.1 grades of concrete Note: Extra cement up to 10% of the minimum specified
cement content in design mix shall be payable separately. In case the
cement content in design mix is more than 110% of the specified minimum
cement content, the contractor shall have discretion to either re-design the
mix or bear the cost of extra cement.
Concrete of M25 grade with minimum cement content of 330 kg /cum
Digitally signed by AMIT JAIN
IST Page 87 of 103
DSR-2023 DSR-2022 E/M Amount (DSR-
Rate- 2022+GST
(DSR- Rate (incl. DSR 2022 Rate (incl. CF Rate -NS 2023) Civil
Sl.No Description of Item Unit Qty DSR.2023 6.33%) E/M NS AMOUNT
2023) CF 0.973 + E/M Rate 0.973+CI with correction
with correction
CI 7%) 4.08% ) factor
Steel reinforcement for R.C.C. work including straightening, cutting, Kg 1,680 107.85 112.28 - 1,88,637
15 5.22.6 bending, placing in position and binding all complete upto plinth
level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of - - - -
Suspended floors, roofs, landings, balconies and access platform with water Sqm 3.00 1028.4 1,070.68 - 3,212
proof ply 12 mm thick
Digitally signed by AMIT JAIN
IST Page 88 of 103
ANALYSIS OF RATE FOR RAIN WATER HARVESTING
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
DSR-2022 Amount (DSR- Amount
Rate- DSR-2023 Rate E/M Rate (DSR
DSR 2022 Rate -NS 2023) Civil NS
Sl.No (DSR-2023) Description of Item Unit Qty DSR.2023 (incl. CF 0.973 + (incl. CF 2022+GST
E/M Rate with correction AMOUNT
4.08% ) E/M with
Earth work in excavation by mechanical means (Hydraulic excavatior)/manual
means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on
plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m,
disposed earth to be levelled and neatly dressed.
2 upto 1.5m depth
4 In Ordinary rock upto 1.5m to 3.0m. Depth - - -
2.9.1+ Ordinary rock 403.01
6 In Ordinary rock upto 3.0m to 4.5m. depth - - -
2.9.1+ Ordinary rock 535.03
8 In Ordinary rock upto 4.5m to 6.0m. depth - - -
2.9.1+ Ordinary rock 667.04
Providing and laying in position cement concrete of specified grade excluding -
the cost of centering and shuttering -All work up to plinth level: 1:5:10 (1
cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded
4.1 stone aggregate 40 mm nominal size derived from natural sources) - -
Brick work with common burnt clay F.P.S. (non modular) bricks of class -
6.1 designation 7.5 in foundation and plinth in: - -
13 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 26.28 7132.25 7,425.46 1,95,141.00
Reinforced cement concrete work inbeams, suspended floors, roofs having slope 11,978.49
up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills,
staircases and spiral stair cases up to floor five level excluding the cost of
centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5
coarse sand :3 graded stone aggregate 20mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, -
15 placing in position and binding all complete upto plinth level.
16 5.22.1 Mild steel and Medium Tensile steel bars. Kg 126.00 107.10 111.50 14,049.36
Centring and shuttering including strutting , propping etc and removal of form -
18 5.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 7.80 927.25 965.37 7,529.88
19 Edges of slabs and breaks in floors and walls - - -
21 13.4 12 mm cement plaster on rough side of single or half brick wall mix - - -
Providing and fixing in position precast RCC manhole cover and frame of -
required shape and approved quality. - -
26 19.19.3.1 HD-20- Circular shape 560mm internal diameter No. 4.00 1675.70 1,744.59 6,978.35
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable - -
method prescribed in IS: 2800 (part I), including collecting samples from
28 different strata, preparing and submitting strata chart/bore log, including hire &
running charges of all equipments, tools, plants & machineries required for the
job, all complete as per direction of Engineer-incharge, upto 90 metre depth
23.1 below ground level. -
Digitally signed by AMIT JAIN
IST Page 89 of 103
30 23.1.1.1 Rockey strata including Boulders (300 mm dia M 40.00 707.75 736.85 29,473.82
Supplying, assembling, lowering and fixing in vertical position in bore well -
unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:
12818, including hire & labour charges, fittings & accessories etc. all complete,
23.4 for all depths, as per direction of Engineer-in-charge. - -
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 1,571.87
35 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete
23.5 as per direction of Engineer-in-charge. cum 3.14 1,509.80 4,935.67
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in 1,601.49
37 the recharge pit, over the existing layer of boulders, in required thickness, for
23.6 all leads & lifts, all complete as per direction of Engineer-in-charge. cum 3.14 1538.25 5,028.67
Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 1,601.49
38 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts,
23.7 all complete as per direction of Engineer-in-charge. cum 3.14 1538.25 5,028.67
Gravel packing in tubewell construction in accordance with IS: 4097, including 2,107.73
39 providing gravel fine/medium/coarse, in required grading & size as per actual
23.8 requirement, all complete as per direction of Engineer-in-charge. Cum 2.00 2024.50 4,215.45
40 TOTAL [A] - -
41 DESILTING CHAMBER - -
Earth work in excavation by mechanical means (Hydraulic excavatior)/manual -
means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on
plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m,
disposed earth to be levelled and neatly dressed. -
43 upto 1.5m depth - -
45 upto 1.5m to 3.0m. depth - - -
47 upto 3.0m to 4.5m. depth - - -
Providing and laying in position cement concrete of specified grade excluding 6,786.58
the cost of centering and shuttering -All work up to plinth level: 1:5:10 (1
cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded
4.1.10 stone aggregate 40 mm nominal size derived from natural sources) Cum 16.00 6518.60 1,08,585.27
Brick work with common burnt clay F.P.S. (non modular) bricks of class -
6.1 designation 7.5 in foundation and plinth in: - -
51 6.1.2 Cement mortar 1:6 (1 cement : 6coarse sand) Cum 25.00 7132.25 7,425.46 1,85,636.42
Reinforced cement concrete work inbeams, suspended floors, roofs having slope 11,978.49
up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills,
52 staircases and spiral stair cases up to floor five level excluding the cost of
centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5
5.3 coarse sand :3 graded stone aggregate 20mm nominal size) Cum 2.28 11505.50 27,310.96
Steel reinforcement for R.C.C. work including straightening, cutting, bending, -
placing in position and binding all complete upto plinth level. - -
54 5.22.1 Mild steel and Medium Tnsile steel bars. Kg 240.00 107.10 111.50 26,760.69
Centring and shuttering including struting , proping etc and removal of form for -
56 5.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 21.94 927.25 965.37 21,180.20
57 Edges of slabs and breaks in floors and walls - - -
59 13.4 12 mm cement plaster on rough side of single or half brick wall mix - - -
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm -
61 cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone
19.15 aggregate 20mm nominal size) as per standard design: - -
Digitally signed by AMIT JAIN
IST Page 90 of 103
Providing and fixing in position precast RCC manhole cover and frame of -
required shape and approved quality. - -
64 19.19.1.1 LD-2.5 Rectangular shape 600x450mm internal dimensions No. 5.00 1437.65 1,496.75 7,483.76
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement
mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I.
double flap surface box 400x200x200 mm (inside) with locking arrangement
and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete
65 18.37.1 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal No. 5.00 9698.55 10,097.26 50,486.29
size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
12 mm thick, finished with a floating coat of neat cement complete as per
standard design : With common burnt clay F.P.S.(non modular) bricks of class
designation 7.5
Digitally signed by AMIT JAIN
IST Page 91 of 103
BOQ -External Electrical work
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
Rate- DSR-2023 DSR-2022 E/M (DSR-2023) Amount (DSR
DSR.20 Rate (incl. CF DSR 2022 E/M Rate (incl. CF Civil 2022+GST
Sl.No (DSR-2023) Description of Item Unit Qty Rate -NS NS AMOUNT
23 0.973 + CI Rate 0.973+CI 4.08% with 6.33%) E/M with
7%) ) correction correction factor
1 SUB HEAD - I : HT EQUIPMENT & TRANSFORMER
Providing and fixing MV Danger Notice Plate of 200 mm x 150 mm, made of
mild steel, at least 2 mm thick, and vitreous enamelled white on both sides
and with inscription in single red colour on front side as required.
3 DSR 2.22 P/ F HT Danger Notice Plate - -
Providing and fixing HT danger notice plate of 250 mm x 200 mm, made of
mild steel, at least 2 mm thick, and vitreous enamelled white on both sides
4 and with inscription in single red colour on front side as required. Each 2 292.00 314.4262 629
11 KV HT DP STRUCTURE-Supply, Installation, testing and commissioning
of 11 KV DP structure as per CEI & SEB norms & comprising of the
5 NS-21 following, but not limited to it for completion of works
RSJ pole of 9.15 mt length of size 175 x 90 mm complete with suitable
6 1.1 M.S. base plate welded at bottombase plate - 2 Nos. - -
7 1.2 MS Channel of size 100 x 50 mm, length 4 mts (approx) - -
8 1.3 11 KV AB switch - 1 set - -
9 1.4 11 KV Horn Gap fuse Unit - 1 set - -
10 1.5 11 KV Lightning Arrestor - -
11 1.6 11 KV Disc insulator - -
12 1.7 11 KV Pin insulator - -
13 1.8 6 SWG copper wire for jumpering - -
Supply and erection of Stay set complete with necessary foundation,
14 1.9 excavation and refilling of earth etc. as required. - -
Concrete foundation for RSJ poles burrioed upto a depth of 1830 mm in
ground in a pit of size 450X450 mm in CC 1:3:6 along with 200 mm
Necessary Nut, ground inclusiveoperating
Bolts, clamps, of earth handle
work. for AB switch, clamping
welding etc. complete as required.
Painting the RSJ poles complete with two coat of Red Oxide and two coats
of GI enamel paints complete as required.
18 Transpotation of all materials and accessories at site - -
19 Complete erection, testing and commissioning. Set 1 - 4,79,699.50 - 4,79,699.50
20 NS-22 Supply, erection, testing and commissioning of 230V, single phase 2 wire ACSet 1 - 1,37,057.00 - 1,37,057.00
DISTRIBUTION TRANSFORMERS-Supply, installation, testing and
commissioning of 250 kVA 11000/433 volts Deta/Star, vector group DY11,
21 NS-23 outdoor mounting, oil cooled, ONAN transformer with ON Load Tap Changer 1 - 13,70,570.00 - 13,70,570.00
(OLTC) AVS relay and RTCC for automatic sensing of incoming voltage,
automatic operation of OLTC and facility for remote manual operation of On Set
Laying of one number PVC insulated and PVC sheathed / XLPE power cable
22 DSR 8.1 of 11 KV grade of following size direct in ground including excavation, sand - -
cushioning, protective covering and refilling the trench etc as required.
Digitally signed by AMIT JAIN
IST Page 92 of 103
Rate- DSR-2023 DSR-2022 E/M (DSR-2023) Amount (DSR
DSR.20 Rate (incl. CF DSR 2022 E/M Rate (incl. CF Civil 2022+GST
Sl.No (DSR-2023) Description of Item Unit Qty Rate -NS NS AMOUNT
23 0.973 + CI Rate 0.973+CI 4.08% with 6.33%) E/M with
7%) ) correction correction factor
Above 120 sq. mm and upto 400 sq. mm.
supplying and making indoor cable end termination with heat shrinkable
24 DSR 10.4 jointing kit complete with all accessories including lugs suitable for following - -
size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required
Supplying and making outdoor cable end termination with heat shrinkable
26 DSR 10.5 jointing kit complete with all accessories including lugs suitable for following - -
size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required
28 DSR-14.14 P/ F RCC Hume Pipe - -
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in
ground complete with RCC collars, jointing with cement mortar 1:2 (1
29 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as - -
32 NS-24 Supply of fire buckets 4 No. in each set duly filled with fine sand and fixed onSets 1 - 4,659.94 - 4,659.94
Supply and fixing on position the approved Single Line Diagram framed in
33 NS-25 1000 x 800 mm size glass frame and installed in main switch room as 1 - 2,295.70 - 2,295.70
directed by Engineer Incharge
Supply of First Aid box as directed by Engineer Incharge
Supply of tool kit with 1 pair 11 KV rubber hand gloves as directed by
35 NS-27 Engineer Incharge. 1 - 1,850.27 - 1,850.27
Supplying & fixing standard shock treatment charts in English & Hindi duly
framed and covered with glass as directed by Engineer Incharge. Nos
Providing Safety mat made of elastomeric polymers Material (Class B) 1.2
37 NS-29 M wide with thickness 2.5 mm to withstand 12KV dielectric strength AS 2 - 1,850.27 - 3,700.54
PER relevant IS Code RM
Providing a mat made of elastomeric polymers Material (Class A )1.2 M
38 NS-30 wide with 2 mm thickness to withstand 1.1 KV dielectric strength AS PER 2 - 1,617.27 - 3,234.55
relevant IS Code RM
39 NS-31 FEDDER PILLAR -1
40 INCOMER - - -
1 No.200 Amp FP MCCB, 35 kA breaking capacity with thermal release and
adjustable setting and with rotary handle.
42 METERING & INDICATION - - -
43 1 set of R,Y,B phase indicating lamps - - -
Digital Multifunction meter for Voltage, Current & KW with selector switch.
44 Each with 3nos. of 2A SP MCB & 3nos 200/5A CTs (200A/500V) rating - - -
45 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps as - - -
46 BUS-BAR - - -
47 1 Set of 250A TPN Aluminium Bus Bar with colour coded PVC Sleeves - - -
Digitally signed by AMIT JAIN
IST Page 93 of 103
Rate- DSR-2023 DSR-2022 E/M (DSR-2023) Amount (DSR
DSR.20 Rate (incl. CF DSR 2022 E/M Rate (incl. CF Civil 2022+GST
Sl.No (DSR-2023) Description of Item Unit Qty Rate -NS NS AMOUNT
23 0.973 + CI Rate 0.973+CI 4.08% with 6.33%) E/M with
7%) ) correction correction factor
48 OUTGOINGS - - -
2 Nos.100 Amp FP MCCB, 25 kA breaking capacity with thermal release and
adjustable setting and with rotary handle.
6 Nos.63 Amp FP MCCB, 25 kA breaking capacity with thermal release and
adjustable setting and with rotary handle.
51 Supplying,Receiving, fixing, testing & commissioning of above Sets 1 - 2,05,585.50 - 2,05,585.50
described Panel
52 NS-32 MDB PANEL TYPE-3 (G+2)
53 INCOMER - - -
1 No.63 Amp FP MCCB, 25 kA breaking capacity with thermal release and
adjustable setting and with rotary handle.
55 METERING & INDICATION - - -
56 1 set of R,Y,B phase indicating lamps - - -
Digital Multifunction meter for Voltage, Current & KW with selector switch.
57 Each with 3nos. of 2A SP MCB & 3nos 63/5A CTs (63A/500V) rating - - -
1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps as
59 BUS-BAR - - -
60 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves - - -
61 OUTGOINGS - - -
Supplying,Receiving, fixing, testing & commissioning of above
described Panel
64 SUB HEAD -IV : LT CABLES & CABLE TRAYS - - -
Laying of one number PVC Insulated and PVC shethed /XLPE power Cables
65 DSR-7.1 of 1.1 KV grade of following size direct in ground including excavation,sand - - -
cushioning and protecting covering and refilling the trench etc as required.
67 DSR-7.1.2 Above 35 sq mm and up to 95 sq mm. Metre 100 405.00 436.10 43,610.49 -
68 DSR-7.1.3 Above 95 sq mm and up to 185 sq mm. Metre 100 422.00 454.41 45,441.05 -
69 DSR-7.1.4 Above 185 sq mm and up to 400 sq mm. Metre 100 474.00 510.40 51,040.42 -
Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of
70 DSR 7.5 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as - - -
72 DSR-7.5.2 Above 35 sq. mm and upto 95 sq. mm RM 10 57.00 61.38 613.78 -
73 DSR-7.5.3 Above 95 sq.mm and upto 185 sq.mm RM 10 77.00 82.91 829.14 -
Above 185 sq.mm and upto 400 sq.mm
Laying and fixing of one no PVC insulated and PVC sheathed /XLPE power
75 DSR 7.8 cable of 1.1 kV grade of following size on Cable tray as required. 10 - - -
Up to 35 sq mm. (Clambed with 1mm thick saddle)
Above 35 sq mm and up to 95 sq mm. (Clambed with 25 x 3 mm thick MS
Above 95 sq. mm and upto 185 sq. mm (Clamped with 25/40x3mm MS flat
Digitally signed by AMIT JAIN
IST Page 94 of 103
Rate- DSR-2023 DSR-2022 E/M (DSR-2023) Amount (DSR
DSR.20 Rate (incl. CF DSR 2022 E/M Rate (incl. CF Civil 2022+GST
Sl.No (DSR-2023) Description of Item Unit Qty Rate -NS NS AMOUNT
23 0.973 + CI Rate 0.973+CI 4.08% with 6.33%) E/M with
7%) ) correction correction factor
Above 185 sq mm and up to 400 sq mm. (Clambed with 25/40 x 3 mm
Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire
Armoured, overall PVC sheathed 1.1 KV grade cables conforming to
80 NS-33 relevant IS-7098 Code and technical specifications. - - -
Supply and making End termination with brass Single/ Double compression
gland including providing and crimping of aluminum/copper solderless
94 NS-34 lugs/ferrules for XLPE/PVC insulated armoured power aluminum/copper - - -
conductor cables 1.1 KV grade of following sizes:
SINGLE COMPRESSION GLAND FOR AI. AR. CABLE-4C/3C x 6/4 sq.mm.
Supplying and making end termination with brass compression gland and
96 DSR 9.1 aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE - - -
aluminium conductor cable of 1.1 KV grade
109 TOTAL CARRIED TO SUMMARY SHEET FOR SUBHEAD IV - - -
110 SUB HEAD -V : EARTHING SYSTEM - - -
Digitally signed by AMIT JAIN
IST Page 95 of 103
Rate- DSR-2023 DSR-2022 E/M (DSR-2023) Amount (DSR
DSR.20 Rate (incl. CF DSR 2022 E/M Rate (incl. CF Civil 2022+GST
Sl.No (DSR-2023) Description of Item Unit Qty Rate -NS NS AMOUNT
23 0.973 + CI Rate 0.973+CI 4.08% with 6.33%) E/M with
7%) ) correction correction factor
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
accessories, and providing masonry enclosure with cover plate having
111 DSR 5.4 locking arrangement and watering pipe of 2.7 metre long etc. with 2 7,472.00 8,045.87 16,091.73 -
charcoal/ coke and salt as required.
Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including
112 DSR 5.6 accesssories, and providing masonary enclosure with cover plate (CI 2 13,838.00 14,900.79 29,801.58 -
heavy duty) having locking arrangement and watering pipe of 2.7 mtr long
etc. with charcoal or coke and salt ) as required. Sets
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from
113 DSR 5.11 earth electrode including connection with G.I. nut,bolt, spring, washer 2 706.00 760.22 1,520.44 -
excavation and re-filling etc. as required. Metre
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe
114 DSR 5.10 from earth electrode including connection with brass nut, bolt, spring, 2 1,551.00 1,670.12 3,340.24 -
washer excavation and re-filling etc. as required. Metre
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for
115 DSR 5.14 connections etc. as required. 2 nos used for 50 x 5 for the Neutral earthing 10 1,162.00 1,251.24 12,512.44 -
of euipments ) Metre
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for
connections etc. as required. Metre
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop
117 DSR 5.18 earthing along with existing surface/ recessed conduit/ submain wiring/ 2 42.00 45.23 90.45 -
cable as required. Metre
Supplying, fixing, testing and commissioning of following bare Copper/ GI
flat including all necessary fixing accessories and effecting connections.
119 NS-35-1 50 mm x 6 mm thick Cu flat Metre 1 - 4,797.00 - 4,797.00
120 NS-35-2 50 mm x 6 m thick GI flat Metre 1 - 507.11 - 507.11
121 NS-36 Supply and laying medium class GI pipe under road/paved areas/wall crossinMetre 2 - 2,398.50 - 4,797.00
122 NS-37 Supplying, fixing, testing and commissioning of following size PVC sleeve for Metre 2 - 3,817.04 - 7,634.07
Erection of metallic pole of following length in cement concrete 1:3:6 (1
cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
foundation including excavation and refilling etc. as required.-Above 3.0
metre and upto 4.0 metre Each
Supplying, installation, testing and commissioning of Spyke light fitting
124 NS-39 suitable for 8 watt IP 65LED having system lumen output of minimum 1 - 6,578.74 - 6,578.74
750 lumens complete with all accessories and lamp.
Supplying, installation, testing and commissioning of Bollard light fitting
125 NS-40 suitable for 11 watt IP 65LED having system lumen output of minimum 1 - 7,775.24 - 7,775.24
900 lumens complete with all accessories and lamp. Nos.
Supplying, installation, testing and commissioning of Gate light fitting
suitable for 42 watt IP 65LED having system lumen output of minimum
4200 lumens complete with all accessories and lamp.
Supplying, installation, testing and commissioning of 45W LED Street
Light IP66 LED with High performance having system lumen output of
127 NS-42 minimum 4500 lumens, contemporary designed housing made of die-cast 1 - 8,045.25 - 8,045.25
aluminium, with street optic LENS for uniform light distribution. PF better
than 0.9, CRI better than 70 complete with all accessories. Nos.
Digitally signed by AMIT JAIN
IST Page 96 of 103
Rate- DSR-2023 DSR-2022 E/M (DSR-2023) Amount (DSR
DSR.20 Rate (incl. CF DSR 2022 E/M Rate (incl. CF Civil 2022+GST
Sl.No (DSR-2023) Description of Item Unit Qty Rate -NS NS AMOUNT
23 0.973 + CI Rate 0.973+CI 4.08% with 6.33%) E/M with
7%) ) correction correction factor
Supplying, installation, testing and commissioning of 45W LED Solar
Street Light On 4.0 Meter GI octagonal Pole having Compact,
Aesthetic, Eco friendly & modern integrated Solar street light in extruted
Aluminum construction with high efficiency monocrystalline silicon photo
voltaic panel, high efficacy SMD LED 6500K having secondary lens optics
128 NS-43 for street lighting distribution, high performance lithium battery, MPPT 5 - 22,867.96 - 1,14,339.80
charge controller & Intelligent control module/sensor with higher reliability,
long service life, suitable for easy & quick installation.
Supply, testing & commissioning of 3.0 meter high G.I octagonal pole
(Above Ground Level) with single/double arm as per requirement of
suitable length with inbuilt junction box with 10A SP MCB, connectors for
incoming/outgoing cable connection and 300mm x 300mm x 20 mm thick
base plate and bracket (double arm/single arm whichever required)
complete in all respect.
Providing, installation of 200 x 150 x 125 mm polycarbonate weather proof
130 NS-45 (IP-55) junction box and SP MCB’s and terminal block. 2 - 3,719.73 - 7,439.45
Supplying and laying cable through GI pipe upto junction box including
excavation and back filling, wiring with 2 x 2.5 sq.mm PVC insulated 1100
131 NS-46 volts grade copper conductor wires from junction box to lighting fixture 20 - 165.84 - 3,316.78
Supplying and fixing following rating, Single/ double/ three pole, 230/ 415
volts, MCB "C" curve in the existing MCB DB complete with connections,
testing and commissioning etc. as required.
Supply of 15W SURFACE MOUNTED LED with all accessories as per
135 NS-48 standard item. 2 328.94 657.87
Supply of 15W WALL BRACKET LED BULB with all accessories as per
Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per
Supply of 18W SURFACE MOUNTED LED TUBE with all accessories as per
Digitally signed by AMIT JAIN
IST Page 97 of 103
BOQ- SEPTIC TANK (200 USER'S)-01 nos
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
Rate- DSR-2023 Rate E/M Rate 2022+GST
DSR 2022 2023) Civil
Sl.No (DSR-2023) Description of Item Unit Qty DSR.2023 (incl. CF 0.973 (incl. CF Rate -NS 6.33%) E/M NS AMOUNT
E/M Rate with correction
+ CI 7%) 0.973+CI with
4.08% ) correction
Size of Tank = 8.90 X 2.70 X 1.70 Mtr
Excavation work by mechanical means (Hydraulic excavator)/ manual
means in foundation trenches or drains (not exceeding 1.5m in width or
10 sqm on plan), including dressing of sides and ramming of bottoms, lift
upto 1.5 m, including getting out the excavated soil and disposal of
1 surplus excavated soils as directed, within a lead of 50 m.
Excavation work by mechanical means (Hydraulic excavator)/ manual
means in foundation trenches or drains (not exceeding 1.5m in width or
10 sqm on plan), including dressing of sides and ramming of bottoms, lift
3 upto 1.5 m, including getting out the excavated soil and disposal of -
surplus excavated soils as directed, within a lead of 50 m.
4 Earth work in Excavation 1.50-3.00 mtr - - -
Filling available excavated earth (excluding rock) in trenches, plinth, sides
of foundations etc. in layers not exceeding 20cm in depth, consolidating
6 2.25 each deposited layer by ramming and watering, lead up to 50 m and lift -
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth level
1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate
40 mm nominal size). Cum 2.76 6518.60 18,697.03
Providing and laying in position machine batched and machine mixed
design mix M-25 grade cement concrete for reinforced cement concrete
work, using cement content as per approved design mix, including
pumping of concrete to site of laying but excluding the cost of centering,
shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard setting of
10 5.33.1 concrete, improve workability without impairing strength and durability as Cum 24.11 9504.75 9,895.490 2,38,530.79
per direction of Engineer-in-charge.“(Note :- Cement content considered in
this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is
payable/recoverable separately).
Centering and shuttering including strutting, propping etc. and removal of
11 5.9 form for: -
12 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. Sqm 136.58 392.15 408.271 55,761.69
Digitally signed by AMIT JAIN
IST Page 98 of 103
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
Rate- DSR-2023 Rate E/M Rate 2022+GST
DSR 2022 2023) Civil
Sl.No (DSR-2023) Description of Item Unit Qty DSR.2023 (incl. CF 0.973 (incl. CF Rate -NS 6.33%) E/M NS AMOUNT
E/M Rate with correction
+ CI 7%) 0.973+CI with
4.08% ) correction
13 5.9.21 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 6.97 841.95 876.563 6,105.26
14 5.9.20 Suspended floors, roofs, landings, balconies and access platform. Sqm 24.03 1028.40 1,070.678 25,728.38
15 5.9.16 Edges of slabs and breaks in floors and walls. - -
Reinforcement for R.C.C. work including straightening, cutting, bending,
5.22 placing in position and binding all complete.
18 5.22.6 Thermo-Mechanically Treated bars. Kg 2,500.00 107.85 112.284 2,80,709.28
52 mm thick cement concrete flooring with concrete hardener topping
under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm
thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2
graded stone aggregate 6mm nominal size) by volume. Hardening
19 11.4 compound is mixed @ 2 litre per 50kg of cement or as per manufactures 1,018.674
specifications. This includes cost of cement slurry, but excluding the cost
of nosing of steps etc. complete.
23 13.16 6 mm cement plaster on rough side of single or half brick wall of mix:
Providing and fixing in position pre-cast R.C.C. manhole cover and frame
25 of required shape and approved quality
27 19.19.3.1 Circular shape 560 mm internal diameter Nos 2.00 1675.70 1,744.588 3,489.18
Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS :
1786 having minimum cross section as 23 mmx25mm and over all
minimum length 263 mm and width as 165mm with minimum 112 mm
space between protruded legs having 2 mm tread on top surface by
ribbing or chequering besides necessary and adequate anchoring
projections on tail length on 138 mm as per standard drawing and suitable
to with stand the bend test and chemical resistance test as per
28 19.16 specifications and having manufacture ’s permanent identification mark to Nos 18.00 553.70 576.463 10,376.33
be visible even after fixing, including fixing in manholes with 30x20x15 cm
cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) complete as per design.
Providing and fixing soil, waste and vent pipes
31 17.35.1.2 Centrifugally cast (spun) iron socketed pipe as per IS: 3989. Mtr 5.40 1180.75 1,229.291 6,638.17
32 Providing and fixing terminal guard : - - -
Digitally signed by AMIT JAIN
IST Page 99 of 103
Name of Work:- Construction Parallel extension of the existing school building and additional staff quarters work at JNV Nandurbar-I (MH).
Rate- DSR-2023 Rate E/M Rate 2022+GST
DSR 2022 2023) Civil
Sl.No (DSR-2023) Description of Item Unit Qty DSR.2023 (incl. CF 0.973 (incl. CF Rate -NS 6.33%) E/M NS AMOUNT
E/M Rate with correction
+ CI 7%) 0.973+CI with
4.08% ) correction
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick
honey comb shaft with bricks of class designation 75 and S.W. drain pipe
100 mm diameter, 1.8m long complete as per standard design.With F.P.S.
Digitally signed by AMIT JAIN
IST Page 100 of 103
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
1 NIT.pdf
Tender Document
2 BOQ NANDURBAR.pdf
Tender Document
3 INTEGRITY PACT.pdf
Tender Document
4 LIST OF APPROVED MAKES.pdf
Tender Document
5 PHYSICAL MILESTONE.pdf
Tender Document
6 TENDER DRAWINGS.pdf
Tender Document
7 TECHNICAL SPECIFICATION.pdf
Tender Document
8 SCC.pdf
Tender Document
9 GCC Contracting for PMC Works 2022.pdf
Tender Document
corrigendum-4931-Nandurbar Corrigendum Financial opening .pdf
pdf • 0.15 MB
corrigendum-4706-Corrigendum 01.pdf
pdf • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .