Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.0 L+₹1.3 L (3.88%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹35.4 L+₹2.7 L (8.34%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹35.9 L+₹3.2 L (9.87%)Rejected-Finance 208 L MODEL TOWN LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹36.0 L+₹3.2 L (9.92%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
21 Jul 2022, 6:00 pmClosed
Maj Vijay Kumar Sharma
Garrison Engineer West 62 Station Road Agra Cantt
SPECIAL REPAIRS OF RESIDENTIAL BUILDING AT LEKHA NAGAR,AGRA RESIDENTIAL BUILDINGS, AGRA
2022_MES_516779_3
8012/874/E8
Open Tender
Civil Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹79,000
Yes
25 Aug 2022
16 Jun 2022
23 Jul 2022
16 Jun 2022
21 Jul 2022
24 Jun 2022
Amount
Taking down chowkhat or frame with shutters (without taking off shutter from the frames), area of opening not exceeding 1.5 sqm each complete all as specified and directed.
Description all as per item No-1 above but exceeding 1.50 sqm and n. exc 4.00 sqm each
Demolition of concrete in ground floor and paving n.exc 15cm th (below or above ground level) including removal of rubbish from site complete all as specified and directed.
Taking down cement plaster from walls incl racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in fondation,sub base to path paving etc.complete all as specified and directed.
S&F solid PVC frame of size 50x47mm made out of 5mm single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with MS Square tube supplying & fixing in opening as per specification and drawing complete all as specified and directed.
S&F factory made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, with with wood free EPS fixed in frame at site as per specification & drawing complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in lintel upto 1.5M clear span sesmic and other similar bands, coping, bed block, benching etc complete all as specified and directed.
M&L for 15mm thick rendering on walls in CM 1:6 on fair faces of brick work finished even & smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering on walls in CM 1:4 on fair faces of brick work or concrete surfaces mixed with WPC @ 2% by weight of cement or as per manufacturers instructions complete all as specified and directed. (WPC measured & paid separately)
M&L for 10mm thick rendering on ceiling in CM 1:3 finishing the surface fair & even complete all as specidied and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection finshed even and smooth without using extra cement including forming joints to full depth at every 3M intervals and at every change of direction and filling with bitumen sand mixture 1:3 by weight complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) 25 mm thick as in leveling course / base for tile complete all as specified and directed.
M&L for glazed ceramic tiles coloured, joint free of size 350x 250x 7 mm/ 450X 350X 7mm thick as in dado and skirting etc and jointed in neat cement slurry over and incuding 10mm thick rendering in CM 1:4 and pointed in colour cement to match the tiles complete all as specified and directed.
M&L for non - skid glazed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inluding 15mm thick cement screed bed in cm (1:6) complete all as specified and directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) over 15 mm thick cement screed 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
M&L for three coats of white wash on new plaster surfaces of ceiling including preparion of surfaces complete all as specified and directed.
M&L for two coats of white wash on old decorated surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L for two coat of oil bond distamper on wall surfaces over 1 mm thick wall care putty including preparation of surfaces complete all as specified and directed.
M&L for one coat of oil emulsion distemper on old decorated surfaces of wall surfaces including preparation of surfaces complete all as specified and directed.
M&L for two coats of cement base paint on newly plastered surfaces of wall over a coat of white wash including preparation of surface complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of weather proof exterior emulsion (APEX) on walls including preparation of surfaces complete all as specified and directed.
M&L for one coat of cement base paint on old decorated surfaces of walls including preparation of surfaces complete all as specified and directed.
S&F in repairs vitreous china, white, Indian type (Squatting pan) water closet Orissa pattern long pan size 580 mm x440mm with ‘P’ or ‘S’ trap, front or back with integral foot rests (excluding flushing cistern & flush pipe) and provision of lime concrete bedding complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan pedestal pattern white (excl fixing bolt flushing cistern and flush pipe ) with seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminum hinging device complete all as specified and directed.
S&F in repair white vitreous China (flat back) wash hand basin 400x550mm size, incl cutting for and pinning in ends of bracket, fixing all connected items like 01 No CP pillar cock, 01 No CP waste coupling, 01 No PVC waste pipe, 01 No 450 mm long PVC connection and CI brackets complete all as specified and directed. NOTE : Cost of connected items shall deemed to be included in quoted rates.
S&F in repairs PVC low level flushing cistern 10 liters capacity with fixtures and fittings including flush pipe, PVC connection, complete all as specified and directed.
S&F in repairs 15 mm bore cast copper alloy bib taps, with crutch or butter fly handle, screwed down, screwed for iron pipes or for brass unions complete all as specified and directed.
S&F in repair 15 mm bore stop/angle valves, cast copper alloy with crutch or butter fly handle, high pressure, screwed down, screwed both ends for iron pipe or for brass ferrule complete all as specified and directed.
Taking up/down 15mm bore GI tubing and connections including cleaning for refixing etc. complete all as specified and directed.
Taking up/down 20mm bore GI tubing and connections including cleaning for refixing etc. complete all as specified and directed.
S&F GI tubing 15mm bore, medium grade fixed to wall/ceiling etc. or laid on floors complete all as specified and directed.
S&F GI tubing 20mm bore, medium grade fixed to wall/ceiling etc. or laid on floors complete all as specified and directed.
Refixing old steel water tubing 15mm dia with using new GI fittings and connected to new or old positions of walls, ceilings, floors etc complete all as specified and directed.
Refixing old steel water tubing 20mm dia with using new GI fittings and connected to new or old positions of walls, ceilings, floors etc complete all as specified and directed.
S&F in repair PVC connection 15mm size with PTMT nuts,450mm long complete all as specified and directed.
S&F in repair looking mirror 5mm thick of size 600x450mm beveled edges with chromium plated bracket guard mounted on 6mm thick AC bldg board or commercial plywood fixed to wooden plugs with CP screws and cup washer complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) Floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed.
S& F in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed.
S&F in repair 25mm dia decorative powder coated drapery rod, colour as approved with seasoned teak wood rings and brackets, fix to wall concrete complete all as specified and directed.
Demoition of reinforced cement concrete of any description complete all as specified and directed. (Reinforcement cut as required to facilitate demolition).
S&F sand stone slabs 5CM thick as in sun shades, chhajas, shelves, landings cover stone etc n.exc 2mtr in length set in pointed in cement mortal 1:4 complete all as specified and directed.
M&L for mild steel angle iron gate,post, strut, MS rod with angle iron, FI gussete plate, pintal, hinges, sliding bolt, locking arrangement etc complete all as specified and directed.
S & F in repair 3 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) as in concrete bed to drain pipe 150mm bore incl packing under and haunching against the side of pipe after they are laid and tested complete all as specified and directed.
M&L for 150mm internal dia salt glazed stone ware drain pipes laid in trenches and jointed all as specified
M&L for cutting into existing manhole for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) smooth finished & reforming benching as required for 150mm borer pipe complete all as specified directed.
M&L for providing pre cast cement concrete 1:2:4 type B1 ( using 20mm graded stone aggregate) as in manholes covers and set in CM 1:6 complete all as specified directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified directed.
S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified directed.
S&F in repair mild steel wire cloth 0.56mm nominal dia of wire and avg width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
Dismantling PVC water tank and removing from site capacity in ltrs exc 500 ltrs but n. exc size 1000 ltrs complete all as specified directed.
S&F 500 Ltrs capacity Rotational molded polythylene water storage tank (cylindrical vertical with closed top) ISI Marked hoisted and fixed in position, complete all as specified and directed.
S&F ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed for 20mm bore pipe complete all as specified and directed
S& F in repair mild steel windows with side hung shutters incl box type hinges with Z section handle and steel peg stay with glazing bars, dovetained or welded omplete all as specified and directed
S&F in repair steel windows with side hung shutters incl box type hinges with Z section handle and steel peg stay without glazing bars, dovetained or welded complete all as specified and directed
S&F mild steel wire cloth 0.56mm nominal dia of wire and avg width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or beads in square not exc 0.50 sqm in each pane, complete all as specified and directed.
M&L for two coats of synthetic enamel paint over one coat of red oxide primer on steel surfaces exc 10cm width or girth including preparation of steel surfaces, complete all as specified and directed
Providing water proofing treatment over RCC roof including projection as follows :- (a) Complete removal of existing roof treatment of any description and in any position (b) The slab shall be finished with 10mm thick cement plaster in cement mortar 1:4 finished even and smoooth (without using extra cement) mixed with water proofing compound as per manufacturer's instructions. (c) Apply a coat of bitumious primer conforming to IS-3384 @ 0.3 liter/Sqm on the prepared surface of plaster. After drying of primer, apply a coat of hot blown VG 20 paving grade (60-80 penetration) bitumen conforming to IS-702 @ 1.2 Kg/Sqm on plastered surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, end overlaps shall not be less than 150mm as side lap 75. Polymeric water proofing membrane should be with centre core as 90 microns high molecular high density polythylene film Minimum weight of water proofing membrane shall be 3Kg per Sqm.
(e) Over the polymeric water proofing membrane apply semi hot blown VG 20 paving grade (60-80 penetration) bitumen conforming to IS-702 @ 1.2 Kg/Sqm of roof surface and blinded with fine sand in dry condition @ 0.5 Kg/Sqm dusted over the bitumen coat (f) Covered fillet in PCC (1:2:4) type B-0 radius 75mm be provided at the junction of roof and vertical surface such as paraper wall/mumty/chimney around opening and treatment mentioned above except fine sand) shall be applied followed by a cement plaster 20mm thick in cement mortar (1:6). Complete treatment shall be carried out by the applicator of the manufacturer of membrane. (g) Provide PCC padding 1:2:4 type B-0 of uniform thickness of 50mm in two layers of 25mm thickness each with chicken wire mesh 0.90mm dia and 12mmx12mm aperture, laid between two layers. Top surface of PCC padding shall be finished even and smooth without using extra cement and 12mmx12mm aperture with flase groove and 300x330mm centre to centre.
S&F Pressed steel door frame of size 105x60 mm with one or more rebates incl necessary fixing lugs, hinges, lock & strike plate etc. complete all as specified and directed
S&F Pressed steel door frame of size 125x60 mm with one or more rebates incl necessary fixing lugs, hinges, lock & strike plate etc complete all as specified and directed.
M&L providing PCC 1:2:4 type B-1( using 20mm graded aggregate) as in coping, beanching, hold fast, water troughs and the like including weathering, slightly arounded or chamfered anagle and throating complete all as specified and directed.
M&L for PCC 1:3:6 Type C-1 ( using 20mm graded aggregate)as in back filling of pressed steel door frames complete all as specified and directed.
M&L for 30 mm thick flush shutters ,solid core construction ,with block board core and plywood face panels ,commercial type on both side complete all as specified and directed.
S&F 35mm thick second class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauge etc (without sash bars) edges of the framing plain, chamfered rounded, fitted with cut & mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, section 8 clause 8.20 (a) supplied and fitted to chowkats complete all as specified and directed.
S&F 150mm extruded alumiium alloy handles, fabricated anodised complete all as specified and directed.
S&F 150mm aluminium anodized barrel tower bolts, complete all as specified and directed.
S&F 250mm aluminium alloy anodised sliding door bolts with hasp and staple (bolt type) and fixing clips of sheets cast or extruded sections and fixing bolts and sliding bolts or extruded section of cast alum alloy and fixed complete all as specified and directed.
S & F 300 mm MS ordinary rat tail spring including roller and roller plate complete all as specified and directed.
S & F 100 mm long Butt hinges, medium weight cold rolled mild steel, and fixed complete all as specified and directed.
S&F framed work such as grills, gratings etc with ends of bars shouldered and guard bars and similar work conforming to Fe-290 Gde E-165. complete all as specified and directed.
S&F in repair CP aluminium andised towel rail 20 mm dia D type ,60mm long between flanges complete all as specified and directed.
S&F in repair stainless steel sink with draining board, made out of 1.00 mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repair stainless steel plate rack fixed on wall etc complete, made out of 1.00 mm thick of over all size 0.75x0.75M with shelves and racks complete all as specified and directed.
Providing water proofing treatment to sunken floor of bath/WC/Toilet/Lobby/ Passage/ Ground sunk/ Kitchen/Lavs and any other sunken slabs as specified here-in-below:- (a) Complete removable of executing treatment of any description. (b) Providing coved angle fillet 75mm in radius in PCC (1:2:4) at the junction of wall and slab to permit smooth turning up of polymeric water proofing membrane. (c) Rendering sides of walls coming in contact with membrane, 15mm thick in cement mortar 1:4 mixed with water proofing compound in the propration as specified by the manufacture. (d) Cleaning the slab surface of all the dust with wire brush. (e) Applying bituminous primer conforming to IS-3384 applied @ 0.7Ltrs/Sqm of walls and slab and applying a coat of hot blown 85/25 Grade bituminous @ 1.20 Kg/Sqm after the primer has dried.
(f) Provide polymeric water proofing membrane ISI marked laid with over laps bonded with cold cut back adhesive, over lap shall not be less than 150mm. Over the water proofing membrane apply semi hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm of surface. (g) The sunken slab shall be given 1:40 slope towards outer wall and slab surface shall be plastered in cement mortar (1:3) with water repellent finishes using repellent S-101 with minimum 10mm thick given in proper slope towards outlet pipe.
M&L for PCC 1:5:10 Type E-2, (40 mm graded stone aggregate as in filling and mass concrete in sunken floors complete all as specified and directed.
M&Lfor mild steel TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spiraly hooping ends binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F Precast RCC manholes cover slab grade M-25 (Nominal mix) (using 20mm graded crushed stone agg), set in cement mortar 1:6 incl necessary form work complete all as specified and directed.
Demolition of reinforced concrete in ground floor and paving n.exc 15cm th (below or above ground level) including removal of rubbish from site complete all as specified and directed.
Excavating in trenches, in soft / loose soil n.exc1.5m wide and n.exc 1.5m depth; for fdn etc,or for shafts wells cespits, manholes pier holes etc; n.exc 10 sqm on plan and getting out complete all as specifide and directed
Returning filling in and including spreading excavated earth into trenches around pipe etc after laying of pipes etc and testing complete incl leveling, watering and welll ramming in layers n,exc 25cm layers complete all as specified and directed.
Removal of surplus excavated material soil to a distance n'exc 50m and depositing where directed at a level n'exc 1.50m above the starting point complete all as specified and directed.
Demolition of stone/Brick masonry built in Cement mortar incl all quions,Arches complete all as specified and directed.
M&L for Brick work with sub class B old size bricks ( best quality) straight or curved on plan exc 6 M mean radius built in CM 1:4 and complete all as specified and directed.
M&L for Brick work (Except brick) with sub class B old size bricks (best quality) straight or curved on plan exc 6 M mean radius built in CM 1:4 and complete all as specified NOTE : Bricks obtained from item No. 87 above shall be used
S&F welded steel wire fabric , weight n'exc 4 Kg per Sq.m as in extra reinforcement to RCC menbers including all cutting, bending and binding complete all as specified and directed
Dismantling, taking out & removing existing unserviceable plaster, loose/ unsound weaken cement concerete etc and M&L for applying one coat of epoxy resin (FAIR BOND EP FAIR BOND EP of Fairmate Constructions Chemical or equivalent as approved by GE) on old concrete surfaces of ceiling and beams, chhajja, stair case etc. @ 0.30 Kg/Sqm including preparation of surfaces as per manufacturer's instructions complete and applying 25mm thick (average thickness) of cement and sand (Fine grit) in ratio 1:3 mixed with chloride free spray concrete plastriciser (Spray crete or equivalent as approved by GE) as per manufacture instruction with guiniting machine of presser capacity not less than 5 Kg per sqcm and finished the surfaces even and smooth complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for machine pressed precast conctete interlocking paver block rubber mould any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment over 25mm thick sand cussioning complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers under layer 12 mm thick cement plaster 1:4 (1 cement 4 coarse sand furrowing the under layer with scratching tool applying cement slurry on the layer @ 3 Kg of cement plaster 1:1/2:2 ( 1 cement 1/2 coarse sand :2 stone chipping 10mm nominal size ) in panels with groove all around as per approved pattern incl. scrcbbing and washing the top layer with brushes and water to expose the stone chippings complete all as specified and directed. (providing of grooves shall be measured and paid separately under respective item)
M&L for forming groove of uniform size 15mm wide and 15 deep in the top layer of washed stone girthplaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens repair tothe edges of panes and finishing the groove complete all as specified and directed.
S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane
S&F in repairs mild steel wire cloth 0.56mm nominal dia of wire and avg width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No-99 above but for one socket outlet 5/6 Amps on independent bd controlled by one switch complete all as specified & directed.
All as per item No-99 above but for one socket outlet 5/6 Amps controlled by one switch on same board with other switches complete all as specified & directed.
All as per item No-99 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTEs for item no 99 to102 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators, lamp holders,light foittings shall be measured and paid for separately under appropriate item of BOQ. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B), however minimum size of conduit shall be 20 mm dia (medium grade)
All as per item No-99 here in before but one light point controlled by two nos 2 way switchs complete all as specified & directed.
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed.
S&F switch, bell push button, single pole, 5/6 Amps, one way, 230 Volts complete all as specified and directed.
S & F switch piano, flush type single pole, two way 5 Amp 230 volts complete all as specified and directed.
Supply and fix switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed.
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed.
Supply and fix socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed
Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed.
Supply & fix rotory stepped type electronic fan regulator mini flush type 100 watt 230 Volts complete all as specified & directed.
Supply & fix surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed.
Supply & fix surface mounting type bulkhead 10 watt LED luminaire ENDURA RUGBY NEO IP 65 environmental friendly, altra modern energy saving , decorative oval comprising of high brightness LEDs, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
Supply & fix in replacement, outdoor street light LED 35 watt luminaire IP 65/66 protection polyster powder coated with extruded grey aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor complete all as specified & directed..
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces complete all as specified & directed.
Supply and fix MCB DB 4 way sheet metal enclosure triple pole and neutral 415 volts with 100 Amp standard copper bus bar IP-43, IK-09 with metal doors of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type double door factory fabricated complete as per IEC 61439-3 without MCB but with enclosue blank plate complete all as specified and directed .
Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doorscomplete all as specified and directed.
Supply & fix Isolator TPN, 4 Pole, 415 Volts, 50 Hz AC Supply , 100 Amps, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed.
Supply & fix MCB SP, 40 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
Supply & fix Isolator SPN , 40 Amps, 240 volts, 50Hz, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed.
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1.
S&F iron metal body heavy duty exhaust fan 300mm sweep, double ball bearing, copper wound, with louvers, 230 volts, 50 Hz, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed.
M/s Sharda Costruction Company
M/S APOORVA CONSTRUCTION
M/s S. K. Construction Co.
VISHESH BUILDERS
M/s Salim Mohomad
Attar Singh and Sons
3Krishna Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .