Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | L1 | Accepted-AOC Deducts after sch of credit | |
| 2 | L2₹7.2 L+₹15,186.50 (2.15%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹8.0 L+₹97,131 (13.7%)Rejected-Finance 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹8.1 L+₹1.0 L (14.7%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹8.3 L+₹1.3 L (18.0%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
28 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Nagtalao
Military Engineer Services AGE I Nagtalao Pin 900120 CO 56 APO
Day to day maintenance of Electrical fittings and other connected works in Md Accn and surrounding Area in Nagtalao Area under AGE I Nagtalao
2020_MES_359164_1
8129/20-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Nagtalao
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I Nagtalao
₹19,800
Yes
21 May 2021
9 Jul 2020
30 Jul 2020
9 Jul 2020
28 Jul 2020
16 Jul 2020
60 days
Amount
Taking down carefully aluminium/ copper point wiring for light/fan/ socket/bell or power point incl. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete removing materials to store for keeping in safe custody for re-use at site or handed over to contractor as schedule of credit and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge.
M&L for point wiring with 1.5 Sq mm single core multi-stranded copper conductor PVC (FRLS) insulated, sheated cable 1100 volt grade in PVC casing capping 25 mm wide (ISI marked) with accessories fixed to surface of wall/ceiling with PVC sleeves as per relevant IS excluding pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.50 Sqmm single core, multi stranded copper conductor, PVC insulated, unsheated cable for common earth and connecting for earth dolly for :- (a) One light/fan exhausrt fan point controlled by one, one way switch.
(b) One socket outlet 3 pin 5 Amp on independent board.
All as per Item No 2 above but with 2.5 Sqmm single core multistranded copper conductor cable for 6 pin 15 Amp socket outlet on independent board
S&F in repair switch piano flush type 5 Amp 240 Volts single one way (ISI marked) complete all as directed by Engineer-in-Charge.
S&F in repair Switch flush type 5 Amp single pole two way.(ISI marked) complete all as directed by Engineer-in-Charge.
S&F in repair switch piano flush type 15 Amp 240 Volts single pole one way (ISI marked) complete all as directed by Engineer-in-Charge.
S&F in repair Socket outlet 3 Pin 5 Amp flush type 240 volts (ISI marked) complete all as directed by Engineer-in-Charge.
S&F in repair socket outlet 2 in 1, 3 Pin, 5 & 15 Amp flush type 240 volts (ISI marked) complete all as directed by Engineer-in-Charge.
S&F in repair switch socket combination 2 in 1, 3 Pin, 5 Amp flush type with shutters 240 volts (ISI marked) complete all as directed by Engineer-in-Charge.
S&F in repair switch socket combination 2 in 1, 3 Pin, 5 & 15 Amp flush type with shutters 240 volts (ISI marked) complete all as directed by Engineer-in-Charge.
S&F in repair modular switch 1 way, 6 Amp, 1 module, 240 Volts (ISI marked) complete all as directed by Engineer-in-Charge.
S&F in repair modular switch 1 way, 16 Amp, 1 module, 240 Volts (ISI marked) complete all as directed by Engineer-in-Charge.
S&F in repair modular socket 1 way, 6 Amp, 2/3 pin, combined 2 module, 240 Volts (ISI marked) complete all as directed by Engineer-in-Charge.
S&F in repair modular socket 1 way, 6/16 Amp, 2/3 pin, combined 2 module, 240 Volts (ISI marked) complete all as directed by Engineer-in-Charge.
S & F in repairs Bell push switch flush type 5 Amp 240 volt (ISI marked) complete all as directed by Engineer-in-Charge.
S & F in repairs Modular Bell push switch flush type 5 Amp 240 volt (ISI marked) complete all as directed by Engineer-in-Charge.
S & F in repairs Bell, AC. 230 V, single pole (ISI marked) complete all as directed by Engr-in-Charge
S&F in repair Ceiling rose, surface backlite 65 x 50mm thick two to three terminals for Fan, Tubelight (ISI marked) complete all as directed by Engr-in-Charge
S&F in repair electronic stepped type fan regulator flush type suitable for ceiling fan (ISI marked) complete all as directed by Engr-in-Charge
Supply and fix in repair White cover plate with frame ISI Marked. complete all as specified and directed by EIC. (a) 3 Module
(b) 4 Module
(c) 6 Module
(d) 8 Module
Supply and fix in repair Modular metal flush box ISI Marked. complete all as specified and directed by EIC. (a) 3 Module
(b) 4 Module
(c) 6 Module
(d) 8 Module
Supply and fix in repairs phenolic laminated sheet wooden board of following size with cutting for switch and socket etc as reqd incl suitable size 4 nos machinig screw with washers complete all as per directed by Engr-in-Charge. (a) 4"x4"
Supply and fix in repairs phenolic laminated sheet of following size with cutting for switch and socket etc as reqd incl suitable size 4 nos maching screw with washers complete all as per directed by Engr-in-Charge. (a) 4"x4"
Fixing only in repair LED tube rod/fitting of capacity 18/20/22 W as per site requirement all as apecified and directed by Engr-in-Charge.
Fixing only in repairs MCB SPN 20 Amp 240 Volts complete all as per directed by Engr-in-Charge.
Fixing only in repairs MCB SP 10 Amp 240 Volts complete all as per directed by Engr-in-Charge.
Fixing only in repairs MCB 40 Amps SPN complete all as per directed by Engr-in-Charge. (NOTE: Item no 35 to 38 will be supplied under Sch 'B' free for fixing)
S & F in repairs SPN DB's, 240 V, double door 200 amps rated bus bar complete all as per directed by Engr-in-Charge. (a) 12 way
S & F in repairs 4 way TPN DB, 415 V, double door 200 amps rated bus bar complete all as per directed by Engr-in-Charge.
S & F in repairs 4 way VTPN DB, 415 V, double door 200 amps rated bus bar, including 100 Amps 4 pole, 16 KA MCCB complete all as per directed by Engr-in-Charge.
S & F in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as per directed by Engr-in-Charge.
S & F in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 Amp complete all as per directed by Engr-in-Charge.
S & F in repairs Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amp complete all as per directed by Engr-in-Charge.
S & F in repairs for Sub main wiring with single core FRLS PVC insulated and unsheathed multistranded, copper conductor cable 1100 volts grade drawn through and incl 20 mm size of of PVC conduit accessories and fittings. Cable required for connection to DBs shall deemed to be including and shall not be measured separately. Earth wire shall run inside the conduit. (a) 02 runs 6 sqmm conductor cable and 01 run of 6 sqmm as earth continuity conductor.
(b) 02 runs 4 sqmm conductor cable and 01 run of 4 sqmm as earth continuity conductor.
(c) 02 runs 2.5 sqmm conductor cable and 01 run of 2.5 sqmm as earth continuity conductor.
S & F in repairs condenser 240 volts 2 MFD heavy duty suitable for ceiling fan incl testing ISI marked. Make: Efcos
S & F in repairs condenser 240 volts 2.5 MFD heavy duty suitable for exhaust fan incl testing ISI marked. Make: Efcos
S & F in repairs condenser 240 volts 3 MFD heavy duty suitable for ceiling fan incl testing ISI marked. Make: Efcos
S & F in repairs condenser 240 volts 4 MFD heavy duty suitable for exhaust fan incl testing ISI marked. Make: Efcos
S & F in repairs Batten/Angle Holder for fixing bulbs complete all as per directed by Engr-in-Charge.
Supply and fix in repair square shaped surface mounted 6w LED slim panel with PMMA diffuser, powder coated white finish housing Cromption cat No LCDSPLN-S-06-CDL complete all as directed by Engr-in-charge. Make- Philips/GE
Supply and fix in repair round shaped surface mounted 6w LED slim panel with PMMA diffuser, powder coated white finish housing Cromption cat No LCDSPLN-R-06-CDL complete all as directed. Make- Philips/GE
Replacement/Repairs no electric supply/no water supply complaint including cheking of MCB, DB,LED bulb/Tube rod, fuse & isolators, wiring, GI piping connection and start elctric/water Supply complete all as directed by Engr-in-charge. (Note 1:- Change of MCB's, DB, Fuse, Isolator, GI pipe items shall be paid in appropriate item. Note 2:- The contractor will appoint one electrician, one plumber and one helper on each working day of office to attend the complaint. Note 3:- Contractor will supply or provide PVC tape roll as required for rectify the complaint.)
Supply and fix in repair GI Tubes medium grade 25 mm dia duly ISI marked including all type of fittings complete all as directed by Engr-in-charge.
Supply and fix in repair GI Tubes medium grade 20 mm dia duly ISI marked including all type of fittings complete all as directed by Engr-in-charge.
Supply and fix in repair GI Tubes medium grade 15 mm dia duly ISI marked including all type of fittings complete all as directed by Engr-in-charge.
Supply and fix in repair Gun metal Globe / Gate valve with Iron wheel head screwed both ends for iron pipes of 20 mm bore dia ISI marked complete all as directed by Engr-in-charge.
Supply and fix in repair Gun metal Globe / Gate valve with Iron wheel head screwed both ends for iron pipes of 25 mm bore dia ISI marked complete all as directed by Engr-in-charge.
Supply and fix in repair Supply only Ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, 20 mm dia complete all as directed by Engr-in-charge.
Supply and fix in repair Supply only Ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, 25 mm dia complete all as directed by Engr-in-charge.
Supply and fix in repair of following undermentioned items for Plumbing work in the existing GI pipes complete all as directed by Engr-in-charge. (a) GI Socket 20 mm dia ISI marked
(b) GI Socket 25 mm dia ISI marked
(c ) GI Nipple 20mm dia and 200 mm length ISI marked
(d) GI Nipple 25mm dia and 150 mm length ISI marked
(e) MS Plug 20 mm dia ISI marked
(f) GI Reducer Socket 20X15 mm ISI marked
(g) GI Reducer Socket 25X15 mm ISI marked
(h) GI Reducer Socket 25X20 mm ISI marked
(j) GI Elbow 20 mm dia ISI marked
(k) GI Union 20 mm dia both end screwed ISI marked
(l) GI Union 25 mm dia both end screwed ISI marked
Material & Labour for taking down Electromechanical Boom Barrier from existing location and transportion to contractor workshop dismantle in to parts for repair / replacement/ thoroughly cleaning of parts & reassembling all parts of boom barrier as work wise. Taking back at the existing location & re-erect the same at site after completion of repairing work. Note :- Testing of boom barrier up to entire satisfaction of AGE(I) Nagtalao. Make :- Godrej
Repairing & Servicing internal tank in capsulated in weather proof oil filled chamber including replacement of gears, connecting shaft, crank and hydraulic pump motor , repairing of transformer, general wiring and cabling including replacement of UNSV optical sensor , Remote cells as per esxisting make and size.
Material & labour for repairing to microprocessor based electronic control panel including replacement of PCB as per existing make & size.
S & F in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3/3.5 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm by providing cable fault locator and rectify the fault and restore electric supply complete all as directed by Engr-in-charge.
S & F in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3/3.5 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm by providing cable fault locator and rectify the fault and restore electric supply complete all as directed by Engr-in-charge.
S & F in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3/3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm by providing cable fault locator and rectify the fault and restore electric supply complete all as directed by Engr-in-charge.
Dwarka Enterprises
DIWAKAR CONSTRUCTION CO.
Siddharth Constructions
Shri Electrical Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .