Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
1 Jun 2020, 6:00 pmClosed
GE (AF) GORAKHPUR
GORAKHPUR-273008
REPAIR/MAINT OF COOLING APPLIANCES, WINDOW AC, SPLIT AC, REFRIGERATOR, WATER COOLER AND ALLIED WORKS ETC AT AF STN GORAKHPUR
2020_MES_335568_2
8670/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) GORAKHPUR
Please refer Tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) GORAKHPUR
₹30,000
Yes
26 Jun 2020
20 May 2020
3 Jun 2020
20 May 2020
1 Jun 2020
20 May 2020
Amount
Maint of window type AC of Capacity 1.5 ton any make/ model including removing the AC and cleaning ,Oiling, servicing and checking for proper functioning and re-fixing at site complete all as specified and directed Note:- Spare parts will be measured and paid separetly
All as per item above but split type AC 1.5 Ton
All as per item above but split type AC 2.00 Ton
Checking of unserviceable Window/split AC/Water Cooler/ Desert Cooler unserviceable parts likewise relay, compressor, blade, motor, gas leakage, condensor coil, capacitor, Thermostate, Filter, PCB, Wiring etc all mechanical accessories in day to day and making it serviceable in all respect with all replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check leakage & removal in window/splitAC /water cooler/ Deep freezer as and when directed. The scope also include complete checking of window/split/summer Appliances. Note:-(a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs (b) The contractor or his representative will take complaint from MES complaint Register through MES job card (c)The contractor will made seprate items register with location and signature of user (d) The contractor will maintain complete detail of JOB card and items involved with date and user signature (e) The ladder and T&P as required will be provided by the contractor (f) Risk Factor will be the contractor 's end and safely measures shall be adopted as per norms.
Dismantling of window/Split type 1.5 Ton Air conditioner and replacing the burnt sealed compressor (Rotary Type) unit incl all other works such as cleaning and Gas charging and re-fixing at site complete all as specified and directed.
Supply only in replacement of new condenser coil for 1.5 Ton Window type AC etc complete all as specified and directed.
Supply only in replacement of new relay for 1.5 ton Window/split type Air Condition complete all as specified and directed(Make:- microtech/renutron)
Supply only in replacement of new over load protector 1.5 ton Air Conditioning complete all as specified and directed(Make:- microtech/renutron)
Supply only in replacement of new starting capacitor 100-120 MFD, suitable for window/ Split type AC 1.5 Ton complete all as specified and directed Make:- teslla/Asian
Supply only in replacement of new running capacitor, 36 MFD, suitable for 1.5 ton Air Condition complete all as specified and directed Make:- LG/Voltas/Carrier)
All as above but 45 MFD(Make:- LG/Voltas/Carrier)
Supply only in replacement of new thermostatic switch, suitable for 1.5 ton AC complete all as specified and directed
Supply only new Air filter for window type AC 1.5 Ton complete all as specified and directed (Make:- LG/Voltas/Carrier)
All as above but for 2 Ton
Supplly only new Air filter for spilit type AC 1.5 Ton complete all as specified and directed (Make:- LG/Voltas/Carrier)
All as above but for 2 Ton
Taking down electronic remote circuit board (PCB) of window /split type AC 1.5/2 ton repairs and fix complete all as specified and directed
Supply only electronic remote circuit board (PCB) of Air window/split type AC 1.5/2 ton complete all as specified and directed
Supply only in replacement of new wiring kit for window type AC 1.5 Ton capacity complete all as specified and directed
Supply only in replacement of new capacitor 4/6 MFD complete all as specified and directed.
M & L for rewinding of blower motor for 1.5 ton AC with superior quality of super enameled copper conductor of appropriate sizes in existing weight and gauge incl replacement of Bush/Bearing, commissioning and testing complete all as specified and directed.
All as per item above but inner unit of split AC of Split type.
Supply only Blower motor for inner unit of 1.5 ton AC with superior quality of copper conductor as per sample commissioning and testing complete all as specified and directed
Supply only fan motor for outer unit of 1.5 ton AC with superior quality of copper conductor as per sample commissioning and testing complete all as specified and directed
M & L for gas charging in window type AC unit 1.5 ton capacity using refrigerant gas as per standard practice after flushing, vacuuming incl detecting leakage, rectification of leakage, commissioning and testing upto sufficent pressure complete all as specified and directed
All as above but for 2 Ton
All as per above item but in split type AC 1.5 ton capacity
All as per above item but in split type AC 2 ton capacity
S & F in replacement of sheet metal enclosure with two pin metal plug with MCB suitable for 1.5 Ton/2 Ton AC ,230 volts complete all as specified and directed .(Make:-Indoasian/legrand/Havells)
S & F in replacement of copper tubing 1/2" heavy duty complete all as specified and directed
S & F in replacement of copper tubing 1/4" heavy duty complete all as specified and directed
S & F in replacement of copper tubing 5/8" heavy duty complete all as specified and directed
S & F in replacement of PVC insulated & sheathed flexible 3 core copper cable of 4 Sqm complete all as specified and directed
S & F in replacement of PVC insulated & sheathed flexible 3 core copper cable of 6 Sqmm complete all as specified and directed
Supply only in replacement of new remote control for split/window type AC 1.5 ton/2 ton capacity with battery complete all as specified and directed
S & F in replacement of new brasmetic hand shut off valve for split type AC complete all as specified and directed
Installatoin /Re-installation only split tye Air conditioning electrically driven ,230/250V ,AC 50 Hz capacity 1.5/2.0 Ton with high wall mounted type fan coil unit (FCU) to be fitted in wall with rowl plugs including making holes for inlet /outlet in the wall and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer all as spcified
Supply and fixing in replacement of new auto swing motor for window/split type AC 1.5 TON/2 TON all as spcified.
Making of angle iron frame for installation of split type AC outer unit 40x40x4 mm having height from GL of as per outer size of AC with necessary bldng grouting all as specified
Supply and fixing Fan Blower set for 1.5 Ton Split type AC (as per sample) complete all as spcified and directed
M & L for replacement of unserviceable sealed unit of water coolers with reconditioned sealed unit (directly repaired by manufacturer) sealed unit for following size of water coolers complete all as specified and directed Note(:old sealed unit should be property of contractor)(Make:- kirloskar/tecumsaw) (a) 200 SF
(b) All as above but for 300 SF
Supply only relay assembly, suitable for following make of water coolers complete all as specified and directed(Make:- Microtech/sriram/Usha (a) 300 SF
(b) All as above but for 200 SF
Supply only over load protector complete in all respect suitable for following models of water coolers complete all as specified and directed(Make:- kiroskar/tecumsa) (a) 300 SF (Storage Capacity-60 Litre)
(b) All as above but for 200 SF (Storage Capacity-40 Litre)
Supply only new starting capacitor for following make of water coolers complete all as specified and directed Make Usha/Teslla /Universal/ Blue star/Sri Ram (a) 300 SF
(b) All as above but for 200 SF
Supply only in repair new running capacitor for following make of water coolers complete all as specified and directed Make (a) 300 SF, Sri Ram Gulmerg/Electronic/Blue star/Usha
(b) All as above but for 200 SF
S & F in replacement of new thermostatic switch, suitable for water coolers complete all as specified and directed . (Make: Indfoss) or its equivalent
S & F in replacement of new Chromium plated push cock, self closing, spring loaded type 15 mm dia, with water waste tray for water coolers complete all as specified and directed.
M & L for gas charging in water coolers by using refrigerant as per standard practice after proper flushing vacuuming detecting leakage, commissioning and testing complete for following size of water coolers complete all as specified and directed. (a) 300 SF make Gulmerg/Electronic/Blue star/Usha/Sri Ram
(b) All as above but for 200 SF
M & L Repair to Refrigerators complete by cleaning of system properly with CTC, charging refrigerant including replacement of unserviceable sealed unit (Compressor) of refrigerator with reconditioned sealed unit, directly repaired by manufacturer complete all as specified and directed(Make:- kirloskar/tecumsaw) Note(:old sealed unit should be property of contractor) (a) 165 to 190 Ltrs capacity.
(b) All as above but for 210 to 315 Litre capacity
Supply and fixing in replacement of new of box type relay for any make and capacity of refrigerator. Make Microtech/Renutrol
S & F against replacement condenser coil for the following capacity of refrigerator: (a) 165 to 190 Litres capacity.
(b) All as above but for 210 to 315 Litres capacity
S & F against replacement condenser coil for the following capacity for water coolers make Usha /Teslla/ Universal/Blue Star : (a) 310 SF
(b) All as above but for 200 SF
M & L for gas charging in Refrigerator by using refrigerant as per standard practice after proper flushing vacuuming detecting leakage, commissioning and testing complete for following size of Refrigerators complete all as specified and directed (a) capacity 165 Litres to 185 Litres
(b) All as above but for capacity 210 Litres to 310 Litres
(c) All as same but for Deep Frigers 180 to 310 Litres
S & F in replacement of new vertical water lifting pump, single phase, 1/7 HP or any HP suitable for desert coolers complete in all respect. (Make : summerking/Summer cool /MEI/Crompton
S & F in replacement of new fan motor 1/7 HP or any HP 230V, 50 Hz cycles A/C supply complete in all respects complete all as specified and directed. (Make : summerking/Summer cool /MEI/Cromptonsummerking)
Supply and fixing wood wool pad for desert cooler of suitable size with connected acces. (one set of 3 Nos)
M & L for rewinding of main transformer of voltage stablizer using supirior quality of super enameled copper of core matching size complete with varnising dying and re-fitment in stablizer complete all as specified and directed (a) 5 KVA
(b) All as above but for 4 KVA
S & F in replacement of new PCB matching size of voltage stablizer 4KVA of single phase operation in AC supply complete all as specified and directed
All as above but for 5 KVA
S & F in replacement of new of TDR for voltage stablizer 4 KVA complete all as specified and directed.
All as above but for 5 KVA
S & F in replacement of voltmeter 0-300 volt for voltage stablizer 4 KVA complete all as specified and directed.
All as above but for 5 KVA
S & F in replacement of new of MCB SP 20A for voltage stablizer 4 KVA complete all as specified and directed.
All as above but for 5 KVA
Supply and fixing in replacement of new of thermostate for any make and capacity of refrigerator. Make Microtech/Renutrol/Denfost
S&F switch Assembly 5A as per sample complete all as spcified and directed
S&F Plugtop 15A as per sample complete all as spcified and directed
S&F Push cock CP 15 mm dia for water cooler complete all as spcified and directed
Painting of water cooler/ Desert Cooler in two coat of synthetic enamel paint complete all as spcified and directed
Sanjai sales and services
Vijay Electricals
Instrumentation and Electric Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .