EE_I, South Kol. Health El. Divn., P.W.Dte
75 D H Road Kidderpore Kol_23
Special renovation and remodelling of administrative Building within the campus of IPGMER_Electrical Installation work and other utility service-SITC of Fire Detection system.
2019_WBPWD_234917_1
WBPWD/SKHED/Q71/18-19(3rd Call)
Open Tender
FIRE FIGHTING ORG
Item Wise
15 days
Kolkata
Please refer Tender documents.
2 documents required · 2 mandatory
₹12,000
O/o Exe. Engr, South Kol. Health El. Divn. P.W.Dte
8 Feb 2021
25 Jul 2019
9 Aug 2019
25 Jul 2019
6 Aug 2019
2 Aug 2019
1 Aug 2019
Amount
Supply, Installation,Testing & Commisioning of Microprocessor based Intelligent, soft addressable, 2 Loops, expandable upto 4 Loops ( VDS / UL / FM / ULC approved ), ethernet ready fire alarm control panel, with each loop capable of taking minimum 120 devices. The panel shall be able to give pin point location of all fire/ fault conditions. The Panel should be able to store minimum 1000 log events in its Memory as per recommended standards. The panel should be compatible with existing Siemens make GUI system for controlling & monitoring all the devises of this BOQ, from the said GUI. Necessary h/w, s/w including interconnection & programming support should be provided by the bidder at no additional cost. Necessary OEM licensed software and / or dongle for programming (addition/alteration) of the Fire Alarm Control panel with lifetime validity has to be provided by the ‘L1’ bidder, before handover.
The panel shall have in-built rectifier, Loop cards, interface card for connecting external serial printer, 4 line, 40 charecter/line alphanumeric LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 2 hours during alarm condition, with integral battery charger complete as required. The panel shall have extra loop card to serve as stand by in case of burntout or malfunctioning of any operating loop cards. The FACP shall be capable of being networked with other similar FACP located at different part of the premises through ethernet (LAN). The panel should have necessary Ethernet card installed in it for bidirectional communication with 3rd party BMS/Scada and 3rd party public address system. All necessary memory map (incl. device address) should be provided. Minimum spare 4 potential free contacts should be provided with the panel. The system must be preloaded with licenced software. ( Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls ).
Supplying, installation, testing and commissioning of Intelligent soft Addressable multisensor detector with inbuilt optical smoke sensors as well as heat sensor (ROR+Fixed) with decentralise intelligence and inbuilt fault isolator complete with base and wiring as per NFPA style 7 as required (Approved standards: Vds & EN54 Standard; Approved Make: Honeywell-Esser/Siemens/BOSCH).
Supplying, installation, testing and commissioning of soft Addressable Heat Detector (Fixed temperature cum rate of rise) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for each addressable devices (Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost)...(Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Contros )
Supply, Installation,Testing & Commisioning of soft Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo/ Morley / System Sensor / Johnson Controls ).
Supply, Installation, Testing & Commissioning of soft Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base ( VDS / UL / FM / ULC approved) approved. (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls ).
Supply, Installation, Testing & Commissioning of soft Addressable transponder/ Monitor Modules (1 in and 1 out) ( VDS / UL / FM / ULC approved ) for monitoring flow switches/Fire exit doors / AHU / Lift etc complete as required. ( Approved Make: (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls ).
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc.( Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls ).
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / KEI ) with 20 mm NB PVC rigid conduit pipe(Make: Precisson-Medium) on the surface of the wall.
NOTE : 1. The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation.
TESTS:1.The system shall be tested and commissioned by a qualified competent,trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system under active monitoring of OEM. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done. Before taking up the work necessary drawing/layout should be prepared and must be approved from the fire safety Cell of PWD according to the prevailing fire safety policy. After commissioning, completion certification should be obtained from same Fire Safety Cell without which payment shold not be released.
The Agency must procure the materials from the Manufacturer/OEM or from their authorized sales channel so that the standard warranty/supprot of the Manufacturer/OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer/OEM or from their authorized sales channel and standard warranty/support should be sent from the e-mail of the Manufacturer/OEM/authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
Romeetech Engineering & Services
Office Automation Systems
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .