Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹28.9 L+₹26,510.45 (0.93%)Rejected-Finance HOUSE NO 03 RAGHAVPURAM MALL ROAD MORAR GWALIOR | GWALIOR | GWALIOR | MADHYA PRADESH | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹29.0 L+₹39,525.45 (1.38%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹29.9 L+₹1.3 L (4.64%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹30.1 L+₹1.5 L (5.31%)Rejected-Finance | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Jun 2023, 6:00 pmClosed
GE (AF) ADM AREA
GE (AF) ADM AREA GWALIOR-474020
REPAIR/MAINT OF PATH, HARD STANDING, DRAIN AND FENCING WORK IN OTM/MES COLONY AND CHETAK AREA UNDER GE (AF) ADM AREA AT AF STN GWALIOR
2023_MES_597756_1
8313/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) ADM AREA GWALIOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) ADM AREA
₹80,000
Yes
18 Aug 2023
23 May 2023
28 Jun 2023
23 May 2023
20 Jun 2023
6 Jun 2023
Amount
Demolition of PCC in ground floors and pavings not exc 15 cm thickness below or above ground level, complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n. exc 1.5 m in depth for foundation etc.and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m and n. exc 3m in depth; for shafts, wells,, man holes and for sewage lines and foundation etc.and getting out in soft/ loose soil n.exc 10 sqm in plan complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material soil exc. 250m but n exc 500 m & depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
Removing excavated material soil exc. 500m but n exc 1500 m & depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
M & L for plain cement concrete, 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in drains, sufaces channel complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concret using extra cement including forms, molds, mitred/stopped ends etc.
--Ditto-- all as per item No 9.00 here-in-before but Add or deduct for each 25 mm girth complete all as specified and directed.
M&L for PCC (1:2:4 )type B-1 using 20mm graded stone agg as in coping, kerbs, mud stops including weathering slightly rounded or chamfered angles & throating with and including necessary form work etc complete all as specified & directed.
M&L for PCC (1:3:6 )type C-2 using 400mm graded stone aggregate as in drain beds etc complete all as specified & directed.
Dismantling of wrought iron or mild steel work any description and fixed in any position complete all as specified and directed.
S & F of rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and includin
S & F 0.63mm thick plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) etc complete all as specified and directed
M & L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
Taking down cement / lime plaster on brick or concrete surfaces etc including racking out joint, hacking for key screbbing down with water etc.complete all as specified.
M&L for Rendering 15 mm thick on brick work or concrete surface on wall in cement mortar 1:4 finished even and smooth without using extra cement all as specified.
M&L for Rendering 15mm thick on brick work or concrete surface on wall in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 etc complete all as specified and directed.
~Ditto~ all as per srl item no. 21.00 here-in-before but (except brick) work built in CM (1:4) complete all as specified and directed.
S&F 50 mm thick Pre cast cement concrete jallies type B-0, 1:2:4 (12.5mm graded aggregate) set in cement mortar 1:4 including all mouldings, chamfers, weathering, throating etc complete all as specified and directed.
Formwork face of walls, parapets, coping, lintel beam, staircase and railing and similar work etc complete all as specified.
M & L for preparation of new plaster on brick wall surfaces and applying two coat of cement base paint over and including a coat of primer of on walls complete all as specified and directed
M & L for preparation of new plaster on brick wall surfaces and applying three coats of white wash complete all as specified and directed
M & L for preparation of new plaster surfaces of wall two coat of oil bound distemper over a coat of primer after applying 1mm thick putty complete all as specified and directed
Demolition of RCC work of any description and in any position etc complete all as specified and directed
M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or secure complete all as specified and directed
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or secure complete all as specified and directed
M&L for precast RCC 1:1.5:3 type B 1(using 20mm graded stone aggregates) as in landig, cover slabs and like for manhole/ drains, chullah hoods, chajjas, water trough shelves and similar articles complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in Concrete, brick work, masonry, etc. including taking out embedded portion and making good disturbed ground, complete all as specified and directed.
~Ditto~ all as per sl item No. 32.00 here-in-before but embedded on natural ground.
Dismantling fencing wire mesh,any type,complete all as specified and directed.
S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, running bars, for chain link fencing including embeding in concrete and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
Supply only MS screw, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exceeding 5cm and not exceeding 10cm long and dia of bolt etc, complete all as specified and directed
Supply only galvanised chain link fencing , size of aperture and dia of wire any size or type as approved GE complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire complete all as specified and directed
M&L for two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10cm width or girth.complete all as specified and directed
M&L for two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of old steel/iron surfaces exceeding 10cm width or girth.complete all as specified and directed
M&L two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces not exceeding 10cm width or girth.complete all as specified and directed
S&F in repairs galvanised 2 stand, steel barbed wire 2.24 mm dia barbed with 2mm dia bards at 75mm spacings and straining and fixing to any type of standerd rails straining bolts, including, seuring or tying at crossings with and provision of galvanised mild steel wire, staples etc. complete all as specified.
M&L for 25mm thick PCC 1:2:4 type B-O using 12.5 mm gradred stone aggregate as in flooring complete all as speicifed and directed
M&L for 75mm thick PCC 1:3:6 type C2 using 40 mm gradred stone aggregate as in path/plinth protection and like and finished even and smooth complete all as speicifed and directed
Dismantling floor hearth or wall tiling including cement mortar bedding & removing serviceable material to store and rubbish off the premises complete all as specified and directed.
M&L for chequred tiles of approved design,colour &of size 200mmx200mmx25mm set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles & includind 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed
M&L for endura designer tiles of size 300x300x10mm thick on terrace and path set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles & includind 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed
Demolition of stone slabs and tiles of any description or thickness in floors/kitchen platform, aprons etc complete all as specified and directed
M & L for 20 - 25 mm thick machine cut Kota stone slab as in flooring over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed
---ditto---- but in riser of steps, skirting, dado and pillar including redering in CM 1:4 complete all as specified and directed.
Dismantling existing sunken interlocking pavers block of any description, size and pattern complete all as specified and directed Note: Sand cushioning and sub base concrete shall be measured and paid separately
M&L for sand filling under floors or in foundation including and consolidation etc complete all as specified and directed.
M & L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thick, M-35 grade with grey cement and pigment laid in floor and joints of interlocking tiles/paver block to be filled with fine sand and broomed etc complete all as specified and directed.
All as per Item No 53.00 here-in-before but except paver blocks
M/s. Ravi and brothers
M/s Jai Durga Construction
M/S NIRMAL SINGH DHANJAL
MOHAN SINGH BHADORIA
GURU KIRTH BUILDERS
M/s Raaj Construction Co.
M/s Subhash Construction Co.
JNK BOND
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .