| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.7 LAccepted-AOC | ₹64.7 L Quoted ₹65.8 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹65.9 LRejected-Finance | ₹65.9 L | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹66.0 LRejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | ₹66.0 L | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹73.8 LRejected-Finance | ₹73.8 L | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/s Shri Inder Construction Company L3 | M/s Rashid Mohammed L2 | C K Industries L1 | M/S R.K. Builders & Developer L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of Stone slabs and tiles of any description or thickness in floors, walss, aprons etc., removing serviceable tiles to store and rubbish off the premises. | 52.5 | XSqm | 200 ₹10,500 | 200 ₹10,500 | 550 ₹28,875 | 250 ₹13,125 |
| 2.00 | Dismantling of floors health or walls tiling and Stone floor including cement mortar bedded (but not backing) & removing serviceable tiles to store and rubbies of the premises | 302.4 | Sqm | 30 ₹9,072 | 30 ₹9,072 | 55 ₹16,632 | 40 ₹12,096 |
| 3.00 | M&L for non skid ceramic coloured tiles of 7 to 8mm thick, (square/rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm , as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in CM (1:6) complete all as specified & directed by Engineer-in-charge. | 25 | Sqm | 1,050 ₹26,250 | 1,000 ₹25,000 | 975 ₹24,375 | 800 ₹20,000 |
| 4.00 | M&L for Non Skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm , over 15 mm thick screed bed in CM 1:4 in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and directed. | 45 | Sqm | 1,100 ₹49,500 | 1,200 ₹54,000 | 95 ₹4,275 | 1,000 ₹45,000 |
| 5.00 | M&L for Vitrified ceramic tiles, Light Shade 10mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white or colour cement to match with and including provision of 15 mm thick screed bedding in CM (1:6), complete all as specified and directed. | 134 | Sqm | 1,050 ₹1.4 L | 1,100 ₹1.5 L | 1,250 ₹1.7 L | 1,150 ₹1.5 L |
| 6.00 | M&L for Vitrified ceramic tiles Light Shade10 mm thick ( Square/ rectangular) polished area of each tiles not exceeding 0.36 Sqm in vertical surfaces such as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including provision of backing coat of 10mm thick in CM (1:6), complete all as specified and directed. | 13.4 | Sqm | 1,200 ₹16,080 | 1,150 ₹15,410 | 1,350 ₹18,090 | 1,150 ₹15,410 |
| 7.00 | M&L for coloured glazed ceramic tiles size 300 x 450 x7 mm thick on vertical surfaces, set & joined in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including backing coat of 10mm thick in CM (1:4) all as specified & directed by Engineer-in-charge. | 85 | Sqm | 1,050 ₹89,250 | 950 ₹80,750 | 1,000 ₹85,000 | 900 ₹76,500 |
| 8.00 | M&L 20mm thick Granite of black / green / imperial red (colour as approved by (engineer-in-charge) of any type work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including screed of 15 mm thick / rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab or with suitable adhesive ncluding pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Note : Single piece should be used in steps/cills/jambs/shelves or equivalent as approved by Engr-in-Charge. | 30 | Sqm | 2,450 ₹73,500 | 2,700 ₹81,000 | 3,150 ₹94,500 | 2,800 ₹84,000 |
| 9.00 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including screed bed or bedding layer of 15 mm thick in CM (1:6) all as specified and directed by Engineer-in-charge. | 450 | Sqm | 1,050 ₹4.7 L | 1,200 ₹5.4 L | 1,340 ₹6.0 L | 850 ₹3.8 L |
| 10.00 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar and laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick backing coat in CM (1:4) complete all as directed by Engineer-in-charge. | 45 | Sqm | 1,200 ₹54,000 | 1,300 ₹58,500 | 1,400 ₹63,000 | 860 ₹38,700 |
Updated dates
Tender Value
₹66.2 L
EMD Value
₹1.2 L
Closing Date
3 Apr 2026, 6:00 pmClosed
CWE (A) JAISALMER
HQ CWE (A) JAISALMER, RAJASTHAN, PIN- 345001
SPECIAL REPAIRS TO BLDG NOs P-16, T-19, P-50 AND T-06 AT POKARAN MIL STN UNDER AGE (I) POKARAN
2026_MES_754613_1
84384/C/E8
Open Tender
Civil Works
346 days
POKARAN
AS PER NIT
8 documents required · 8 mandatory
₹1,000
AGE (I) POKARAN
₹1.2 L
Yes
15 Jun 2026
27 Feb 2026
4 Apr 2026
27 Feb 2026
3 Apr 2026
20 Mar 2026
27 Feb 2026 - 13 Mar 2026
Dismantling of Stone slabs and tiles of any description or thickness in floors, walss, aprons etc., removing serviceable tiles to store and rubbish off the premises.
Dismantling of floors health or walls tiling and Stone floor including cement mortar bedded (but not backing) & removing serviceable tiles to store and rubbies of the premises
M&L for non skid ceramic coloured tiles of 7 to 8mm thick, (square/rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm , as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in CM (1:6) complete all as specified & directed by Engineer-in-charge.
M&L for Non Skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm , over 15 mm thick screed bed in CM 1:4 in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and directed.
M&L for Vitrified ceramic tiles, Light Shade 10mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white or colour cement to match with and including provision of 15 mm thick screed bedding in CM (1:6), complete all as specified and directed.
M&L for Vitrified ceramic tiles Light Shade10 mm thick ( Square/ rectangular) polished area of each tiles not exceeding 0.36 Sqm in vertical surfaces such as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including provision of backing coat of 10mm thick in CM (1:6), complete all as specified and directed.
M&L for coloured glazed ceramic tiles size 300 x 450 x7 mm thick on vertical surfaces, set & joined in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including backing coat of 10mm thick in CM (1:4) all as specified & directed by Engineer-in-charge.
M&L 20mm thick Granite of black / green / imperial red (colour as approved by (engineer-in-charge) of any type work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including screed of 15 mm thick / rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab or with suitable adhesive ncluding pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Note : Single piece should be used in steps/cills/jambs/shelves or equivalent as approved by Engr-in-Charge.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including screed bed or bedding layer of 15 mm thick in CM (1:6) all as specified and directed by Engineer-in-charge.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar and laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick backing coat in CM (1:4) complete all as directed by Engineer-in-charge.
M&L for Complete removal of existing water proofing treatment incl bedding if any n exc. 50mm thick etc. on any type of roof, cleaning with wire brushers etc. and removal of debris out side MD land complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate for levelling course for consolidated thickness 40 mm all as per the requirements all as directed by Engr-in-Charge.
M&L for 10mm thick screed plaster on roof for laying in CM 1:4 waterproofing treatment, with using WPC (WPC will be measured and paid separately as supply only)
Supply only integral liquid water proofing compound complete all as specified and directed.
M&L for water proofing treatment with 3 mm thick APP (Actatic Poly Propylene) modified membrane reinforced with non woven polyester mat of weight 150 gms/sqm as centre core & without multiple layers of polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane after applying a coat of bituminous primer @ 0.3 kg/sqm over roof (an overlap of 100 mm & 150 mm shall be provided on sides & end respectively )including a coat of bitumen grade 85/25 @ 1.20 Kg/Sqm and applying one coat of aluminium paint @ 100ml/sqm on top of APP membrane to get uniform finish complete all as per specified and directed.
Dismantling roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar cement concrete is rainforced(reinforcement cut as required to facilitale demolition) complete all as specified
M&L for jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted, set, jointed and grouted in CM 1:3 as directed by the Engineer-in-Charge.
Taking down cement plaster on stone walls including raking out joints, hacking for key, scrubbing down with water all as specified
M & L for rendering 10mm thick ready mix plaster on internal wall by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS-2250-1981 and shall confirm 28 compressive days cstrength 10-15 MPA bulk dencity 1600-1800 kg/cum and pull out bond strength-> 0.5 MPA omplete all as specified and directed.
M & L for Cement plastering 15mm( thick in two layers -first layer 10mm thick with ready mix plaster and outer layer 5mm thick ready mix water proof plaster) on outer walls by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS- 2250-1981 and shall confirm 28 days compressive strength 10-15 MPA, bulk density 1600-1800 kg/cum and pull out bond strength->0.5 MPA complete all as specified and directed
M & L for rendering 5 mm thick ready mix self curing plaster on ceilling by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS-2250-1981 and shall confirm 28 compressive days cstrength 10-15 MPA bulk dencity 1600-1800 kg/cum and pull out bond strength-> 0.5 MPA omplete all as specified and directed.
M & L for Applying 3mm thick wall care putty on wall for desired smoothness and levelling of surfaces in two or more layers) for receiving painting complete all as specified and directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the AGE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the AGE as well as to the Engineer-in-Charge through site order.
M&L for preparation new surfaces of walls and applying two coat of 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of primer complete, as per manufacturer's specification and all as speified and directed
M&L for preparation of newly plastered surfaces of ceiling/walls and applying two coats of oil bond distemper over one coat of 3mm putty including one coat of primer all as specified & directed by Engineer-in- Charge.
M&L for preparation new surfaces of walls and preparation of surfaces (external faces) of walls and applying two coats of external weather proof paint of Apex or equivalent over a coat of primer (self coat) complete all as per manufacturers instructions, complete all as per specified and directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, including preparation of new surfaces of walls, complete all as specified and directed.
Taking down door chowket or frame incl shutter area n exc 1.50 sqm each and removing to store.
Taking down door chowket or frame including shutter area exc 1.50 sqm and n exc 4.00 sqm
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
S&F rolled MS Roof trusses (framed), sunshade frames, purlins, rafters, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W(Gde-E-250) all as specified and directed by Eng-in-Charge.
S&F MS Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe Fe 290 Gde E-165 all as specified and directed
S&F in repairs 50mm dia MS pipe as in shaft in rolling shutters including taking out old unserviceable pipe complete all as directed by Engineer-in-Charge.
S&F in repairs steel rolling shutters, 1.00mm thickness of laths with out ball bearing,but gear operated type with bevel gear box and crank handle as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete. Note :- Rate including greasing, change of rod, lock, cover hood and other accessories as required as apprived by accepting officer
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, in opening as per specification & drawing all as specified and directed
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, & joined together with solvent cement, in the frame at site as per specification & drawing.
Powder coated 50 microns extruded aluminium glazing/ doors & shutters made out of section 63.5x38.10x1.29mm for chowkats or frame & shutters made of size 44.45x44.45x1.29mm for side rails and middle rail, 114.3X44.45X1.29mm for top rails and bottom rails and including 12mm thick High Density Fibre Board pre-laminated on both sides (water proof) below middle/lock rail and 5mm thick tinted glass above middle/lock rail and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beads 20mm size with and incl mortice lock with duplicate keys etc complete all as specified and directed approved by Enge-in-Charge including supply and fixing the following items: (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 3 nos per leaf. (b) Powder Coated Aluminium Tower Bolt 200mm long - 2 nos per leaf (c) Powder Coated Aluminium Handles 150 mm - 2 nos per leaf
Dismantling of boarding, any description, fixed in any position with nails complete all as specified & directed by Engineer in Charge.
Powder coated 50 microns extruded aluminium frame for fixed type partition (Standard two panel pattern) made out of powder coated aluminium section of size 63.5 x 38.10 x 1.5mm, comprising of 5mm thick tinted glass inserted in and including necesary jointing cleats, rubber packing, anodised aluminium snap beading complete fixed to floor and wall by means of cadium plated steel screws complete incl taking down of existing partition with all fittings and fixtures all as specified and directed.
S & F Factory made ISI marked flush door shutters 30mm thick, BWP conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 2nd class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters complete all as specified and including supply and fixing following items As approved by Accepting Officer : (a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm - 4 Nos per leaf (b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf (d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm - 1 No per leaf (e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 No per leaf
S&F floor door stopper of aluminium 150mm size.
S&F stainless steel wire 0.36mm nominal dia of wire and average width of aparture 1.40mm complete all as specified & directed by Engineer-in-charge.
S&F 4 mm thick figured glass, pin headed type and glazing with oil putty in square n exc 0.50 sqn in Each pane.
M&L for preparing new untreated steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide primer
Supply & fixing in repairs Stainless steel tubing of 25 mm dia chromium plated min. 1.0 mm wall thickness as in curtain rod complete incl S&F 02 Nos stainless steel brackets/finials fency type, stops fixed with ss screws etc all as specified & directed. Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered as approved by Engr-In-Charge.
Demolition of cement concrete unreinforced in groundfloors and pavings not exc 15cm thickness below or above ground level etc all as specified and as directed by Engineer-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C-2 as in plinth protection and surface finished even and smooth w/o using extra cement as specified & directed by Engineer-in-Charge.
Dismantling wall and ceiling boarding of any description, thickness including cover fillets complete al as specified and directed.
M&L for providing and fixing Gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instructions all as specified and directed.
S&F for Anodised aluminium snap grid of size of grid 605 x 605mm frame work for false ceiling all as specified and directed. Note :- (i) Main tee, cross tee shall be 35x25x1.5mm & 25x25x1.5mm respectively. Angle at end all along the walls shall be 40x25x2mm. (ii) Rate quoted by the contractor shall deemed to inclusive of frame work complete all as specified and directed.
Dismantling of water tanks and removing to store capacity of tank exc 250 and n exc 500 ltr.
Supply and fix rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part-I ,500 ltr capacity all as specified and directed
S & F in repair Ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to dia of pipe 20mm as in repairs complete all as specified and directed.
Supplying and laying in repair of CPVC pipes 16mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including taking down or up existing GI tubing & connections all as specified and directed by Engr-in-Charge.
Supplying and laying in repair of CPVC pipes 20mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including taking down or up existing GI tubing & connections all as specified and directed by Engr-in-Charge.
S&F fixed in repairs gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed in repairs to 15 mm bore pipe all as specified and directed
S&F fixed in repairs gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed in repairs to 20 mm bore pipe all as specified and directed
S&F in repairs for stop cock 15mm bore copper alloy but fancy type and chrominum plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron/pipe or for union and fixed all as specified and directed
S&F in repairs bib taps 15mm bore cast cipper alloy chromoum plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and directed
Supply and fixing in repair of fancy type pillar taps 15 mm bore cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shank supply and fixing ly nuts for iron pipe all as specified and directed
S&F in repairs Viterious china White Wash Hand Basin of size 580mm x 450mm including 15 mm pillar cock cast copper alloy CP, 15mm cast copper stop valve, 32 mm brase CP waste fitting, PVC waste pipe 32 mm dia & 15 mm PTMT connection pipe 450 mm long, all as specified and directed
S& F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws
S&F in repairs towel rail 600 mm long of Brass C.P 'D' type fixed with and including chromium plated brass screws and wooden /plastic cheats all as specified and directed
Supply & fixed in repairs stainless steel sink with drainage board , made out of 1.00mm thick sheet for kitchen or laboratory with plug,washers, waste pipe, cast irn cantilever bracket of overall size 915x460mm bowl size 410x330x160mm complete all as specified.
S&F in repair CP Shower rose 125mm size with swivel joint including fixing sted pipe for union.
S & F in repair Vitreous china wash down water closet w EWC P trap white/ivory/off white including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe PVC 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, incl 100mm dia cast iron sanitary connections—short connections pipe of length upto 600 mm and Cutting holes in or through walls, packing with PCC 1 : 2 :4 complete and taking down existing of any description/size complete in all respect all as specified.
S & F in repair Flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified.
S&F in repairs PVC connections 15 mm size with PTMT nuts to length 600 mm.
S & F in repair Toilet paper holder with flat recessed type stainless steel Coomplete all as specified and directed.
M&L for Cutting holes in to or through in brick or stone walls built in cement mortar and making good in CM 1:3 or cement concrete 1:2:4 type B1 as required, exc 150sqcm & n exc 400 sqcm complete all as specified and directed,
Dismantling of cast iron Rcc, Ac or PVC pipe jointed in CM any dia bore
S&F in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia out let
S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls
S&F PVC (SWR) pipes of 75 mm dia, single socket fixed to walls
S&F in repairs 100 bore of pipe stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof.
S&F in repairs PVC (SWR) bends with access door of 110 mm dia, any radius
S&F in repairs PVC(SWR) bends with access door of 75 mm dia, any radius
S&F in repairs PVC (SWR) bends of 110 mm dia, any radius
S&F in repairs PVC (SWR) bends of 75mm dia, any radius
S&F in repairs (PVC (SWR) vent cowl, 100 mm dia
Demolition of brick masonry or stone masonary built in cement mortar of any type.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling, Jodhpur type brought up to courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed, but except stone.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses all as specified & directed by Engineer-in-Charge.
Dismantling of Trellis work (Jafri), including taking as under of battens in trellis (posts and rails measured separately) One way type
Material & Labour for 35mm thick precast cement concrete louvres and jallies type C-0 (1:3:6) using 12.5mm graded stone aggregate (measured solid), in cluding all mouldings and frame set in cement mortar 1:4 all as specified and directed
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering
S & F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified.
Dismantling of Bricks (laid flat or on edge)laid dry and pointed or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) complete all as specified and directed.
M&L For cement concrete type B1 1:2:4 (20 mm graded aggregate) Providing, in kerbs of mud stops, rounded or chamfered on edges
M/L PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub bases, 100 mm thick complete all as specified and directed
Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand all as specified and directed
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar as in concrete bed, haunching set in cement mortar of 150 mm Dia complete all as specified.
Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide in manholes,etc. and getting out any type of Soil complete all as specified.
M&L for plain cement concrete 1:4:8 Type D2 using 40mm graded aggregateas in foundation, filling in mass concrete for manholes & drains.
M&L for plain Cement concrete 1:2:4 Type B1 using 20 mm graded aggregate as in benching and surface channel of Manholes.
M&L for plain cement concrete 1:3:6 Type C1 using 20mm graded aggregate as in coping including form work etc complete.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl, forms mould, mi-tred/stopped ends etc.
M&L for rendering 15mm thick in CM 1:4 on stone masonary sufaces including finished even and smooth using extra cement.
M&L for reinforced concrete NP2 drain pipes 150 mm Dia pipes confirming to IS laid in trenches and jointed in CM 1:2 all as specified & directed by Engr-in-charge
M&L for Concrete bed to drain pipes including packing under haunching against the sides of pipe after they are laid and tested; in cement concrete 1:4:8 type D-2 for 150mm dia pipe all as specified and directed.
M&L for reinforced concrete NP2 drain pipes 200 mm Dia pipes confirming to IS laid in trenches and jointed in CM 1:2 all as specified & directed by Engr-in-charge
M&L for Concrete bed to drain pipes including packing under haunching against the sides of pipe after they are laid and tested; in cement concrete 1:4:8 type D-2 for 200mm dia pipe
M & L for cutting in to existing manhole for connectiing new drain 150 mm bore , making good to pipe & rendering cutting out existing benching for & forming branch channel in cement concrete ( 1:2:4) type B1 smooth finished & reforming benching as requierd.
Returning filling in soil including spreading, levelling and well ramming in layers n.exc 25cm thick in layer etc all complete.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
E&M Items Taking down carefully existing point wiring of any description light, fan,sockets,bells etc) complete including fittings such as terminal boxes, switches, sockets, ceiling rose, lamp holders, brackets sketch fittings, pendants, fan regulartors and making good the disturbed surfaces, walls, floors etc. all as directed by EIC
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse)
Taking down old unsv MCB DB / main switch incl MCBs / MCCBs complete all as specified and directed
Taking down existing sub main wiring /Service wire of any description and size including earth wire, quities and making good disturbed surfaces of walls, floors etc. Including one run of 2mm dia bare earth continuity wire all as specified including taking down of sub main wiring. (Note : Two runs of aluminium conductor, and one run of GI earth wire will be measured and paid as one unit only)
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. for stone concrete block or slab walls and making good, cutting exceeding 20cm girth
M&L point wiring complete with 1.5 Sqmm single core PVC insulated FRLS cable 1100 Volts grade multistranded copper conductor drawn through in PVC Conduit concealed on underground stone / brick, masonry walls, roofs floors etc including MS terminal boxes fabricaterd out of 1.12mm thick MS sheet sunk type / surface type and laminated top sheet of 2mm thick for housing switches sockets, regulators etc including provn of 1.5 sqmm dia copper conductor for earth wire connected to common dolly for One light point / Fan point / Exhuast Fan / Bell point controlled by one 5 Amps One way switch and making good surfaces all as specified and directed by Engineer-in-Charge.
All as per Item No. 06 but for one 3 pin 5/6 Amps switch socket outlet on same board
All as per Item No. 06 but for one 3 pin 5/6 Amps switch socket outlet on independent board
All as per item No. 06 above but wiring with 4.0 Sq mm and 4.0 sqmm for earth continuity for 3 pin 15/16 Amps switch socket combination
M&L switch Modular switch 1 way 6A, 1 module single pole complete all as specified and directed.
M&L Modular switch 1 way 16A, 1 module single pole confirming to IS 3854 : 1997 complete all as specified and directed.
Moidular Bell Push Modular Bell push 6A 1 module
Buzzer, Ding Dong AC. 230 volts, single pole
M&L Modular Socket 6A 2/3 pin combined 2 module outlet, multipurpose complete all as specified and directed.
M&L Modular Socket 16/6A 3 pin combined 2 module outlet, multipurpose complete all as specified and directed.
S&F Electronic type Modular fan step regulator 120W, 2 module AC 240 V all as specified and directed
M&L Modular white cover plate with frame ( both inner & outer plate cover) 1 module
M&L Modular white cover plate with frame ( both inner & outer plate cover) 3 module
M&L Modular white cover plate with frame ( both inner & outer plate cover) 4 module
M&L Modular white cover plate with frame ( both inner & outer plate cover) 6 module
M&L Modular white cover plate with frame ( both inner & outer plate cover) 8 module
M&L lamp holder insulated body with back plate suitable for battern fittings
supply and fix LED Lamp Retro fit type 9 watts 230 V and all as specified by Engr-in-charge
S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminais all as specified
S&F Sheet Modular metal enclosure DB SPN 240 Volts 8 Way single door type with 200 Amps busbar for fixing of MCBs
S&F Sheet Modular metal enclosure DB SPN 240 Volts 4 Way single door type with 200 Amps busbar for fixing of MCBs
S&F Sheet Modular metal enclosure DB SPN 240 Volts 12 Way single door type with 200 Amps busbar for fixing of MCBs
S&F in repair MCB Single pole and neutral, 'C' Curve, 40A, 240 Volts AC all as specified
S&F in reapir MCB Single pole,'C curve' 6-32A, 240 Volts AC all as specified
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC concealed conduit underground stone / brick, masonry walls, roofs floors and conduit accessories of medium grade not less than 25mm dia including one run of single core 4 sqmm PVC insulated FRLS sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring including making good surfaces complete all as specified and as directed. (Note : Two runs of copper conductor and one run of copper earth wire will be measured and paid as one unit only)
M&L Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.5 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead all as specified
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S & F 15 Watt LED Bldg security light with a nominal system . The luminaire housing should be made of pressure die cast aluminimum. The total power consumption should not exceed 15W (including driver) pre wired fitted on and including two Nos PVC block of suitable l size and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmm size and testing complete including LED lamp, including taking down old unserviceable fitting any type complete all as specified and as directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_845198.xls
BOQ • 0.49 MB
TENDER.pdf
Tender Documents • 2.61 MB
Download all tender documents and submit your bid