Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40 L+₹1.7 L (4.41%)Rejected-Finance 6146 HIRA CHOWK SIRKI BAZAR BATHINDA PB 151005 | BATHINDA | PUNJAB | 151005 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹42.0 L+₹3.7 L (9.55%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹44.8 L+₹6.5 L (17.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
22 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura Cantt
SPL REPAIR TO BLDG NO P-194 OTM ACCN UNDER GE HISAR
2020_MES_396014_1
CWE/MTR/HSR/58 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
Hisar
Class D cat a (i)
7 documents required · 7 mandatory
₹500
GE Hisar
₹99,000
Yes
12 Feb 2021
21 Nov 2020
24 Dec 2020
21 Nov 2020
22 Dec 2020
10 Dec 2020
60 days
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thickness below or above ground level complete all as specified and directed.
M&L 20-25mm thick Kota stone slabs of size 550 x 550mm (minimum) over and including 20mm thick screed layer in CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of stone incl rubbing & polishing complete all as specified and directed.
M&L 20-25mm thick Kota stone slabs as in vertical surfaces like dado or skirting over 10mm thick rendering in CM (1:3) set & joined in neat cement slurry and pointed in coloured cement to match incl rubbing & polishing complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and removal complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed bed CM (1:4) complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 300 x 450 x 7mm thick as in vertical surface like dado or skirting set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar (1:3) complete all as specified and directed.
M&L vitrified ceramic tiles light shade 10mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed bed in CM (1:4) complete all as specified and directed.
M&L vitrified ceramic tiles light shade 10mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 sqm as in vertical surface like skirting or dado set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick cement screed bed in CM (1:3) complete all as specified and directed.
M&L PCC 25mm thick 1:2:4 type B-0 using 12.5mm graded stone aggregate in sub flooring complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 (Using 40mm graded stone aggregate) as in plinth protection including finishing even & smooth without using extra cement complete all as specified and directed.
M&L 60mm thick machine pressed precast cement concrete interlocking paver block coloured with glossy finish with using gray cement and pigments of grade M-35 of any shape and size confirming to IS-15658-2006 such as I-Shape, unioctagonal, three X, dumble, zigzag etc laid over and including 25mm thick sand cushion complete all as specified and directed.
Treatment of sunken floor slab compraises of the following specifications and all as specified :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout. (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (vi) GI pipe 50mm dia medium grade 50cm long laid on each sunken floor as spout complete all as specified and direced by EIC. (vii) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (viii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint. Note :- (i) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is included in the rates quoted above. (ii) All debries obtained from site will be thrown away out side MD land by contractor at his own expense. (iii) Integral water proofing compound shall be measured and paid separately under relevent item of BOQ (Schedule 'A').
Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work and mixing integral water proofing compound @ 3% by wt of cement or as per manufacturer's instructions and finishing the surface even and smooth without using extra cement complete all as specified and directed. Note : Integral WPC shall be measured and paid separately under relevant items of BOQ (Schedule 'A')
M&L for 12mm thick rendering in cement mortar (1:4) on fair faces of brick work and mixing integral water proofing compound @ 3% by wt of cement or as per manufacturer's instructions and finishing the surface even and smooth without using extra cement complete all as specified and directed. Note : Integral WPC shall be measured and paid separately under relevant items of BOQ (Schedule 'A')
M&L rendering 10mm thick on concrete surfaces on ceiling, sunshade and chajjas in CM (1:3) finished even and smooth without using extra cement complete all as specified and directed.
M&L Rough cast plaster (Rendering coat not less than 10mm thick in C:M 1:3 while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg size 6 to 12mm mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even) complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for complete removal of existing treatment of old surface of wall and applying two coats of oil bound distemper ove a coat of wall care putty (not less than 1mm thick) over a coat of alkali resistant primer on wall complete all as specified and directed.
M&L two coats of Oil bound distemper on new plastered or unplastered surfaces over and including not less than 1mm thick acrylic wall care putty and a coat of alkali resistant primer on walls including preparation of surfaces complete all as specified and directed. Note : The work under srl item No 19 & 20 shall be got carried out by contractor from authorised applicator of manufactrurer by using modern technique.
M&L Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation old decocated surfaces of walls by brooming down or by steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of cement base paint on old decorated plastered surfaces of walls complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete conforming to FE-290 Gde E-165 complete all as specified and directed.
Demolition of cement concrete (reinforced) in any position in roofs, floors (other than ground floor), beams, staircases, landing, chhajjas and similar suspended work complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (20mm graded aggregate) as in Beams, cantilevers, bressummers lintel over 1.5m span & similar RCC works complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar internal dia of pipe 150mm complete all as specified and directed.
M&L for 150mm bore Reinforced concrete pipes class NP2 laid and jointed with collars in trenches complete all as specified and directed.
M&L for concrete bed to drain pipes in PCC (1:3:6) types C-2 including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore of pipes complete all as specified and directed.
M&L for cement concrete (1:3:6) types C-2 (40mm graded stone aggregates) as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds complete all as specified and directed.
M&L precast cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in manholes and septic tank cover slab etc and set in cement mortar (1:4) complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches pillars etc complete all as specified and directed.
M&L for Brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L brick work with FLY ASH bricks straight or curved on plan to any radius in half brick thick wall built in old size brick in CM 1:4 complete all as specified and directed.
Dismantling of old roof treatment of any type any thickness any pattern including dismantling of old brick tiles and mud phuska and clean the surface up to RCC roof. M&L for preparation of RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles. Filling the cracks by crack filler. Providing PCC 1:3:6 at the places where slope is not proper or roof surface is uneven to maintain the proper roof slope. Providing 25mm thick polymer modified plaster in ratio 1:10 (1 part of polymer and 10 parts of cement with solid contents not less than 30%) over slab and applying priming coat of epoxy primer with resin and hardner with water dilution as per manufacturer instructions, applying 1st coat of solvent based polyurathene liquid membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 Kg/Sqm and applying 2nd coat solvent based polyurathene liquid membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 Kg/Sqm over dried 1st coat complete all as specified and directed. Make : Pidilite / STP / Sika / Asian Paints
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc. 1.50 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.50 sqm & n.exc 4.00 sqm each complete all as specified and directed.
S&F in repair 3mm thick polycarbonate sheet (transparent sheet) in square n.exc 0.5 Sqm in each pane fixed with oil putty and silicon gel with screw complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F 30mm thick flush shutter, soild core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed.
S&F 35mm thick factory made glazed and skeleton shutters of 2nd class HW open rebated and prepared to receive glass/gauze etc edges or framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc as specified in SSR pt-1 section 8, clause 8.24 (a) complete all as specified and directed.
S&F butt hinges 100mm stainless steel including necessary welding if required complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
S&F 200mm long Aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F for 150mm long Extruded aluminium alloy handles, cast type, anodised complete all as specified and directed.
S&F 300mm, Mild Steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
Taking down old unserviceable steel windows complete all as specified and directed.
S&F factory made steel window / ventilator, ISI Marked, with side hung shutter including projecting type hinges with steel handle and steel peg stay with glazing bar, dovetailed or welded complete all as specified and directed.
S&F factory made steel window / ventilator, ISI Marked, with side hung shutter including projecting type hinges with steel handle and steel peg stay without glazing bar, dovetailed or welded complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description not otherwise described exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed.
M&L for preparation of old wooden surface of any description not otherwise described, exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
M&L for preparation of new steel surface of any description not otherwise described exc 10cm width or girth and applying two coats of synthetic enamels paints over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old steel surface of any description not otherwise described exc 10cm width or girth and applying a coat of synthetic enamel paint complete all as specified and directed.
Taking up or down steel water tubing and connection of 15mm bore complete all as specified and directed.
Taking up or down steel water tubing and connection of 20mm bore complete all as specified and directed.
S&F for GI tubing 15mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed.
S&F for GI tubing 20mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed.
Dismantling water tanks of any type & capacity complete all as specified & directed.
M&L PVC water tank triple layer white in colour rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted & fixed in position of capacity 2000 ltr complete all as specified and directed.
S&F in repair 15mm bore chromium plated cast copper alloy bib taps with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair chromium plated angular valve / stop valves, cast copper alloy screwed down high pressure, screwed both ends for 15mm bore iron pipe or brass ferrule complete all as specified and directed.
S&F Ball brass valves 20mm bore high pressure with polythene float and fly nut screwed for iron pipe complete all as specified and directed.
S&F PVC connection 15mm size, of length 450mm, with PTMT nuts complete all as specified and directed.
S&F 125mm dia gratings with waste hole of PTMT (Min wt 40 Gm) complete all as specified and directed.
S&F in repair brass chromium plated shower rose fancy type 75mm dia with swivel joints complete including 150mm long brass chromium plated arms fixed to steel pipe or union complete all as specified and directed.
S&F in repair vitreous china squatting pan (1st quality) ISI marked Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick alround and finished just below level of rim of pan to receive the floor finishing complete all as specified and directed.
S&F in repair viterous China wash down water closet (pedestal pattern) complete connecting to flush pipe, including plastic seat cover block with flat bottom and mild steel chromium plated or aluminium hinging device (excluding flushing cistern and flushing pipe) complete all as specified and directed.
S&F in repair, PVC low level cistern 10 lit capacity, valveless, syphonic action type with float, handle incl 32mm dia flush pipe of polyethylene of low or high density or PVC & bracket etc complete all as specified and directed.
S&F in repair Viterous China urinals, Half stall type, white, with grating and union for discharge pipe including connection to flush pipe and outgoing pipe complete including providing and fixing plug, beding urinal agianst wall in cement mortar 1:2 securing urinal to plug with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
S&F in repair stack clamps made out of 50mm by 5mm flat iron and 16mm round iron stay including bolts and nuts and securing ends of stays to wall or roof complete all as specified & directed.
S&F for cast iron 100mm bore sand cast soil waste and vent pipe in any length with or w/o ears with cement joints laid in trenches or in floors or fixed to wall complete all as specified and directed.
S&F for cast iron 75mm bore sand cast soil waste and vent pipe in any length with or w/o ears with cement joints laid in trenches or in floors or fixed to wall complete all as specified and directed.
S&F 100mm CI Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.
S&F 75mm CI Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.
S&F 75mm CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F 100mm CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F in repair PVC (SWR) floor trap plain with stainless steel grating with dia of outlet 75mm including jointing with solvent cement complete all as specified and directed.
S&F 100mm CI Bends (any radius) with duck’s foot or heel rest complete all as specified and as directed.
S&F cast iron cowl 75mm dia as required complete all as specified & directed.
S&F cast iron cowl 100mm dia as required complete all as specified & directed.
S&F in repair tubular towel rail, brass chromium plated 20mm dia D type, 60cm long between flanges complete all as specified and directed.
S&F in repair 22mm to 23mm dia mild steel PVC coating decorative type (drapery) curtain rod with decorative type side cups and PVC feneals brackets complete all as specified and directed.
S&F in repair MS window handle for steel window for left and right shutter with nut and bolt complete all as specified and directed.
S&F in repair casement stays, size 300mm, with hinged joint and two plates with studs complete all as specified and directed.
S&F plain GI MS wire galvanized class 3 mosquito net dia or wire of 3.15mm fixing with pertaining bolt, hooks eyes etc complete all as specified and directed.
S&F brass screw (screw and nail combination) for fixing of mosquito wire in the brick wall after drilling hole in the wall min weight 250 gm complete all as specified and directed.
Taking down rain water pipes (any size or pattern) including all fittings complete all as specified & directed.
S&F 110mm dia PVC rain water pipe single socketed with rubber joint, jointed with solvent cement fixed to wall complete all as specified & directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F MS framed work such as grills, cooler stand, grating, etc., with ends of bars, sections shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work or water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Taking down shutters of any description area n.exc 1 sqm each leaf complete all as specified and directed.
S&F factory made Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes, fixed in opening as per specification & drawing given in SSR Part-II 2010.
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile), with particle board core and 2, 4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
Chipping of loose / damaged / cracked / previously repaired / delapidated or weak concrete shall be chipped of to expose the sound core concrete whereever required to expose rusted reinforcement for all depth complete all as specified and directed.
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using Product : Rustoff-100 of Sika or equivalent make in Fosroc / Thermax as approved by GE, with density : 1.01 Kg / ltr at 30°C and consumption : 0.2 kg / Sqm / coat complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg / Sqm for two coats and product requirements: carbonation resistance : 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N/Sqmm according to ASTM C 882-78 complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
M&L for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer’s specification including prepartaion of surface by chipping and throughly cleaning complete where ever required with using Product : Sikadur®-32 LP of Sika or equivalent in Fosroc / Thermax as approved by GE with consumption : 0.4 kg/Sqm and Product requirements : Complies with ASTM C 881-78, Type II Grade 2 Class B+C complete all as specified and directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness of upto 10mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for drilling of holes 8 to16mm dia 50 to 75 mm deep using electrical drill and cleaning of holes by vacuum or compressed air on the face of columns as per the technical specifications and manufacturer's instructions complete all as specified and directed .
M&L for Providing, fixing shear connector of 16 mm dia TOR steel upto 160 mm length with Sika anchorfix @ -3+ Tropical or equivalent make in Fosroc / Thermax as approved by GE, epoxy resin to RCC member including power drilling, cleaning of holes, insertion of epoxy, placing shear connector in position to ensure the bond as per manufacturer’s instructions complete all as specified and directed.
M&L 8 to 12mm dia mild steel TMT reinforcement bars 'L' shaped shear connector and shall be fixed with RCC member using two component polyster rasin anchoring grant (LOKF1X525) of Fosroc or equivalent in Dr Fixit / Sika as approved by GE as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for providing and fixing water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete as per site requirement and directions of Engineer-in-charge.
Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (<100 mm) using Product : SikaRep® Microcrete-4 + adequate coarse aggregate, Yield: approx. 17 ltr/bag (30kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep® Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99 complete all as specified and directed.
M&L for providing and application of one coat of Water based concrete curing compound with low viscosity wax emulsion using Sika Antisol E-WP of Sika or equivalent make in Fosroc / Thermax as approved by GE, as concrete curing membrane over the applied polymer mortar as temporary curing membrane as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for cutting V groove (15mmx10mm) along the crack line and cleaning the same with high pressure water jet and sealing with fast setting high strength Epoxy putty, solvent free, three component compound based on epoxy resins, graded fillers and thixotropic agents using Sikadur 31 of Sika or equivalent make in Fosroc / Thermax as approved by GE as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for providing and fixing 12-16mm dia injection ports non returnable nozzle by drilling cleaning and sealing holes 50-75 mm deep at 200mm c/c with fast setting high strength Epoxy putty, solvent free, three component compound based on epoxy resins, graded fillers and thixotropic agents using Sikadur 31 of Sika or equivalent make in Fosroc / Thermax as approved by GE as in beams, columns and parapets as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for grouting of nozzles with low viscous moisture insensitive, High strength, epoxy resin grout with Sikadur 52 LP (IN) of Sika or equivalent make in Fosroc / Thermax as approved by GE with pressure not exceeding 2-3 kgf/Sqcm till the nozzle refuses to take further grout including cutting extra length of the nozzle after the grout hardens and finishes as per the technical specifications and manufacturer's instructions complete all as specified and directed. Note for Srl item No 100 to 114 : (i) Necessary scaffolding / props (minimum one prop per sqm) required for repair works against aforesaid items is deemed to be included in contractor's quoted rate. (ii) Work has to be carried upto two storey buildings and nothing extra shall be paid to contractor on this ground. (iii) Digital photo / videography for all items of structural strengthening shall be done by the contractor in presence of JE (Civ) / Engineer-in-Charge. Copy of CD thereof shall be deposited to Engineer-in-Charge for record on completion of each stage as elaborated here-in-above. (iv) Cement used for the structural repair / rehabilitation work shall be of OPC grade.
Taking down carefully surface aluminium point wiring with wooden battens / PVC conduit (light, fan, socket, bell or power) including fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators etc and making good disturbed surfaces complete all as specified and directed.
Taking down old unserviceable / burnt copper / aluminium submain wiring of any size including earth wire and making good of the disturbed surface and removing the material from site complete all as specified and directed.
M&L for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 1.5 sqmm drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories including sunk type pressed steel terminal boxes with 3mm thick bakelite sheet top cover for mounting switches, sockets, fan regulators, including cutting, chasing on wall and other surfaces and making goood disturbed surface complete for the following :-
One light / fan / bell / exhaust fan controlled by one switch.
One socket outlet 5 pin, 5 amp controlled by one switch on indepdendent board.
One socket outlet 5 pin, 5 amp controlled by one switch on the same board.
M&L for point wiring with 1100 volts grade PVC insulated unsheathed FRLS single core multistranded copper conductor cable 2.5 sqmm drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories including sunk type pressed steel terminal boxes with 3mm thick bakelite sheet top cover with earth continuty conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 2.5 Sqmm complete for one switch socket combination 3 pin 15 Amp one no controlled by one switch on independent board, including cutting, chasing on wall and other surfaces and making the good disturbed surface complete.
S&F socket outlet 3/6 pin and 15 Amps flush type complete all as specified and directed.
S&F socket outlet 5 pin and 5/6 Amps flush type complete all as specified and directed.
S&F switch piano flush button single pole one way 5 Amp complete all as specified and directed.
S&F switch piano flush button single pole one way 15 Amp complete all as specified and directed.
S&F bell push, 5 Amp Single pole 230 volt polycorbonate body complete all as specified and directed.
S&F electric bell ,Ding Dong, type AC 230/250 volts grade single pole ISI marked complete all as specified and directed
S&F lamp holder B-22 base insulated body with back plate and connecting up complete all as specified and directed
S&F LED bulb of capacity 15W complete all as specified & directed. Make : Havells Cat part No LHLDDEEEML8R015 or equivalent in make as specified in Appx 'B'.
S&F ceiling rose of 65 x 50mm PVC / polycarbonate three terminal surface bakelite complete all as specified and directed.
S&F LED base fixture including 18/20 retro LED tube rod energy saving surface mounted luminaire, high efficiency PMMA diffuser gives soft glare free light environmental friendly, energy efficient ready to use pack complete all as specified and directed. Make : Cat Part No SUB 118 T8 LED of Surya or equivalent and tube rod of 18/20W of Cat Part No SLE TL-DS 18P of Surya or equivalent make as specified in Appx 'B'.
S&F electronic ceiling fan regulator stepped type heavy duty suitable to work on 230 volts complete all as specified and directed.
Disconnecting & taking down ceiling fan carefully during re-wiring work & after complete re-wiring connecting, hanging ceiling fan with connecting wire including servicing (oil and greasing), and one coat of synthetic enamel paint by spray machine including filling cavities with fillar complete including extension of down rod upto 1.30m below ceiling complete all as specified and directed.
S&F sheet metal enclosure DB TPN 4 way with 200 amps rated bus bar three phase 415 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 42 suitable for mounting MCCB FP as incoming and MCB (TP / SP) as outgoing MCB DB confirming to IS-13032, IS-8623, BS-5484 having door earthing complete all as specified and directed.
S&F MCCB 100 Amp 4 Pole Breaking capacity 16 KA, (type 'C' curve) complete all as specified & directed.
S&F MCB single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10 KA (type 'C') complete all as specified & directed.
S&F MCB SPN, 240 Volts, 40 Amps breaking capacity 10 KA (type 'C' curve) complete all as specified & directed.
S&F sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 suitable for mounting MCB DB confirming to IS-13032, IS-8623, BS-5484 having door earthing complete all as specified & directed. Note for item No 131 to 135 : MCBs & MCB DBs shall be of the same make. MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces.
S&F of sheet metal enclosures with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp, 240V complete all as specified and directed.
M&L for Sub main wiring with 2 single core PVC insulated unsheathed cable, 1100v grade with FRLS PVC 6 Sqmm copper cable multi stranded conductor drawn through in and including PVC rigid non metallic concealed conduit 25mm dia, medium duty, ISI Marked to be terminated in DB box as per IS including of 6 Sqmm dia FRLS PVC insulated unsheathed Copper cable as earth wire connected to earth including taking down old unserviceable sub main wiring complete all as specified & directed. Note : Two run of 6 Sqmm cable and one run of 6 Sqmm earth cable and one run of 25mm PVC conduit shall be considered as a unit for measurements purpose.
Supply, laying, jointing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire, armoured heavy duty electric power cable (heavy duty) with aluminium conductor, 1100 volt grade, cross sectional area of size 35 sqmm 4 core laid in trenches wall / floor etc complete all as specified and as directed. Note : Cable may be laid in trenches, under road, across the nallah, along poles/walls and ducts etc. Excavation, earthwork, sand chshioning, cable cover, pipe for cable protection to be measured and paid saprately.
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying cable not exc 10 sqm on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
M&L for returning filling in approved excavated soil including spreading levelling and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50m & depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L sand filling in trenches with clean dry fine sand unwashed including gently punning around cables 8cm thick before laying & 15cm after laying complete all as specified and directed. Note : Punned thickness of sand shall be measured and paid for.
M&L for brick covering to underground electric cable using sub class "B" old size brick laid dry flat per pendicular to the direction of cable complete all as specified and directed.
M&L for replacement of 50 mm bore GI pipe light grade laid in trenches or fixed to wall / pole for protection of cable / earthing strip etc complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15mm dia pipe and GI Pipe 20mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) including taking out old existing earthing complete all as specified & directed.
S&F ceiling fans 1200mm sweep white in colour energy efficient 5 star rating of Aluminium blades (three numbers) and body, double ball bearing, down rod, fan motor, pair of canopy shackle, assembly kit, etc suitable for SP 230 to 250 volts, 50 Hz, AC supply complete all as specified and directed. Make : Havells Model ES-50 (enery saving fan) or equivalent make as specified in Appendix 'B'
S&F heavy duty exhaust fan 450 mm of 900 rpm with all connected assessories including louvers complete all as specified and as directed. Make : Havells Model Turbo Force SP or equivelent make as specified in Appendix 'B'
B B BUILDERS
M/s INDER CONSTRUCTION COMPANY
malik constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .