Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹39.8 L+₹2.3 L (6.03%)Rejected-Finance AMBAGAN TEZPUR TOWN PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹40.7 L+₹3.2 L (8.51%)Rejected-Finance | L3 | Rejected-Finance HIGH BID VALUE | |
| 4 | L4₹41.6 L+₹4.1 L (11.0%)Rejected-Finance | L4 | Rejected-Finance HIGH BID VALUE | |
| 5 | L5₹41.9 L+₹4.4 L (11.8%)Rejected-Finance | L5 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹36.9 L
EMD Value
₹73,800
Closing Date
25 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE TENGA
CWE TENGA
SPECIAL REPAIR/REPLACEMENT OF HT SWITCH GEAR COMPONENETS, BATTERY BANKS, CONTROL RELAY PANES AND ALLIED WORKS AT 33/11KV SUB STATION PHASE-II CHINDIT TOP AREA UNDER GE 859 EWS
2022_MES_555475_1
8321/E8
Open Tender
Civil Works
Item Rate
180 days
GE 859 EWS
D and above b ii
8 documents required · 8 mandatory
₹500
GE 859 EWS
₹73,800
Yes
14 Dec 2022
1 Oct 2022
2 Nov 2022
1 Oct 2022
25 Oct 2022
18 Oct 2022
Amount
Disconnecting and replacing of HT CT 55/25 33 KV, 110 volt , HT PT 33KV,110 volt , lightening arrester for 33, Isolators for 33 KV and lightening conductor for 33 KV incoming system complete all as directed by Engr-in -charge. Note :- Work will be done by engaging experienced technician. Note : Parts to be replaced will be measured and paid separately as "Supply only" against appropriate item(s) of this schedule. However labour cost towards replacement shall be deemed to be included in this item.
Disconnecting and Servicing/ repair to 33 KV HT Panel including necessary wiring for smooth functioning of 33 KV incoming system all as directed by Engr-in -charge.Note :- Work will be done by engaging experienced technician. Note : Parts to be replaced will be measured and paid separately as "Supply only" against appropriate item(s) of this schedule. However labour cost towards replacement shall be deemed to be included in this item.
Repair to existing battery charger 30V, 33KV complete with necessary accessories for smooth functioning complete all as specified and directed by Engr in Charge. Note :- Work will be done by engaging experienced technician.
Repair to existing battery charger 110V, 11KV complete with necessary accessories for smooth functioning complete all as specified and directed by Engr in Charge. Note :- Work will be done by engaging experienced technician.
Supply only followings items(Item Srl No. 5.01 to 5.05) against item Srl No. 1 mentioned here in before.
HT CT 50/25 33 KV, 110 volt Make : Crompton Greaves/Schneider/Areva T&D/Kappa/Elpro
HT PT 50/25 33 KV, 110 volt Make : Crompton Greaves/Schneider/Areva T&D/Kappa/Elpro
Lightening arrester polymer Make : Kappa/Pragati/Elpro/Jaipuriya
Isolator 33 KV 630A Polymer Horizontal type Make : Kappa/Pragati/Elpro/Jaipuriya
Lightening conductor with copper tube and prongs
Supply only followings items(Item Srl No. 6.01 to 6.11) against item Srl No. 2 mentioned here in before.
Relay ADR 141 for 33 KV Panel Make : Ashida/L&T/Scheinder
Auxiliary relay& element 30V DC Make : Ashida/L&T/Scheinder
Master trip relay 30V DC Make : Ashida/L&T/Scheinder
Buzzer Make : Philips/Bajaj/CG
Digital Amp meter 96x96 mm Make : AE/L&T/Ashida
Digital volt meter 96X96 mm Make : AE/Ashida/L&T
TNC switch Make : AE/L&T
12window Ansider 33 KV panel Make : Ashida/L&T
Kilowatt meter Make:Ashida/L&T
S&F Battery 2V for Battery bank 30V,100 AH, dry cell type (2V 15 Nos) of Make : Amara Raja/Exide.
S&F Battery 2V for Battery bank 110V, 100 AH, Dry cell type (2 Volt 55 Nos) of Make : Amara Raja/Exide.
M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point/transformer/panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 32 mm dia light grade GI pipe and 20 mm dia medium grade GI Pipe for watering complete all as specified and directed.
Dismantling of cross arms of MS channel or angle section etc. complete all as specified and directed
Dismantling insulator any type, any size complete all as specified and directed
Dismantling stay assembly complete (incl demolition of concrete) complete all as specified and directed.(Note:Excavation,Returning and Removal will be paid separately under appropriate Item of Sch 'A')
Dismantling ACSR conductors complete all as specified and directed.
S&F cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complete all as specified and directed.
S&F Lightening arrestor, explusion type complete with fitting, transmission class, HT 11000 volt class discharge capacityt 65 KA complete all as specified and directed.
S&F Switches air break, gang operated, tripole, mechanically operated, mounted on insulator and steel frame with operating mechanism work from ground level for current rating up to 200 Amps complete all as specified and directed.
S&F Explusion fuse, single pole complete all as specified and directed.
M&L for stay assembly 20mm with accessories as shown in electrical plate No 1 (loop type insulator, stay clamp, excavation and concrete will be measured and paid separately under appropriate Item of Sch 'A') complete all as specified and directed.
M&L for Loop type insulator,vitreous porcelain white, brown or green, large size with overall dimension 90mm x 140 mm clearance of hole 25.5 mm complete all as specified and directed.
M&L for galvanised stay strand 7/3.15 mm complete all as specified and directed
Supply , laying , in trenches, or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, 11000 volts grade cross sectional area 95 sqmm 3 core, 11 KV earthed, complete all as specified and directed.
Material and labour for cable jointing kit (Earthed) grade cable for outdoor termination heat shrinkage type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including taking down of old unsv cable complete all as specified and directed.
Supply and spreading clean dry sand (unwashed) in trenches around the cable for cushioning complete all as specified and directed.
Supply and laying unreinforced precast concrete cable cover, class HV, type 1 flat size 300 mmx180mmx40mm complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out in hard / dense soil for laying of cable / errection of poles / stay assembly etc complete all as specified and directed.
All as per item No. 25 here in before but depth exceeding 1.5 m and not exceeding 3 m complete all as specified and directed.
Returning filling in including spreading, watering and well ramming in layers n.exc. 25 cm thick after the cables are laid complete all as specified and directed.
Removal of surplus soil to a distance n. exc. 50 mtrs and depositing where directed at a level n.exc. 1.5 Mtr above the starting point complete all as specified and directed.
Supply and Fix aluminium conductor steel reinforced (ACSR) straining properly on insulators and binding with aluminium tape/binding wires connectors, PC clamps, jumpers etc. complete of size 6/1x3.35 MM (Rabbit) complete all as specified and directed.
M&L for PCC 1:4:8 type D2(using 40 mm stone agg) as in foundation,filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 ( using 40 mm stone agg) as in foundation ,filling and mass concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm grade stone aggregate as in coping for new pole including necessary form work and finishing fair and even using extra cement complete all as specified and directed.
Material & labour for chemical earthing with copper earthplate electrode 90 cm X60 cm X 5 mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.50 mtr below the normal ground level connected to copper earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers .Earth strip protected by GI pipe 40 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2020) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, chemical, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed.
M/S S.S.Corporation
NIHAR ENTERPRISE
THE SUPPLY AGENCY
M/S A K MITRA
M/S DB TRADING CO
M/S BARUAH ELECTRICALS
M/S PAUL CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .